Pingjing Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pingjing Li has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Sam Fong Yau Li
Department of Chemistry, National University of Singapore, 3 Science Drive 3, Singapore 117543, Singapore
7 shared publications Bin Hu
3 shared publications- Bin Hu
Wuhan University
3 shared publications Huatao Feng
Natl Univ Singapore, Dept Chem, 3 Sci Dr 3 S117543, Singapore, Singapore
3 shared publicationsAnna Karen Carrasco Laserna
Natl Univ Singapore, Dept Chem, 3 Sci Dr 3 S117543, Singapore, Singapore
2 shared publicationsBeibei Chen
Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), Department of Chemistry, Wuhan University, Wuhan 430072, China
2 shared publications
Latest Publications
- 19 September 2025
- Published by Elsevier in Environmental Research
- Vol. 286 (Pt 2) , 122905
Tissue-specific microplastic burden in cetacean non-digestive organs
- 19 September 2025
- Published by Elsevier in Environmental Research
- Vol. 286 (Pt 2) , 122905
Tissue-specific microplastic burden in cetacean non-digestive organs
- 25 April 2025
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 493, 138413
Trace elements concentration, tissue distribution, and associated health risks in wild and captive pantropical spotted dolphins (Stenella attenuata)
- 25 April 2025
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 493, 138413
Trace elements concentration, tissue distribution, and associated health risks in wild and captive pantropical spotted dolphins (Stenella attenuata)
- 1 December 2023
- Published by Elsevier in Environmental Pollution
- Vol. 342, 123072
The occurrence of pollutants in organisms and water of inland mariculture systems: Shrimp aquaculture is a procession of Microplastics accumulation
- 1 December 2023
- Published by Elsevier in Environmental Pollution
- Vol. 342, 123072
The occurrence of pollutants in organisms and water of inland mariculture systems: Shrimp aquaculture is a procession of Microplastics accumulation
- 5 March 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10891, 108910B
Carbon dots-based fluorescent sensor for nanoscale sensing
Chromium is a toxic metal can do severe damage to public health, plants, and aquatic animals due to its high carcinogenicity. Cr(VI) is about 1000 times more toxic than Cr(III). As a result, exploring methods for differentiation between Cr(III) and Cr(VI) and quantification of these species with high selectivity are essential in aquatic analysis. In this paper, carbon-dots (C-dots) were successfully synthesized with high quantum yield and applied for the determination of the concentration of Cr(VI). It was found that C-dots and Cr (VI) were effective fluorophore and quencher pair for the fluorescence sensor based on inner filter effect. The fluorescence intensity of the C-dots was highly sensitive to the change of concentration of Cr (VI) with good analytical performance. Since ascorbic acid (AA) has been advocated as a treatment of systemic chromium poisoning by converting Cr(VI) to Cr(III), the determination of AA was also investigated. A standard addition methodology was used to determine the Cr(VI) concentration in water samples and the concentration of AA in human serum samples with good results. In summary, compared to traditional methods, the method using C–dots as fluorescence probe is sensitive, selective, cheap and eco-friendly for the determination of the concentration of Cr(VI) and ascorbic acid.
- 5 March 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10891, 108910B
Carbon dots-based fluorescent sensor for nanoscale sensing
Chromium is a toxic metal can do severe damage to public health, plants, and aquatic animals due to its high carcinogenicity. Cr(VI) is about 1000 times more toxic than Cr(III). As a result, exploring methods for differentiation between Cr(III) and Cr(VI) and quantification of these species with high selectivity are essential in aquatic analysis. In this paper, carbon-dots (C-dots) were successfully synthesized with high quantum yield and applied for the determination of the concentration of Cr(VI). It was found that C-dots and Cr (VI) were effective fluorophore and quencher pair for the fluorescence sensor based on inner filter effect. The fluorescence intensity of the C-dots was highly sensitive to the change of concentration of Cr (VI) with good analytical performance. Since ascorbic acid (AA) has been advocated as a treatment of systemic chromium poisoning by converting Cr(VI) to Cr(III), the determination of AA was also investigated. A standard addition methodology was used to determine the Cr(VI) concentration in water samples and the concentration of AA in human serum samples with good results. In summary, compared to traditional methods, the method using C–dots as fluorescence probe is sensitive, selective, cheap and eco-friendly for the determination of the concentration of Cr(VI) and ascorbic acid.
- Open Access
- 1 January 2018
- Published by Taylor & Francis in Cogent Chemistry
- Vol. 4 (1)
Intact NIST monoclonal antibody characterization—Proteoforms, glycoforms—Using CE-MS and CE-LIF
Determining and linking the structural heterogeneity of recombinant antibodies to function is critical in the biopharmaceutical industry. We introduce a new microfluidic capillary electrophoresis—mass spectrometry (μCE-MS) approach to characterize intact monoclonal antibody (mAb) and simultaneously quantifying distinct variants. Our MS analysis of intact NIST mAb (RM8671) shows 18 variants identified amongst proteolytic and glycolytic modifications with a range of relative abundances between 0.1% and 100%. In order to verify our quantitative MS results, we used an established system based on capillary electrophoresis—with laser induced fluorescence (CE-LIF) for profiling the N-glycans. All major glycans were identified and further substantiated by exoglycosidase digestion. Interestingly, the µCE-MS analysis of intact NIST mAb consistently yielded higher amounts of G2FG2F-Hex glycoform (~3.4%), whereas the CE-LIF analysis indicates that only 1.4% of G2F-Gal is present. Therefore, the additional hexose adduct observed in µCE-MS may have been the glycation product of the mAb. Further analysis of deglycosylated mAb with µCE-MS made it possible to reveal the glycation with 10.5% of one hexose product and 4.9% of two hexose product in the intact deglycosylated antibody. An integrated solution using two orthogonal and complementary techniques for characterizing antibody glycosylation is provided here.
- 1 January 2018
- Published by Taylor & Francis in Cogent Chemistry
- Vol. 4 (1)
Open AccessIntact NIST monoclonal antibody characterization—Proteoforms, glycoforms—Using CE-MS and CE-LIF
Determining and linking the structural heterogeneity of recombinant antibodies to function is critical in the biopharmaceutical industry. We introduce a new microfluidic capillary electrophoresis—mass spectrometry (μCE-MS) approach to characterize intact monoclonal antibody (mAb) and simultaneously quantifying distinct variants. Our MS analysis of intact NIST mAb (RM8671) shows 18 variants identified amongst proteolytic and glycolytic modifications with a range of relative abundances between 0.1% and 100%. In order to verify our quantitative MS results, we used an established system based on capillary electrophoresis—with laser induced fluorescence (CE-LIF) for profiling the N-glycans. All major glycans were identified and further substantiated by exoglycosidase digestion. Interestingly, the µCE-MS analysis of intact NIST mAb consistently yielded higher amounts of G2FG2F-Hex glycoform (~3.4%), whereas the CE-LIF analysis indicates that only 1.4% of G2F-Gal is present. Therefore, the additional hexose adduct observed in µCE-MS may have been the glycation product of the mAb. Further analysis of deglycosylated mAb with µCE-MS made it possible to reveal the glycation with 10.5% of one hexose product and 4.9% of two hexose product in the intact deglycosylated antibody. An integrated solution using two orthogonal and complementary techniques for characterizing antibody glycosylation is provided here.
- 1 December 2017
- Published by Elsevier in Analytica Chimica Acta
- Vol. 995, 106-113
High throughput human plasma N-glycan analysis using DNA analyzer and multivariate analysis for biomarker discovery
- 1 December 2017
- Published by Elsevier in Analytica Chimica Acta
- Vol. 995, 106-113
High throughput human plasma N-glycan analysis using DNA analyzer and multivariate analysis for biomarker discovery
- 3 July 2017
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 5 (28) , 6962-6972
Rapid detection of an anthrax biomarker based on the recovered fluorescence of carbon dot–Cu(ii) systems
The sensitive detection of dipicolinic acid (DPA) is strongly associated with the sensing of bacterial organisms in environmental and biological samples. In this work, we developed a novel and sensitive label-free sensor for the detection of dipicolinic acid (DPA), a biomarker of the biological threat-agent anthrax, using an “off–on” fluorescent carbon dot (CD)–Cu(II) system. Fluorescent CDs with a quantum yield of 24.7% were prepared by a simple one-pot hydrothermal treatment of dopamine in acidic conditions (pH 5.0) under nitrogen gas. As the prepared CDs have two fluorescent centers at a single-wavelength excitation of 315 nm at low concentration, a novel ratiometric fluorescent sensor for the determination of DPA was designed to facilitate self-calibration by using one center as the internal reference and another center as the signal reporter. The fluorescence of the CDs was found to be effectively quenched by Cu(II), and subsequently restored with high sensitivity in the presence of DPA via an “off–on” fluorescence response due to the strong chelate-conjugation between Cu(II) and DPA. Under optimal conditions, good linearity for DPA detection was obtained over the concentration range from 0.25 to 20 μmoL L−1, with a detection limit of 0.079 μmoL L−1. The proposed simple, fast and convenient method was applied for DPA detection in different types of environmental water samples and fetal bovine serum samples, and the results are in agreement with the results of standard additions in an acceptable recovery range.
- 3 July 2017
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 5 (28) , 6962-6972
Rapid detection of an anthrax biomarker based on the recovered fluorescence of carbon dot–Cu(ii) systems
The sensitive detection of dipicolinic acid (DPA) is strongly associated with the sensing of bacterial organisms in environmental and biological samples. In this work, we developed a novel and sensitive label-free sensor for the detection of dipicolinic acid (DPA), a biomarker of the biological threat-agent anthrax, using an “off–on” fluorescent carbon dot (CD)–Cu(II) system. Fluorescent CDs with a quantum yield of 24.7% were prepared by a simple one-pot hydrothermal treatment of dopamine in acidic conditions (pH 5.0) under nitrogen gas. As the prepared CDs have two fluorescent centers at a single-wavelength excitation of 315 nm at low concentration, a novel ratiometric fluorescent sensor for the determination of DPA was designed to facilitate self-calibration by using one center as the internal reference and another center as the signal reporter. The fluorescence of the CDs was found to be effectively quenched by Cu(II), and subsequently restored with high sensitivity in the presence of DPA via an “off–on” fluorescence response due to the strong chelate-conjugation between Cu(II) and DPA. Under optimal conditions, good linearity for DPA detection was obtained over the concentration range from 0.25 to 20 μmoL L−1, with a detection limit of 0.079 μmoL L−1. The proposed simple, fast and convenient method was applied for DPA detection in different types of environmental water samples and fetal bovine serum samples, and the results are in agreement with the results of standard additions in an acceptable recovery range.
- 11 May 2017
- Published by Wiley in Electrophoresis
- Vol. 38 (13-14) , 1788-1799
Multiplexing N‐glycan analysis by DNA analyzer
Analysis of N‐glycan structures has been gaining attentions over the years due to their critical importance to biopharma‐based applications and growing roles in biological research. Glycan profiling is also critical to the development of biosimilar drugs. The detailed characterization of N‐glycosylation is mandatory because it is a nontemplate driven process and that significantly influences critical properties such as bio‐safety and bio‐activity. The ability to comprehensively characterize highly complex mixtures of N‐glycans has been analytically challenging and stimulating because of the difficulties in both the structure complexity and time‐consuming sample pretreatment procedures. CE‐LIF is one of the typical techniques for N‐glycan analysis due to its high separation efficiency. In this paper, a 16‐capillary DNA analyzer was coupled with a magnetic bead glycan purification method to accelerate the sample preparation procedure and therefore increase N‐glycan assay throughput. Routinely, the labeling dye used for CE‐LIF is 8‐aminopyrene‐1,3,6‐trisulfonic acid, while the typical identification method involves matching migration times with database entries. Two new fluorescent dyes were used to either cross‐validate and increase the glycan identification precision or simplify sample preparation steps. Exoglycosidase studies were carried out using neuramididase, galactosidase, and fucosidase to confirm the results of three dye cross‐validation. The optimized method combines the parallel separation capacity of multiple‐capillary separation with three labeling dyes, magnetic bead assisted preparation, and exoglycosidase treatment to allow rapid and accurate analysis of N‐glycans. These new methods provided enough useful structural information to permit N‐glycan structure elucidation with only one sample injection.
- 11 May 2017
- Published by Wiley in Electrophoresis
- Vol. 38 (13-14) , 1788-1799
Multiplexing N‐glycan analysis by DNA analyzer
Analysis of N‐glycan structures has been gaining attentions over the years due to their critical importance to biopharma‐based applications and growing roles in biological research. Glycan profiling is also critical to the development of biosimilar drugs. The detailed characterization of N‐glycosylation is mandatory because it is a nontemplate driven process and that significantly influences critical properties such as bio‐safety and bio‐activity. The ability to comprehensively characterize highly complex mixtures of N‐glycans has been analytically challenging and stimulating because of the difficulties in both the structure complexity and time‐consuming sample pretreatment procedures. CE‐LIF is one of the typical techniques for N‐glycan analysis due to its high separation efficiency. In this paper, a 16‐capillary DNA analyzer was coupled with a magnetic bead glycan purification method to accelerate the sample preparation procedure and therefore increase N‐glycan assay throughput. Routinely, the labeling dye used for CE‐LIF is 8‐aminopyrene‐1,3,6‐trisulfonic acid, while the typical identification method involves matching migration times with database entries. Two new fluorescent dyes were used to either cross‐validate and increase the glycan identification precision or simplify sample preparation steps. Exoglycosidase studies were carried out using neuramididase, galactosidase, and fucosidase to confirm the results of three dye cross‐validation. The optimized method combines the parallel separation capacity of multiple‐capillary separation with three labeling dyes, magnetic bead assisted preparation, and exoglycosidase treatment to allow rapid and accurate analysis of N‐glycans. These new methods provided enough useful structural information to permit N‐glycan structure elucidation with only one sample injection.
- 5 April 2017
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 5 (16) , 2979-2988
An efficient “off–on” carbon nanoparticle-based fluorescent sensor for recognition of chromium( vi ) and ascorbic acid based on the inner filter effect
A simple approach based on calcination treatment of diethylenetriaminepentaacetic acid (DTPA) was developed to prepare water-soluble nitrogen doped carbon nanoparticles (N-CNPs) with a high quantum yield of approximately 53.7%. The fluorescence of N-CNPs could be quickly and efficiently quenched by Cr(VI) rather than Cr(III) based on an inner filter effect (IFE) process. The addition of ascorbic acid (AA) can recover the intensity of fluorescence of the N-CNP–Cr(VI) system through the reduction of Cr(VI) to Cr(III) and inhibit the IFE process between N-CNPs and Cr(VI) (turn-on). Accordingly, an efficient N-CNP based fluorescent probe for sensitive and selective sensing of Cr(VI) ions and L-ascorbic acid (AA) has been established. The proposed fluorescence sensor displays excellent performance for Cr(VI) determination in the range from 0.5 to 160 μmol L−1 (R2 = 0.998) with a detection limit down to 0.15 μmol L−1. Moreover, the observed linear response concentration range was from 1 to 400 μmol L−1 for AA with a detection limit as low as 0.13 μmol L−1. The fluorescent probe was successfully applied to detect Cr(VI) concentration in different water samples and AA concentration in human serum samples.
- 5 April 2017
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 5 (16) , 2979-2988
An efficient “off–on” carbon nanoparticle-based fluorescent sensor for recognition of chromium( vi ) and ascorbic acid based on the inner filter effect
A simple approach based on calcination treatment of diethylenetriaminepentaacetic acid (DTPA) was developed to prepare water-soluble nitrogen doped carbon nanoparticles (N-CNPs) with a high quantum yield of approximately 53.7%. The fluorescence of N-CNPs could be quickly and efficiently quenched by Cr(VI) rather than Cr(III) based on an inner filter effect (IFE) process. The addition of ascorbic acid (AA) can recover the intensity of fluorescence of the N-CNP–Cr(VI) system through the reduction of Cr(VI) to Cr(III) and inhibit the IFE process between N-CNPs and Cr(VI) (turn-on). Accordingly, an efficient N-CNP based fluorescent probe for sensitive and selective sensing of Cr(VI) ions and L-ascorbic acid (AA) has been established. The proposed fluorescence sensor displays excellent performance for Cr(VI) determination in the range from 0.5 to 160 μmol L−1 (R2 = 0.998) with a detection limit down to 0.15 μmol L−1. Moreover, the observed linear response concentration range was from 1 to 400 μmol L−1 for AA with a detection limit as low as 0.13 μmol L−1. The fluorescent probe was successfully applied to detect Cr(VI) concentration in different water samples and AA concentration in human serum samples.