J. Tyler Davidson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
J. Tyler Davidson has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
Alleigh N. Couch
Department of Forensic Science, Sam Houston State University, Huntsville, TX, USA
7 shared publicationsGlen P. Jackson
7 shared publications- Glen P. Jackson
West Virginia University
5 shared publications - Alleigh N. Couch
Department of Forensic Science
3 shared publications Christina Chang
Department of Forensic Science, Sam Houston State University, Huntsville, TX, USA
3 shared publicationsChristopher M. Zall
3 shared publications
Latest Publications
- Open Access
- 22 April 2026
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 37 (5) , 1281-1288
Addressing the Oxygen in the Room: Exploring the Formation of Oxygenated Species for Nitazene Analogs Using DART-MS
Direct analysis in real time-mass spectrometry (DART-MS) is a technique well suited for screening seized drug samples as it enables rapid analysis with minimal sample preparation. Therefore, information present in full scan mass spectra is extremely important and can indicate the presence of controlled substances in a sample. This study explores the formation of oxygenated species in the full scan mass spectra of 18 nitazene analogs, as well as a few other seized drug-related compounds. Generally, with helium as the source gas, an [M+H+O-2H]+ (i.e., +14 Da) ion was present, and with nitrogen as the source gas, an ion representing [M+H+O]+ (i.e., +16 Da) was observed. However, certain compounds, such as tetracaine, contained a +16 Da ion with helium as the source gas, indicating that both the source gas and chemical properties of the analyte impact oxygenated species formation. Further tandem mass spectrometry (MS/MS) studies were conducted to identify where the oxygen adduct was formed. The presence of a tertiary amine appears to play a role in oxygenation, as oxygenated iminium ions were frequently observed. Overall, oxygenated species were observed at higher abundances for the nitazene analogs than other controlled substances, providing an additional piece of support for a nitazene analog identification using DART-MS.
- 22 April 2026
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 37 (5) , 1281-1288
Open AccessAddressing the Oxygen in the Room: Exploring the Formation of Oxygenated Species for Nitazene Analogs Using DART-MS
Direct analysis in real time-mass spectrometry (DART-MS) is a technique well suited for screening seized drug samples as it enables rapid analysis with minimal sample preparation. Therefore, information present in full scan mass spectra is extremely important and can indicate the presence of controlled substances in a sample. This study explores the formation of oxygenated species in the full scan mass spectra of 18 nitazene analogs, as well as a few other seized drug-related compounds. Generally, with helium as the source gas, an [M+H+O-2H]+ (i.e., +14 Da) ion was present, and with nitrogen as the source gas, an ion representing [M+H+O]+ (i.e., +16 Da) was observed. However, certain compounds, such as tetracaine, contained a +16 Da ion with helium as the source gas, indicating that both the source gas and chemical properties of the analyte impact oxygenated species formation. Further tandem mass spectrometry (MS/MS) studies were conducted to identify where the oxygen adduct was formed. The presence of a tertiary amine appears to play a role in oxygenation, as oxygenated iminium ions were frequently observed. Overall, oxygenated species were observed at higher abundances for the nitazene analogs than other controlled substances, providing an additional piece of support for a nitazene analog identification using DART-MS.
- Open Access
- 27 March 2026
- Published by Elsevier in SSRN Electronic Journal
Characterization of copper-phosphine complexes for the differentiation of cannabinoid isomers using electrospray ionization-tandem mass spectrometry
The 2018 Agriculture Improvement Act provides the distinction between illicit marijuana and legal hemp based on a 0.3% ∆9-tetrahydrocannabinol (∆9-THC) threshold. Consequently, seized drug laboratories and regulatory agencies must implement analytical methods capable of qualitative identification and quantification of ∆9-THC. Analysis is further complicated by the complex matrix of Cannabis sativa L., which contains various cannabinoid isomers. While liquid chromatography-mass spectrometry (LC-MS) mitigates cannabinoid decarboxylation and cannabinoid conversion limitations inherent to gas chromatography-mass spectrometry (GC-MS), ∆9-THC isomers remain nearly indistinguishable in both full scan and product ion mass spectra. This study characterizes 11 Cu-phosphine complexes to assess their ability to differentiate common cannabinoids found in cannabis plant material, as well as ∆9-THC isomers that may be sprayed onto plant material, based on the formation of characteristic precursor or product ions. Specifically, the preferential binding affinity of cannabinoids to [Cu(PPh3)2(ACN)2]BF4, in combination with oxidative products generated through Cu-catalyzed O2 activation, facilitates the formation of a characteristic ion at nominal m/z 915 for ∆9-THC and no observable complex for CBD, enabling full scan isomer differentiation and eliminating potential CBD interference for ∆9-THC quantitation. Similar behavior was observed for [Cu((R)-BINAP)(ACN)2]BF4 and [Cu(dppf)(ACN)2]BF4. Methanolic extracts of authentic cannabis were analyzed using the optimal Cu-phosphine complexes to evaluate the applicability to real-world samples. By demonstrating the potential of Cu-phosphine ion complexation and introducing a novel approach to eliminate CBD interference, this study establishes the foundation for future research distinguishing illicit marijuana from legal hemp, potentially strengthening the capabilities of marijuana identification for seized drug laboratories.
- 27 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessCharacterization of copper-phosphine complexes for the differentiation of cannabinoid isomers using electrospray ionization-tandem mass spectrometry
The 2018 Agriculture Improvement Act provides the distinction between illicit marijuana and legal hemp based on a 0.3% ∆9-tetrahydrocannabinol (∆9-THC) threshold. Consequently, seized drug laboratories and regulatory agencies must implement analytical methods capable of qualitative identification and quantification of ∆9-THC. Analysis is further complicated by the complex matrix of Cannabis sativa L., which contains various cannabinoid isomers. While liquid chromatography-mass spectrometry (LC-MS) mitigates cannabinoid decarboxylation and cannabinoid conversion limitations inherent to gas chromatography-mass spectrometry (GC-MS), ∆9-THC isomers remain nearly indistinguishable in both full scan and product ion mass spectra. This study characterizes 11 Cu-phosphine complexes to assess their ability to differentiate common cannabinoids found in cannabis plant material, as well as ∆9-THC isomers that may be sprayed onto plant material, based on the formation of characteristic precursor or product ions. Specifically, the preferential binding affinity of cannabinoids to [Cu(PPh3)2(ACN)2]BF4, in combination with oxidative products generated through Cu-catalyzed O2 activation, facilitates the formation of a characteristic ion at nominal m/z 915 for ∆9-THC and no observable complex for CBD, enabling full scan isomer differentiation and eliminating potential CBD interference for ∆9-THC quantitation. Similar behavior was observed for [Cu((R)-BINAP)(ACN)2]BF4 and [Cu(dppf)(ACN)2]BF4. Methanolic extracts of authentic cannabis were analyzed using the optimal Cu-phosphine complexes to evaluate the applicability to real-world samples. By demonstrating the potential of Cu-phosphine ion complexation and introducing a novel approach to eliminate CBD interference, this study establishes the foundation for future research distinguishing illicit marijuana from legal hemp, potentially strengthening the capabilities of marijuana identification for seized drug laboratories.
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
Rapid identification of marijuana using copper–phosphine ion complexation and commercialized paper spray ionization-mass spectrometry
Novel application of Cu-phosphine ion complexation and commercialized paper spray ionization-mass spectrometry for the rapid identification of marijuana based on a semi-quantitative 1% decision-point assay.
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
Rapid identification of marijuana using copper–phosphine ion complexation and commercialized paper spray ionization-mass spectrometry
Novel application of Cu-phosphine ion complexation and commercialized paper spray ionization-mass spectrometry for the rapid identification of marijuana based on a semi-quantitative 1% decision-point assay.
- 17 December 2025
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 37 (1) , 346-351
Building In-House Libraries to Use with the NIST/NIJ DART-MS Data Interpretation Tool
This article presents two programs to help users construct mass spectral libraries for use with the NIST/NIJ DART-MS Data Interpretation Tool (version 3.22). The Full Database Builder program─which is a modification of the original database building script published through NIST─generates libraries that follow the exact specification of the NIST DART-MS Library builder. The Basic Database Builder program requires less information from the user and has fewer computational dependencies, making it an ideal program for users building small in-house libraries for research and testing purposes. The programs are available at https://github.com/asm3-trentu/CRAFTS-DBBuilder.
- 17 December 2025
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 37 (1) , 346-351
Building In-House Libraries to Use with the NIST/NIJ DART-MS Data Interpretation Tool
This article presents two programs to help users construct mass spectral libraries for use with the NIST/NIJ DART-MS Data Interpretation Tool (version 3.22). The Full Database Builder program─which is a modification of the original database building script published through NIST─generates libraries that follow the exact specification of the NIST DART-MS Library builder. The Basic Database Builder program requires less information from the user and has fewer computational dependencies, making it an ideal program for users building small in-house libraries for research and testing purposes. The programs are available at https://github.com/asm3-trentu/CRAFTS-DBBuilder.
- 8 December 2025
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 40 (5) , e70004
Comparison of Activation Techniques for the Identification of Nitazene Analogs Using the NIST/NIJ Data Interpretation Tool
Rationale: Direct analysis in real time (DART) and electrospray ionization (ESI) are commonly used in forensic science and are combined with different activation techniques, which impact the degree and type of fragmentation. Therefore, this study compares collision‐induced dissociation (CID), in‐source CID (IS‐CID), and all ions fragmentation (AIF) activation for nitazene analog identification using the NIST/NIJ Data Interpretation Tool (DIT). Methods: DART and ESI were used to analyze 18 nitazene analogs on a quadrupole time‐of‐flight (Q‐TOF) mass spectrometer. CID, IS‐CID, and AIF were explored with DART, and CID was used for ESI analysis. All activation techniques included the use of low, medium, and high activation energies. The resulting data were compared with the NIST DART‐MS Forensics Database using the NIST/NIJ DIT. Results: The CID spectra were generally less noisy and had fewer ions than the IS‐CID or the AIF spectra. The IS‐CID spectra generated higher mass‐to‐charge ( m/z ) product ions and had fewer characteristic product ions than either CID or AIF. The NIST/NIJ DIT correctly identified 14/18 nitazene analogs when using AIF compared with 13/18 correct identifications using both CID and IS‐CID. The ESI‐CID data produced 12/18 correctly identified samples. Conclusions: All three activation techniques performed similarly, based on the NIST/NIJ DIT results. However, IS‐CID produced significantly less fragmentation than CID or AIF, indicating that AIF is a suitable screening technique for this instrumental setup. The NIST/NIJ DIT can also be utilized for ESI‐CID spectra, although slightly fewer nitazene analogs were correctly identified with ESI‐CID than with DART‐CID.
- 8 December 2025
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 40 (5) , e70004
Comparison of Activation Techniques for the Identification of Nitazene Analogs Using the NIST/NIJ Data Interpretation Tool
Rationale: Direct analysis in real time (DART) and electrospray ionization (ESI) are commonly used in forensic science and are combined with different activation techniques, which impact the degree and type of fragmentation. Therefore, this study compares collision‐induced dissociation (CID), in‐source CID (IS‐CID), and all ions fragmentation (AIF) activation for nitazene analog identification using the NIST/NIJ Data Interpretation Tool (DIT). Methods: DART and ESI were used to analyze 18 nitazene analogs on a quadrupole time‐of‐flight (Q‐TOF) mass spectrometer. CID, IS‐CID, and AIF were explored with DART, and CID was used for ESI analysis. All activation techniques included the use of low, medium, and high activation energies. The resulting data were compared with the NIST DART‐MS Forensics Database using the NIST/NIJ DIT. Results: The CID spectra were generally less noisy and had fewer ions than the IS‐CID or the AIF spectra. The IS‐CID spectra generated higher mass‐to‐charge ( m/z ) product ions and had fewer characteristic product ions than either CID or AIF. The NIST/NIJ DIT correctly identified 14/18 nitazene analogs when using AIF compared with 13/18 correct identifications using both CID and IS‐CID. The ESI‐CID data produced 12/18 correctly identified samples. Conclusions: All three activation techniques performed similarly, based on the NIST/NIJ DIT results. However, IS‐CID produced significantly less fragmentation than CID or AIF, indicating that AIF is a suitable screening technique for this instrumental setup. The NIST/NIJ DIT can also be utilized for ESI‐CID spectra, although slightly fewer nitazene analogs were correctly identified with ESI‐CID than with DART‐CID.
- 28 November 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1384, 344953
Differentiation of CBD and Δ9-THC isomers using copper-ion complexation and electrospray ionization-tandem mass spectrometry
- 28 November 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1384, 344953
Differentiation of CBD and Δ9-THC isomers using copper-ion complexation and electrospray ionization-tandem mass spectrometry
- 4 July 2025
- Published by Wiley in Drug Testing and Analysis
- Vol. 17 (11) , 2127-2140
Structural Characterization of Nitazene Analogs Using Electrospray Ionization–Tandem Mass Spectrometry (ESI–MS/MS)
Nitazene analogs are potent novel synthetic opioids (NSOs) that are becoming increasingly common and pose a threat to the public because of their fentanyl‐like effects. Although 12 nitazene analogs are currently classified as Schedule I under the U.S. Controlled Substances Act, novel analogs continue to emerge, making their identification in forensic laboratories exceedingly difficult. Liquid chromatography–electrospray ionization–tandem mass spectrometry (LC–ESI–MS/MS) is commonly utilized in toxicology laboratories and is becoming more common for seized drug analysis, particularly for compounds less suited for gas chromatography–electron ionization–mass spectrometry (GC–EI–MS). This study provides a comprehensive structural characterization of 38 representative nitazene analogs using LC–ESI–MS/MS instrumentation, including the proposed fragmentation mechanisms that lead to the formation of diagnostic product ions, enabling analog differentiation. General fragmentation pathways and mechanisms are proposed for all nitazene analogs, including inductive cleavages and molecular rearrangements. Overall, the most common product ions for nitazene analogs are derived from the substitutions to the amine or benzyl moieties, such as m/z 100, m/z 72, m/z 44, and m/z 107. However, the presence of different substitutions shifts the observed product ions. For example, recently occurring piperidine or pyrrolidine rings produce diagnostic product ions at m/z 112 and m/z 98, respectively. Therefore, modification to the core nitazene structure produces different diagnostic product ions, which can be used to identify existing and novel analogs. This study provides a comprehensive assessment of the fragmentation behavior of nitazene analogs under ESI–MS/MS conditions, which provides the basis for identifying new structural modifications in novel nitazene analogs.
- 4 July 2025
- Published by Wiley in Drug Testing and Analysis
- Vol. 17 (11) , 2127-2140
Structural Characterization of Nitazene Analogs Using Electrospray Ionization–Tandem Mass Spectrometry (ESI–MS/MS)
Nitazene analogs are potent novel synthetic opioids (NSOs) that are becoming increasingly common and pose a threat to the public because of their fentanyl‐like effects. Although 12 nitazene analogs are currently classified as Schedule I under the U.S. Controlled Substances Act, novel analogs continue to emerge, making their identification in forensic laboratories exceedingly difficult. Liquid chromatography–electrospray ionization–tandem mass spectrometry (LC–ESI–MS/MS) is commonly utilized in toxicology laboratories and is becoming more common for seized drug analysis, particularly for compounds less suited for gas chromatography–electron ionization–mass spectrometry (GC–EI–MS). This study provides a comprehensive structural characterization of 38 representative nitazene analogs using LC–ESI–MS/MS instrumentation, including the proposed fragmentation mechanisms that lead to the formation of diagnostic product ions, enabling analog differentiation. General fragmentation pathways and mechanisms are proposed for all nitazene analogs, including inductive cleavages and molecular rearrangements. Overall, the most common product ions for nitazene analogs are derived from the substitutions to the amine or benzyl moieties, such as m/z 100, m/z 72, m/z 44, and m/z 107. However, the presence of different substitutions shifts the observed product ions. For example, recently occurring piperidine or pyrrolidine rings produce diagnostic product ions at m/z 112 and m/z 98, respectively. Therefore, modification to the core nitazene structure produces different diagnostic product ions, which can be used to identify existing and novel analogs. This study provides a comprehensive assessment of the fragmentation behavior of nitazene analogs under ESI–MS/MS conditions, which provides the basis for identifying new structural modifications in novel nitazene analogs.
- 24 May 2025
- Published by Elsevier in Forensic Science International
- Vol. 372, 112512
Assessment of a combined handheld Raman spectroscopy and transportable mass spectrometry approach for the analysis of seized drug mixtures
- 24 May 2025
- Published by Elsevier in Forensic Science International
- Vol. 372, 112512
Assessment of a combined handheld Raman spectroscopy and transportable mass spectrometry approach for the analysis of seized drug mixtures
- 19 May 2025
- Published by Wiley in Journal of Forensic Sciences
- Vol. 70 (5) , 1949-1962
Development and validation of a combined selected ion monitoring‐scan GC ‐ EI ‐ MS method for nitazene analogs
Novel synthetic opioids (NSOs) emerged during the third wave of the opioid epidemic, which has resulted in countless overdose deaths. Although fentanyl and fentanyl analogs are the most common NSOs, changing legislation in China and the United States led to the emergence of another class of NSOs, known as nitazene analogs. Nitazene analogs are very potent, and given their increasing prevalence in seized drug casework, it is imperative that seized drug laboratories have sufficient methods to identify nitazene analogs. This study developed a combined selected ion monitoring (SIM)‐scan method to identify 20 nitazene analogs using gas chromatography‐electron ionization‐mass spectrometry (GC‐EI‐MS). The method was evaluated in terms of the limit of detection (LOD), carryover, selectivity, repeatability, reproducibility, and processed sample stability. The LOD for the targeted nitazene analogs ranged from 5 to 10 ppm due to increased sensitivity through SIM acquisition. No carryover was observed, and all nitazene analogs could be differentiated from other analogs and common interferences. The repeatability and reproducibility of the method were demonstrated qualitatively. All nitazene analogs were stable at room temperature for at least 24 hours. When applied to the analysis of blind simulant samples, 33 out of 35 samples were correctly identified, with the two misidentifications being due to ion ratios outside of tolerance. Likewise, two authentic nitazene analog casework samples were also correctly identified. The validated SIM‐scan method provides a potential solution to identify low concentration nitazene analogs in seized drug casework that might otherwise be missed using routine GC–MS full scan acquisition.
- 19 May 2025
- Published by Wiley in Journal of Forensic Sciences
- Vol. 70 (5) , 1949-1962
Development and validation of a combined selected ion monitoring‐scan GC ‐ EI ‐ MS method for nitazene analogs
Novel synthetic opioids (NSOs) emerged during the third wave of the opioid epidemic, which has resulted in countless overdose deaths. Although fentanyl and fentanyl analogs are the most common NSOs, changing legislation in China and the United States led to the emergence of another class of NSOs, known as nitazene analogs. Nitazene analogs are very potent, and given their increasing prevalence in seized drug casework, it is imperative that seized drug laboratories have sufficient methods to identify nitazene analogs. This study developed a combined selected ion monitoring (SIM)‐scan method to identify 20 nitazene analogs using gas chromatography‐electron ionization‐mass spectrometry (GC‐EI‐MS). The method was evaluated in terms of the limit of detection (LOD), carryover, selectivity, repeatability, reproducibility, and processed sample stability. The LOD for the targeted nitazene analogs ranged from 5 to 10 ppm due to increased sensitivity through SIM acquisition. No carryover was observed, and all nitazene analogs could be differentiated from other analogs and common interferences. The repeatability and reproducibility of the method were demonstrated qualitatively. All nitazene analogs were stable at room temperature for at least 24 hours. When applied to the analysis of blind simulant samples, 33 out of 35 samples were correctly identified, with the two misidentifications being due to ion ratios outside of tolerance. Likewise, two authentic nitazene analog casework samples were also correctly identified. The validated SIM‐scan method provides a potential solution to identify low concentration nitazene analogs in seized drug casework that might otherwise be missed using routine GC–MS full scan acquisition.
- 25 January 2025
- Published by Elsevier in Forensic Science International
- Vol. 367, 112381
Technical note: Evaluation of a transportable linear ion trap mass spectrometer for seized drug screening operated under controlled laboratory conditions
- 25 January 2025
- Published by Elsevier in Forensic Science International
- Vol. 367, 112381
Technical note: Evaluation of a transportable linear ion trap mass spectrometer for seized drug screening operated under controlled laboratory conditions