Karlene A. Hoo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Karlene A. Hoo has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
M.J. Piovoso
Penn State Great Valley School of Graduate Professional Studies
3 shared publicationsYingying Chen
Department of Chemical Engineering, Texas Tech University, Lubbock, TX 79409, USA
3 shared publicationsJeffrey C. Kantor
Department of Chemical Engineering , University of Notre Dame , Notre Dame, IN, 46556
2 shared publicationsM. J. Piovoso
School of Graduate Professional Studies, Penn State University, Malvern, PA 19355, USA
2 shared publicationsN. S. Wijeratne
Department of Chemical Engineering, Lubbock, TX 79409-3121, U.S.A
2 shared publicationsN.S. Wijeratne
Department of Chemical Engineering, Texas Tech University, Lubbock, 79409-3121, USA
2 shared publications
Latest Publications
- Open Access
- 10 May 2013
- Published by Taylor & Francis in Systems Science & Control Engineering
- Vol. 1 (1) , 12-19
Stability analysis for closed-loop management of a reservoir based on identification of reduced-order nonlinear model
This objective of this study is to analyze the stability of an oil producing reservoir under closed-loop control. Given a five-spot pattern reservoir as an example, a nonlinear reduced-order model is identified and an asymptotically stabilizing controller is proposed based on the circle criterion.
- 10 May 2013
- Published by Taylor & Francis in Systems Science & Control Engineering
- Vol. 1 (1) , 12-19
Open AccessStability analysis for closed-loop management of a reservoir based on identification of reduced-order nonlinear model
This objective of this study is to analyze the stability of an oil producing reservoir under closed-loop control. Given a five-spot pattern reservoir as an example, a nonlinear reduced-order model is identified and an asymptotically stabilizing controller is proposed based on the circle criterion.
- 1 August 2012
- Published by Elsevier in Computers & Chemical Engineering
- Vol. 43, 23-32
The development of a maximum likelihood model for model-based applications
- 1 August 2012
- Published by Elsevier in Computers & Chemical Engineering
- Vol. 43, 23-32
The development of a maximum likelihood model for model-based applications
- 4 January 2012
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 51 (2) , 860-871
Optimal Feed Point Design and Regulation of a Novel Plate Reactor
- 4 January 2012
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 51 (2) , 860-871
Optimal Feed Point Design and Regulation of a Novel Plate Reactor
- 8 December 2010
- Published by Taylor & Francis
- p. 17-1
Plantwide Control
- 8 December 2010
- Published by Taylor & Francis
- p. 16-1
The Use of Multivariate Statistics in Process Control
- 8 December 2010
- Published by Taylor & Francis
- p. 16-1
The Use of Multivariate Statistics in Process Control
- 12 October 2010
- Published by Elsevier in Computers & Chemical Engineering
- Vol. 34 (10) , 1597-1605
Uncertainty propagation for effective reduced-order model generation
- 12 October 2010
- Published by Elsevier in Computers & Chemical Engineering
- Vol. 34 (10) , 1597-1605
Uncertainty propagation for effective reduced-order model generation
- 18 August 2010
- Published by Elsevier in Computers & Chemical Engineering
- Vol. 35 (1) , 132-148
Effective fault detection and isolation using bond graph-based domain decomposition
- 18 August 2010
- Published by Elsevier in Computers & Chemical Engineering
- Vol. 35 (1) , 132-148
Effective fault detection and isolation using bond graph-based domain decomposition
- 5 September 2008
- Published by Wiley in Biotechnology Progress
- Vol. 21 (3) , 938-945
Experimental Studies of the Effects of Abnormal Venous Valves on Fluid Flow
The effects of variations in the venous valve anatomy are studied experimentally using an artificial system that mimics the bicuspid valves normally found in veins in the lower extremities. The artificial valves are constructed from thin-walled, latex tubing and polyurethane film. The experimental variables in the study are the gap width between the leaflet attachments at the vein wall and the ratio of the sinus depth to vein diameter. The results show that the antegrade mass flow rate is not affected to the same degree when compared to retrograde flow by the various valve configurations examined in this study. The results also indicate that increases in the gap width, which serve to increase the degree of imperfect wall attachment, have less effect on retrograde mass flow rate in valves with deeper sinuses.
- 5 September 2008
- Published by Wiley in Biotechnology Progress
- Vol. 21 (3) , 938-945
Experimental Studies of the Effects of Abnormal Venous Valves on Fluid Flow
The effects of variations in the venous valve anatomy are studied experimentally using an artificial system that mimics the bicuspid valves normally found in veins in the lower extremities. The artificial valves are constructed from thin-walled, latex tubing and polyurethane film. The experimental variables in the study are the gap width between the leaflet attachments at the vein wall and the ratio of the sinus depth to vein diameter. The results show that the antegrade mass flow rate is not affected to the same degree when compared to retrograde flow by the various valve configurations examined in this study. The results also indicate that increases in the gap width, which serve to increase the degree of imperfect wall attachment, have less effect on retrograde mass flow rate in valves with deeper sinuses.
- 17 June 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 55 (7) , 1831-1839
An Experimental Approach to Measure Mass Diffusion in Rat Tumor Tissue
The objective of this research is to evaluate the usefulness of a macroscopic, fluorescent, imaging technique to quantify spatiotemporal mass transport parameters in in vitro solid tumor tissues taken from rat models. Fluorescent images captured during the experiments are digitally analyzed to determine the concentration of a fluorescent marker dye as it diffuses into tissue specimens taken from rat tumors. The collected concentration data are used to estimate local diffusion coefficients. An analysis of the distribution of the local diffusion data indicates that the local diffusion coefficient is spatially dependent within the tumor tissue. When mass transfer is restricted to one dimension, the current technique can be used to determine the concentration distribution of fluorescent molecules on the tissue surface and to estimate the mass transfer parameters within the heterogeneous tumor tissue.
- 17 June 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 55 (7) , 1831-1839
An Experimental Approach to Measure Mass Diffusion in Rat Tumor Tissue
The objective of this research is to evaluate the usefulness of a macroscopic, fluorescent, imaging technique to quantify spatiotemporal mass transport parameters in in vitro solid tumor tissues taken from rat models. Fluorescent images captured during the experiments are digitally analyzed to determine the concentration of a fluorescent marker dye as it diffuses into tissue specimens taken from rat tumors. The collected concentration data are used to estimate local diffusion coefficients. An analysis of the distribution of the local diffusion data indicates that the local diffusion coefficient is spatially dependent within the tumor tissue. When mass transfer is restricted to one dimension, the current technique can be used to determine the concentration distribution of fluorescent molecules on the tissue surface and to estimate the mass transfer parameters within the heterogeneous tumor tissue.
- 1 June 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 6 (07431619) , 147-152
Numerical studies on the hemodynamics in the human vein and venous valve
Proper blood flow in the veins are important to ensure effective return of deoxygenated blood to the heart. A major element of the human venous system is the presence of one-way, flexible, bicuspid valves in the legs that allow antegrade blood flow while preventing retrograde flow. Veins are elastic in nature thus their lumens can collapse under external forces and distend under internal pressures. Fluid flow within such flexible structures is regulated by the stresses imposed upon and by the structure, the material properties of the fluid, and the presence and function of the internal valve. As a result of viscous forces and fluid pressure the flexible structures are subject to continuous displacement. The primary objective of this study is to develop a two-dimensional computational model of non-Newtonian fluid flow within and around flexible structures. Accurate numerical solutions of this system provide a means of connecting venous valve incompetence and fluid flow behavior to the onset of cardiovascular limitations.
- 1 June 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 6 (07431619) , 147-152
Numerical studies on the hemodynamics in the human vein and venous valve
Proper blood flow in the veins are important to ensure effective return of deoxygenated blood to the heart. A major element of the human venous system is the presence of one-way, flexible, bicuspid valves in the legs that allow antegrade blood flow while preventing retrograde flow. Veins are elastic in nature thus their lumens can collapse under external forces and distend under internal pressures. Fluid flow within such flexible structures is regulated by the stresses imposed upon and by the structure, the material properties of the fluid, and the presence and function of the internal valve. As a result of viscous forces and fluid pressure the flexible structures are subject to continuous displacement. The primary objective of this study is to develop a two-dimensional computational model of non-Newtonian fluid flow within and around flexible structures. Accurate numerical solutions of this system provide a means of connecting venous valve incompetence and fluid flow behavior to the onset of cardiovascular limitations.