Beom Jun Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Beom Jun Kim has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Min Soo Kim
Seoul National University
3 shared publications - Byungchan Han
Department of Chemical and Biomolecular Engineering, Yonsei University, Seoul 03722, Republic of Korea
2 shared publications Kyung Don Baik
2 shared publicationsTae-Young Kim
Hydrogen & Fuel Cell Center, New & Renewable Energy Research Division, Korea Institute of Energy Research (KIER), 20-41, Sinjaesaengeneogi-ro, Haseo-myeon, Buan-gun, Jellabuk-do, Korea
2 shared publicationsYoung-Gi Yoon
Hydrogen & Fuel Cell Center, New & Renewable Energy Research Division, Korea Institute of Energy Research (KIER), 20-41, Sinjaesaengeneogi-ro, Haseo-myeon, Buan-gun, Jellabuk-do, Korea
2 shared publicationsAeri Jung
1 shared publication
Latest Publications
- 24 November 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-02 (43) , 2211
Research on Durability Testing, Fault Diagnosis, and Lifetime Prediction of Polymer Electrolyte Fuel Cells Under Accelerated Stress Operations
When the performance of polymer electrolyte fuel cells (PEFCs) falls below a certain level, it is necessary to either dispose of them for the recycling of platinum and other materials or remanufacture them for other uses. To do this, it is essential to develop a device that can diagnose failures in used stacks, predict the remaining useful life, and identify faulty components such as the catalyst layer, membrane, gasket and so on. Accurate fault diagnosis enables precise identification of defective areas, which can then be used to improve the durability of specific parts and enhance the overall durability of subsequent stacks. In this study, two self-manufactured stacks, each consisting of five cells with a reaction area of 200 cm², were subjected to long-term experiments under load variations and start-stop cycles. Through periodic performance diagnostics, the rate of performance degradation was measured, and a functional expression was derived for estimating the remaining useful life. Furthermore, a diagnostic device was developed to automatically perform leak testing, detect pinholes in the electrolyte membrane, and conduct impedance spectroscopy under in-situ condition, enabling rapid identification of failure locations in the fuel cell stacks. After identifying the fault areas using this device, the results were compared with those from accelerated tests to verify accuracy. The failure diagnosis device developed in this study is expected to contribute to enhancing the utility and economic efficiency of fuel cells by enabling end-of-life failure diagnosis and lifespan prediction from a full life-cycle perspective of polymer electrolyte fuel cells.
- 24 November 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-02 (43) , 2211
Research on Durability Testing, Fault Diagnosis, and Lifetime Prediction of Polymer Electrolyte Fuel Cells Under Accelerated Stress Operations
When the performance of polymer electrolyte fuel cells (PEFCs) falls below a certain level, it is necessary to either dispose of them for the recycling of platinum and other materials or remanufacture them for other uses. To do this, it is essential to develop a device that can diagnose failures in used stacks, predict the remaining useful life, and identify faulty components such as the catalyst layer, membrane, gasket and so on. Accurate fault diagnosis enables precise identification of defective areas, which can then be used to improve the durability of specific parts and enhance the overall durability of subsequent stacks. In this study, two self-manufactured stacks, each consisting of five cells with a reaction area of 200 cm², were subjected to long-term experiments under load variations and start-stop cycles. Through periodic performance diagnostics, the rate of performance degradation was measured, and a functional expression was derived for estimating the remaining useful life. Furthermore, a diagnostic device was developed to automatically perform leak testing, detect pinholes in the electrolyte membrane, and conduct impedance spectroscopy under in-situ condition, enabling rapid identification of failure locations in the fuel cell stacks. After identifying the fault areas using this device, the results were compared with those from accelerated tests to verify accuracy. The failure diagnosis device developed in this study is expected to contribute to enhancing the utility and economic efficiency of fuel cells by enabling end-of-life failure diagnosis and lifespan prediction from a full life-cycle perspective of polymer electrolyte fuel cells.
- 31 March 2017
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 9 (22) , 7373-7379
Self-assembled nitrogen-doped fullerenes and their catalysis for fuel cell and rechargeable metal–air battery applications
In this study, we report self-assembled nitrogen-doped fullerenes (N-fullerene) as non-precious catalysts, which are active for the oxygen reduction reaction (ORR) and oxygen evolution reaction (OER), and thus applicable for energy conversion and storage devices such as fuel cells and metal–air battery systems. We screen the best N-fullerene catalyst at the nitrogen doping level of 10 at%, not at the previously known doping level of 5 or 20 at% for graphene. We identify that the compressive surface strain induced by doped nitrogen plays a key role in the fine-tuning of catalytic activity.
- 31 March 2017
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 9 (22) , 7373-7379
Self-assembled nitrogen-doped fullerenes and their catalysis for fuel cell and rechargeable metal–air battery applications
In this study, we report self-assembled nitrogen-doped fullerenes (N-fullerene) as non-precious catalysts, which are active for the oxygen reduction reaction (ORR) and oxygen evolution reaction (OER), and thus applicable for energy conversion and storage devices such as fuel cells and metal–air battery systems. We screen the best N-fullerene catalyst at the nitrogen doping level of 10 at%, not at the previously known doping level of 5 or 20 at% for graphene. We identify that the compressive surface strain induced by doped nitrogen plays a key role in the fine-tuning of catalytic activity.
- 1 October 2016
- Published by Elsevier in Journal of Power Sources
- Vol. 328, 75-80
Fast stack activation procedure and effective long-term storage for high-performance polymer electrolyte membrane fuel cell
- 1 October 2016
- Published by Elsevier in Journal of Power Sources
- Vol. 328, 75-80
Fast stack activation procedure and effective long-term storage for high-performance polymer electrolyte membrane fuel cell
- 1 February 2013
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 38 (3) , 1544-1552
Experimental study on mitigating the cathode flooding at low temperature by adding hydrogen to the cathode reactant gas in PEM fuel cell
- 1 February 2013
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 38 (3) , 1544-1552
Experimental study on mitigating the cathode flooding at low temperature by adding hydrogen to the cathode reactant gas in PEM fuel cell
- 1 March 2012
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 37 (5) , 4290-4299
Studies on the cathode humidification by exhaust gas recirculation for PEM fuel cell
- 1 March 2012
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 37 (5) , 4290-4299
Studies on the cathode humidification by exhaust gas recirculation for PEM fuel cell