Mohammed Bhuiyan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mohammed Bhuiyan has a total of 90 co-authors. Here are the top co-authors by number of shared publications:
Branislava Janic
Radiation Oncology and ‡Department of Neurology, Henry Ford Hospital, Detroit, Michigan 48202, United States
4 shared publicationsTamaki Kato
Kyushu Institute of Technology
4 shared publications- Chin-Tu Chen
Department of Radiology, The University of Chicago, Chicago, IL 60637, USA
3 shared publications - Minoru Yoshida
Graduate School of Agricultural and Life Sciences, The University of Tokyo
3 shared publications Norikazu Nishino
Graduate School of Life Science and Systems Engineering, Kyushu Institute of Technology, Kitakyushu 808-0196, Japan
3 shared publicationsRichard Freifelder
Department of Radiology University of Chicago Chicago Illinois USA
3 shared publications
Latest Publications
- Open Access
Efficient Synthesis and HPLC-Based Characterization for Developing Vanadium-48-Labeled Vanadyl Acetylacetonate as a Novel Cancer Radiotracer for PET Imaging
Bis(acetylacetonato)oxidovanadium(IV) [(VO(acac)2], generally known as vanadyl acetylacetonate, has been shown to be preferentially sequestered in malignant tissue. Vanadium-48 (48V) generated with a compact medical cyclotron has been used to label VO(acac)2 as a potential radiotracer in positron emission tomography (PET) imaging for the detection of cancer, but requires lengthy synthesis. Current literature protocols for the characterization of VO(acac)2 require macroscale quantities of reactants and solvents to identify products by color and to enable crystallization that are not readily adaptable to the needs of radiotracer synthesis. We present an improved method to produce vanadium-48-labeled VO(acac)2, [48V]VO(acac)2, and characterize it using high-performance liquid chromatography (HPLC) with radiation detection in combination with UV detection. The approach is suitable for radiotracer-level quantities of material. These methods are readily applicable for production of [48V]VO(acac)2. Preliminary results of preclinical, small-animal PET studies are presented.
Open AccessEfficient Synthesis and HPLC-Based Characterization for Developing Vanadium-48-Labeled Vanadyl Acetylacetonate as a Novel Cancer Radiotracer for PET Imaging
Bis(acetylacetonato)oxidovanadium(IV) [(VO(acac)2], generally known as vanadyl acetylacetonate, has been shown to be preferentially sequestered in malignant tissue. Vanadium-48 (48V) generated with a compact medical cyclotron has been used to label VO(acac)2 as a potential radiotracer in positron emission tomography (PET) imaging for the detection of cancer, but requires lengthy synthesis. Current literature protocols for the characterization of VO(acac)2 require macroscale quantities of reactants and solvents to identify products by color and to enable crystallization that are not readily adaptable to the needs of radiotracer synthesis. We present an improved method to produce vanadium-48-labeled VO(acac)2, [48V]VO(acac)2, and characterize it using high-performance liquid chromatography (HPLC) with radiation detection in combination with UV detection. The approach is suitable for radiotracer-level quantities of material. These methods are readily applicable for production of [48V]VO(acac)2. Preliminary results of preclinical, small-animal PET studies are presented.
- Open Access
- 5 November 2023
- Published by Wiley in Journal of Labelled Compounds and Radiopharmaceuticals
- Vol. 67 (1) , 31-36
A simplified protocol for the automated production of 2‐[18F]fluoro‐3‐[2‐((S)‐3‐pyrrolinyl)methoxy]pyridine ([18F]nifene) on an IBA Synthera® module
The α4β2 nicotinic acetylcholine receptor (nAChR) ligand 2‐[18F]fluoro‐3‐[2‐((S)‐3‐pyrrolinyl)methoxy]pyridine ([18F]nifene) has been synthesized in 10% decay‐corrected radiochemical yield using the IBA Synthera® platform (IBA Cyclotron Solutions, Louvain‐la‐Neuve, Belgium) with an integrated fluidic processor (IFP). Boc‐nitronifene served as the precursor, and 20% trifluoroacetic acid (TFA) was used to deprotect the Boc‐group after radiolabeling. By omitting the solvent extraction step after radiolabeling, the process was simplified to a single step with no manual intervention. [18F]Nifene was obtained in decay‐corrected radiochemical yields of 10 ± 2% (n = 20) and radiochemical purity >99%. Typical specific radioactivities of 2700–4865 mCi/μmole (100–180 GBq/μmol) were measured at the end of synthesis; total synthesis times were about 1 h 40 min.
- 5 November 2023
- Published by Wiley in Journal of Labelled Compounds and Radiopharmaceuticals
- Vol. 67 (1) , 31-36
Open AccessA simplified protocol for the automated production of 2‐[18F]fluoro‐3‐[2‐((S)‐3‐pyrrolinyl)methoxy]pyridine ([18F]nifene) on an IBA Synthera® module
The α4β2 nicotinic acetylcholine receptor (nAChR) ligand 2‐[18F]fluoro‐3‐[2‐((S)‐3‐pyrrolinyl)methoxy]pyridine ([18F]nifene) has been synthesized in 10% decay‐corrected radiochemical yield using the IBA Synthera® platform (IBA Cyclotron Solutions, Louvain‐la‐Neuve, Belgium) with an integrated fluidic processor (IFP). Boc‐nitronifene served as the precursor, and 20% trifluoroacetic acid (TFA) was used to deprotect the Boc‐group after radiolabeling. By omitting the solvent extraction step after radiolabeling, the process was simplified to a single step with no manual intervention. [18F]Nifene was obtained in decay‐corrected radiochemical yields of 10 ± 2% (n = 20) and radiochemical purity >99%. Typical specific radioactivities of 2700–4865 mCi/μmole (100–180 GBq/μmol) were measured at the end of synthesis; total synthesis times were about 1 h 40 min.
- Open Access
- 24 October 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (21) , 15510
Evaluation of an Image-Derived Input Function for Kinetic Modeling of Nicotinic Acetylcholine Receptor-Binding PET Ligands in Mice
Positron emission tomography (PET) radioligands that bind with high-affinity to α4β2-type nicotinic receptors (α4β2Rs) allow for in vivo investigations of the mechanisms underlying nicotine addiction and smoking cessation. Here, we investigate the use of an image-derived arterial input function and the cerebellum for kinetic analysis of radioligand binding in mice. Two radioligands were explored: 2-[18F]FA85380 (2-FA), displaying similar pKa and binding affinity to the smoking cessation drug varenicline (Chantix), and [18F]Nifene, displaying similar pKa and binding affinity to nicotine. Time–activity curves of the left ventricle of the heart displayed similar distribution across wild type mice, mice lacking the β2-subunit for ligand binding, and acute nicotine-treated mice, whereas reference tissue binding displayed high variation between groups. Binding potential estimated from a two-tissue compartment model fit of the data with the image-derived input function were higher than estimates from reference tissue-based estimations. Rate constants of radioligand dissociation were very slow for 2-FA and very fast for Nifene. We conclude that using an image-derived input function for kinetic modeling of nicotinic PET ligands provides suitable results compared to reference tissue-based methods and that the chemical properties of 2-FA and Nifene are suitable to study receptor response to nicotine addiction and smoking cessation therapies.
- 24 October 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (21) , 15510
Open AccessEvaluation of an Image-Derived Input Function for Kinetic Modeling of Nicotinic Acetylcholine Receptor-Binding PET Ligands in Mice
Positron emission tomography (PET) radioligands that bind with high-affinity to α4β2-type nicotinic receptors (α4β2Rs) allow for in vivo investigations of the mechanisms underlying nicotine addiction and smoking cessation. Here, we investigate the use of an image-derived arterial input function and the cerebellum for kinetic analysis of radioligand binding in mice. Two radioligands were explored: 2-[18F]FA85380 (2-FA), displaying similar pKa and binding affinity to the smoking cessation drug varenicline (Chantix), and [18F]Nifene, displaying similar pKa and binding affinity to nicotine. Time–activity curves of the left ventricle of the heart displayed similar distribution across wild type mice, mice lacking the β2-subunit for ligand binding, and acute nicotine-treated mice, whereas reference tissue binding displayed high variation between groups. Binding potential estimated from a two-tissue compartment model fit of the data with the image-derived input function were higher than estimates from reference tissue-based estimations. Rate constants of radioligand dissociation were very slow for 2-FA and very fast for Nifene. We conclude that using an image-derived input function for kinetic modeling of nicotinic PET ligands provides suitable results compared to reference tissue-based methods and that the chemical properties of 2-FA and Nifene are suitable to study receptor response to nicotine addiction and smoking cessation therapies.
- Open Access
Accelerator-Based Production of Scandium Radioisotopes for Applications in Prostate Cancer: Toward Building a Pipeline for Rapid Development of Novel Theranostics
In the field of nuclear medicine, the β+ -emitting 43Sc and β− -emitting 47Sc are promising candidates in cancer diagnosis and targeted radionuclide therapy (TRT) due to their favorable decay schema and shared pharmacokinetics as a true theranostic pair. Additionally, scandium is a group-3 transition metal (like 177Lu) and exhibits affinity for DOTA-based chelators, which have been studied in depth, making the barrier to implementation lower for 43/47Sc than for other proposed true theranostics. Before 43/47Sc can see widespread pre-clinical evaluation, however, an accessible production methodology must be established and each isotope’s radiolabeling and animal imaging capabilities studied with a widely utilized tracer. As such, a simple means of converting an 18 MeV biomedical cyclotron to support solid targets and produce 43Sc via the 42Ca(d,n)43Sc reaction has been devised, exhibiting reasonable yields. The NatTi(γ,p)47Sc reaction is also investigated along with the successful implementation of chemical separation and purification methods for 43/47Sc. The conjugation of 43/47Sc with PSMA-617 at specific activities of up to 8.94 MBq/nmol and the subsequent imaging of LNCaP-ENZaR tumor xenografts in mouse models with both 43/47Sc-PSMA-617 are also presented.
Open AccessAccelerator-Based Production of Scandium Radioisotopes for Applications in Prostate Cancer: Toward Building a Pipeline for Rapid Development of Novel Theranostics
In the field of nuclear medicine, the β+ -emitting 43Sc and β− -emitting 47Sc are promising candidates in cancer diagnosis and targeted radionuclide therapy (TRT) due to their favorable decay schema and shared pharmacokinetics as a true theranostic pair. Additionally, scandium is a group-3 transition metal (like 177Lu) and exhibits affinity for DOTA-based chelators, which have been studied in depth, making the barrier to implementation lower for 43/47Sc than for other proposed true theranostics. Before 43/47Sc can see widespread pre-clinical evaluation, however, an accessible production methodology must be established and each isotope’s radiolabeling and animal imaging capabilities studied with a widely utilized tracer. As such, a simple means of converting an 18 MeV biomedical cyclotron to support solid targets and produce 43Sc via the 42Ca(d,n)43Sc reaction has been devised, exhibiting reasonable yields. The NatTi(γ,p)47Sc reaction is also investigated along with the successful implementation of chemical separation and purification methods for 43/47Sc. The conjugation of 43/47Sc with PSMA-617 at specific activities of up to 8.94 MBq/nmol and the subsequent imaging of LNCaP-ENZaR tumor xenografts in mouse models with both 43/47Sc-PSMA-617 are also presented.
- 15 June 2020
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 59 (35) , 15161-15165
In Vivo Imaging of the Tumor‐Associated Enzyme NCEH1 with a Covalent PET Probe
Herein, we report the development of an 18F‐labeled, activity‐based small‐molecule probe targeting the cancer‐associated serine hydrolase NCEH1. We undertook a focused medicinal chemistry campaign to simultaneously preserve potent and specific NCEH1 labeling in live cells and animals, while permitting facile 18F radionuclide incorporation required for PET imaging. The resulting molecule, [18F]JW199, labels active NCEH1 in live cells at nanomolar concentrations and greater than 1000‐fold selectivity relative to other serine hydrolases. [18F]JW199 displays rapid, NCEH1‐dependent accumulation in mouse tissues. Finally, we demonstrate that [18F]JW199 labels aggressive cancer tumor cells in vivo, which uncovered localized NCEH1 activity at the leading edge of triple‐negative breast cancer tumors, suggesting roles for NCEH1 in tumor aggressiveness and metastasis.
- 15 June 2020
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 59 (35) , 15161-15165
In Vivo Imaging of the Tumor‐Associated Enzyme NCEH1 with a Covalent PET Probe
Herein, we report the development of an 18F‐labeled, activity‐based small‐molecule probe targeting the cancer‐associated serine hydrolase NCEH1. We undertook a focused medicinal chemistry campaign to simultaneously preserve potent and specific NCEH1 labeling in live cells and animals, while permitting facile 18F radionuclide incorporation required for PET imaging. The resulting molecule, [18F]JW199, labels active NCEH1 in live cells at nanomolar concentrations and greater than 1000‐fold selectivity relative to other serine hydrolases. [18F]JW199 displays rapid, NCEH1‐dependent accumulation in mouse tissues. Finally, we demonstrate that [18F]JW199 labels aggressive cancer tumor cells in vivo, which uncovered localized NCEH1 activity at the leading edge of triple‐negative breast cancer tumors, suggesting roles for NCEH1 in tumor aggressiveness and metastasis.
- Open Access
- 29 May 2017
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 123,p. e55537
Automated Radiochemical Synthesis of [18F]3F4AP: A Novel PET Tracer for Imaging Demyelinating Diseases
3-[18F]fluoro-4-aminopyridine, [18F]3F4AP, is a radiofluorinated analog of the FDA-approved drug for multiple sclerosis 4-aminopyridine (4AP). This compound is currently under investigation as a PET tracer for demyelination. We recently described a novel chemical reaction to produce metafluorinated pyridines consisting of direct fluorination of a pyridine N-oxide and the utilization of this reaction for the radiochemical synthesis of [18F]3F4AP. In this article, we demonstrate how to produce this tracer using an automated synthesizer and an in-house made flow hydrogenation reactor. We also show the standard quality control procedures performed before releasing the radiotracer for preclinical animal imaging studies. This semi-automated procedure may serve as the basis for future production of [18F]3F4AP for clinical studies.
- 29 May 2017
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 123,p. e55537
Open AccessAutomated Radiochemical Synthesis of [18F]3F4AP: A Novel PET Tracer for Imaging Demyelinating Diseases
3-[18F]fluoro-4-aminopyridine, [18F]3F4AP, is a radiofluorinated analog of the FDA-approved drug for multiple sclerosis 4-aminopyridine (4AP). This compound is currently under investigation as a PET tracer for demyelination. We recently described a novel chemical reaction to produce metafluorinated pyridines consisting of direct fluorination of a pyridine N-oxide and the utilization of this reaction for the radiochemical synthesis of [18F]3F4AP. In this article, we demonstrate how to produce this tracer using an automated synthesizer and an in-house made flow hydrogenation reactor. We also show the standard quality control procedures performed before releasing the radiotracer for preclinical animal imaging studies. This semi-automated procedure may serve as the basis for future production of [18F]3F4AP for clinical studies.
- 12 August 2016
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 1 (8) , 975-978
pH-Dependent Cellular Internalization of Paramagnetic Nanoparticle
A hallmark of the tumor microenvironment in malignant tumor is extracellular acidosis, which can be exploited for targeted delivery of drugs and imaging agents. A pH sensitive paramagnetic nanoaparticle (NP) is developed by incorporating GdDOTA-4AmP MRI contrast agent and pHLIP (pH Low Insertion Peptide) into the surface of a G5–PAMAM dendrimer. pHLIP showed pH-selective insertion and folding into cell membranes, but only in acidic conditions. We demonstrated that pHLIP-conjugated Gd44-G5 paramagnetic nanoparticle binds and fuses with cellular membrane at low pH, but not at normal physiological pH, and that it promotes cellular uptake. Intracellular trafficking of NPs showed endosomal/lysosomal path ways.
- 12 August 2016
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 1 (8) , 975-978
pH-Dependent Cellular Internalization of Paramagnetic Nanoparticle
A hallmark of the tumor microenvironment in malignant tumor is extracellular acidosis, which can be exploited for targeted delivery of drugs and imaging agents. A pH sensitive paramagnetic nanoaparticle (NP) is developed by incorporating GdDOTA-4AmP MRI contrast agent and pHLIP (pH Low Insertion Peptide) into the surface of a G5–PAMAM dendrimer. pHLIP showed pH-selective insertion and folding into cell membranes, but only in acidic conditions. We demonstrated that pHLIP-conjugated Gd44-G5 paramagnetic nanoparticle binds and fuses with cellular membrane at low pH, but not at normal physiological pH, and that it promotes cellular uptake. Intracellular trafficking of NPs showed endosomal/lysosomal path ways.
- Open Access
- 14 July 2015
- Published by Wiley in Contrast Media & Molecular Imaging
- Vol. 10 (6) , 481-486
Concentration‐independent MRI of pH with a dendrimer‐based pH‐responsive nanoprobe
The measurement of extracellular pH (pHe) has significant clinical value for pathological diagnoses and for monitoring the effects of pH‐altering therapies. One of the major problems of measuring pHe with a relaxation‐based MRI contrast agent is that the longitudinal relaxivity depends on both pH and the concentration of the agent, requiring the use of a second pH‐unresponsive agent to measure the concentration. Here we tested the feasibility of measuring pH with a relaxation‐based dendritic MRI contrast agent in a concentration‐independent manner at clinically relevant field strengths. The transverse and longitudinal relaxation times in solutions of the contrast agent (GdDOTA‐4AmP)44‐G5, a G5–PAMAM dendrimer‐based MRI contrast agent in water, were measured at 3 T and 7 T magnetic field strengths as a function of pH. At 3 T, longitudinal relaxivity (r1) increased from 7.91 to 9.65 mM−1 s−1 (on a per Gd3+ basis) on changing pH from 8.84 to 6.35. At 7 T, r1 relaxivity showed pH response, albeit at lower mean values; transverse relaxivity (r2) remained independent of pH and magnetic field strengths. The longitudinal relaxivity of (GdDOTA‐4AmP)44‐G5 exhibited a strong and reversible pH dependence. The ratio of relaxation rates R2/R1 also showed a linear relationship in a pH‐responsive manner, and this pH response was independent of the absolute concentration of (GdDOTA‐4AmP)44‐G5 agent. Importantly, the nanoprobe (GdDOTA‐4AmP)44‐G5 shows pH response in the range commonly found in the microenvironment of solid tumors. Copyright © 2015 John Wiley & Sons, Ltd.
- 14 July 2015
- Published by Wiley in Contrast Media & Molecular Imaging
- Vol. 10 (6) , 481-486
Open AccessConcentration‐independent MRI of pH with a dendrimer‐based pH‐responsive nanoprobe
The measurement of extracellular pH (pHe) has significant clinical value for pathological diagnoses and for monitoring the effects of pH‐altering therapies. One of the major problems of measuring pHe with a relaxation‐based MRI contrast agent is that the longitudinal relaxivity depends on both pH and the concentration of the agent, requiring the use of a second pH‐unresponsive agent to measure the concentration. Here we tested the feasibility of measuring pH with a relaxation‐based dendritic MRI contrast agent in a concentration‐independent manner at clinically relevant field strengths. The transverse and longitudinal relaxation times in solutions of the contrast agent (GdDOTA‐4AmP)44‐G5, a G5–PAMAM dendrimer‐based MRI contrast agent in water, were measured at 3 T and 7 T magnetic field strengths as a function of pH. At 3 T, longitudinal relaxivity (r1) increased from 7.91 to 9.65 mM−1 s−1 (on a per Gd3+ basis) on changing pH from 8.84 to 6.35. At 7 T, r1 relaxivity showed pH response, albeit at lower mean values; transverse relaxivity (r2) remained independent of pH and magnetic field strengths. The longitudinal relaxivity of (GdDOTA‐4AmP)44‐G5 exhibited a strong and reversible pH dependence. The ratio of relaxation rates R2/R1 also showed a linear relationship in a pH‐responsive manner, and this pH response was independent of the absolute concentration of (GdDOTA‐4AmP)44‐G5 agent. Importantly, the nanoprobe (GdDOTA‐4AmP)44‐G5 shows pH response in the range commonly found in the microenvironment of solid tumors. Copyright © 2015 John Wiley & Sons, Ltd.
- 1 October 2014
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 202, 1237-1242
A self-catalytic colorimetric visualization assay for cancer cell detection
- 1 October 2014
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 202, 1237-1242
A self-catalytic colorimetric visualization assay for cancer cell detection
- 18 December 2012
- Published by Taylor & Francis in Nanomedicine
- Vol. 7 (12) , 1827-1837
A Nano-Sized PARAcest-Fluorescence Imaging Contrast Agent Facilitates and Validates In Vivo CEST MRI Detection of Glioma
Aim: The authors have investigated the usefulness of in vivo chemical exchange saturation transfer MRI for detecting gliomas using a dual-modality imaging contrast agent. Materials & methods: A paramagnetic chemical exchange saturation transfer MRI contrast agent, Eu-1,4,7,10-tetraazacclododecane-1,4,7,10-tetraacetic acid-Gly4 and a fluorescent agent, DyLight® 680, were conjugated to a generation 5 polyamidoamine dendrimer to create the dual-modality, nano-sized imaging contrast agent. Results: The agent was detected with in vivo chemical exchange saturation transfer MRI in an U87 glioma model. These results were validated using in vivo and ex vivo fluorescence imaging. Conclusion: This study demonstrated the merits of using a nano-sized imaging contrast agent for detecting gliomas and using a dual-modality agent for detecting gliomas at different spatial scales. Original submitted 9 January 2012; Revised submitted 18 April 2012; Published online 14 August 2012
- 18 December 2012
- Published by Taylor & Francis in Nanomedicine
- Vol. 7 (12) , 1827-1837
A Nano-Sized PARAcest-Fluorescence Imaging Contrast Agent Facilitates and Validates In Vivo CEST MRI Detection of Glioma
Aim: The authors have investigated the usefulness of in vivo chemical exchange saturation transfer MRI for detecting gliomas using a dual-modality imaging contrast agent. Materials & methods: A paramagnetic chemical exchange saturation transfer MRI contrast agent, Eu-1,4,7,10-tetraazacclododecane-1,4,7,10-tetraacetic acid-Gly4 and a fluorescent agent, DyLight® 680, were conjugated to a generation 5 polyamidoamine dendrimer to create the dual-modality, nano-sized imaging contrast agent. Results: The agent was detected with in vivo chemical exchange saturation transfer MRI in an U87 glioma model. These results were validated using in vivo and ex vivo fluorescence imaging. Conclusion: This study demonstrated the merits of using a nano-sized imaging contrast agent for detecting gliomas and using a dual-modality agent for detecting gliomas at different spatial scales. Original submitted 9 January 2012; Revised submitted 18 April 2012; Published online 14 August 2012