Prabir Kumar Roy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Prabir Kumar Roy has a total of 387 co-authors. Here are the top co-authors by number of shared publications:
- Erik P. Gilson
Princeton Plasma Physics Laboratory, Princeton, NJ, United States of America
27 shared publications E. Henestroza
Lawrence Berkeley National Laboratory
23 shared publications- Matthaeus Leitner
Lawrence Berkeley National Laboratory, Berkeley, CA 94720
23 shared publications - John J. Barnard
Lawrence Livermore National Laboratory 1 , Livermore, California 94550, USA
22 shared publications - Adam B. Sefkow
University of Rochester
21 shared publications F.M. Bieniosek
Lawrence Berkeley National Laboratory
17 shared publications
Latest Publications
- Open Access
- 9 September 2026
- Published by MDPI AG in Instruments
- Vol. 10 (3) , 45
Small Accelerators, Big Impact
Particle accelerators have become indispensable tools in fundamental charged-particle and beam-physics research, medical diagnostics and therapy, security screening, and many other applications. A small number of large, GeV-scale machines, often called “Big Science,” drive scientific discovery, while thousands of small accelerators serve everyday needs, primarily as X-ray sources when an electron beam is used. When an electron beam in the keV–MeV range strikes a high-Z (high-atomic-number) target material, it produces bremsstrahlung photons, whose interaction with matter is governed by the photoelectric effect, Compton scattering, and pair production, each dominant in a distinct energy regime that also depends on the atomic number of the absorbing material. A small accelerator can generate such significant effects if the energy and material parameters are properly matched, and these interactions can be exploited to generate material-specific signatures. Ion beams, on the other hand, deposit energy in materials and are used for gamma and neutron production, microstructure analysis, and many other applications. Here we review the operating principles of several small accelerators and their potential applications, offering a unified perspective on their role in contemporary science and technology.
- 9 September 2026
- Published by MDPI AG in Instruments
- Vol. 10 (3) , 45
Open AccessSmall Accelerators, Big Impact
Particle accelerators have become indispensable tools in fundamental charged-particle and beam-physics research, medical diagnostics and therapy, security screening, and many other applications. A small number of large, GeV-scale machines, often called “Big Science,” drive scientific discovery, while thousands of small accelerators serve everyday needs, primarily as X-ray sources when an electron beam is used. When an electron beam in the keV–MeV range strikes a high-Z (high-atomic-number) target material, it produces bremsstrahlung photons, whose interaction with matter is governed by the photoelectric effect, Compton scattering, and pair production, each dominant in a distinct energy regime that also depends on the atomic number of the absorbing material. A small accelerator can generate such significant effects if the energy and material parameters are properly matched, and these interactions can be exploited to generate material-specific signatures. Ion beams, on the other hand, deposit energy in materials and are used for gamma and neutron production, microstructure analysis, and many other applications. Here we review the operating principles of several small accelerators and their potential applications, offering a unified perspective on their role in contemporary science and technology.
- Open Access
- 1 September 2020
- Published by AIP Publishing in AIP Advances
- Vol. 10 (9) , 095023
Proton beam position measurement in air using a BPM
A Beam Position Monitor (BPM) is potentially useful to measure the position and phase of the beam in air in a non-destructive way. An air-gap BPM in experiments, such as beam-induced radioactive waste management and dynamic radiography applications, where a so-called air gap is needed, can be utilized to measure the beam position and phase. In this study, a stripline BPM was used in the air-gap of an 800 MeV proton beam transport line. The downstream end of the primary beamline exit window was made of a thin aluminum plate and allowed the beam to travel 1.2 m in ambient air before re-entering into a vacuum drift section. Such a configuration was arranged to examine the BPM effectiveness in atmospheric temperature and pressure where ionization of air occurs. In this study, a high energy (800 MeV), high current (0.6 A beam peak current/pulse) proton beam of 5 mm radius was transported in the air. The beam position relative to the axis was measured by detecting the signature of the beam in a nanosecond scale. This nanosecond scale detection ability was useful to identify other signals such as plasma effects. The BPM signals were processed at a frequency of 201 MHz; thus, one gets a stronger response in a stripline pattern as it was used in this study instead of a dot-type BPM. Experimental data show that the BPM works well in air, but ionization of air or plasma formation could not be measured over the BPM signal. The design, construction, and performance of a BPM in air environment are presented.
- 1 September 2020
- Published by AIP Publishing in AIP Advances
- Vol. 10 (9) , 095023
Open AccessProton beam position measurement in air using a BPM
A Beam Position Monitor (BPM) is potentially useful to measure the position and phase of the beam in air in a non-destructive way. An air-gap BPM in experiments, such as beam-induced radioactive waste management and dynamic radiography applications, where a so-called air gap is needed, can be utilized to measure the beam position and phase. In this study, a stripline BPM was used in the air-gap of an 800 MeV proton beam transport line. The downstream end of the primary beamline exit window was made of a thin aluminum plate and allowed the beam to travel 1.2 m in ambient air before re-entering into a vacuum drift section. Such a configuration was arranged to examine the BPM effectiveness in atmospheric temperature and pressure where ionization of air occurs. In this study, a high energy (800 MeV), high current (0.6 A beam peak current/pulse) proton beam of 5 mm radius was transported in the air. The beam position relative to the axis was measured by detecting the signature of the beam in a nanosecond scale. This nanosecond scale detection ability was useful to identify other signals such as plasma effects. The BPM signals were processed at a frequency of 201 MHz; thus, one gets a stronger response in a stripline pattern as it was used in this study instead of a dot-type BPM. Experimental data show that the BPM works well in air, but ionization of air or plasma formation could not be measured over the BPM signal. The design, construction, and performance of a BPM in air environment are presented.
- 3 August 2020
- Published by Office of Scientific and Technical Information (OSTI)
Optimization of a buncher for High Energy H- Beam Transport [Slides]
The U.S. Department of Energy's Office of Scientific and Technical Information
- 3 August 2020
- Published by Office of Scientific and Technical Information (OSTI)
Optimization of a buncher for High Energy H- Beam Transport [Slides]
The U.S. Department of Energy's Office of Scientific and Technical Information
- Open Access
- 1 September 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1067 (6) , 062002
Comparison of profile measurements and TRANSPORT beam envelope predictions along the 80-m LANSCE pRad beamline
Here we report a comparison between the simulation of beam phase-space and profile distributions with diagnostic measurements. TRANSPORT, a particle transport code, was used for the prediction of a 800 MeV proton beam envelope from the end of the linac to the proton radiography (pRad) facility (a total length of 80 meters). The beam profile was measured at key positions along the beamline using wire scanners and gated CCD camera systems. These measurements were compared to their respective points along the simulated beamline. The predicted beam envelope and measured data correspond within expected errors.
- 1 September 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1067 (6) , 062002
Open AccessComparison of profile measurements and TRANSPORT beam envelope predictions along the 80-m LANSCE pRad beamline
Here we report a comparison between the simulation of beam phase-space and profile distributions with diagnostic measurements. TRANSPORT, a particle transport code, was used for the prediction of a 800 MeV proton beam envelope from the end of the linac to the proton radiography (pRad) facility (a total length of 80 meters). The beam profile was measured at key positions along the beamline using wire scanners and gated CCD camera systems. These measurements were compared to their respective points along the simulated beamline. The predicted beam envelope and measured data correspond within expected errors.
- 26 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 63 (2) , 854-860
A Multi-Pinhole Faraday Cup Device for Measurement of Discrete Charge Distribution of Heavy and Light Ions
A new multi-pinhole Faraday cup (MPFC) device was designed, fabricated and tested to measure ion beam uniformity over a range of centimeters. There are 32 collectors within the device, and each of those is used as an individual Faraday cup to measure a fraction of the beam current. Experimental data show that the device is capable of measuring a charged particles distribution - either in the form of a raster scanned focused beam or a defocused beam.
- 26 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 63 (2) , 854-860
A Multi-Pinhole Faraday Cup Device for Measurement of Discrete Charge Distribution of Heavy and Light Ions
A new multi-pinhole Faraday cup (MPFC) device was designed, fabricated and tested to measure ion beam uniformity over a range of centimeters. There are 32 collectors within the device, and each of those is used as an individual Faraday cup to measure a fraction of the beam current. Experimental data show that the device is capable of measuring a charged particles distribution - either in the form of a raster scanned focused beam or a defocused beam.
- 1 January 2015
- Published by AIP Publishing in Physics of Plasmas
- Vol. 22 (1) , 013104
Intense ion beam neutralization using underdense background plasma
Producing an overdense background plasma for neutralization purposes with a density that is high compared to the beam density is not always experimentally possible. We show that even an underdense background plasma with a small relative density can achieve high neutralization of intense ion beam pulses. Using particle-in-cell simulations, we show that if the total plasma electron charge is not sufficient to neutralize the beam charge, electron emitters are necessary for effective neutralization but are not needed if the plasma volume is so large that the total available charge in the electrons exceeds that of the ion beam. Several regimes of possible underdense/tenuous neutralization plasma densities are investigated with and without electron emitters or dense plasma at periphery regions, including the case of electron emitters without plasma, which does not effectively neutralize the beam. Over 95% neutralization is achieved for even very underdense background plasma with plasma density 1/15th the beam density. We compare results of particle-in-cell simulations with an analytic model of neutralization and find close agreement with the particle-in-cell simulations. Further, we show experimental data from the National Drift Compression experiment-II group that verifies the result that underdense plasma can neutralize intense heavy ion beams effectively.
- 1 January 2015
- Published by AIP Publishing in Physics of Plasmas
- Vol. 22 (1) , 013104
Intense ion beam neutralization using underdense background plasma
Producing an overdense background plasma for neutralization purposes with a density that is high compared to the beam density is not always experimentally possible. We show that even an underdense background plasma with a small relative density can achieve high neutralization of intense ion beam pulses. Using particle-in-cell simulations, we show that if the total plasma electron charge is not sufficient to neutralize the beam charge, electron emitters are necessary for effective neutralization but are not needed if the plasma volume is so large that the total available charge in the electrons exceeds that of the ion beam. Several regimes of possible underdense/tenuous neutralization plasma densities are investigated with and without electron emitters or dense plasma at periphery regions, including the case of electron emitters without plasma, which does not effectively neutralize the beam. Over 95% neutralization is achieved for even very underdense background plasma with plasma density 1/15th the beam density. We compare results of particle-in-cell simulations with an analytic model of neutralization and find close agreement with the particle-in-cell simulations. Further, we show experimental data from the National Drift Compression experiment-II group that verifies the result that underdense plasma can neutralize intense heavy ion beams effectively.
- 1 January 2014
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 733, 226-232
The NDCX-II engineering design
- 1 January 2014
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 733, 226-232
The NDCX-II engineering design
- 1 January 2014
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1574 (1) , 178
Characterization of insulating coatings for wind-and-react coil fabrication
Electrical insulation breakdown between conductor and coil parts and structures is a limiting factor in the performance of high-field magnets. We have evaluated various insulation coatings for possible application in both and Bi-2212 coil fabrication. Such coatings must be robust to maintain structural integrity and provide adequate voltage standoff after the wind-and-react coil fabrication process. Such processes are characterized by reaction temperatures of 650°C in an inert atmosphere for and 890°C in a pure oxygen atmosphere for Bi-2212, and down to cryogenic temperatures when coils are in service. We present a method of testing standardized samples and report the performance characteristics of oxide layers produced (or applied) by plasma-spray, surface conversion, and “paintable” coatings in common areas of voltage breakdown in coil parts. We also address material compatibility and durability during high-temperature heat treatment and cryogenic shock. Suitable coatings selected in the testing process will be instrumental in improving the performance of future wind-and-react coils.- 1 January 2014
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1574 (1) , 178
Characterization of insulating coatings for wind-and-react coil fabrication
Electrical insulation breakdown between conductor and coil parts and structures is a limiting factor in the performance of high-field magnets. We have evaluated various insulation coatings for possible application in both and Bi-2212 coil fabrication. Such coatings must be robust to maintain structural integrity and provide adequate voltage standoff after the wind-and-react coil fabrication process. Such processes are characterized by reaction temperatures of 650°C in an inert atmosphere for and 890°C in a pure oxygen atmosphere for Bi-2212, and down to cryogenic temperatures when coils are in service. We present a method of testing standardized samples and report the performance characteristics of oxide layers produced (or applied) by plasma-spray, surface conversion, and “paintable” coatings in common areas of voltage breakdown in coil parts. We also address material compatibility and durability during high-temperature heat treatment and cryogenic shock. Suitable coatings selected in the testing process will be instrumental in improving the performance of future wind-and-react coils.- 1 January 2014
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 733, 112-118
Lithium ion sources
- 1 January 2014
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 733, 112-118
Lithium ion sources