Joshua Lehr
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Joshua Lehr has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Jason J. Davis
Department of Chemistry, University of Oxford, Oxford OX1 3QZ, UK
7 shared publications Alison J. Downard
4 shared publications- Bryce E. Williamson
Department of Chemistry, University of Canterbury, Christchurch, New Zealand
4 shared publications - David J. Garrett
Department of Biomedical Engineering, RMIT University, Melbourne, VIC, 3000, Australia
4 shared publications Paul D. Beer
University of Oxford, Chemistry Research Laboratory, Oxford OX1 3TA, UK
4 shared publications- Stephen Faulkner
Chemistry Research Laboratory Department of Chemistry University of Oxford Oxford UK
4 shared publications
Latest Publications
- Open Access
- 13 August 2026
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 62 (63) , 15777-15781
Preparation of thin diazonium-derived aniline films using a supramolecular templating strategy
Supramolecular templating, using a crown ether, leads to defined formation of thin aniline films from diazonium electrografting.
- 13 August 2026
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 62 (63) , 15777-15781
Open AccessPreparation of thin diazonium-derived aniline films using a supramolecular templating strategy
Supramolecular templating, using a crown ether, leads to defined formation of thin aniline films from diazonium electrografting.
- Open Access
- 30 July 2025
- Published by Elsevier in Clinica Chimica Acta
- Vol. 578, 120522
Electrochemical sensors for diagnosis and monitoring of acute lymphoblastic leukaemia
- 30 July 2025
- Published by Elsevier in Clinica Chimica Acta
- Vol. 578, 120522
Open AccessElectrochemical sensors for diagnosis and monitoring of acute lymphoblastic leukaemia
- 10 February 2023
- Published by Wiley in Electroanalysis
- Vol. 35 (7)
Electrochemical detection of asparaginase antibodies using bifunctionalized carbon interfaces
The early detection of anti‐asparaginase biomarker can facilitate timely modification of asparaginase chemotherapy, thereby avoiding serious complications. Herein we describe the preparation of a novel electrochemical biosensing interface for rapid detection of anti‐asparaginase in the picomolar range (1–10 000 pM). Coimmobilization of ferrocene and asparaginase on a carbon interface (via diazonium grafting) facilitates transduction through attenuation of the surface‐bound ferrocene redox couple. The limit of detection of 0.8 pM for this point‐of‐care applicable method compares favourably to that of traditional faradaic assaying (2.0 pM) where transduction occurs by the target blocking the diffusion of the solution redox probe [Fe(CN)6]3−/4−.
- 10 February 2023
- Published by Wiley in Electroanalysis
- Vol. 35 (7)
Electrochemical detection of asparaginase antibodies using bifunctionalized carbon interfaces
The early detection of anti‐asparaginase biomarker can facilitate timely modification of asparaginase chemotherapy, thereby avoiding serious complications. Herein we describe the preparation of a novel electrochemical biosensing interface for rapid detection of anti‐asparaginase in the picomolar range (1–10 000 pM). Coimmobilization of ferrocene and asparaginase on a carbon interface (via diazonium grafting) facilitates transduction through attenuation of the surface‐bound ferrocene redox couple. The limit of detection of 0.8 pM for this point‐of‐care applicable method compares favourably to that of traditional faradaic assaying (2.0 pM) where transduction occurs by the target blocking the diffusion of the solution redox probe [Fe(CN)6]3−/4−.
- Open Access
- 26 January 2021
- Published by Wiley in Electroanalysis
- Vol. 33 (3) , 563-567
Label‐free Selective Detection of Protein Markers in the Picomolar Range via a Convenient Voltammetric Sensing Strategy
A convenient strategy for the preparation of label‐free selective protein biomarker sensors is presented. After formation of a ferrocene terminated monolayer on a gold electrode using thiol chemistry, grafting of an antifouling phenylalanine layer onto the preformed ferrocene monolayer is achieved by diazonium chemistry. This provides a platform for receptor (anti‐BSA or anti‐CRP) immobilization as well an antifouling interface. Specific target binding leads to attenuation of the voltammetric faradaic signal of the underlying ferrocene group. Thereby, label‐free, selective, voltammetric detection is achieved with highly competitive limits of detection in the low (≤4) picomolar range for both BSA and CRP.
- 26 January 2021
- Published by Wiley in Electroanalysis
- Vol. 33 (3) , 563-567
Open AccessLabel‐free Selective Detection of Protein Markers in the Picomolar Range via a Convenient Voltammetric Sensing Strategy
A convenient strategy for the preparation of label‐free selective protein biomarker sensors is presented. After formation of a ferrocene terminated monolayer on a gold electrode using thiol chemistry, grafting of an antifouling phenylalanine layer onto the preformed ferrocene monolayer is achieved by diazonium chemistry. This provides a platform for receptor (anti‐BSA or anti‐CRP) immobilization as well an antifouling interface. Specific target binding leads to attenuation of the voltammetric faradaic signal of the underlying ferrocene group. Thereby, label‐free, selective, voltammetric detection is achieved with highly competitive limits of detection in the low (≤4) picomolar range for both BSA and CRP.
- 12 May 2017
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 19 (23) , 15098-15109
Mapping the ionic fingerprints of molecular monolayers
Molecular dynamics simulations support a self-assembled monolayer specific energy barrier to solution-phase ions that once surmounted, the entrapped ions support a film embedded ionic capacitance and non-faradaic relaxation (mapping through electrochemical capacitance measurements). The associated capacitance can be assigned as a particular case of general electrochemical capacitance.
- 12 May 2017
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 19 (23) , 15098-15109
Mapping the ionic fingerprints of molecular monolayers
Molecular dynamics simulations support a self-assembled monolayer specific energy barrier to solution-phase ions that once surmounted, the entrapped ions support a film embedded ionic capacitance and non-faradaic relaxation (mapping through electrochemical capacitance measurements). The associated capacitance can be assigned as a particular case of general electrochemical capacitance.
- 8 September 2015
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 51 (88) , 15944-15947
Ratiometric oxygen sensing using lanthanide luminescent emitting interfaces
Herein we describe the first example of a ratiometric lanthanide luminescent oxygen sensing interface.
- 8 September 2015
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 51 (88) , 15944-15947
Ratiometric oxygen sensing using lanthanide luminescent emitting interfaces
Herein we describe the first example of a ratiometric lanthanide luminescent oxygen sensing interface.
- 6 March 2015
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 51 (30) , 6515-6517
Reversible redox modulation of a lanthanide emissive molecular film
Reactive nitrene insertion is utilized in the surface construction of ferrocene-incorporating europium d–f dyads exhibiting a reversible redox switched sensitized phosphorescence.
- 6 March 2015
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 51 (30) , 6515-6517
Reversible redox modulation of a lanthanide emissive molecular film
Reactive nitrene insertion is utilized in the surface construction of ferrocene-incorporating europium d–f dyads exhibiting a reversible redox switched sensitized phosphorescence.
- 16 December 2014
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 87 (1) , 346-350
Graphene Oxide Interfaces in Serum Based Autoantibody Quantification
A reliable quantification of protein markers will undoubtedly underpin profound developments in disease surveillance, diagnostics, and improved therapy. Although there potentially exist numerous means of achieving this, electrochemical impedimetric techniques offer scale of sensitivity, cost, convenience, and a flexibility with which few alternatives can compete. Though there have been marked developments in electroanalytical protein detection, the demands associated with accessing the inherent assay sensitivity in complex biological media largely remains. We report herein the use of cysteamine-graphene oxide modified gold microelectrode arrays in underpinning the ultrasensitive and entirely label free non-faradaic quantification of Parkinson’s-relevant autoantibodies in human serum.
- 16 December 2014
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 87 (1) , 346-350
Graphene Oxide Interfaces in Serum Based Autoantibody Quantification
A reliable quantification of protein markers will undoubtedly underpin profound developments in disease surveillance, diagnostics, and improved therapy. Although there potentially exist numerous means of achieving this, electrochemical impedimetric techniques offer scale of sensitivity, cost, convenience, and a flexibility with which few alternatives can compete. Though there have been marked developments in electroanalytical protein detection, the demands associated with accessing the inherent assay sensitivity in complex biological media largely remains. We report herein the use of cysteamine-graphene oxide modified gold microelectrode arrays in underpinning the ultrasensitive and entirely label free non-faradaic quantification of Parkinson’s-relevant autoantibodies in human serum.
- 21 April 2014
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 30 (17) , 4989-4996
Formation of Thick Aminophenyl Films from Aminobenzenediazonium Ion in the Absence of a Reduction Source
Aminophenyl films, electrografted to conducting substrates from a solution of the corresponding diazonium ion, are a useful platform for building up functional surfaces. In our hands, reproducible preparation of aminophenyl films via electrografting is difficult, suggesting competing grafting pathways. To investigate the grafting process without the possibility of reduction of the diazonium ion by the substrate, we have used a spin-coated and cured SU-8 substrate that is nonconducting and very smooth (rms surface roughness 0.43 nm). After in situ formation of the aminobenzenediazonium ion (50 mM) in acidic solution, the substrate was added to the solution in the presence and absence of reducing agents (hypophosphorous acid and iron powder). At short reaction times, the films prepared with and without reducing agent have the same thickness and composition (as revealed by X-ray photoelectron spectroscopy). However, in the presence of a reducing agent, films reach a limiting thickness of 7–8 nm after 10 min, whereas, in the absence of a reducing agent, strong film growth continues, giving a film thickness of 14 nm after 120 min. This behavior contrasts with that of other diazonium ions which, in the absence of an applied potential, a reducing agent, or a reducing substrate, give only very thin films after long reaction times.
- 21 April 2014
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 30 (17) , 4989-4996
Formation of Thick Aminophenyl Films from Aminobenzenediazonium Ion in the Absence of a Reduction Source
Aminophenyl films, electrografted to conducting substrates from a solution of the corresponding diazonium ion, are a useful platform for building up functional surfaces. In our hands, reproducible preparation of aminophenyl films via electrografting is difficult, suggesting competing grafting pathways. To investigate the grafting process without the possibility of reduction of the diazonium ion by the substrate, we have used a spin-coated and cured SU-8 substrate that is nonconducting and very smooth (rms surface roughness 0.43 nm). After in situ formation of the aminobenzenediazonium ion (50 mM) in acidic solution, the substrate was added to the solution in the presence and absence of reducing agents (hypophosphorous acid and iron powder). At short reaction times, the films prepared with and without reducing agent have the same thickness and composition (as revealed by X-ray photoelectron spectroscopy). However, in the presence of a reducing agent, films reach a limiting thickness of 7–8 nm after 10 min, whereas, in the absence of a reducing agent, strong film growth continues, giving a film thickness of 14 nm after 120 min. This behavior contrasts with that of other diazonium ions which, in the absence of an applied potential, a reducing agent, or a reducing substrate, give only very thin films after long reaction times.
- 19 March 2014
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 86 (7) , 3682
Correction to Label-free Capacitive Diagnostics: Exploiting Local Redox Probe State Occupancy
- 19 March 2014
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 86 (7) , 3682
Correction to Label-free Capacitive Diagnostics: Exploiting Local Redox Probe State Occupancy