Alexandros Pino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alexandros Pino has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Georgios Kouroupetroglou
National and Kapodistrian University of Athens, Athens, Greece
14 shared publications Nikolaos Papatheodorou
Speech and Accessibility Laboratory, Department of Informatics and Telecommunications, National and Kapodistrian University of Athens, Athens, Greece
3 shared publicationsCharalambos Papageorgiou
Eginition Hospital, School of Medicine, National and Kapodistrian University of Athens, Athens, Greece
2 shared publications- Dimitrios Vrailas
Department of Informatics and Telecommunications, National and Kapodistrian University of Athens, 15784 Athens, Greece
2 shared publications - Dimitris Spiliotopoulos
Department of Management Science and Technology, University of the Peloponnese, Sehi Location (Former 4th Shooting Range), 221 31 Tripoli, Greece
2 shared publications Elisabeth Andreadou
Aeginition Hospital, National and Kapodistrian University of Athens, GR-11528, Athens, Greece
2 shared publications
Latest Publications
- Open Access
Comparison of Point-and-Click Performance Between the Brainfingers BCI and the Mouse
This study quantitatively evaluates the performance of a non-invasive hybrid brain–computer interface (BCI) compared to a conventional mouse in pointing (point-and-click) tasks. A commercial wearable BCI (Brainfingers), based on electromyography (EMG) and electrooculography (EOG) signals with low-level electroencephalography (EEG) components, was assessed against a Microsoft Optical Mouse using ISO/TS 9241-411-based one-dimensional (1D) and two-dimensional (2D) target acquisition tasks. Pointer coordinates were recorded and analyzed using Fitts’ law metrics. A total of 48 non-disabled participants completed the experiments. The results reveal significant performance differences between the two input devices. The BCI device exhibits substantially lower performance than the mouse across the reported Fitts’ law measures. Mean throughput was 0.35 bits/s for the BCI and 6.03 bits/s for the mouse in the 1D tests and 0.43 bits/s for the BCI and 5.17 bits/s for the mouse in the 2D tests. Despite the BCI’s low performance and although the present experiments involved non-disabled participants, the findings, considered alongside the prior literature on Brainfingers and non-invasive BCIs for computer access, suggest that the device may still have assistive technology value for users with severe motor impairments.
Open AccessComparison of Point-and-Click Performance Between the Brainfingers BCI and the Mouse
This study quantitatively evaluates the performance of a non-invasive hybrid brain–computer interface (BCI) compared to a conventional mouse in pointing (point-and-click) tasks. A commercial wearable BCI (Brainfingers), based on electromyography (EMG) and electrooculography (EOG) signals with low-level electroencephalography (EEG) components, was assessed against a Microsoft Optical Mouse using ISO/TS 9241-411-based one-dimensional (1D) and two-dimensional (2D) target acquisition tasks. Pointer coordinates were recorded and analyzed using Fitts’ law metrics. A total of 48 non-disabled participants completed the experiments. The results reveal significant performance differences between the two input devices. The BCI device exhibits substantially lower performance than the mouse across the reported Fitts’ law measures. Mean throughput was 0.35 bits/s for the BCI and 6.03 bits/s for the mouse in the 1D tests and 0.43 bits/s for the BCI and 5.17 bits/s for the mouse in the 2D tests. Despite the BCI’s low performance and although the present experiments involved non-disabled participants, the findings, considered alongside the prior literature on Brainfingers and non-invasive BCIs for computer access, suggest that the device may still have assistive technology value for users with severe motor impairments.
- Open Access
- 3 April 2026
- Published by MDPI AG in Preprints.org
Comparison of Point-and-Click Performance Between the Brainfingers BCI and the Mouse
This study quantitatively evaluates the performance of a non-invasive hybrid brain–computer interface (BCI) compared to a conventional mouse in pointing (point-and-click) tasks. A commercial wearable BCI (Brainfingers), based on electromyography (EMG) and electrooculography (EOG) signals with low-level electroencephalography (EEG) components, was assessed against a Microsoft Optical Mouse using ISO/TS 9241-411-based one-dimensional (1D) and two-dimensional (2D) target acquisition tasks. Pointer coordinates were recorded and analyzed using Fitts’ law metrics. A total of 48 non-disabled participants completed the experiments. The results reveal significant performance differences between the two input devices. The BCI device exhibits substantially lower performance than the mouse across the reported Fitts’ law measures. Mean throughput was 0.35 bits/s for the BCI and 6.03 bits/s for the mouse in the 1D tests, and 0.43 bits/s for the BCI and 5.17 bits/s for the mouse in the 2D tests. Despite the BCI’s low performance and although the present experiments involved non-disabled participants, the findings, considered alongside prior literature on Brainfingers and non-invasive BCIs for computer access, suggest that the device may still have assistive technology value for users with severe motor impairments.
- 3 April 2026
- Published by MDPI AG in Preprints.org
Open AccessComparison of Point-and-Click Performance Between the Brainfingers BCI and the Mouse
This study quantitatively evaluates the performance of a non-invasive hybrid brain–computer interface (BCI) compared to a conventional mouse in pointing (point-and-click) tasks. A commercial wearable BCI (Brainfingers), based on electromyography (EMG) and electrooculography (EOG) signals with low-level electroencephalography (EEG) components, was assessed against a Microsoft Optical Mouse using ISO/TS 9241-411-based one-dimensional (1D) and two-dimensional (2D) target acquisition tasks. Pointer coordinates were recorded and analyzed using Fitts’ law metrics. A total of 48 non-disabled participants completed the experiments. The results reveal significant performance differences between the two input devices. The BCI device exhibits substantially lower performance than the mouse across the reported Fitts’ law measures. Mean throughput was 0.35 bits/s for the BCI and 6.03 bits/s for the mouse in the 1D tests, and 0.43 bits/s for the BCI and 5.17 bits/s for the mouse in the 2D tests. Despite the BCI’s low performance and although the present experiments involved non-disabled participants, the findings, considered alongside prior literature on Brainfingers and non-invasive BCIs for computer access, suggest that the device may still have assistive technology value for users with severe motor impairments.
- Open Access
- 3 March 2025
- Published by MDPI AG in Technologies
- Vol. 13 (3) , 99
Hand Dexterity Evaluation Grounded on Cursor Trajectory Investigation in Children with ADHD Using a Mouse and a Joystick
This study investigates disparities in upper limb motor skills between children with and without Attention Deficit Hyperactivity Disorder (ADHD), employing one-dimensional (1D) and two-dimensional (2D) point-and-click experiments using a mouse and a joystick and introducing one new metric for mouse cursor trajectory analysis. The participant pool comprised 46 children with combined type ADHD and an equivalent number of children without ADHD. The Input Device Evaluation Application (IDEA) system monitored the mouse pointer’s trajectory. Ten trajectory parameters were computed, including Index of Difficulty, Movement Time, Throughput, Missed Clicks, Target Re-Entry, Task Axis Crossing, Movement Direction Change, Movement Variability, Movement Error, Movement Offset, and Sample Entropy. The 2D joystick experiment trajectory parameters analysis conducted using a hierarchical logistic regression model achieved a 78% success rate in identifying children with ADHD. This research sheds light on the motor skill differences associated with ADHD in the context of computer-based tasks, providing valuable insights into potential diagnostic applications and intervention strategies and introducing one new metric makes for a deeper cursor trajectory analysis.
- 3 March 2025
- Published by MDPI AG in Technologies
- Vol. 13 (3) , 99
Open AccessHand Dexterity Evaluation Grounded on Cursor Trajectory Investigation in Children with ADHD Using a Mouse and a Joystick
This study investigates disparities in upper limb motor skills between children with and without Attention Deficit Hyperactivity Disorder (ADHD), employing one-dimensional (1D) and two-dimensional (2D) point-and-click experiments using a mouse and a joystick and introducing one new metric for mouse cursor trajectory analysis. The participant pool comprised 46 children with combined type ADHD and an equivalent number of children without ADHD. The Input Device Evaluation Application (IDEA) system monitored the mouse pointer’s trajectory. Ten trajectory parameters were computed, including Index of Difficulty, Movement Time, Throughput, Missed Clicks, Target Re-Entry, Task Axis Crossing, Movement Direction Change, Movement Variability, Movement Error, Movement Offset, and Sample Entropy. The 2D joystick experiment trajectory parameters analysis conducted using a hierarchical logistic regression model achieved a 78% success rate in identifying children with ADHD. This research sheds light on the motor skill differences associated with ADHD in the context of computer-based tasks, providing valuable insights into potential diagnostic applications and intervention strategies and introducing one new metric makes for a deeper cursor trajectory analysis.
- 20 April 2020
- Published by Springer Nature in Universal Access in the Information Society
- Vol. 20 (2) , 321-331
Hand dexterity assessment based on mouse pointer trajectory measurements in children with learning disabilities
- 20 April 2020
- Published by Springer Nature in Universal Access in the Information Society
- Vol. 20 (2) , 321-331
Hand dexterity assessment based on mouse pointer trajectory measurements in children with learning disabilities
- Open Access
- 27 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 28999-29013
Upper Limb Motor Skills Performance Evaluation Based on Point-and-Click Cursor Trajectory Analysis: Application in Early Multiple Sclerosis Detection
We present an enhanced version of the Input Device Evaluation Application (IDEA) system as an objective method for evaluating upper limb motor skills performance. By introducing three new metrics for mouse cursor trajectory analysis, along with the application of the two-dimensional (2D) experiment in the case of Multiple Sclerosis (MS), we examine the sensitivity of the IDEA system for differentiating patients with early-stage MS and healthy participants. The IDEA system calculates multiple kinematic metrics for point-and-click tasks: Movement Time, Index of Difficulty, Effective Target Width, Effective Index of Difficulty, Throughput, Missed Clicks, Target Re-entry, Task Axis Crossing, Movement Direction Change, Orthogonal Direction Change, Movement Variability, Movement Error, Movement Offset, Mean Velocity, Velocity Peaks and Maximum/Mean Velocity Ratio. The results reveal that the IDEA system sensitivity has been improved in comparison to previous studies, and is high enough to detect the presence of early-stage MS with a 70.9% success rate in the 2D experiment.
- 27 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 28999-29013
Open AccessUpper Limb Motor Skills Performance Evaluation Based on Point-and-Click Cursor Trajectory Analysis: Application in Early Multiple Sclerosis Detection
We present an enhanced version of the Input Device Evaluation Application (IDEA) system as an objective method for evaluating upper limb motor skills performance. By introducing three new metrics for mouse cursor trajectory analysis, along with the application of the two-dimensional (2D) experiment in the case of Multiple Sclerosis (MS), we examine the sensitivity of the IDEA system for differentiating patients with early-stage MS and healthy participants. The IDEA system calculates multiple kinematic metrics for point-and-click tasks: Movement Time, Index of Difficulty, Effective Target Width, Effective Index of Difficulty, Throughput, Missed Clicks, Target Re-entry, Task Axis Crossing, Movement Direction Change, Orthogonal Direction Change, Movement Variability, Movement Error, Movement Offset, Mean Velocity, Velocity Peaks and Maximum/Mean Velocity Ratio. The results reveal that the IDEA system sensitivity has been improved in comparison to previous studies, and is high enough to detect the presence of early-stage MS with a 70.9% success rate in the 2D experiment.
- 5 August 2016
- Published by Springer Nature in Multimedia Tools and Applications
- Vol. 76 (4) , 5347-5366
A methodological approach for designing and developing web-based inventories of mobile Assistive Technology applications
- 5 August 2016
- Published by Springer Nature in Multimedia Tools and Applications
- Vol. 76 (4) , 5347-5366
A methodological approach for designing and developing web-based inventories of mobile Assistive Technology applications
- 6 July 2016
- Published by Springer Nature in Lecture Notes in Computer Science
- p. 409-416
HERMOPHILOS: A Web-Based Information System for the Workflow Management and Delivery of Accessible eTextbooks
In this work we present the functional specifications, architecture and implementation of the HERMOPHILOS web-based system developed to auto-mate and accelerate the accessible eTextbooks’ production, workflow management, and delivery in an a higher education environment. We describe the redesign of the relative manual procedures and we show how HERMOPHILOS makes things easier and faster for the print-disabled students, as well as for the personnel involved. The web services of HERMOPHILOS include user sign up, user authentication, user rights management, students’ accessible textbooks re-quests, digital textbook requests to publishers, requests’ progress monitoring, original digital textbook copy submission, scanning, OCR, version and archive management, copyright protection, distribution, and digital content usage statistics. Implementation specifications included support for all browsers, operating systems, and mobile devices, accessible user interfaces (WCAG 2.0 AA), and advanced encryption and security policies. The HERMOPHILOS system sup-ports multiple formats for eTextbooks: plain text (.txt), rich text (.rtf), accessible markup (.xml, .xhtml, and .html), large print (.doc), audio books (.mp3), DAISY 2&3 (text only or full text - full audio), Braille (.brf or .brl), MS-Word (.docx), portable document format (.pdf) and LaTex (.tex). Paperwork was dramatically reduced, and the need for students’ visits to the accessibility office was eliminated. Τhe results show that, compared to the traditional procedure, the HERMOPHILOS workflow management system reduced the overall production and delivery time by 47 %.
- 6 July 2016
- Published by Springer Nature in Lecture Notes in Computer Science
- p. 409-416
HERMOPHILOS: A Web-Based Information System for the Workflow Management and Delivery of Accessible eTextbooks
In this work we present the functional specifications, architecture and implementation of the HERMOPHILOS web-based system developed to auto-mate and accelerate the accessible eTextbooks’ production, workflow management, and delivery in an a higher education environment. We describe the redesign of the relative manual procedures and we show how HERMOPHILOS makes things easier and faster for the print-disabled students, as well as for the personnel involved. The web services of HERMOPHILOS include user sign up, user authentication, user rights management, students’ accessible textbooks re-quests, digital textbook requests to publishers, requests’ progress monitoring, original digital textbook copy submission, scanning, OCR, version and archive management, copyright protection, distribution, and digital content usage statistics. Implementation specifications included support for all browsers, operating systems, and mobile devices, accessible user interfaces (WCAG 2.0 AA), and advanced encryption and security policies. The HERMOPHILOS system sup-ports multiple formats for eTextbooks: plain text (.txt), rich text (.rtf), accessible markup (.xml, .xhtml, and .html), large print (.doc), audio books (.mp3), DAISY 2&3 (text only or full text - full audio), Braille (.brf or .brl), MS-Word (.docx), portable document format (.pdf) and LaTex (.tex). Paperwork was dramatically reduced, and the need for students’ visits to the accessibility office was eliminated. Τhe results show that, compared to the traditional procedure, the HERMOPHILOS workflow management system reduced the overall production and delivery time by 47 %.
- 17 February 2016
- Published by IGI Global Scientific Publishing
- p. 680-727
Augmentative and Alternative Communication Systems for the Motor Disabled
This chapter discusses Augmentative and Alternative Communication (AAC) for individuals with motor disabilities. Motor disabilities do not only affect movement, but very often also affect speech. In these cases where voice is very weak, speech is unintelligible, or motor problems in the human speech production systems do not allow a person to speak, AAC is introduced. Aided and unaided communication is explained, and low and high tech AAC examples are illustrated. The ITHACA framework for building AAC applications is used as a paradigm in order to highlight the AAC software lifecycle. The same framework is also used to highlight AAC software design issues concerning component-based development (the open source model and the Design for All principles). Key features of an AAC application like virtual keyboards, scanning techniques, symbol dashboards, symbolic communication systems, message editors, symbol translation, word prediction, text to speech, and remote communication are presented. Finally, practical hints for choosing an AAC system are given and a case study of informally evaluating is cited.
- 17 February 2016
- Published by IGI Global Scientific Publishing
- p. 680-727
Augmentative and Alternative Communication Systems for the Motor Disabled
This chapter discusses Augmentative and Alternative Communication (AAC) for individuals with motor disabilities. Motor disabilities do not only affect movement, but very often also affect speech. In these cases where voice is very weak, speech is unintelligible, or motor problems in the human speech production systems do not allow a person to speak, AAC is introduced. Aided and unaided communication is explained, and low and high tech AAC examples are illustrated. The ITHACA framework for building AAC applications is used as a paradigm in order to highlight the AAC software lifecycle. The same framework is also used to highlight AAC software design issues concerning component-based development (the open source model and the Design for All principles). Key features of an AAC application like virtual keyboards, scanning techniques, symbol dashboards, symbolic communication systems, message editors, symbol translation, word prediction, text to speech, and remote communication are presented. Finally, practical hints for choosing an AAC system are given and a case study of informally evaluating is cited.
- 1 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1658-1664
Upper Limb Motor Skills Evaluation in Patients with Early Multiple Sclerosis Using the IDEA System
Upper limb functionality is an integral part of everyday interaction with the environment right from the very first minutes of human life. ϵhis paper investigates the experimental application of the IDEA (Input Device Evaluation Application) system on patients with multiple sclerosis at an early stage and without clinically overt motor deficits, in order to assess their upper limbs' motor skills. The objective of the current study is to test the sensitivity and reliability of the IDEA system regarding the evaluation of multiple kinetic parameters of upper limbs. 29 patients who were hospitalized in the Demyelinating Diseases Section of Eginition Hospital's Neurological Clinic and 25 healthy participated in the experiments. Data derived from the experiment are complemented with demographics. The acquired results analysis reveals that the IDEA system sensitivity is high enough to predict the presence of early upper limb multiple sclerosis with a 69.1% success rate.
- 1 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1658-1664
Upper Limb Motor Skills Evaluation in Patients with Early Multiple Sclerosis Using the IDEA System
Upper limb functionality is an integral part of everyday interaction with the environment right from the very first minutes of human life. ϵhis paper investigates the experimental application of the IDEA (Input Device Evaluation Application) system on patients with multiple sclerosis at an early stage and without clinically overt motor deficits, in order to assess their upper limbs' motor skills. The objective of the current study is to test the sensitivity and reliability of the IDEA system regarding the evaluation of multiple kinetic parameters of upper limbs. 29 patients who were hospitalized in the Demyelinating Diseases Section of Eginition Hospital's Neurological Clinic and 25 healthy participated in the experiments. Data derived from the experiment are complemented with demographics. The acquired results analysis reveals that the IDEA system sensitivity is high enough to predict the presence of early upper limb multiple sclerosis with a 69.1% success rate.
- 28 October 2015
- Published by Springer Nature in Lecture Notes in Computer Science
- p. 519-527
The mATHENA Inventory for Free Mobile Assistive Technology Applications
The entry of smartphones and tablets in the market yields new opportunities in the domain of Assistive Technology (AT) for persons with disabilities. The search process for mobile AT applications that fulfill specific user needs is not an easy task for the end-users, their facilitators as well as the professionals in the area of rehabilitation. Even, when they finally find what they are looking for, a number of questions are raised relative to the reliability, stability, compatibility and functionality of the AT applications. These questions can be answered safely only by a team of AT experts. In this work we present the methodological approach for the design and development of the mATHENA web-based inventory, which aims to make the search and selection of free mobile AT applications simple and sound. This methodology is based on the consistent and well-documented presentation of the information for each mobile AT application, after it is tested in an AT lab. mATHENA offers social interaction services for its diverse target groups. Moreover, we present the advantages of mATHENA compared with the functionalities of six other inventories for AT applications. Currently, mATHENA includes 420 free mobile AT applications, carefully selected among a total of 1,100.
- 28 October 2015
- Published by Springer Nature in Lecture Notes in Computer Science
- p. 519-527
The mATHENA Inventory for Free Mobile Assistive Technology Applications
The entry of smartphones and tablets in the market yields new opportunities in the domain of Assistive Technology (AT) for persons with disabilities. The search process for mobile AT applications that fulfill specific user needs is not an easy task for the end-users, their facilitators as well as the professionals in the area of rehabilitation. Even, when they finally find what they are looking for, a number of questions are raised relative to the reliability, stability, compatibility and functionality of the AT applications. These questions can be answered safely only by a team of AT experts. In this work we present the methodological approach for the design and development of the mATHENA web-based inventory, which aims to make the search and selection of free mobile AT applications simple and sound. This methodology is based on the consistent and well-documented presentation of the information for each mobile AT application, after it is tested in an AT lab. mATHENA offers social interaction services for its diverse target groups. Moreover, we present the advantages of mATHENA compared with the functionalities of six other inventories for AT applications. Currently, mATHENA includes 420 free mobile AT applications, carefully selected among a total of 1,100.