Levente Molnár
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Levente Molnár has a total of 147 co-authors. Here are the top co-authors by number of shared publications:
- Béla Merkely
Heart and Vascular Center, Semmelweis University , Budapest
19 shared publications Endre Zima
Heart and Vascular Center, Semmelweis University, Budapest, Hungary
13 shared publications- Gábor Széplaki
Mater Private Hospital and Royal College of Surgeons in Ireland , Dublin
9 shared publications László Gellér
Heart and Vascular Center, Semmelweis University, Budapest, Hungary
9 shared publicationsBéla Merkely
Heart and Vascular Center, Semmelweis University , 68, Városmajor Street, 1122 Budapest , Hungary
7 shared publicationsSzabolcs Szilágyi
Semmelweis University Heart and Vascular Center Budapest Hungary
6 shared publications
Latest Publications
- Open Access
- 29 October 2024
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 26 (2) , 287-298
Prognostic and therapeutic implications of a low aortic valve calcium score in patients with low-gradient aortic stenosis
Aims: Low-gradient (LG) aortic stenosis (AS) poses a diagnostic challenge. Aortic valve calcium score (AVCS) assessment has emerged as a complementary diagnostic method when echocardiography provides discordant results. However, the diagnostic and prognostic values of AVCS in LGAS have not been thoroughly studied. Our aims in this study were to investigate the prognostic importance of AVCS in LGAS and to assess whether symptomatic patients with LGAS and low AVCS may benefit from aortic valve intervention (AVI). Methods and results: A total of 327 symptomatic patients (78.5 ± 7.3 years, 51% women) with severe AS defined by the aortic valve area who underwent computed tomography for transcatheter aortic valve intervention (TAVI) planning were enrolled. AVCS was measured. AVCS < 2000AU in men and < 1200 AU in women was considered a low AVCS. A total of 243 patients had high gradient (HG) and 84 had LGAS. A low AVCS was present in 25 (10%) patients with HG and 34 (40%) with LGAS. Over a median follow-up period of 4.9 years, 194 deaths occurred. In multivariate analysis, AVCS was a significant independent predictor of all-cause mortality among patients with HGAS [adjusted hazard ratio (aHR): 2.317; CI: 1.104–4.861; P = 0.026] but not among those with LGAS (aHR: 0.848; CI: 0.434–1.658; P = 0.630). After propensity score matching between patients who underwent AVI and those who were medically treated, AVI (94% TAVI) was a significant and independent predictor of survival among LGAS patients with a low AVCS even after adjustment for clinical variables (aHR: 0.102, CI: 0.028–0.369; P < 0.001). Conclusion: The prevalence of a low AVCS is much higher in patients with LGAS than in those with HGAS. In patients with symptomatic severe LGAS, a low AVCS does not entail a better prognosis. AVI is equally beneficial in LGAS patients with a high or low AVCS, similarly to those with HGAS.
- 29 October 2024
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 26 (2) , 287-298
Open AccessPrognostic and therapeutic implications of a low aortic valve calcium score in patients with low-gradient aortic stenosis
Aims: Low-gradient (LG) aortic stenosis (AS) poses a diagnostic challenge. Aortic valve calcium score (AVCS) assessment has emerged as a complementary diagnostic method when echocardiography provides discordant results. However, the diagnostic and prognostic values of AVCS in LGAS have not been thoroughly studied. Our aims in this study were to investigate the prognostic importance of AVCS in LGAS and to assess whether symptomatic patients with LGAS and low AVCS may benefit from aortic valve intervention (AVI). Methods and results: A total of 327 symptomatic patients (78.5 ± 7.3 years, 51% women) with severe AS defined by the aortic valve area who underwent computed tomography for transcatheter aortic valve intervention (TAVI) planning were enrolled. AVCS was measured. AVCS < 2000AU in men and < 1200 AU in women was considered a low AVCS. A total of 243 patients had high gradient (HG) and 84 had LGAS. A low AVCS was present in 25 (10%) patients with HG and 34 (40%) with LGAS. Over a median follow-up period of 4.9 years, 194 deaths occurred. In multivariate analysis, AVCS was a significant independent predictor of all-cause mortality among patients with HGAS [adjusted hazard ratio (aHR): 2.317; CI: 1.104–4.861; P = 0.026] but not among those with LGAS (aHR: 0.848; CI: 0.434–1.658; P = 0.630). After propensity score matching between patients who underwent AVI and those who were medically treated, AVI (94% TAVI) was a significant and independent predictor of survival among LGAS patients with a low AVCS even after adjustment for clinical variables (aHR: 0.102, CI: 0.028–0.369; P < 0.001). Conclusion: The prevalence of a low AVCS is much higher in patients with LGAS than in those with HGAS. In patients with symptomatic severe LGAS, a low AVCS does not entail a better prognosis. AVI is equally beneficial in LGAS patients with a high or low AVCS, similarly to those with HGAS.
- Open Access
- 21 December 2023
- Published by Springer Nature in GeroScience
- Vol. 46 (2) , 2671-2679
The prevalence of frailty and its effect on the outcome in cardiac resynchronization therapy patients
Frailty is a complex clinical syndrome associated with aging and comorbidities, which correlates with unfavorable outcomes. However, in heart failure patients, frailty is very common, data is scarce about those, who are eligible for Cardiac Resynchronization Therapy (CRT) implantation. We investigated the incidence of frailty and the association of Frailty Index (FI) with the outcome. Thirty baseline clinical parameters were used by the Rockwood cumulative deficit method to determine patients' FI in our single-center cohort. Based on previous studies, patients with FI ≤ 0.210 were considered as non-frail, those with FI 0.10–0.210 were classified in Frail-1, with FI > 0.10 in Frail-2 groups, respectively. Echocardiographic response after 12 months and all-cause mortality were investigated by frailty groups. Among 1004 included patients, 75 (7%) were considered Non-frail, 271 (27%) grouped in Frail-1, and 658 (66%) in Frail-2 with a median FI of 0.36 (0.28–0.43). Patients in Frail-2 group were older, with more comorbidities compared with non-frail patients or those in Group Frail-1. During the median follow-up time of 4.8 years, 29 (39%) patients died in the Non-frail, 140 (52%) in Frail-1, and 471 (72%) in the Frail-2 groups (log-rank p < 0.001). Group Frail-2 showed an unfavorable outcome compared to the non-frail (HR 2.49, 95%CI 1.92–3.22; p < 0.001) and the Frail-1 group (1.83, 95%CI 1.55–2.16; p < 0.001). In our HFrEF patients eligible for CRT implantation, patients were exceedingly vulnerable with a high prevalence of frailty. The calculated frailty index was associated with outcome and proved to be prevalent in individual risk stratification.
- 21 December 2023
- Published by Springer Nature in GeroScience
- Vol. 46 (2) , 2671-2679
Open AccessThe prevalence of frailty and its effect on the outcome in cardiac resynchronization therapy patients
Frailty is a complex clinical syndrome associated with aging and comorbidities, which correlates with unfavorable outcomes. However, in heart failure patients, frailty is very common, data is scarce about those, who are eligible for Cardiac Resynchronization Therapy (CRT) implantation. We investigated the incidence of frailty and the association of Frailty Index (FI) with the outcome. Thirty baseline clinical parameters were used by the Rockwood cumulative deficit method to determine patients' FI in our single-center cohort. Based on previous studies, patients with FI ≤ 0.210 were considered as non-frail, those with FI 0.10–0.210 were classified in Frail-1, with FI > 0.10 in Frail-2 groups, respectively. Echocardiographic response after 12 months and all-cause mortality were investigated by frailty groups. Among 1004 included patients, 75 (7%) were considered Non-frail, 271 (27%) grouped in Frail-1, and 658 (66%) in Frail-2 with a median FI of 0.36 (0.28–0.43). Patients in Frail-2 group were older, with more comorbidities compared with non-frail patients or those in Group Frail-1. During the median follow-up time of 4.8 years, 29 (39%) patients died in the Non-frail, 140 (52%) in Frail-1, and 471 (72%) in the Frail-2 groups (log-rank p < 0.001). Group Frail-2 showed an unfavorable outcome compared to the non-frail (HR 2.49, 95%CI 1.92–3.22; p < 0.001) and the Frail-1 group (1.83, 95%CI 1.55–2.16; p < 0.001). In our HFrEF patients eligible for CRT implantation, patients were exceedingly vulnerable with a high prevalence of frailty. The calculated frailty index was associated with outcome and proved to be prevalent in individual risk stratification.
- Open Access
- 24 May 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (Supplement)
Afterload dependence of right ventricular pacing-induced left ventricular dysfunction in patients with aortic stenosis undergoing transcatheter aortic valve implantation
Funding Acknowledgements: Type of funding sources: Public grant(s) – National budget only. Main funding source(s): TKP2021-EGA-23 János Bolyai Research Scholarship of the Hungarian Academy of Sciences. Introduction: Recent experimental data indicates that patients with left bundle branch block are particularly sensitive to increased arterial afterload. Nevertheless, whether the detrimental hemodynamic consequence of right ventricular pacing (RVP) is also associated with afterload dependency has not been investigated yet. Purpose: Hence, the present preliminary study aimed to examine the acute effect of RVP on left ventricular (LV) function in patients with aortic stenosis before (with elevated arterial afterload) and after (without elevated arterial afterload) transcatheter aortic valve implantation (TAVI). Methods: Patients with a previously implanted permanent pacemaker (PM) and significant aortic stenosis referred for TAVI at the Heart and Vascular Center of our university were screened for this observational study. Only those patients who had an intrinsic, regular, narrow QRS rhythm (including junctional escape rhythm) were included. Four patients with a DDD PM (with sick sinus syndrome and maintained AV conduction) and two patients with a VVI PM (with atrial fibrillation and AV block) were enrolled. Echocardiography was performed immediately before TAVI and on the second postoperative day. The ultrasound measurements were carried out during intrinsic, narrow QRS rhythm (80/min AAI pacing in patients with DDD PM and 30/min backup VVI pacing to allow the narrow QRS escape rhythm in patients with VVI PM) and during frequency-matched RVP with wide QRS (>150ms) (DDD pacing with a short AV interval ensuring ventricular capture or VVI pacing, respectively). From the sonographic recordings, speckle-tracking echocardiography-derived global myocardial work index (GMWI) was calculated by commercially available software to assess LV function. Results: TAVI resulted in decreased mean aortic gradient (35.4±3.6 mmHg vs. 5.3±1.4 mmHg before vs. after TAVI, P<0.001) indicating successful alleviation of the increased arterial afterload. Compared to the intrinsic, narrow QRS rhythm, RVP reduced GMWI before and after TAVI as well. Nevertheless, a significant reduction was only noted when the increased afterload was present (pre-TAVI GMWI: 1710±169 vs. 1170±199mmHg%, P=0.008), while following pressure unloading only a strong tendency could be observed (post-TAVI GMWI: 1127±76 vs. 865±83mmHg%, P=0.065). Conclusion: Our preliminary results indicate that RVP-induced LV dysfunction might be afterload dependent. Hence, in patients with aortic stenosis and a high percentage of ventricular pacing, afterload reduction could entail a great clinical benefit.
- 24 May 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (Supplement)
Open AccessAfterload dependence of right ventricular pacing-induced left ventricular dysfunction in patients with aortic stenosis undergoing transcatheter aortic valve implantation
Funding Acknowledgements: Type of funding sources: Public grant(s) – National budget only. Main funding source(s): TKP2021-EGA-23 János Bolyai Research Scholarship of the Hungarian Academy of Sciences. Introduction: Recent experimental data indicates that patients with left bundle branch block are particularly sensitive to increased arterial afterload. Nevertheless, whether the detrimental hemodynamic consequence of right ventricular pacing (RVP) is also associated with afterload dependency has not been investigated yet. Purpose: Hence, the present preliminary study aimed to examine the acute effect of RVP on left ventricular (LV) function in patients with aortic stenosis before (with elevated arterial afterload) and after (without elevated arterial afterload) transcatheter aortic valve implantation (TAVI). Methods: Patients with a previously implanted permanent pacemaker (PM) and significant aortic stenosis referred for TAVI at the Heart and Vascular Center of our university were screened for this observational study. Only those patients who had an intrinsic, regular, narrow QRS rhythm (including junctional escape rhythm) were included. Four patients with a DDD PM (with sick sinus syndrome and maintained AV conduction) and two patients with a VVI PM (with atrial fibrillation and AV block) were enrolled. Echocardiography was performed immediately before TAVI and on the second postoperative day. The ultrasound measurements were carried out during intrinsic, narrow QRS rhythm (80/min AAI pacing in patients with DDD PM and 30/min backup VVI pacing to allow the narrow QRS escape rhythm in patients with VVI PM) and during frequency-matched RVP with wide QRS (>150ms) (DDD pacing with a short AV interval ensuring ventricular capture or VVI pacing, respectively). From the sonographic recordings, speckle-tracking echocardiography-derived global myocardial work index (GMWI) was calculated by commercially available software to assess LV function. Results: TAVI resulted in decreased mean aortic gradient (35.4±3.6 mmHg vs. 5.3±1.4 mmHg before vs. after TAVI, P<0.001) indicating successful alleviation of the increased arterial afterload. Compared to the intrinsic, narrow QRS rhythm, RVP reduced GMWI before and after TAVI as well. Nevertheless, a significant reduction was only noted when the increased afterload was present (pre-TAVI GMWI: 1710±169 vs. 1170±199mmHg%, P=0.008), while following pressure unloading only a strong tendency could be observed (post-TAVI GMWI: 1127±76 vs. 865±83mmHg%, P=0.065). Conclusion: Our preliminary results indicate that RVP-induced LV dysfunction might be afterload dependent. Hence, in patients with aortic stenosis and a high percentage of ventricular pacing, afterload reduction could entail a great clinical benefit.
- Open Access
- 1 October 2022
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 43 (Supplement)
Right ventricular mechanics and its association with symptoms in transcatheter aortic valve replacement candidates: a three-dimensional echocardiography study
Aortic valve stenosis is one of the most prevalent valvular disease with significant clinical burden. While it is initially a disorder of the left ventricle (LV), long-term effects of the disease also affect the right ventricle (RV) as well. Nevertheless, data are scarce regarding the changes of RV mechanics and their association with symptomatic status of the patients. 3D echocardiography allows a more detailed assessment of the RV, which may unveil distinct changes of its morphology and function in this clinical setting. Accordingly, our aim was to examine LV and RV mechanics in TAVR candidate patients with severe aortic stenosis using three-dimensional (3D) echocardiography. Seventy patients (51% male, age: 80±6 years) were enrolled. Detailed medical history and symptomatic status were obtained. Beyond conventional transthoracic echocardiographic protocol, 3D loops were also acquired. We measured 3D LV and RV end-diastolic volume indexed to body surface area (EDVi), ejection fraction (EF) and global longitudinal (GLS) using dedicated software. Furthermore, we have determined 3D RV global longitudinal (RV GLS) and circumferential strain (RV GCS) using the ReVISION method. LV EF (r=0.28, p2, p=0.47), LV EF (47±15 vs. 51±10%, p=0.14) and LV GLS (−13.6±4.8 vs. −14.8±2.6%, p=0.25) to those who did not mention these complaints. On the other hand, patients with angina or syncope in their medical history had significantly lower RV EDVi (58±13 vs. 70±23 mL/m2, p<0.05), while having significantly higher RV EF (46±10 vs. 52±7%, p<0.05). Moreover, symptomatic patients had significantly lower RV GCS (−15.7±5.6 vs. −19.6±5.3%, p<0.01), while RV GLS did not differ (−15.8±4.8 vs. −17.4±4.1%, p=0.17). Patients with severe aortic stenosis have marked changes in not only the LV, but the RV mechanics as well. While the symptomatic status does not seem to be associated with LV morphology and function, patients with angina or syncope had distinct changes in RV size and the contraction pattern of the chamber. Type of funding sources: None.
- 1 October 2022
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 43 (Supplement)
Open AccessRight ventricular mechanics and its association with symptoms in transcatheter aortic valve replacement candidates: a three-dimensional echocardiography study
Aortic valve stenosis is one of the most prevalent valvular disease with significant clinical burden. While it is initially a disorder of the left ventricle (LV), long-term effects of the disease also affect the right ventricle (RV) as well. Nevertheless, data are scarce regarding the changes of RV mechanics and their association with symptomatic status of the patients. 3D echocardiography allows a more detailed assessment of the RV, which may unveil distinct changes of its morphology and function in this clinical setting. Accordingly, our aim was to examine LV and RV mechanics in TAVR candidate patients with severe aortic stenosis using three-dimensional (3D) echocardiography. Seventy patients (51% male, age: 80±6 years) were enrolled. Detailed medical history and symptomatic status were obtained. Beyond conventional transthoracic echocardiographic protocol, 3D loops were also acquired. We measured 3D LV and RV end-diastolic volume indexed to body surface area (EDVi), ejection fraction (EF) and global longitudinal (GLS) using dedicated software. Furthermore, we have determined 3D RV global longitudinal (RV GLS) and circumferential strain (RV GCS) using the ReVISION method. LV EF (r=0.28, p2, p=0.47), LV EF (47±15 vs. 51±10%, p=0.14) and LV GLS (−13.6±4.8 vs. −14.8±2.6%, p=0.25) to those who did not mention these complaints. On the other hand, patients with angina or syncope in their medical history had significantly lower RV EDVi (58±13 vs. 70±23 mL/m2, p<0.05), while having significantly higher RV EF (46±10 vs. 52±7%, p<0.05). Moreover, symptomatic patients had significantly lower RV GCS (−15.7±5.6 vs. −19.6±5.3%, p<0.01), while RV GLS did not differ (−15.8±4.8 vs. −17.4±4.1%, p=0.17). Patients with severe aortic stenosis have marked changes in not only the LV, but the RV mechanics as well. While the symptomatic status does not seem to be associated with LV morphology and function, patients with angina or syncope had distinct changes in RV size and the contraction pattern of the chamber. Type of funding sources: None.
- Open Access
- 1 October 2022
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 43 (Supplement)
Clinical determinants of non-invasive global myocardial work index before and after transcatheter aortic valve implantation: a prospective study
: The estimation of non-invasive global myocardial work indices is a novel method of the left ventricular (LV) functional assessment, which may overcome the load-sensitvity of the traditional functional measures. The diagnostic and prognostic role of this approach may gain particular importance in pressure overload states, such as in patients with severe aortic stenosis. However, the longitudinal changes of this recently introduced measure are scarcely investigated, and data are also lacking about the main determinants of these measures. Accordingly, our aim was to investigate the clinical determinants of preoperative and also postoperative GMWI in patients undergoing transcatheter aortic valve replacement (TAVR). Fifty patients (62% male, age: 78±5 years) were enrolled. Prior to the procedure, subjects underwent echocardiographic investigation and the detailed medical history was also recorded. Speckle-tracking analysis was performed and global longitudinal strain (GLS) was measured. LV pressure curve was estimated by adding the mean aortic valve gradient to the systolic blood pressure. Using these measures, global myocardial work index (GMWI) and global constructive work index (CMWI) was quantified by commercially available software. A 6 months follow-up examination was also performed and at that time point we determined the aforementioned parameters. At follow-up, GLS has significantly increased (−13.0±4.1 vs. −14.8±3.8%; p<0.001), while GMWI was significantly lower compared to baseline (1789±748 vs. 1506±561 mmHg%, p<0.01). CMWI did not differ between the two time points (2309±782 vs. 2086±609 mmHg%, p=0.11). Using multivariable analysis, age (β=0.30; p<0.05) preoperative New York Heart Association (NYHA) class (β=−0.48; p<0.001) and having a pacemaker (β=−0.44; p<0.01) were found to be independent predictors of the preoperative GMWI (R2=0.39; overall p<0.001). On the other hand, postoperative GMWI was determined (R2=0.48; overall p<0.001) by gender (β=−0.25; p<0.05), the presence of diabetes mellitus (β=−0.37; p<0.01) and also by having a pacemaker (β=−0.38; p<0.01). TAVR significantly alters LV functional measures. Different clinical factors influence GMWI before and after the procedure: age, NYHA class-based symptom severity and having a pacemaker were found to be independently associated with preoperative GMWI, while gender, the presence of diabetes mellitus and pacemaker device are the most important clinical determinants of the postoperative GMWI value. Funding Acknowledgement: Type of funding sources: None.
- 1 October 2022
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 43 (Supplement)
Open AccessClinical determinants of non-invasive global myocardial work index before and after transcatheter aortic valve implantation: a prospective study
: The estimation of non-invasive global myocardial work indices is a novel method of the left ventricular (LV) functional assessment, which may overcome the load-sensitvity of the traditional functional measures. The diagnostic and prognostic role of this approach may gain particular importance in pressure overload states, such as in patients with severe aortic stenosis. However, the longitudinal changes of this recently introduced measure are scarcely investigated, and data are also lacking about the main determinants of these measures. Accordingly, our aim was to investigate the clinical determinants of preoperative and also postoperative GMWI in patients undergoing transcatheter aortic valve replacement (TAVR). Fifty patients (62% male, age: 78±5 years) were enrolled. Prior to the procedure, subjects underwent echocardiographic investigation and the detailed medical history was also recorded. Speckle-tracking analysis was performed and global longitudinal strain (GLS) was measured. LV pressure curve was estimated by adding the mean aortic valve gradient to the systolic blood pressure. Using these measures, global myocardial work index (GMWI) and global constructive work index (CMWI) was quantified by commercially available software. A 6 months follow-up examination was also performed and at that time point we determined the aforementioned parameters. At follow-up, GLS has significantly increased (−13.0±4.1 vs. −14.8±3.8%; p<0.001), while GMWI was significantly lower compared to baseline (1789±748 vs. 1506±561 mmHg%, p<0.01). CMWI did not differ between the two time points (2309±782 vs. 2086±609 mmHg%, p=0.11). Using multivariable analysis, age (β=0.30; p<0.05) preoperative New York Heart Association (NYHA) class (β=−0.48; p<0.001) and having a pacemaker (β=−0.44; p<0.01) were found to be independent predictors of the preoperative GMWI (R2=0.39; overall p<0.001). On the other hand, postoperative GMWI was determined (R2=0.48; overall p<0.001) by gender (β=−0.25; p<0.05), the presence of diabetes mellitus (β=−0.37; p<0.01) and also by having a pacemaker (β=−0.38; p<0.01). TAVR significantly alters LV functional measures. Different clinical factors influence GMWI before and after the procedure: age, NYHA class-based symptom severity and having a pacemaker were found to be independently associated with preoperative GMWI, while gender, the presence of diabetes mellitus and pacemaker device are the most important clinical determinants of the postoperative GMWI value. Funding Acknowledgement: Type of funding sources: None.
- 28 September 2022
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 23 (12) , 1584-1595
Subclinical leaflet thrombosis after transcatheter aortic valve implantation is associated with silent brain injury on brain magnetic resonance imaging
Whether hypoattenuated leaflet thickening (HALT) following transcatheter aortic valve implantation (TAVI) carries a risk of subclinical brain injury (SBI) is unknown. We investigated whether HALT is associated with SBI detected on magnetic resonance imaging (MRI), and whether post-TAVI SBI impacts the patients’ cognition and outcome. We prospectively enrolled 153 patients (age: 78.1 ± 6.3 years; female 44%) who underwent TAVI. Brain MRI was performed shortly post-TAVI and 6 months later to assess the occurrence of acute silent cerebral ischaemic lesions (SCIL) and chronic white matter hyperintensities (WMH). HALT was screened by cardiac computed tomography (CT) angiography (CTA) 6 months post-TAVI. Neurocognitive evaluation was performed before, shortly after and 6 months following TAVI. At 6 months, 115 patients had diagnostic CTA and 10 had HALT. HALT status, baseline, and follow-up MRIs were available in 91 cases. At 6 months, new SCIL was evident in 16%, new WMH in 66%. New WMH was more frequent (100 vs. 62%; P = 0.047) with higher median volume (319 vs. 50 mm3; P = 0.039) among HALT-patients. In uni- and multivariate analysis, HALT was associated with new WMH volume (beta: 0.72; 95%CI: 0.2–1.39; P = 0.009). The patients’ cognitive trajectory from pre-TAVI to 6 months showed significant association with the 6-month SCIL volume (beta: −4.69; 95%CI: −9.13 to 0.27; P = 0.038), but was not related to the presence or volume of new WMH. During a 3.1-year follow-up, neither HALT [hazard ratio (HR): 0.86; 95%CI: 0.202–3.687; P = 0.84], nor the related WMH burden (HR: 1.09; 95%CI: 0.701–1.680; P = 0.71) was related with increased mortality. At 6 months post-TAVI, HALT was linked with greater WMH burden, but did not carry an increased risk of cognitive decline or mortality over a 3.1-year follow-up (NCT02826200).
- 28 September 2022
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 23 (12) , 1584-1595
Subclinical leaflet thrombosis after transcatheter aortic valve implantation is associated with silent brain injury on brain magnetic resonance imaging
Whether hypoattenuated leaflet thickening (HALT) following transcatheter aortic valve implantation (TAVI) carries a risk of subclinical brain injury (SBI) is unknown. We investigated whether HALT is associated with SBI detected on magnetic resonance imaging (MRI), and whether post-TAVI SBI impacts the patients’ cognition and outcome. We prospectively enrolled 153 patients (age: 78.1 ± 6.3 years; female 44%) who underwent TAVI. Brain MRI was performed shortly post-TAVI and 6 months later to assess the occurrence of acute silent cerebral ischaemic lesions (SCIL) and chronic white matter hyperintensities (WMH). HALT was screened by cardiac computed tomography (CT) angiography (CTA) 6 months post-TAVI. Neurocognitive evaluation was performed before, shortly after and 6 months following TAVI. At 6 months, 115 patients had diagnostic CTA and 10 had HALT. HALT status, baseline, and follow-up MRIs were available in 91 cases. At 6 months, new SCIL was evident in 16%, new WMH in 66%. New WMH was more frequent (100 vs. 62%; P = 0.047) with higher median volume (319 vs. 50 mm3; P = 0.039) among HALT-patients. In uni- and multivariate analysis, HALT was associated with new WMH volume (beta: 0.72; 95%CI: 0.2–1.39; P = 0.009). The patients’ cognitive trajectory from pre-TAVI to 6 months showed significant association with the 6-month SCIL volume (beta: −4.69; 95%CI: −9.13 to 0.27; P = 0.038), but was not related to the presence or volume of new WMH. During a 3.1-year follow-up, neither HALT [hazard ratio (HR): 0.86; 95%CI: 0.202–3.687; P = 0.84], nor the related WMH burden (HR: 1.09; 95%CI: 0.701–1.680; P = 0.71) was related with increased mortality. At 6 months post-TAVI, HALT was linked with greater WMH burden, but did not carry an increased risk of cognitive decline or mortality over a 3.1-year follow-up (NCT02826200).
- Open Access
- 18 May 2022
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 24 (Supplement)
Changes of the non-invasive myocardial work in patient undergoing transcatheter aortic valve replacement: the influence of left bundle branch block
Funding Acknowledgements: Type of funding sources: None. Patients with left bundle branch block (LBBB) are known to have substantially increased afterload sensitivity. It gains particular importance in subjects with aortic stenosis: patients with pre-existing LBBB may benefit more from interventions such as transcatheter aortic valve replacement (TAVR) by an effective and rapid reduction of the left ventricular (LV) pressures. Accordingly, our aim was to investigate the changes of LV myocardial work indices in patients undergoing TAVR by the presence of preoperative LBBB. Non-invasive myocardial work indices are novel echocardiographic parameters which adjust LV deformation to the instantaneous LV pressure, overcoming the the load-sensitivity of the traditional LV functional measures. Thirty patients undergoing TAVR were enrolled (37% female; age: 78±6 years; aortic valve area [AVA]: 0.7±0.3 cm2). Fourteen patients (47%; LBBB group) showed LBBB pattern on ECG, by demonstrating native LBBB (n=6; 20%) or having ventricular pacing dependency (n=8; 27%), while 16 patients had narrow QRS (53%; non-LBBB group). Prior to the procedure, subjects underwent a detailed echocardiographic investigation. Speckle-tracking analysis was performed and global longitudinal strain (GLS) was measured. LV pressure curve was estimated by adding the mean aortic valve gradient to the aortic systolic pressure. Using these measures, LV global constructive work index (CMWI) and global work efficiency (GWE). were quantified by commercially available software. A 6 months follow-up examination was also performed and at that time point we determined the aforementioned parameters. As expected, AVA significantly improved after the procedure in the pooled study group (1.8±0.4 cm2; p<0.001). GLS also significantly increased (-13.2±4.2 vs. -15.2±3.9 %; p<0.01), while CMWI only showed a tendential decrease (2422±788 vs. 2166±640 mmHg%; p=NS) at the follow-up. GLS (-10.6±3.7 vs. -15.5±3.4%; p<0.001), CMWI (1877±679 vs. 2898±529 mmHg%; p<0.001), and also GWE (82±9 vs. 91±4%; p<0.01) was significantly lower in the LBBB-group compared to the non-LBBB patients. At the follow-up, GLS was still significantly lower in the LBBB patients (-13.2±4.6 vs. -16.9±2.1%; p<0.01), however, CMWI was comparable between the two groups (1956±776 vs. 2350±439 mmHg%, p=NS). Pressure overload of the LV may affect patients with LBBB substantially more than subjects without it. TAVR causes an immediate and significant decrease in the LV afterload, which results in a more pronounced improvement in the LBBB group compared to those with no LBBB.
- 18 May 2022
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 24 (Supplement)
Open AccessChanges of the non-invasive myocardial work in patient undergoing transcatheter aortic valve replacement: the influence of left bundle branch block
Funding Acknowledgements: Type of funding sources: None. Patients with left bundle branch block (LBBB) are known to have substantially increased afterload sensitivity. It gains particular importance in subjects with aortic stenosis: patients with pre-existing LBBB may benefit more from interventions such as transcatheter aortic valve replacement (TAVR) by an effective and rapid reduction of the left ventricular (LV) pressures. Accordingly, our aim was to investigate the changes of LV myocardial work indices in patients undergoing TAVR by the presence of preoperative LBBB. Non-invasive myocardial work indices are novel echocardiographic parameters which adjust LV deformation to the instantaneous LV pressure, overcoming the the load-sensitivity of the traditional LV functional measures. Thirty patients undergoing TAVR were enrolled (37% female; age: 78±6 years; aortic valve area [AVA]: 0.7±0.3 cm2). Fourteen patients (47%; LBBB group) showed LBBB pattern on ECG, by demonstrating native LBBB (n=6; 20%) or having ventricular pacing dependency (n=8; 27%), while 16 patients had narrow QRS (53%; non-LBBB group). Prior to the procedure, subjects underwent a detailed echocardiographic investigation. Speckle-tracking analysis was performed and global longitudinal strain (GLS) was measured. LV pressure curve was estimated by adding the mean aortic valve gradient to the aortic systolic pressure. Using these measures, LV global constructive work index (CMWI) and global work efficiency (GWE). were quantified by commercially available software. A 6 months follow-up examination was also performed and at that time point we determined the aforementioned parameters. As expected, AVA significantly improved after the procedure in the pooled study group (1.8±0.4 cm2; p<0.001). GLS also significantly increased (-13.2±4.2 vs. -15.2±3.9 %; p<0.01), while CMWI only showed a tendential decrease (2422±788 vs. 2166±640 mmHg%; p=NS) at the follow-up. GLS (-10.6±3.7 vs. -15.5±3.4%; p<0.001), CMWI (1877±679 vs. 2898±529 mmHg%; p<0.001), and also GWE (82±9 vs. 91±4%; p<0.01) was significantly lower in the LBBB-group compared to the non-LBBB patients. At the follow-up, GLS was still significantly lower in the LBBB patients (-13.2±4.6 vs. -16.9±2.1%; p<0.01), however, CMWI was comparable between the two groups (1956±776 vs. 2350±439 mmHg%, p=NS). Pressure overload of the LV may affect patients with LBBB substantially more than subjects without it. TAVR causes an immediate and significant decrease in the LV afterload, which results in a more pronounced improvement in the LBBB group compared to those with no LBBB.
- Open Access
- 25 March 2017
- Published by Akademiai Kiado Zrt. in Interventional Medicine and Applied Science
- Vol. 9 (1) , 1-8
The impact of cardiac resynchronization therapy on routine laboratory parameters
Cardiac resynchronization therapy (CRT) in chronic heart failure has been shown to improve mortality and morbidity. However, comprehensive data are not available as concerns how circulating biomarkers reflecting different organ functions, such as serum uric acid, blood urea nitrogen (BUN), albumin, cholesterol, or various liver enzymes, change over time as a consequence of CRT. The aim of this prospective study was to overview these possible changes. A total of 20 routine laboratory parameters were measured in 122 control subjects and in 129 patients with chronic heart failure before CRT, 6 months, and 2 years later. The levels of serum uric acid [before: 432 (331–516) mmol/L, 6-month: 372 (304–452) mmol/L, 2-year: 340 (290–433) mmol/L; p < 0.001] and BUN [8.3 (6.4–11.5) mmol/L, 8.0 (6.3–11.1) mmol/L, 6.8 (5.0–9.7) mmol/L; p < 0.001) reduced statistically significant. Total bilirubin underwent reduction [16 (11–23) μmol/L, 11 (7–14) μmol/L, 8 (7–13) μmol/L; p < 0.001], while albumin increased [45 (43–48) g/L, 46 (44–48) g/L, 46 (43–48) g/L; p = 0.04]. Cholesterol concentrations elevated [4.3 (3.6–5.0) mmol/L, 4.5 (3.8–5.1) mmol/L, 4.6 (3.8–5.4) mmol/L; p < 0.001] and glucose decreased [6.2 (5.6–7.2) mmol/L, 5.9 (5.1–6.7) mmol/L, 5.7 (5.1–6.8) mmol/L; p < 0.001]. CRT influences the levels of routinely used biomarkers suggesting improvements in renal function, liver capacity, and metabolic changes. These changes could mirror the multiorgan improvement after CRT.
- 25 March 2017
- Published by Akademiai Kiado Zrt. in Interventional Medicine and Applied Science
- Vol. 9 (1) , 1-8
Open AccessThe impact of cardiac resynchronization therapy on routine laboratory parameters
Cardiac resynchronization therapy (CRT) in chronic heart failure has been shown to improve mortality and morbidity. However, comprehensive data are not available as concerns how circulating biomarkers reflecting different organ functions, such as serum uric acid, blood urea nitrogen (BUN), albumin, cholesterol, or various liver enzymes, change over time as a consequence of CRT. The aim of this prospective study was to overview these possible changes. A total of 20 routine laboratory parameters were measured in 122 control subjects and in 129 patients with chronic heart failure before CRT, 6 months, and 2 years later. The levels of serum uric acid [before: 432 (331–516) mmol/L, 6-month: 372 (304–452) mmol/L, 2-year: 340 (290–433) mmol/L; p < 0.001] and BUN [8.3 (6.4–11.5) mmol/L, 8.0 (6.3–11.1) mmol/L, 6.8 (5.0–9.7) mmol/L; p < 0.001) reduced statistically significant. Total bilirubin underwent reduction [16 (11–23) μmol/L, 11 (7–14) μmol/L, 8 (7–13) μmol/L; p < 0.001], while albumin increased [45 (43–48) g/L, 46 (44–48) g/L, 46 (43–48) g/L; p = 0.04]. Cholesterol concentrations elevated [4.3 (3.6–5.0) mmol/L, 4.5 (3.8–5.1) mmol/L, 4.6 (3.8–5.4) mmol/L; p < 0.001] and glucose decreased [6.2 (5.6–7.2) mmol/L, 5.9 (5.1–6.7) mmol/L, 5.7 (5.1–6.8) mmol/L; p < 0.001]. CRT influences the levels of routinely used biomarkers suggesting improvements in renal function, liver capacity, and metabolic changes. These changes could mirror the multiorgan improvement after CRT.
- 23 March 2017
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 40 (5) , 488-493
Minimal Invasive Left Ventricular Lead Repositioning is Safe and Effective in Distal Left Ventricular Lead Positions
- 23 March 2017
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 40 (5) , 488-493
Minimal Invasive Left Ventricular Lead Repositioning is Safe and Effective in Distal Left Ventricular Lead Positions