NSNur Asmiza Selamat

Nur Asmiza Selamat

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nur Asmiza Selamat has a total of 44 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    PID controller tuning performance evaluation based on integral time square error for coupled tank system

    by Nur Asmiza Selamat, Atikah Razi, Syahar Azalia Ab Shukor, Nur Hazahsha Shamsudin, Fardila M. Zaihideee

    This study presents a conclusive performance evaluation based on integral time between the conventional and optimization based proportional integral derivatives (PID) tuning method. The tuning method of interest are including trial and error, auto-tuning, Ziegler-Nichols (ZN), Cohen-Coon (CC), and particle swarm optimization (PSO). The coupled tank system (CTS) is used for the system under consideration as it’s one of the popular technologies in industrial control application. Previous study had compared the tuning performance in terms of its transient response. The transient consists of several parameters such as rise time (Tr), settling time (Ts), peak time (Tp), steady state error, overshoot, and steady state error. Due to that, a conclusive performance comparison could not be achieved. Hence this study proposed integral time squared error evolution which is based on only one parameter which also reflects good overall transient response performance. The results show that of all tuning methods, PSO provide the smallest integral time square error (ITSE) value, while trial and error provide the highest with a value of 12.84 and 203.10, respectively. The ITSE also reflects the transient response performances.

  • Open Access

    The evolution of smart sprayer system for agricultural sector in Malaysia

    by Nur Hazahsha Shamsudin, Norman Koliah Anak Noheng, Siti Amaniah Mohd Chachuli, Nur Asmiza Selamat, Hrithik Tawai, Nurliyana Abdul Raof

    This study presents the development of a smart sprayer system featuring a microcontroller, ultrasonic sensors, and a Wi-Fi module for agriculture. This system enables 360° movement capabilities and facilitates the activation and deactivation of the sprayer pump remotely. The system offers remote control functionality through smartphone integration, effectively mitigating the need for direct physical contact with hazardous chemicals during the spraying operation. The results demonstrate the efficient operation of the smart sprayer system. The average spraying efficacy is estimated to be 95%, surpassing that of conventional spraying methods, as evidenced by prior research studies. The system is accessible for remote operation via a user-friendly interface, facilitated by the integrated internet of things (IoT) and microcontroller. As anticipated, it successfully executed 360° movements, obstacle detection, water level indication, and remote control of the sprayer pump.


  • Novel Chewing Cycle Approach for Peak Detection Algorithm of Chew Count Estimation

    by Nur Asmiza Selamat, Sawal Hamid Md Ali, Ahmad Ghadafi Ismail, Siti Anom Ahmad, Khairun Nisa’ Minhad

    Chew count is a critical parameter in analyzing mastication signals, yet traditional methods of manual counting by trained clinicians are often labor-intensive and prone to errors. As a result, there has been a growing interest among researchers in developing automated methods for estimating chew count. This paper reviews existing approaches, evaluates their effectiveness, and proposes a new approach based on optimization technique. This work proposes a novel approach to chew count estimation using particle swarm optimization (PSO) combined with a peak detection algorithm. The chewing dataset comprises signals collected from 20 participants consuming eight different food types, with proximity sensors detecting temporalis muscle activity. The peak detection algorithm identifies key signal features, while PSO optimizes the peak prominence and width parameters to minimize the Mean Absolute Error (MAE) in chew count estimation. Two specific chewing cycle approaches were implemented: a participants-based (P) cycle and a participants-food type-based (PF) cycle. These approaches were compared to the traditional All (A) chewing cycle method, which evaluates chew count across the entire dataset in a single analysis. Results demonstrate that the PF method yields the lowest MAE at 1.25%, followed by the P method at 3.46%, and the A method at 4.26%. Moreover, the PF method required the least computational time at 8012.2 seconds, compared to 9392.0 seconds for the P method and 36621.4 seconds for the A.


  • Open Access

    Analysis of Exhaled Human Breaths using Graphene Gas Sensor Based on the Male Gender

    by Nur Hazah Shamsudin, Siti Amaniah Mohd Chachuli, Calvin Jeffry Jalan, Omer Coban, Nazreen Waeleh, Siti Aisah Mat Junos, Nur Asmiza Selamat, Nursabillilah Mohd Ali

    Breath analysis is an intriguing method that has the potential to significantly improve non-implantable physical health management via the use of flexible sensors to monitor breathing behaviours. In comparison to other analytical techniques for detecting breath elements, non-invasive breathing diagnostics based on chemical sensors can provide numerous benefits, including nanotechnology, power efficiency, simplicity of structure, and cost-effectiveness, contributing to the flexibility of experimental studies. This paper presents the graphene-based human breath sensor. Graphene was prepared in a paste form by mixing the graphene powder with two types of the binder. Two binders were prepared to compare their performance to human breath. The graphene paste was deposited using screen-printing on different substrates, Kapton film, and glass. The sensing film was thermally annealed at 200°C for 30 minutes and characterized using SEM and FTIR. All graphene gas sensor samples responded well to collected male human breath samples: Bumiputera (Sarawak), Malay, Chinese, and Indian. The best graphene gas sensor for males was OG-T(G) and OG-T(K) with sensitivity, S=1.10415 and S=1.01629. Based on the comparison results of male human breath, the fastest response time and recovery time were 0.52s and 13s, respectively.

  • A Novel Peak Detection Algorithm Using Particle Swarm Optimization for Chew Count Estimation of a Contactless Chewing Detection

    by Nur Asmiza Selamat, Sawal Hamid Md. Ali, Khairun Nisa' Binti Minhad, Siti Anom Ahmad, Jahariah Sampe

    This paper uses a proximity sensor to perform non-contact-based (sensing) chewing activity detection, capturing the temporalis muscle movement during food intake. The proposed approach is validated using data from a larger number of participants, 20, and different food types, eight. The proposed chewing detection classifies the chewing activity with an overall accuracy of 96.4% using a medium Gaussian Support Vector Machine (SVM). In accordance with the result, this paper proposes a novel chew count estimation based on particle swarm optimization (PSO). First, the base of the algorithm is developed based on counting the peak of the chewing signal. Next, the insignificant peak is removed by introducing an argument of minimum peak prominence and maximum peak width where the value of the parameters needs to be determined. As the individual chewing pattern varies from person to person, this paper uses a novel parameter search using the PSO method to find the multiplier (parameter values) according to the average peak prominence and width value within each chewing episode. The proposed estimation approach simplifies the typical trial-and-error method. During optimization, within 100 iterations, the chewing count is reduced by 12.9% from its first iteration. Overall, the proposed methods achieve a 4.26% mean absolute error of chewing count estimation.


  • Open Access

    Automatic Food Intake Monitoring Based on Chewing Activity: A Survey

    by Nur Asmiza Selamat, Sawal Hamid Md. Ali

    Good nutrition is essential for optimal growth, development, and prevention of disease. Due to the importance of nutrition in human life, researchers have been interested in understanding the science of assessing food intake episodes for decades. With the advancement of technology, automated food monitoring tool develops with the help of sensors to address issues related to self-reporting methods. Food monitoring technology is evolving rapidly due to the advancement of sensors; however, automatic monitoring of food intake remains open problems to be solved. For food intake episode detection and monitoring, the sensors used to detect bites, chew, swallow, and hand gestures movement. This survey will be focusing on chewing activity detection during eating episodes. In this survey, a wide range of chewing activity detection explored to outline the sensing design, classification methods, performances, chewing parameters, chewing data analysis as well as the challenges and limitations associated with them.


  • Lead Acid Battery Analysis using S-Transform

    by Muhammad Sufyan Safwan Mohamad Basir, Abdul Rahim Abdullah, Nur Asmiza Selamat, Haslinda Musa, Rahifa Ranom

  • Lead Acid Battery Analysis Using Spectogram

    by Rizanaliah Kasim, Abdul Rahim Abdullah, Nur Asmiza Selamat, N.A. Abidullah, Tengku Nor Shuhadah Tengku Zawawi

    Renewable energy is an alternative option that can be substituted for future energy demand. Many type of battery are used in commerce to propel portable power and this makes the task of selecting the right battery type is crucial. This paper presents the analysis of voltage charging and discharging for lead acid battery using time-frequency distribution (TFD) which is spectrogram. Spectogram technique is used to represent the signals in the time-frequency representation (TFR). The parameter of a signal such as instantaneous root mean square (RMS) voltage, direct current voltage (VDC) and alternating current voltage (VAC) are estimated from the TFR to identify the signal characteristics. This analysis, focus on lead-acid battery with nominal battery voltage of 6 and 12V and storage capacity from 5 until 50Ah. The battery is a model using MATLAB/SIMULINK and the results show that spectrogram technique is capable to identify and determine the signal characteristic of Lead Acid battery.