Gerald Kada
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Gerald Kada has a total of 138 co-authors. Here are the top co-authors by number of shared publications:
Ferry Kienberger
9 shared publicationsPeter Hinterdorfer
9 shared publications- Christian Rankl
Research Center for Non Destructive Testing GmbH (RECENDT)
7 shared publications Hermann J. Gruber
University of Linz
6 shared publications- Andreas Ebner
Institute of Biophysics, Johannes Kepler University Linz, Linz, Austria
5 shared publications - Lilia A. Chtcheglova
Institute of Biophysics, Johannes Kepler University (JKU) Linz, Gruberstrasse 40, 4020 Linz, Austria
5 shared publications
Latest Publications
- 1 March 2016
- Published by Oxford University Press (OUP) in Microscopy Today
- Vol. 24 (6) , 26-31
New Atomic Force Microscope Facilitates Faster Workflow for Nanoscale In Situ Applications
- 1 March 2016
- Published by Oxford University Press (OUP) in Microscopy Today
- Vol. 24 (6) , 26-31
New Atomic Force Microscope Facilitates Faster Workflow for Nanoscale In Situ Applications
- 1 March 2013
- Published by Elsevier in Optics Communications
- Vol. 291, 259-263
2 nm Quantum Optical Lithography
- 1 March 2013
- Published by Elsevier in Optics Communications
- Vol. 291, 259-263
2 nm Quantum Optical Lithography
- 1 May 2010
- Published by Elsevier in Ultramicroscopy
- Vol. 110 (6) , 605-611
Molecular recognition imaging using tuning fork-based transverse dynamic force microscopy
- 1 May 2010
- Published by Elsevier in Ultramicroscopy
- Vol. 110 (6) , 605-611
Molecular recognition imaging using tuning fork-based transverse dynamic force microscopy
- 22 February 2010
- Published by IOP Publishing in Nanotechnology
- Vol. 21 (11) , 115504
Improved localization of cellular membrane receptors using combined fluorescence microscopy and simultaneous topography and recognition imaging
The combination of fluorescence microscopy and atomic force microscopy has a great potential in single-molecule-detection applications, overcoming many of the limitations coming from each individual technique. Here we present a new platform of combined fluorescence and simultaneous topography and recognition imaging (TREC) for improved localization of cellular receptors. Green fluorescent protein (GFP) labeled human sodium-glucose cotransporter (hSGLT1) expressed Chinese Hamster Ovary (CHO) cells and endothelial cells (MyEnd) from mouse myocardium stained with phalloidin-rhodamine were used as cell systems to study AFM topography and fluorescence microscopy on the same surface area. Topographical AFM images revealed membrane features such as lamellipodia, cytoskeleton fibers, F-actin filaments and small globular structures with heights ranging from 20 to 30 nm. Combined fluorescence and TREC imaging was applied to detect density, distribution and localization of YFP-labeled CD1d molecules on alpha-galactosylceramide (alphaGalCer)-loaded THP1 cells. While the expression level, distribution and localization of CD1d molecules on THP1 cells were detected with fluorescence microscopy, the nanoscale distribution of binding sites was investigated with molecular recognition imaging by using a chemically modified AFM tip. Using TREC on the inverted light microscope, the recognition sites of cell receptors were detected in recognition images with domain sizes ranging from approximately 25 to approximately 160 nm, with the smaller domains corresponding to a single CD1d molecule.
- 22 February 2010
- Published by IOP Publishing in Nanotechnology
- Vol. 21 (11) , 115504
Improved localization of cellular membrane receptors using combined fluorescence microscopy and simultaneous topography and recognition imaging
The combination of fluorescence microscopy and atomic force microscopy has a great potential in single-molecule-detection applications, overcoming many of the limitations coming from each individual technique. Here we present a new platform of combined fluorescence and simultaneous topography and recognition imaging (TREC) for improved localization of cellular receptors. Green fluorescent protein (GFP) labeled human sodium-glucose cotransporter (hSGLT1) expressed Chinese Hamster Ovary (CHO) cells and endothelial cells (MyEnd) from mouse myocardium stained with phalloidin-rhodamine were used as cell systems to study AFM topography and fluorescence microscopy on the same surface area. Topographical AFM images revealed membrane features such as lamellipodia, cytoskeleton fibers, F-actin filaments and small globular structures with heights ranging from 20 to 30 nm. Combined fluorescence and TREC imaging was applied to detect density, distribution and localization of YFP-labeled CD1d molecules on alpha-galactosylceramide (alphaGalCer)-loaded THP1 cells. While the expression level, distribution and localization of CD1d molecules on THP1 cells were detected with fluorescence microscopy, the nanoscale distribution of binding sites was investigated with molecular recognition imaging by using a chemically modified AFM tip. Using TREC on the inverted light microscope, the recognition sites of cell receptors were detected in recognition images with domain sizes ranging from approximately 25 to approximately 160 nm, with the smaller domains corresponding to a single CD1d molecule.
- 1 July 2009
- Published by Elsevier in Ultramicroscopy
- Vol. 109 (8) , 1056-1060
Second harmonic atomic force microscopy imaging of live and fixed mammalian cells
- 1 July 2009
- Published by Elsevier in Ultramicroscopy
- Vol. 109 (8) , 1056-1060
Second harmonic atomic force microscopy imaging of live and fixed mammalian cells
An AFM/Rotaxane Molecular Reading Head for Sequence‐Dependent DNA Structures
DNA secondary structure may prove to be a significant obstacle both for enzymes that process DNA through an orifice and for the passage of DNA through nanopores proposed for some novel sequencing schemes. A nanomechanical molecular “tape reader” is assembled by threading a nanopore over DNA and pulling it using an atomic force microscope. Its formation is confirmed by studying the force required to open hairpins under that geometry. Unfolding induced by this 0.7‐nm‐diameter aperture requires 40 times more force than that reported for pulling on the ends of the DNA. Kinetic analysis shows that much less strain is required to destabilize the double helix in this geometry. Consequently, much more force is required to provide the free energy needed for opening.
An AFM/Rotaxane Molecular Reading Head for Sequence‐Dependent DNA Structures
DNA secondary structure may prove to be a significant obstacle both for enzymes that process DNA through an orifice and for the passage of DNA through nanopores proposed for some novel sequencing schemes. A nanomechanical molecular “tape reader” is assembled by threading a nanopore over DNA and pulling it using an atomic force microscope. Its formation is confirmed by studying the force required to open hairpins under that geometry. Unfolding induced by this 0.7‐nm‐diameter aperture requires 40 times more force than that reported for pulling on the ends of the DNA. Kinetic analysis shows that much less strain is required to destabilize the double helix in this geometry. Consequently, much more force is required to provide the free energy needed for opening.
- 1 February 2008
- Published by Elsevier in Nano Today
- Vol. 3 (1-2) , 12-19
Atomic force microscopy in bionanotechnology
- 1 February 2008
- Published by Elsevier in Nano Today
- Vol. 3 (1-2) , 12-19
Atomic force microscopy in bionanotechnology
- 1 January 2008
- Published by Springer Nature
- Vol. 418, 73-88
Application of biotin-4-fluorescein in homogeneous fluorescence assays for avidin, streptavidin, and biotin or biotin derivatives.
- 1 January 2008
- Published by Springer Nature
- Vol. 418, 73-88
Application of biotin-4-fluorescein in homogeneous fluorescence assays for avidin, streptavidin, and biotin or biotin derivatives.
- 1 July 2007
- Published by Elsevier in Forensic Science International
- Vol. 170 (1) , 8-14
Age determination of blood spots in forensic medicine by force spectroscopy
- 1 July 2007
- Published by Elsevier in Forensic Science International
- Vol. 170 (1) , 8-14
Age determination of blood spots in forensic medicine by force spectroscopy
- 1 May 2007
- Published by Elsevier in Biomaterials
- Vol. 28 (15) , 2403-2411
Dynamic force microscopy imaging of plasmid DNA and viral RNA
- 1 May 2007
- Published by Elsevier in Biomaterials
- Vol. 28 (15) , 2403-2411
Dynamic force microscopy imaging of plasmid DNA and viral RNA