Qiaofeng Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Qiaofeng Li has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Zhixian Gao
Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Military Medical Sciences Academy, Academy of Military Sciences, Tianjin, 300050, China
5 shared publications - Weiya Wang
School of Food Science and Technology, International Joint Laboratory on Food Safety, Synergetic Innovation Center of Food Safety and Quality Control, Jiangnan University, Wuxi, Jiangsu, 214122, China; Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin, 300050, China
3 shared publications Dianpeng Han
Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety
2 shared publicationsJialei Bai
Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin 300050, People’s Republic of China
2 shared publicationsJin Wu
Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin 300050, People’s Republic of China
2 shared publicationsMingzhu Liu
Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Tianjin Institute of Environmental and Operational Medicine, Tianjin 300050, People’s Republic of China
2 shared publications
Latest Publications
- Open Access
- 9 April 2026
- Published by MDPI AG in Biosensors
- Vol. 16 (4) , 209
Ultrasensitive Detection of Staphylococcus aureus Based on Photonic Crystal Microsphere Suspension Array-Assisted Loop-Mediated Isothermal Amplification
The development of high-throughput, sensitive and portable strategies for detecting foodborne pathogens is urgently needed in food safety, especially during an outbreak. Herein, an ultrasensitive suspension array was constructed by designing photonic crystal microsphere (PCM)-assisted loop-mediated isothermal amplification (LAMP) for Staphylococcus aureus detection. The PCM-LAMP suspension array integrated the optical signal enhancement capability of the biomimetic microporous three-dimensional PCM surface with the thousand-fold signal amplification of LAMP. The biomimetic PCMs displayed a periodic dielectric nanostructure and enhanced the fluorescence intensity of the LAMP reaction, leading to high sensitivity. The PCM-LAMP suspension array allowed sensitive detection of the target DNA of S. aureus without long-term culture. Under optimal conditions, the limit of detection for S. aureus genomic DNA reached as low as 0.18 fM, and the assay exhibited excellent specificity against other bacteria. Furthermore, trace target DNA in food samples was accurately quantified, demonstrating its potential for practical applications. Therefore, the developed PCM-LAMP suspension array holds great promise for ultrasensitive and rapid detection of foodborne pathogens.
- 9 April 2026
- Published by MDPI AG in Biosensors
- Vol. 16 (4) , 209
Open AccessUltrasensitive Detection of Staphylococcus aureus Based on Photonic Crystal Microsphere Suspension Array-Assisted Loop-Mediated Isothermal Amplification
The development of high-throughput, sensitive and portable strategies for detecting foodborne pathogens is urgently needed in food safety, especially during an outbreak. Herein, an ultrasensitive suspension array was constructed by designing photonic crystal microsphere (PCM)-assisted loop-mediated isothermal amplification (LAMP) for Staphylococcus aureus detection. The PCM-LAMP suspension array integrated the optical signal enhancement capability of the biomimetic microporous three-dimensional PCM surface with the thousand-fold signal amplification of LAMP. The biomimetic PCMs displayed a periodic dielectric nanostructure and enhanced the fluorescence intensity of the LAMP reaction, leading to high sensitivity. The PCM-LAMP suspension array allowed sensitive detection of the target DNA of S. aureus without long-term culture. Under optimal conditions, the limit of detection for S. aureus genomic DNA reached as low as 0.18 fM, and the assay exhibited excellent specificity against other bacteria. Furthermore, trace target DNA in food samples was accurately quantified, demonstrating its potential for practical applications. Therefore, the developed PCM-LAMP suspension array holds great promise for ultrasensitive and rapid detection of foodborne pathogens.
- Top Cited PapersOpen Access
- 6 January 2026
- Published by Wiley in Interdisciplinary Medicine
- Vol. 4 (1)
Advances and challenges in point‐of‐care testing for pathogenic bacteria in battlefield injuries
Infections are a leading contributor to delayed mortality in patients with combat‐related trauma. Thus, the real‐time, accurate, and rapid detection of invasive pathogens is essential for optimizing wound management and accelerating recovery. Recent innovations in point‐of‐care testing (POCT) biosensors, which are characterized by enhanced portability and multifunctionality, offer promising solutions for onsite diagnostics without relying on centralized laboratories. These technologies are particularly effective for the minimally invasive monitoring of real‐time biophysical or biochemical signals at wound sites. This review explores the species and distribution of bacteria associated with combat‐related injuries. Thereafter, we summarize recent advancements in optical and other biosensors (electrochemical, piezoelectric, and thermal) used in bacterial POCT. Key integration strategies are highlighted, including biosensor coupling with microdevices (e.g., microfluidics and microarrays), smart systems (e.g., smartphone readouts and artificial intelligence‐based interpretation), and the Internet of Things. We also address the current challenges in biosensor fabrication and outline the expected future directions for biosensing. This review aims to provide a useful reference for the development of POCT biosensors for bacterial detection in combat and trauma care settings.
- 6 January 2026
- Published by Wiley in Interdisciplinary Medicine
- Vol. 4 (1)
Top Cited PapersOpen AccessAdvances and challenges in point‐of‐care testing for pathogenic bacteria in battlefield injuries
Infections are a leading contributor to delayed mortality in patients with combat‐related trauma. Thus, the real‐time, accurate, and rapid detection of invasive pathogens is essential for optimizing wound management and accelerating recovery. Recent innovations in point‐of‐care testing (POCT) biosensors, which are characterized by enhanced portability and multifunctionality, offer promising solutions for onsite diagnostics without relying on centralized laboratories. These technologies are particularly effective for the minimally invasive monitoring of real‐time biophysical or biochemical signals at wound sites. This review explores the species and distribution of bacteria associated with combat‐related injuries. Thereafter, we summarize recent advancements in optical and other biosensors (electrochemical, piezoelectric, and thermal) used in bacterial POCT. Key integration strategies are highlighted, including biosensor coupling with microdevices (e.g., microfluidics and microarrays), smart systems (e.g., smartphone readouts and artificial intelligence‐based interpretation), and the Internet of Things. We also address the current challenges in biosensor fabrication and outline the expected future directions for biosensing. This review aims to provide a useful reference for the development of POCT biosensors for bacterial detection in combat and trauma care settings.
- Open Access
- 24 April 2025
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 73 (18) , 11340-11350
Reference Gene-Assisted LAMP–LFD for Sensitive and Specific Detection of Soy DNA as a Marker for Allergen Presence in Complex Food Products
Sensitive, selective screening for allergenic ingredients with internal control is crucial to identify food adulteration and remove allergens from the food chain. Here, loop-mediated isothermal amplification combined with a lateral flow device (LAMP-LFD) was developed for the fast and easy detection of soy DNA. The integrated quality controls included a regular control line to ensure proper implementation (extraction and amplification control) and a second LAMP-LFD assay for the cytochrome oxidase gene, which is a housekeeping gene in plants. The developed LAMP assay showed a limit of detection of only 5 pg DNA input per reaction, for both pure soy and spiked food samples. The test was subsequently implemented for the examination of 32 real food products with different compositions and declared soy contents, and benchmarked against qPCR. Then, this system was combined with a digital cube reader, allowing direct interpretation of the test results, facilitating the point-of-need applicability.
- 24 April 2025
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 73 (18) , 11340-11350
Open AccessReference Gene-Assisted LAMP–LFD for Sensitive and Specific Detection of Soy DNA as a Marker for Allergen Presence in Complex Food Products
Sensitive, selective screening for allergenic ingredients with internal control is crucial to identify food adulteration and remove allergens from the food chain. Here, loop-mediated isothermal amplification combined with a lateral flow device (LAMP-LFD) was developed for the fast and easy detection of soy DNA. The integrated quality controls included a regular control line to ensure proper implementation (extraction and amplification control) and a second LAMP-LFD assay for the cytochrome oxidase gene, which is a housekeeping gene in plants. The developed LAMP assay showed a limit of detection of only 5 pg DNA input per reaction, for both pure soy and spiked food samples. The test was subsequently implemented for the examination of 32 real food products with different compositions and declared soy contents, and benchmarked against qPCR. Then, this system was combined with a digital cube reader, allowing direct interpretation of the test results, facilitating the point-of-need applicability.
- 14 February 2024
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 72 (8) , 4415-4425
Ultrasensitive Detection Strategy of Norovirus Based on a Dual Enhancement Strategy: CRISPR-Responsive Self-Assembled SNA and Isothermal Amplification
Spherical nucleic acids (SNAs) have been used to construct various nanobiosensors with gold nanoparticles (AuNPs) as nuclei. The SNAs play a critical role in biosensing due to their various physical and chemical properties, programmability, and specificity recognition ability. In this study, CRISPR-responsive self-assembled spherical nucleic acid (CRISPR-rsSNA) detection probes were constructed by conjugating fluorescein-labeled probes to the surface of AuNPs to improve the sensing performance. Also, the mechanism of ssDNA and the role of different fluorescent groups in the self-assembly process of CRISPR-rsSNA were explored. Then, CRISPR-rsSNA and reverse transcription-recombinase polymerase amplification (RT-RPA) were combined to develop an ultrasensitive fluorescence-detection strategy for norovirus. In the presence of the virus, the target RNA sequence of the virus was transformed and amplified by RT-RPA. The resulting dsDNA activated the trans-cleavage activity of CRISPR cas12a, resulting in disintegrating the outer nucleic acid structure of the CRISPR-rsSNA at a diffusible rate, which released reporter molecules. Norovirus was quantitated by fluorescence detection. This strategy facilitated the detection of the norovirus at the attomolar level. An RT-RPA kit for norovirus detected would be developed based on this method. The proposed method would be used for the detection of different viruses just by changing the target RNA and crRNA of the CRISPR cas12a system which provided a foundation for high-throughput detection of various substances.
- 14 February 2024
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 72 (8) , 4415-4425
Ultrasensitive Detection Strategy of Norovirus Based on a Dual Enhancement Strategy: CRISPR-Responsive Self-Assembled SNA and Isothermal Amplification
Spherical nucleic acids (SNAs) have been used to construct various nanobiosensors with gold nanoparticles (AuNPs) as nuclei. The SNAs play a critical role in biosensing due to their various physical and chemical properties, programmability, and specificity recognition ability. In this study, CRISPR-responsive self-assembled spherical nucleic acid (CRISPR-rsSNA) detection probes were constructed by conjugating fluorescein-labeled probes to the surface of AuNPs to improve the sensing performance. Also, the mechanism of ssDNA and the role of different fluorescent groups in the self-assembly process of CRISPR-rsSNA were explored. Then, CRISPR-rsSNA and reverse transcription-recombinase polymerase amplification (RT-RPA) were combined to develop an ultrasensitive fluorescence-detection strategy for norovirus. In the presence of the virus, the target RNA sequence of the virus was transformed and amplified by RT-RPA. The resulting dsDNA activated the trans-cleavage activity of CRISPR cas12a, resulting in disintegrating the outer nucleic acid structure of the CRISPR-rsSNA at a diffusible rate, which released reporter molecules. Norovirus was quantitated by fluorescence detection. This strategy facilitated the detection of the norovirus at the attomolar level. An RT-RPA kit for norovirus detected would be developed based on this method. The proposed method would be used for the detection of different viruses just by changing the target RNA and crRNA of the CRISPR cas12a system which provided a foundation for high-throughput detection of various substances.
- 2 December 2022
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 14 (49) , 54914-54923
Ultrasensitive Automatic Detection of Small Molecules by Membrane Imaging of Single Molecule Assays
- 2 December 2022
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 14 (49) , 54914-54923
Ultrasensitive Automatic Detection of Small Molecules by Membrane Imaging of Single Molecule Assays
- 2 March 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (10) , 4488-4496
Ultrasensitive Detection of 17β-Estradiol (E2) Based on Multistep Isothermal Amplification
17β-Estradiol (E2) can cause an adverse effect on the human endocrine system even at the nanomolar level. Measurements of very low levels of E2 remain a critical challenge due to insufficient sensitivity. In this study, a multistep isothermal amplification fluorescence strategy was constructed, which could realize the exponential amplification of target E2. Specifically, strand displacement reaction (SDA), rolling circle amplification (RCA), and multiprimed rolling circle amplification (MRCA) were combined in a series to quantify trace complementary strand of E2 (cDNA). The E2 aptamer and cDNA were hybridized and modified on the magnetic beads. E2 could bind to its aptamer and cause the release of the cDNA. Then, cDNA would combine with the template DNA, initiating the SDA–RCA–MRCA. The molecular beacons, possessing low background signal, whose fluorescence was quenched in the state of chain folding, could be specifically recognized by the long single-stranded DNA (L-ssDNA) generated by the multistep isothermal amplification triggered by cDNA, and then the fluorescence of the molecular beacons could be restored. Therefore, the E2 could be quantitatively detected by the recovery fluorescence intensity. The fluorescence value showed a good linear relationship with the concentration of E2 in the range of 0.001836–183.6 nM, and the limit of detection (LOD) was as low as 63.09 fM. In addition, the recovery rates of this method spiked in milk and water were 80.8–107.0%, respectively. This method has the advantage of multistep isothermal amplification to obtain abundant fluorescence signals, which may provide a new possibility for highly sensitive detection of other small-molecule targets.
- 2 March 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (10) , 4488-4496
Ultrasensitive Detection of 17β-Estradiol (E2) Based on Multistep Isothermal Amplification
17β-Estradiol (E2) can cause an adverse effect on the human endocrine system even at the nanomolar level. Measurements of very low levels of E2 remain a critical challenge due to insufficient sensitivity. In this study, a multistep isothermal amplification fluorescence strategy was constructed, which could realize the exponential amplification of target E2. Specifically, strand displacement reaction (SDA), rolling circle amplification (RCA), and multiprimed rolling circle amplification (MRCA) were combined in a series to quantify trace complementary strand of E2 (cDNA). The E2 aptamer and cDNA were hybridized and modified on the magnetic beads. E2 could bind to its aptamer and cause the release of the cDNA. Then, cDNA would combine with the template DNA, initiating the SDA–RCA–MRCA. The molecular beacons, possessing low background signal, whose fluorescence was quenched in the state of chain folding, could be specifically recognized by the long single-stranded DNA (L-ssDNA) generated by the multistep isothermal amplification triggered by cDNA, and then the fluorescence of the molecular beacons could be restored. Therefore, the E2 could be quantitatively detected by the recovery fluorescence intensity. The fluorescence value showed a good linear relationship with the concentration of E2 in the range of 0.001836–183.6 nM, and the limit of detection (LOD) was as low as 63.09 fM. In addition, the recovery rates of this method spiked in milk and water were 80.8–107.0%, respectively. This method has the advantage of multistep isothermal amplification to obtain abundant fluorescence signals, which may provide a new possibility for highly sensitive detection of other small-molecule targets.
- 13 December 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (1) , 1611-1617
A Colorimetric Strip for Rapid Detection and Real-Time Monitoring of Histamine in Fish Based on Self-Assembled Polydiacetylene Vesicles
Self-assembled polydiacetylene (PDA) vesicles, with the distinct advantages of low-cost materials, simple preparation as well as excellent chromatic properties, can be perfectly combined with colorimetric strip for on-site inspection. Herein, without in-volving expensive reagents and instruments, a visual colorimetric strip based on well-prepared PDA vesicles was developed to analyze and monitor histamine in deep-sea fish and its canned food. The standard calorimetric card for semiquantitative detec-tion of histamine was successfully prepared and the quantitative detection can be further realized by analyzing the gray value using image J and “Color Grab” in the smart phone. After optimizing the assembly conditions, this assay exhibited a linear response to histamine within the range from 70 ppm to 2240 ppm. With excellent stability and sensitivity, this strip can be used to monitor the quality change of canned fish at different temperatures, so that people can avoid suffering from histamine poisoning, suggesting that it holds great potential in the intelligent system for on-site detection and real-time monitoring.
- 13 December 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (1) , 1611-1617
A Colorimetric Strip for Rapid Detection and Real-Time Monitoring of Histamine in Fish Based on Self-Assembled Polydiacetylene Vesicles
Self-assembled polydiacetylene (PDA) vesicles, with the distinct advantages of low-cost materials, simple preparation as well as excellent chromatic properties, can be perfectly combined with colorimetric strip for on-site inspection. Herein, without in-volving expensive reagents and instruments, a visual colorimetric strip based on well-prepared PDA vesicles was developed to analyze and monitor histamine in deep-sea fish and its canned food. The standard calorimetric card for semiquantitative detec-tion of histamine was successfully prepared and the quantitative detection can be further realized by analyzing the gray value using image J and “Color Grab” in the smart phone. After optimizing the assembly conditions, this assay exhibited a linear response to histamine within the range from 70 ppm to 2240 ppm. With excellent stability and sensitivity, this strip can be used to monitor the quality change of canned fish at different temperatures, so that people can avoid suffering from histamine poisoning, suggesting that it holds great potential in the intelligent system for on-site detection and real-time monitoring.