Ali Özcan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ali Özcan has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Yucel Sahin
Yildiz Technical University
14 shared publications Mehmet A. Oturan
10 shared publications- Ayça Atılır Özcan
Anadolu University, Faculty of Science, Department of Chemistry, 26470 Eskişehir, Turkey
6 shared publications Nihal Oturan
4 shared publicationsA. Savaş Koparal
3 shared publicationsAyça Özcan
2 shared publications
Latest Publications
- 25 December 2025
- Published by Anadolu Universitesi Bilim ve Teknoloji Dergisi-A: Uygulamali Bilimler ve Muhendislik in Eskişehir Technical University Journal of Science and Technology A - Applied Sciences and Engineering
- Vol. 26 (4) , 486-500
DEVELOPMENT OF AN ELECTROCHEMICALLY EXFOLIATED GRAPHENE OXIDE MODIFIED ELECTRODE FOR SENSITIVE CHLORAMPHENICOL DETECTION IN FOOD SAMPLES
This study presents the development of a voltammetric sensing method utilizing a glassy carbon electrode modified with electrochemically exfoliated graphene oxide (EEGO) for detecting chloramphenicol (CAP), a broad-spectrum antibiotic of concern for food safety. EEGO was synthesized through an electrochemical exfoliation process using 0.25 M LiClO4 as the electrolyte and characterized using cyclic voltammetry, scanning electron microscopy, electrochemical impedance spectroscopy, and X-ray diffraction, confirming its favorable structural and electrochemical properties. The EEGO-modified electrode exhibited superior electrochemical performance compared to bare glassy carbon electrodes, offering a broader linear range (1.0–62.5 μM) and a lower detection limit (0.067 μM) for CAP. The enhanced performance of the EEGO-modified electrode can be attributed to the high surface area, excellent electrical conductivity, and abundant oxygen-containing functional groups of EEGO, which facilitate electron transfer and promote strong analyte adsorption. The proposed sensor demonstrated excellent selectivity and stability, maintaining its performance even in the presence of common interfering substances in food matrices. The developed method was successfully applied to determine CAP in milk and honey samples, with recovery values between 84.88% and 109.48%, demonstrating its potential for practical applications in food safety monitoring. The developed voltammetric method is characterized by its simplicity and high sensitivity, eliminating the need for complex sample pretreatment. This method effectively identifies CAP in food matrices, thereby contributing to the development of practical analytical tools for monitoring food safety.
- 25 December 2025
- Published by Anadolu Universitesi Bilim ve Teknoloji Dergisi-A: Uygulamali Bilimler ve Muhendislik in Eskişehir Technical University Journal of Science and Technology A - Applied Sciences and Engineering
- Vol. 26 (4) , 486-500
DEVELOPMENT OF AN ELECTROCHEMICALLY EXFOLIATED GRAPHENE OXIDE MODIFIED ELECTRODE FOR SENSITIVE CHLORAMPHENICOL DETECTION IN FOOD SAMPLES
This study presents the development of a voltammetric sensing method utilizing a glassy carbon electrode modified with electrochemically exfoliated graphene oxide (EEGO) for detecting chloramphenicol (CAP), a broad-spectrum antibiotic of concern for food safety. EEGO was synthesized through an electrochemical exfoliation process using 0.25 M LiClO4 as the electrolyte and characterized using cyclic voltammetry, scanning electron microscopy, electrochemical impedance spectroscopy, and X-ray diffraction, confirming its favorable structural and electrochemical properties. The EEGO-modified electrode exhibited superior electrochemical performance compared to bare glassy carbon electrodes, offering a broader linear range (1.0–62.5 μM) and a lower detection limit (0.067 μM) for CAP. The enhanced performance of the EEGO-modified electrode can be attributed to the high surface area, excellent electrical conductivity, and abundant oxygen-containing functional groups of EEGO, which facilitate electron transfer and promote strong analyte adsorption. The proposed sensor demonstrated excellent selectivity and stability, maintaining its performance even in the presence of common interfering substances in food matrices. The developed method was successfully applied to determine CAP in milk and honey samples, with recovery values between 84.88% and 109.48%, demonstrating its potential for practical applications in food safety monitoring. The developed voltammetric method is characterized by its simplicity and high sensitivity, eliminating the need for complex sample pretreatment. This method effectively identifies CAP in food matrices, thereby contributing to the development of practical analytical tools for monitoring food safety.
- 10 September 2023
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 51, 690-702
Investigation of the effects of ethanolamine, 2-mercaptoethanol and citrate as capping agent and heteroatom source on ethylene glycol oxidation activity of heteroatom-doped reduced graphene oxide nanocomposites decorated with gold nanoparticles
- 10 September 2023
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 51, 690-702
Investigation of the effects of ethanolamine, 2-mercaptoethanol and citrate as capping agent and heteroatom source on ethylene glycol oxidation activity of heteroatom-doped reduced graphene oxide nanocomposites decorated with gold nanoparticles
- 4 September 2022
- Published by Wiley in Polymers for Advanced Technologies
- Vol. 33 (12) , 3966-3976
Carbon nanotube‐polybutadiene‐poly(ethylene oxide)‐based composite fibers: Role of cryogenic treatment on intrinsic properties
The low‐temperature response and the notion of crystallization kinetics are critical for developing elastomeric composite fibers, thus the crystallization and mechanical properties are essential for the application of composites of polybutadiene at low temperatures. Despite the high amount of fiber joining and entanglement due to polymers' low glass transition, a defect‐free micro‐scale electrospun carbon nanotube (CNT)‐containing poly(ethylene oxide) (PEO) and polybutadiene (PBu) composite elastomeric fibers with uniform fiber diameter and distribution are successfully fabricated. Thermomechanical behavior analyzed via frequency‐dependent dynamic mechanical analysis under cryogenic conditions shows a remarkable increase in decomposition temperatures (Tend) and storage and loss modulus at cryogenic temperatures, particularly when small amounts of CNTs are present. Dynamic mechanical treatment from 120 K to elevated temperatures yields a pronounced logarithmic increase in Tend by an increase of PEO content (from BEC1 to BEC4) compared to the treatment from 300 K. Through X‐ray diffraction, large shifts toward larger 2θ and formation of new crystals are observed, particularly for the BEC4 sample with high PEO content. Nanoparticles after cryo‐treatment linked with crystallinity are registered by ultra‐high resolution scanning electron microscopy. Improving the thermal and mechanical properties is critical in developing high‐performance composite fibers for cryogenic engineering applications, especially for future research to facilitate them in aerospace and low‐temperature medical and surgical treatments.
- 4 September 2022
- Published by Wiley in Polymers for Advanced Technologies
- Vol. 33 (12) , 3966-3976
Carbon nanotube‐polybutadiene‐poly(ethylene oxide)‐based composite fibers: Role of cryogenic treatment on intrinsic properties
The low‐temperature response and the notion of crystallization kinetics are critical for developing elastomeric composite fibers, thus the crystallization and mechanical properties are essential for the application of composites of polybutadiene at low temperatures. Despite the high amount of fiber joining and entanglement due to polymers' low glass transition, a defect‐free micro‐scale electrospun carbon nanotube (CNT)‐containing poly(ethylene oxide) (PEO) and polybutadiene (PBu) composite elastomeric fibers with uniform fiber diameter and distribution are successfully fabricated. Thermomechanical behavior analyzed via frequency‐dependent dynamic mechanical analysis under cryogenic conditions shows a remarkable increase in decomposition temperatures (Tend) and storage and loss modulus at cryogenic temperatures, particularly when small amounts of CNTs are present. Dynamic mechanical treatment from 120 K to elevated temperatures yields a pronounced logarithmic increase in Tend by an increase of PEO content (from BEC1 to BEC4) compared to the treatment from 300 K. Through X‐ray diffraction, large shifts toward larger 2θ and formation of new crystals are observed, particularly for the BEC4 sample with high PEO content. Nanoparticles after cryo‐treatment linked with crystallinity are registered by ultra‐high resolution scanning electron microscopy. Improving the thermal and mechanical properties is critical in developing high‐performance composite fibers for cryogenic engineering applications, especially for future research to facilitate them in aerospace and low‐temperature medical and surgical treatments.
- 1 July 2018
- Published by Elsevier in Chemosphere
- Vol. 202, 618-625
Investigation of applicability of Electro-Fenton method for the mineralization of naphthol blue black in water
- 1 July 2018
- Published by Elsevier in Chemosphere
- Vol. 202, 618-625
Investigation of applicability of Electro-Fenton method for the mineralization of naphthol blue black in water
- 10 April 2018
- Published by Elsevier in Current Pharmaceutical Analysis
- Vol. 14 (3) , 247-254
Preparation of Activated Disposable Pencil Graphite Electrode for the Selective and Sensitive Determination of a Fluoroquinolone Antibiotic: Levofloxacin
Background; Levofloxacin (LVX) is one of the fluoroquinolone antibiotics that possess a wide spectrum of bactericidal activity against both Gram-positive and Gram-negative bacteria. Because of its side effects and its potential towards the development of antibiotic resistance, determination of this antibiotic is very important. New methods which are superior properties than the conventional methods are needed in the determination of pharmaceuticals in different samples. Methods; An activated pencil graphite electrode (A-PGE) was prepared and its application in the voltammetric determination of LVX in pharmaceutical samples and body fluids was searched. Results; Oxidation peak currents of LVX were increased 40 times in the presence of A-PGE according to bare PGE. The highest voltammetric response of A-PGE towards LVX was achieved at pH value of 4. A wide linear range (0.01 – 2.5 μM) was observed between the oxidation peak currents and concentrations of LVX. Detection limit was calculated as 0.0075 μM. The inter-day (five days) precision of A-PGE was found to be 3.16%. Interference studies showed that A-PGE successfully discriminated the voltammetric response of LVX from that of many other structurally related substances such as ciprofloxacin, norfloxacin and enoxacin. Prepared A-PGE preserved 87% of its original activity towards LVX after a 2-month storage. Determination of LVX in blood serum, urine and pharmaceuticals were successfully achieved by A-PGE. Conclusion; The prepared A-PGE brings two important advantages. First one is the selective response of A-PGE towards LVX in the presence of other fluoroquinolone antibiotics (ciprofloxacin, enoxacin and norfloxacin). The other is the high sensitivity of A-PGE towards LVX having the detection limit of 0.0075 μM. In addition to the given advantages, its disposable character, low cost, commercial availability and easy preparation of A-PGE make this electrode as an important candidate in the fast and accurate determination of LVX.
- 10 April 2018
- Published by Elsevier in Current Pharmaceutical Analysis
- Vol. 14 (3) , 247-254
Preparation of Activated Disposable Pencil Graphite Electrode for the Selective and Sensitive Determination of a Fluoroquinolone Antibiotic: Levofloxacin
Background; Levofloxacin (LVX) is one of the fluoroquinolone antibiotics that possess a wide spectrum of bactericidal activity against both Gram-positive and Gram-negative bacteria. Because of its side effects and its potential towards the development of antibiotic resistance, determination of this antibiotic is very important. New methods which are superior properties than the conventional methods are needed in the determination of pharmaceuticals in different samples. Methods; An activated pencil graphite electrode (A-PGE) was prepared and its application in the voltammetric determination of LVX in pharmaceutical samples and body fluids was searched. Results; Oxidation peak currents of LVX were increased 40 times in the presence of A-PGE according to bare PGE. The highest voltammetric response of A-PGE towards LVX was achieved at pH value of 4. A wide linear range (0.01 – 2.5 μM) was observed between the oxidation peak currents and concentrations of LVX. Detection limit was calculated as 0.0075 μM. The inter-day (five days) precision of A-PGE was found to be 3.16%. Interference studies showed that A-PGE successfully discriminated the voltammetric response of LVX from that of many other structurally related substances such as ciprofloxacin, norfloxacin and enoxacin. Prepared A-PGE preserved 87% of its original activity towards LVX after a 2-month storage. Determination of LVX in blood serum, urine and pharmaceuticals were successfully achieved by A-PGE. Conclusion; The prepared A-PGE brings two important advantages. First one is the selective response of A-PGE towards LVX in the presence of other fluoroquinolone antibiotics (ciprofloxacin, enoxacin and norfloxacin). The other is the high sensitivity of A-PGE towards LVX having the detection limit of 0.0075 μM. In addition to the given advantages, its disposable character, low cost, commercial availability and easy preparation of A-PGE make this electrode as an important candidate in the fast and accurate determination of LVX.
- 1 February 2018
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 255, 1517-1524
Preparation of a double-step modified carbon paste electrode for the voltammetric determination of propham via bulk modification with fumed silica and drop-casting of maghemite-modified fumed silica nanocomposite
- 1 February 2018
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 255, 1517-1524
Preparation of a double-step modified carbon paste electrode for the voltammetric determination of propham via bulk modification with fumed silica and drop-casting of maghemite-modified fumed silica nanocomposite