Jyrki Nieminen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jyrki Nieminen has a total of 95 co-authors. Here are the top co-authors by number of shared publications:
- Antti Eskelinen
Coxa Hospital for Joint Replacement, and Faculty of Medicine and Health Technologies, University of Tampere, Tampere, Finland
7 shared publications - Minna Laitinen
Department of Orthopaedics, Helsinki University Hospital, Helsinki, Finland
7 shared publications - Aleksi Reito
Coxa Hospital for Joint Replacement and Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
5 shared publications K. Puustjärvi
Department of Physical Medicine and Rehabilitation, University Hospital of Helsinki, Finland
4 shared publicationsH. J. Helminen
Department of Anatomy, University of Kuopio, Finland
3 shared publicationsHeikki J. Helminen
Department of Anatomy, Institute of Biomedicine, University of Kuopio, Kuopio, Finland
3 shared publications
Latest Publications
- 1 December 2019
- Published by Elsevier in European Journal of Surgical Oncology
- Vol. 45 (12) , 2424-2430
Revision rate of reconstructions in surgically treated diaphyseal metastases of bone
- 1 December 2019
- Published by Elsevier in European Journal of Surgical Oncology
- Vol. 45 (12) , 2424-2430
Revision rate of reconstructions in surgically treated diaphyseal metastases of bone
- 10 May 2017
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 137 (7) , 967-973
Complications after surgical treatment of femoral neck fractures in men with alcohol dependence syndrome: retrospective register analysis of 154 cases
Purpose One-third of hip fractures occur in men. The causes underlying hip fractures in men differ from those in women and include alcohol abuse. This retrospective register study evaluated the trends and results associated with different surgical treatment methods for nondisplaced and displaced femoral neck fractures in male patients with alcohol dependence syndrome. Methods Men with hip fractures were identified from a local district hospital database. Alcohol dependence syndrome was identified as a diagnosis in medical records. Results For displaced fractures, implant survival after total hip arthroplasty was significantly lower compared to hemiarthroplasty. For nondisplaced fractures, implant survival of cannulated screws was significantly lower compared to sliding hip screws. Overall patient survival for males with alcohol dependence syndrome with hip fracture was 62% at 1 year and 49% at 2 years. Patient survival in this population did not differ between displaced and nondisplaced fractures or among different surgical methods. Conclusion Patients with alcoholism who had documented evidence of alcohol dependence syndrome represented nearly half of patients <70 years old with low-energy hip fracture. In patients with nondisplaced femoral neck fractures, stability of the internal fixation appeared to play a major role in implant survival; sliding hip screws should be considered over multiple cannulated screws. In patients with displaced fracture, total hip arthroplasty was associated with a significantly higher risk of complications leading to revision compared to hemiarthoplasty. Level of evidence Prognostic Level III.
- 10 May 2017
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 137 (7) , 967-973
Complications after surgical treatment of femoral neck fractures in men with alcohol dependence syndrome: retrospective register analysis of 154 cases
Purpose One-third of hip fractures occur in men. The causes underlying hip fractures in men differ from those in women and include alcohol abuse. This retrospective register study evaluated the trends and results associated with different surgical treatment methods for nondisplaced and displaced femoral neck fractures in male patients with alcohol dependence syndrome. Methods Men with hip fractures were identified from a local district hospital database. Alcohol dependence syndrome was identified as a diagnosis in medical records. Results For displaced fractures, implant survival after total hip arthroplasty was significantly lower compared to hemiarthroplasty. For nondisplaced fractures, implant survival of cannulated screws was significantly lower compared to sliding hip screws. Overall patient survival for males with alcohol dependence syndrome with hip fracture was 62% at 1 year and 49% at 2 years. Patient survival in this population did not differ between displaced and nondisplaced fractures or among different surgical methods. Conclusion Patients with alcoholism who had documented evidence of alcohol dependence syndrome represented nearly half of patients <70 years old with low-energy hip fracture. In patients with nondisplaced femoral neck fractures, stability of the internal fixation appeared to play a major role in implant survival; sliding hip screws should be considered over multiple cannulated screws. In patients with displaced fracture, total hip arthroplasty was associated with a significantly higher risk of complications leading to revision compared to hemiarthoplasty. Level of evidence Prognostic Level III.
- Open Access
- 26 January 2017
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 88 (3) , 269-274
High blood metal ion levels in 19 of 22 patients with metal-on-metal hinge knee replacements
Background and purpose — There has been increasing alarm regarding metal-on-metal (MoM) joint replacements leading to elevated levels of metal ions and adverse reactions to metal debris (ARMDs). There is little information available concerning the prevalence of and risk factors for these adverse reactions, except with MoM hip joint replacements. We determined the levels of metal ions in blood and the rate of revision due to ARMDs in patients treated with MoM hinge total knee arthroplasty (TKA). Patients and methods — 22 patients with TKAs and MoM hinge connecting mechanisms were studied for whole-blood chromium and cobalt levels at 6 months, 1 year, and/or ≥2 years after surgery. Possible ARMDs were investigated by MRI. 12 patients with TKAs and metal-on-polyethylene (MoP) connecting mechanisms served as controls. Results — The cobalt levels were over 5 ppb in 19 of the 22 patients in the MoM group and in 1 of the 12 patients in the MoP group. The chromium levels were over 5 ppb in 11 of the 22 patients in the MoM group and in none of the 12 patients in the MoP group. Pseudotumors were operated in 4 of the 22 patients in the MoM group and in none of the patients in the MoP group. Interpretation — Our results clearly show that the MoM hinge TKA carries a high risk of increased levels of systemic metal ions and also local ARMD, leading to complicated knee revisions. We therefore discourage the use of MoM hinge TKA.
- 26 January 2017
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 88 (3) , 269-274
Open AccessHigh blood metal ion levels in 19 of 22 patients with metal-on-metal hinge knee replacements
Background and purpose — There has been increasing alarm regarding metal-on-metal (MoM) joint replacements leading to elevated levels of metal ions and adverse reactions to metal debris (ARMDs). There is little information available concerning the prevalence of and risk factors for these adverse reactions, except with MoM hip joint replacements. We determined the levels of metal ions in blood and the rate of revision due to ARMDs in patients treated with MoM hinge total knee arthroplasty (TKA). Patients and methods — 22 patients with TKAs and MoM hinge connecting mechanisms were studied for whole-blood chromium and cobalt levels at 6 months, 1 year, and/or ≥2 years after surgery. Possible ARMDs were investigated by MRI. 12 patients with TKAs and metal-on-polyethylene (MoP) connecting mechanisms served as controls. Results — The cobalt levels were over 5 ppb in 19 of the 22 patients in the MoM group and in 1 of the 12 patients in the MoP group. The chromium levels were over 5 ppb in 11 of the 22 patients in the MoM group and in none of the 12 patients in the MoP group. Pseudotumors were operated in 4 of the 22 patients in the MoM group and in none of the patients in the MoP group. Interpretation — Our results clearly show that the MoM hinge TKA carries a high risk of increased levels of systemic metal ions and also local ARMD, leading to complicated knee revisions. We therefore discourage the use of MoM hinge TKA.
- 1 April 2016
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 102 (2) , 167-173
Repeated metal ion measurement in patients with bilateral metal on metal (ASR™) hip replacements
- 1 April 2016
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 102 (2) , 167-173
Repeated metal ion measurement in patients with bilateral metal on metal (ASR™) hip replacements
- Open Access
- 1 October 2015
- Published by Taylor & Francis in Acta Orthopaedica
- Vol. 87 (1) , 29-35
Gluteal muscle fatty atrophy is not associated with elevated blood metal ions or pseudotumors in patients with a unilateral metal-on-metal hip replacement
Background and purpose — There are no international guidelines to define adverse reaction to metal debris (ARMD). Muscle fatty atrophy has been reported to be common in patients with failing metal-on-metal (MoM) hip replacements. We assessed whether gluteal muscle fatty atrophy is associated with elevated blood metal ion levels and pseudotumors. Patients and methods — 263 consecutive patients with unilateral ASR XL total hip replacement using a posterior approach and with an unoperated contralateral hip were included in the study. All patients had undergone a standard screening program at our institution, including MRI and blood metal ion measurement. Muscle fatty atrophy was graded as being absent, mild, moderate, or severe in each of the gluteal muscles. Results — The prevalance of moderate-to-severe gluteal muscle atrophy was low (12% for gluteus minimus, 10% for gluteus medius, and 2% for gluteus maximus). Muscle atrophy was neither associated with elevated blood metal ion levels (> 5 ppb) nor with the presence of a clear (solid- or mixed-type) pseudotumor seen in MRI. A combination of moderate-to-severe atrophy in MRI, elevated blood metal ion levels, and MRI-confirmed mixed or solid pseudotumor was rare. Multivariable regression revealed that “preoperative diagnosis other than osteoarthrosis” was the strongest predictor of the presence of fatty atrophy. Interpretation — Gluteal muscle atrophy may be a clinically significant finding with influence on hip muscle strength in patients with MoM hip replacement. However, our results suggest that gluteal muscle atrophy seen in MRI is not associated with either the presence or severity of ARMD, at least not in patients who have been operated on using the posterior approach.
- 1 October 2015
- Published by Taylor & Francis in Acta Orthopaedica
- Vol. 87 (1) , 29-35
Open AccessGluteal muscle fatty atrophy is not associated with elevated blood metal ions or pseudotumors in patients with a unilateral metal-on-metal hip replacement
Background and purpose — There are no international guidelines to define adverse reaction to metal debris (ARMD). Muscle fatty atrophy has been reported to be common in patients with failing metal-on-metal (MoM) hip replacements. We assessed whether gluteal muscle fatty atrophy is associated with elevated blood metal ion levels and pseudotumors. Patients and methods — 263 consecutive patients with unilateral ASR XL total hip replacement using a posterior approach and with an unoperated contralateral hip were included in the study. All patients had undergone a standard screening program at our institution, including MRI and blood metal ion measurement. Muscle fatty atrophy was graded as being absent, mild, moderate, or severe in each of the gluteal muscles. Results — The prevalance of moderate-to-severe gluteal muscle atrophy was low (12% for gluteus minimus, 10% for gluteus medius, and 2% for gluteus maximus). Muscle atrophy was neither associated with elevated blood metal ion levels (> 5 ppb) nor with the presence of a clear (solid- or mixed-type) pseudotumor seen in MRI. A combination of moderate-to-severe atrophy in MRI, elevated blood metal ion levels, and MRI-confirmed mixed or solid pseudotumor was rare. Multivariable regression revealed that “preoperative diagnosis other than osteoarthrosis” was the strongest predictor of the presence of fatty atrophy. Interpretation — Gluteal muscle atrophy may be a clinically significant finding with influence on hip muscle strength in patients with MoM hip replacement. However, our results suggest that gluteal muscle atrophy seen in MRI is not associated with either the presence or severity of ARMD, at least not in patients who have been operated on using the posterior approach.
- 1 September 2015
- Published by Elsevier in European Geriatric Medicine
- Vol. 6, S149
P-436: The incidence of periprosthetic femoral fractures after total hip replacement in the Pirkanmaa Hospital District, Finland during 2002–2010
- 1 September 2015
- Published by Elsevier in European Geriatric Medicine
- Vol. 6, S149
P-436: The incidence of periprosthetic femoral fractures after total hip replacement in the Pirkanmaa Hospital District, Finland during 2002–2010
- Open Access
- 19 September 2014
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 85 (6) , 570-576
Repeated magnetic resonance imaging in 154 hips with large-diameter metal-on-metal hip replacement
The US Food and Drug Administration and the UK Medicines and Health Regulation Agency recommend using MRI in the evaluation of patients with large-diameter metal-on-metal (LD-MoM) hips. Such recommendations do not take into account the relevance of repeated cross-sectional imaging. We therefore investigated the natural course of pseudotumors in patients with LD-MoM hip replacements. Of 888 ASR patients (1,036 hips) 674 patients (798 hips) underwent 2 follow-up visits at our institution. Of these, we identified 124 patients (154 hips) who had undergone repeated clinical assessment including MRI and whole-blood metal ion assessment. A change in classification in imaging findings between the 2 MRIs was seen in 17 of the 154 hips (11%). In 13 hips (8%), a significant progression of the pseudotumor was evident, while in 4 (3 %) there was a retrogressive change. 10 of these 13 hips had had a normal first MRI. Patients with a progressive change in the scans did not differ significantly from those without a change in MRI classification regarding follow-up time, time interval between MRIs, or changes in whole-blood Cr and Co levels between assessments. A change in classification was rare, considering that all patients had a clinical indication for repeated imaging. Progression of the findings did not appear to correlate clearly with symptoms or whole-blood metal values.
- 19 September 2014
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 85 (6) , 570-576
Open AccessRepeated magnetic resonance imaging in 154 hips with large-diameter metal-on-metal hip replacement
The US Food and Drug Administration and the UK Medicines and Health Regulation Agency recommend using MRI in the evaluation of patients with large-diameter metal-on-metal (LD-MoM) hips. Such recommendations do not take into account the relevance of repeated cross-sectional imaging. We therefore investigated the natural course of pseudotumors in patients with LD-MoM hip replacements. Of 888 ASR patients (1,036 hips) 674 patients (798 hips) underwent 2 follow-up visits at our institution. Of these, we identified 124 patients (154 hips) who had undergone repeated clinical assessment including MRI and whole-blood metal ion assessment. A change in classification in imaging findings between the 2 MRIs was seen in 17 of the 154 hips (11%). In 13 hips (8%), a significant progression of the pseudotumor was evident, while in 4 (3 %) there was a retrogressive change. 10 of these 13 hips had had a normal first MRI. Patients with a progressive change in the scans did not differ significantly from those without a change in MRI classification regarding follow-up time, time interval between MRIs, or changes in whole-blood Cr and Co levels between assessments. A change in classification was rare, considering that all patients had a clinical indication for repeated imaging. Progression of the findings did not appear to correlate clearly with symptoms or whole-blood metal values.
- Open Access
- 20 July 2014
- Published by Wiley in Case Reports in Orthopedics
- Vol. 2014, 1-6
An Unusual Case of Clear Cell Chondrosarcoma with Very Late Recurrence and Lung Metastases, 29 Years after Primary Surgery
Clear cell chondrosarcoma is a rare bone neoplasm with low-grade clinical course and the potential to metastasize to the skeleton and lungs. The aim of this report is to present a case that is extremely rare, but in accordance with the literature where the clear cell chondrosarcoma reportedly has a tendency for late metastases. In our patient the primary surgery was intralesional, since it was mistakenly interpreted as a benign tumour in the early 80s. The local recurrence and lung metastases occurred, however, 29 years after the initial treatment. The local recurrence was resected with wide margins, no additional surgery or oncological treatments were given, and two and half years postoperatively patient is doing well and there is no progression in the disease. In conclusion, it is important to have a long follow-up to the clear cell chondrosarcoma patients even for decades or lifelong, because the malignancy tends to metastasize or recur after an extended period. The course of metastasized disease may be unusually slow, so relatively aggressive treatment in metastasized and recurring cases is justified.
- 20 July 2014
- Published by Wiley in Case Reports in Orthopedics
- Vol. 2014, 1-6
Open AccessAn Unusual Case of Clear Cell Chondrosarcoma with Very Late Recurrence and Lung Metastases, 29 Years after Primary Surgery
Clear cell chondrosarcoma is a rare bone neoplasm with low-grade clinical course and the potential to metastasize to the skeleton and lungs. The aim of this report is to present a case that is extremely rare, but in accordance with the literature where the clear cell chondrosarcoma reportedly has a tendency for late metastases. In our patient the primary surgery was intralesional, since it was mistakenly interpreted as a benign tumour in the early 80s. The local recurrence and lung metastases occurred, however, 29 years after the initial treatment. The local recurrence was resected with wide margins, no additional surgery or oncological treatments were given, and two and half years postoperatively patient is doing well and there is no progression in the disease. In conclusion, it is important to have a long follow-up to the clear cell chondrosarcoma patients even for decades or lifelong, because the malignancy tends to metastasize or recur after an extended period. The course of metastasized disease may be unusually slow, so relatively aggressive treatment in metastasized and recurring cases is justified.