Mirian Cristina Santos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mirian Cristina Santos has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Joaquim Araújo Nobrega
Universidade Federal de São Carlos
9 shared publications - George L. Donati
Laboratory of Inorganic and Nuclear Chemistry, Wadsworth Center, New York State Department of Health, Albany, NY 12237, USA
6 shared publications - Daniel Araujo Goncalves
Faculty of Exact Sciences and Technology, Federal University of Grande Dourados, Dourados, Brazil
4 shared publications Solange Cadore
4 shared publications- Ana Rita Araujo Nogueira
Embrapa Pecuária Sudeste, São Carlos, Brazil
3 shared publications Bradley T. Jones
Department of Chemistry, Wake Forest University, Salem Hall, Box 7486, Winston-Salem, NC 27109, USA
2 shared publications
Latest Publications
- 11 March 2019
- Published by Springer Nature in Journal of Polymer Research
- Vol. 26 (4) , 1-12
PVDF nanofibers obtained by solution blow spinning with use of a commercial airbrush
- 11 March 2019
- Published by Springer Nature in Journal of Polymer Research
- Vol. 26 (4) , 1-12
PVDF nanofibers obtained by solution blow spinning with use of a commercial airbrush
- 9 November 2017
- Published by Bentham Science Publishers Ltd. in Current Analytical Chemistry
- Vol. 13 (6) , 474-479
Trace Element Analysis of Fusel Oil by Microwave-Induced Plasma Optical Emission Spectrometry
Background: Fusel oil is a mixture of higher alcohols produced as a minor fraction of the fermentation-distillation process in sugar and ethanol industries. It can be used as a fixating agent in cosmetics products, as solvent in the food industry, or recycled as fertilizer. Considering the effects of toxic elements contamination on the quality and safety of these products, and on the environment, an efficient method for elemental fusel oil analysis may find applications in many fields. In this work, we evaluate the application of microwave-induced plasma optical emission spectrometry (MIP OES) for trace element determinations in the fusel oil matrix. Methods: Simple external calibration with standard solutions prepared in either water or 1-propanol is evaluated. Undiluted fusel oil, and 1-propanol solutions containing 5 or 50% v v-1 sample matrix are analyzed. The introduction of air into the plasma prevented potential carbon deposition on the torch and the optics, and contributed to minimizing background signals. Results: No matrix effects were observed for calibration with 1-propanol solutions even for determinations in the undiluted sample (recoveries between 90-109% for a 1.0 mg L-1 spiking level). The MIP stability requires no sample preparation, which allows for lower limits of detection (LODs) and higher sample throughput. The LODs for Cd, Cr, Cu, Ni and Pb in 1-propanol are 0.03, 0.009, 0.01, 0.007 and 0.04 mg L-1, respectively. Conclusion: The MIP OES procedure described here is a simple, accurate and precise approach to trace element analysis of fusel oil.
- 9 November 2017
- Published by Bentham Science Publishers Ltd. in Current Analytical Chemistry
- Vol. 13 (6) , 474-479
Trace Element Analysis of Fusel Oil by Microwave-Induced Plasma Optical Emission Spectrometry
Background: Fusel oil is a mixture of higher alcohols produced as a minor fraction of the fermentation-distillation process in sugar and ethanol industries. It can be used as a fixating agent in cosmetics products, as solvent in the food industry, or recycled as fertilizer. Considering the effects of toxic elements contamination on the quality and safety of these products, and on the environment, an efficient method for elemental fusel oil analysis may find applications in many fields. In this work, we evaluate the application of microwave-induced plasma optical emission spectrometry (MIP OES) for trace element determinations in the fusel oil matrix. Methods: Simple external calibration with standard solutions prepared in either water or 1-propanol is evaluated. Undiluted fusel oil, and 1-propanol solutions containing 5 or 50% v v-1 sample matrix are analyzed. The introduction of air into the plasma prevented potential carbon deposition on the torch and the optics, and contributed to minimizing background signals. Results: No matrix effects were observed for calibration with 1-propanol solutions even for determinations in the undiluted sample (recoveries between 90-109% for a 1.0 mg L-1 spiking level). The MIP stability requires no sample preparation, which allows for lower limits of detection (LODs) and higher sample throughput. The LODs for Cd, Cr, Cu, Ni and Pb in 1-propanol are 0.03, 0.009, 0.01, 0.007 and 0.04 mg L-1, respectively. Conclusion: The MIP OES procedure described here is a simple, accurate and precise approach to trace element analysis of fusel oil.
- 16 January 2017
- Published by Springer Nature in Biological Trace Element Research
- Vol. 178 (2) , 228-234
Determination of Trace Elements in Cow Placenta by Tungsten Coil Atomic Emission Spectrometry
Tungsten coil atomic emission spectrometry (WCAES) is used to determine trace levels of Mn (403.1 nm) and Cr (425.5 nm) in cow placenta. All samples were collected in Ilha Solteira, SP, Brazil. The instrumental setup is based on a tungsten filament extracted from 150 W, 15 V microscope light bulbs, a solid state power supply, fused silica lens, crossed Czerny-Turner spectrograph, and a thermoelectrically cooled charge-coupled device detector. The limits of detection (LOD) and quantification (LOQ) for Cr are 2 and 8 μg L−1, and 20 and 60 μg L−1 for Mn, respectively. Recoveries for 0.30 mg L−1 spikes of each analyte were in the range 93.0–103.0%, and relative standard deviation (RSD) was between 6.50 and 7.20% for both elements. Placenta samples were microwave-assisted digested with diluted HNO3 and H2O2 and analyzed by WCAES. The results for Cr and Mn were compared with values obtained by tandem inductively coupled plasma mass spectrometry (ICP-MS/MS). No statistically significant difference was observed between the different methods by applying a paired t test at a 95% confidence level. The average concentrations of Cr and Mn in the placentas evaluated were 0.95 ± 0.22 and 2.64 ± 0.39 μg g−1, respectively. By using a short integration time, LODs for Cr and Mn were lower than values reported by recent works using a similar WCAES system.
- 16 January 2017
- Published by Springer Nature in Biological Trace Element Research
- Vol. 178 (2) , 228-234
Determination of Trace Elements in Cow Placenta by Tungsten Coil Atomic Emission Spectrometry
Tungsten coil atomic emission spectrometry (WCAES) is used to determine trace levels of Mn (403.1 nm) and Cr (425.5 nm) in cow placenta. All samples were collected in Ilha Solteira, SP, Brazil. The instrumental setup is based on a tungsten filament extracted from 150 W, 15 V microscope light bulbs, a solid state power supply, fused silica lens, crossed Czerny-Turner spectrograph, and a thermoelectrically cooled charge-coupled device detector. The limits of detection (LOD) and quantification (LOQ) for Cr are 2 and 8 μg L−1, and 20 and 60 μg L−1 for Mn, respectively. Recoveries for 0.30 mg L−1 spikes of each analyte were in the range 93.0–103.0%, and relative standard deviation (RSD) was between 6.50 and 7.20% for both elements. Placenta samples were microwave-assisted digested with diluted HNO3 and H2O2 and analyzed by WCAES. The results for Cr and Mn were compared with values obtained by tandem inductively coupled plasma mass spectrometry (ICP-MS/MS). No statistically significant difference was observed between the different methods by applying a paired t test at a 95% confidence level. The average concentrations of Cr and Mn in the placentas evaluated were 0.95 ± 0.22 and 2.64 ± 0.39 μg g−1, respectively. By using a short integration time, LODs for Cr and Mn were lower than values reported by recent works using a similar WCAES system.
- 1 February 2016
- Published by Elsevier in Analytica Chimica Acta
- Vol. 909, 24-29
Standard dilution analysis of beverages by microwave-induced plasma optical emission spectrometry
- 1 February 2016
- Published by Elsevier in Analytica Chimica Acta
- Vol. 909, 24-29
Standard dilution analysis of beverages by microwave-induced plasma optical emission spectrometry
- 9 April 2015
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 30 (6) , 1395-1399
Direct determination of chromium in empty medicine capsules by tungsten coil atomic emission spectrometry
Trace levels of Cr in empty medicine capsules determined in less than 12 min per sample (LOD = 0.4 µg g −1 ).
- 9 April 2015
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 30 (6) , 1395-1399
Direct determination of chromium in empty medicine capsules by tungsten coil atomic emission spectrometry
Trace levels of Cr in empty medicine capsules determined in less than 12 min per sample (LOD = 0.4 µg g −1 ).
- 10 May 2013
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 28 (8) , 1303-1310
Evaluation of sample preparation procedures and krypton as an interference standard probe for arsenic speciation by HPLC-ICP-QMS
Different conditions of extraction using water, a methanol–water mixture and nitric acid solutions were evaluated for speciation of As(III), As(V), DMA and MMA in plant samples that previously received As(V) after being sown and emergence was investigated. Microwave-assisted extraction (MAE) using diluted nitric acid solutions was also performed for arsenic extraction from chicken feed samples. The separation and determination of arsenic species were performed using HPLC-ICP-MS. The interference standard method (IFS) using 83Kr+ as the IFS probe was employed to minimize spectral interferences caused by polyatomic species, such as 40Ar35Cl+. The extraction procedures tested presented adequate extraction efficiencies (90%), and the four arsenic species evaluated were found in plant samples. Extractions with diluted nitric acid solution at 90 °C were the most efficient strategy, with quantitative recoveries for all four As species in plant tissues. On the other hand, the methanol–water mixture was the solvent with the lowest extraction efficiency (50–60%). For chicken feed samples, MAE at 100 °C for 30 min resulted in an extraction efficiency of 97% and only As(V) was found, without any species interconversion. The IFS method contributed to improving precision and limits of detection and quantification for all tested extraction procedures. Significant improvements on accuracy were obtained by applying the IFS method and recoveries between 77 and 94%, and 82 and 93% were obtained for plant extracts and chicken feed samples, respectively.
- 10 May 2013
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 28 (8) , 1303-1310
Evaluation of sample preparation procedures and krypton as an interference standard probe for arsenic speciation by HPLC-ICP-QMS
Different conditions of extraction using water, a methanol–water mixture and nitric acid solutions were evaluated for speciation of As(III), As(V), DMA and MMA in plant samples that previously received As(V) after being sown and emergence was investigated. Microwave-assisted extraction (MAE) using diluted nitric acid solutions was also performed for arsenic extraction from chicken feed samples. The separation and determination of arsenic species were performed using HPLC-ICP-MS. The interference standard method (IFS) using 83Kr+ as the IFS probe was employed to minimize spectral interferences caused by polyatomic species, such as 40Ar35Cl+. The extraction procedures tested presented adequate extraction efficiencies (90%), and the four arsenic species evaluated were found in plant samples. Extractions with diluted nitric acid solution at 90 °C were the most efficient strategy, with quantitative recoveries for all four As species in plant tissues. On the other hand, the methanol–water mixture was the solvent with the lowest extraction efficiency (50–60%). For chicken feed samples, MAE at 100 °C for 30 min resulted in an extraction efficiency of 97% and only As(V) was found, without any species interconversion. The IFS method contributed to improving precision and limits of detection and quantification for all tested extraction procedures. Significant improvements on accuracy were obtained by applying the IFS method and recoveries between 77 and 94%, and 82 and 93% were obtained for plant extracts and chicken feed samples, respectively.
- 10 February 2009
- Published by Springer Nature in Food Analytical Methods
- Vol. 3 (1) , 31-35
Determination of Selenium in Liquid Dietetic Sweeteners by GF AAS
- 10 February 2009
- Published by Springer Nature in Food Analytical Methods
- Vol. 3 (1) , 31-35
Determination of Selenium in Liquid Dietetic Sweeteners by GF AAS