Galina Filatova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Galina Filatova has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Andrey Yablokov
ISPU, Ivanovo, Russian Federation
4 shared publications - Vladimir Dmitrievich Lebedev
Ivanovo State Power Engineering University, 153003 Ivanovo, Russia
4 shared publications - Alexander Timofeev
Plekhanov Russian University of Economics
2 shared publications Andrey Yablokov
Electric Power Systems Automatic Control Department, Ivanovo State Power Engeneering University (ISPEU), Ivanovo, Russia
2 shared publicationsV. Shuin
Department of Electric Power System Automatic Control, Ivanovo State Power Engineering University, Ivanovo, Russia
2 shared publications- Aleksandr Bulashov
TISBI, Kazan, Russian Federation
1 shared publication
Latest Publications
- Open Access
- 6 May 2025
- Published by Association for Computing Machinery (ACM)
- p. 670-671
Poster Abstract: Autonomous AI-Driven Grid Protection: Sub-Cycle Fault Response via NPU-Optimized Neural Networks
- 6 May 2025
- Published by Association for Computing Machinery (ACM)
- p. 670-671
Open AccessPoster Abstract: Autonomous AI-Driven Grid Protection: Sub-Cycle Fault Response via NPU-Optimized Neural Networks
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3, 433-437
Research of Fault Location Algorithm for Data Metering System Based on Digital Transformers
The usage of the innovative primary converters requires the development of new methods and algorithms of relay protection and automation, including the fault location algorithms taking into account the features of these primary converters and digital current and voltage transformers at all. The developed algorithm is applied to conduct the estimation of the distance to a fault (short circuit point) using one-sided measurement of emergency mode parameters. The authors provide the results of the research on the influence of the distorting factors on the fault location accuracy conducted on the simulation models. The special program in MATLAB was developed for the research of numerous distorting factors and conducting a large number of experiments.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3, 433-437
Research of Fault Location Algorithm for Data Metering System Based on Digital Transformers
The usage of the innovative primary converters requires the development of new methods and algorithms of relay protection and automation, including the fault location algorithms taking into account the features of these primary converters and digital current and voltage transformers at all. The developed algorithm is applied to conduct the estimation of the distance to a fault (short circuit point) using one-sided measurement of emergency mode parameters. The authors provide the results of the research on the influence of the distorting factors on the fault location accuracy conducted on the simulation models. The special program in MATLAB was developed for the research of numerous distorting factors and conducting a large number of experiments.
- Open Access
- 1 January 2018
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2018 (1)
Increase of Accuracy of the Fault Location Methods for Overhead Electrical Power Lines
The high‐voltage power lines are quite often damaged parts of the energy system. Line outage is always accompanied by undersupply of energy and decrease of reliability, cost, and quality of electric supply. That is why one of the important tasks of line maintenance is quick looking for location of the damage and organization of the rehabilitation. The main part of this work includes development and research of the methods and algorithms for fault location based on one‐sided measurement and the ways to increase their accuracy. This type of measurement uses signals from digital current and voltage transformers as input. The influence of the basic distorting factors on the accuracy of the fault location determination methods is also considered.
- 1 January 2018
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2018 (1)
Open AccessIncrease of Accuracy of the Fault Location Methods for Overhead Electrical Power Lines
The high‐voltage power lines are quite often damaged parts of the energy system. Line outage is always accompanied by undersupply of energy and decrease of reliability, cost, and quality of electric supply. That is why one of the important tasks of line maintenance is quick looking for location of the damage and organization of the rehabilitation. The main part of this work includes development and research of the methods and algorithms for fault location based on one‐sided measurement and the ways to increase their accuracy. This type of measurement uses signals from digital current and voltage transformers as input. The influence of the basic distorting factors on the accuracy of the fault location determination methods is also considered.
- Open Access
- 12 December 2017
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 141, 01058
Using of non-traditional current and voltage sensors for the fault location
The article describes the possibilities of using the non-traditional current and voltage sensors to solve the problem of fault location in terms of digital transformers developed at the Ivanovo State Power Engineering University (ISPEU). Frequency and metrological characteristics of current and voltage sensors are given.
- 12 December 2017
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 141, 01058
Open AccessUsing of non-traditional current and voltage sensors for the fault location
The article describes the possibilities of using the non-traditional current and voltage sensors to solve the problem of fault location in terms of digital transformers developed at the Ivanovo State Power Engineering University (ISPEU). Frequency and metrological characteristics of current and voltage sensors are given.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Comparison of electrical variables of transient process for earth-to ground fault location in medium voltage cable networks
Early detection of faulty cable line with single-phase earth fault (SPEF) and SPEF location in the cable line is extremely important for timely fault elimination and restoration of normal power supply. Up to now, there is no effective method for a distant SPEF location in medium voltage cable lines at process voltage. Electrical data of transient processes at insulation damage can be used for single-phase fault location including self-clearing. The best opportunity for study of electromagnetic transients at SPEF in medium-voltage networks and identifying data, which can be used for a distant SPEF location, is a combination of analysis based on the simplified models of electrical networks and computer simulation. The most efficient algorithm for SPEF location can be obtained by measuring the transient voltage of the faulty phase and derivative di0(t)/dt at moments corresponding to i0(t) crossing the zero value.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Comparison of electrical variables of transient process for earth-to ground fault location in medium voltage cable networks
Early detection of faulty cable line with single-phase earth fault (SPEF) and SPEF location in the cable line is extremely important for timely fault elimination and restoration of normal power supply. Up to now, there is no effective method for a distant SPEF location in medium voltage cable lines at process voltage. Electrical data of transient processes at insulation damage can be used for single-phase fault location including self-clearing. The best opportunity for study of electromagnetic transients at SPEF in medium-voltage networks and identifying data, which can be used for a distant SPEF location, is a combination of analysis based on the simplified models of electrical networks and computer simulation. The most efficient algorithm for SPEF location can be obtained by measuring the transient voltage of the faulty phase and derivative di0(t)/dt at moments corresponding to i0(t) crossing the zero value.
- 1 January 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Study of possibility of digital voltage transformers usage in fault location determination
Innovative development of electric power systems is aimed at creating active-adaptive networks. Control of active-adaptive networks is based on usage of primary data measured at voltage and current transformers. In particular, the voltage transformers can be a source of information for devices determining fault location. The problem of fault location (FL) has always been and remains relevant because its solution may improve reliability of power supply. Overhead and cable high voltage power lines are most often-damageable elements of the electric power system. Power line cut-off is always accompanied by power undersupply or reduction of its reliability and quality. The paper investigates possibility of using transient voltage parameters obtained by digital voltage transformers for the FL on the cable lines.
- 1 January 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Study of possibility of digital voltage transformers usage in fault location determination
Innovative development of electric power systems is aimed at creating active-adaptive networks. Control of active-adaptive networks is based on usage of primary data measured at voltage and current transformers. In particular, the voltage transformers can be a source of information for devices determining fault location. The problem of fault location (FL) has always been and remains relevant because its solution may improve reliability of power supply. Overhead and cable high voltage power lines are most often-damageable elements of the electric power system. Power line cut-off is always accompanied by power undersupply or reduction of its reliability and quality. The paper investigates possibility of using transient voltage parameters obtained by digital voltage transformers for the FL on the cable lines.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Modeling of measuring current and voltage transformers in dynamic modes
Most of the works devoted to the study of measuring current and voltage transformers are focused on defining the characteristics of transformers in steady-state conditions to determine whether the transformers satisfy the metrological requirements. Such studies are often carried out using a chain of equivalent circuits or on the basis of field calculation methods. Field calculations methods definitely allow more precisely measuring the leakage field and the distribution of magnetic flux in the magnetic circuit. The study of transformers in dynamic modes is also of much interest. Nonlinearity of the core magnetization of measuring transformers leads to the need to create mathematical models that contain not only a model of the transformer itself, but also the model of circuits connected to it. In particular, of practical interest is the study of the stability of the voltage transformer to ferroresonance phenomena, when the transformer resonates with elements of the primary network connected to it. Thus, it is necessary to develop a mathematical tool allowing to create field models of instrument transformers connected to the primary and secondary circuits allow modeling not only steady modes, but transients ones as well. Problem solving in this formulation became possible after emerging of powerful computers and development of software packages capable to integrate for solving the problems.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Modeling of measuring current and voltage transformers in dynamic modes
Most of the works devoted to the study of measuring current and voltage transformers are focused on defining the characteristics of transformers in steady-state conditions to determine whether the transformers satisfy the metrological requirements. Such studies are often carried out using a chain of equivalent circuits or on the basis of field calculation methods. Field calculations methods definitely allow more precisely measuring the leakage field and the distribution of magnetic flux in the magnetic circuit. The study of transformers in dynamic modes is also of much interest. Nonlinearity of the core magnetization of measuring transformers leads to the need to create mathematical models that contain not only a model of the transformer itself, but also the model of circuits connected to it. In particular, of practical interest is the study of the stability of the voltage transformer to ferroresonance phenomena, when the transformer resonates with elements of the primary network connected to it. Thus, it is necessary to develop a mathematical tool allowing to create field models of instrument transformers connected to the primary and secondary circuits allow modeling not only steady modes, but transients ones as well. Problem solving in this formulation became possible after emerging of powerful computers and development of software packages capable to integrate for solving the problems.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Study and modeling of zero sequence current sensors in the transient modes in Matlab
Solving the problems associated with the improvement of single-phase earth fault (SPEF) protection devices and SPEF location determination devices on the lines is of practical interest to study the operation of cable current transformers and other sensors in the transients states. The paper discusses the principles of constructing models of current sensors in the environment Matlab.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Study and modeling of zero sequence current sensors in the transient modes in Matlab
Solving the problems associated with the improvement of single-phase earth fault (SPEF) protection devices and SPEF location determination devices on the lines is of practical interest to study the operation of cable current transformers and other sensors in the transients states. The paper discusses the principles of constructing models of current sensors in the environment Matlab.