Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yinxiao Zhu has a total of 95 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Non-Intrusive Battery-Backed Grid-Forming Configuration for Grid-Following Photovoltaic Plants Retrofit

    by Fang Fang, Yinxiao Zhu, Yongheng Yang

    Existing grid-connected photovoltaic (PV) systems with grid-following (GFL) control rely on phase-locked loop (PLL)-based grid synchronization, which may become unstable under weak grid conditions. By contrast, grid-forming (GFM) retrofits are regarded as promising solutions for improving the stability of GFL-based PV integration. However, existing retrofit methods often require comprehensive replacement or substantial modification of the existing GFL controller or hardware, thereby increasing retrofit costs and maintenance complexity. To address these issues, a non-intrusive configuration with a battery-backed GFM branch comprising a charging rectifier and a GFM inverter is proposed for retrofitting implemented GFL PV power plants in this paper. With the proposed configuration, the existing GFL PV inverters retain their original hardware and GFL control. The charging rectifier branch absorbs surplus PV power from the PV inverter output, whereas the proposed battery-backed GFM branch is connected at the point of common coupling (PCC) to provide voltage- and frequency-forming supports. To utilize the available branch capacity under normal grid conditions, selected auxiliary functions, i.e., harmonic compensation and Volt–VAR support, are incorporated subject to the available inverter operating margin. The effectiveness of the proposed configuration and the corresponding control scheme is validated through different operating scenarios, including PV/load mismatch charging, nonlinear load harmonic compensation, reactive load Volt–VAR support, grid frequency and grid voltage disturbances under different grid strength conditions, and combined dynamic operating disturbances at weak grids.

  • Characterization Framework for Grid-Forming Control: Seen From the Perspective of AC Power Supplies

    by Hao Luo, Yinxiao Zhu, Yongheng Yang, Huanhai Xin, Nick Papanikolaou

    The rapid growth of renewable energy sources leads to an increasingly high penetration of power electronics converters in the grid. In this context, the grid-forming (GFM) control has been explored to establish a stable voltage reference for the grid with a high proportion of inverter-based resources (IBRs). Although specific requirements for GFM controls have been released, a unified and comprehensive benchmarking method is still missing. Thus, in this paper, a characterization framework is proposed, where the characteristics of the GFM control are extended seen from the perspective of AC power supplies, to assist the unification of GFM technologies. The proposed framework comprises key functions, test bench configuration, critical index selection, and comprehensive evaluation to characterize different GFM controls, namely, the droop, virtual synchronous generator, matching, and virtual oscillator controls. Based on the proposed framework, the performance of these GFM controls is characterized on a hardware-in-loop (HIL) platform. The results show that the distinguishable differences, including the rate of change of frequency (RoCoF), power overshoot, and voltage settling time, can be acquired from the proposed framework as key indices. Meanwhile, the proposed framework demonstrates robust extensibility, enabling a comprehensive evaluation of various GFM schemes based on information about the point of common coupling.


  • Six-Control Degree-of-Freedom Modulation Scheme for DAB DC–DC Converters to Enhance Efficiency With the Aid of Deep Reinforcement Learning

    by Zhichen Feng, Huiqing Wen, Xu Han, Guangyu Wang, Yinxiao Zhu, Jose Rodriguez

    The conversion efficiency of dual active bridge (DAB) converter could be improved by increasing the number of control degrees of freedom (DoF). A modulation with six control degrees of freedom (6-DoF) is proposed in this article to further improve the efficiency of DAB converters. First, frequency-domain analysis is used to directly derive the operating expressions of the converter, including the transmission power, inductor current, and root-mean-square (RMS) current. Then, a deep reinforcement learning (DRL) optimization scheme with 6-DoF (DRL-6DoF) is proposed. Specifically, the deep deterministic policy gradient (DDPG) algorithm is used for solving optimal solutions with the minimum power losses. The trained DDPG agent can output the optimal values of control variables under various operation conditions. With the proposed DRL-6DoF control scheme, the efficiency of the DAB converter is further improved because of the low RMS current and great ZVS performance. Especially under heavy load conditions, the efficiency is great improved because of the characteristic of variable switching frequency. Finally, the effectiveness of the proposed method is verified by experimental results on a built prototype.


  • Open Access

    Unit power rating balancing for differential-power-processing-based distributed photovoltaic systems

    by Jiahua Ni, Zhixing Zhao, Yinxiao Zhu

    Differential power processing (DPP) architectures are effective solutions for photovoltaic (PV) systems experiencing uncertainties in environmental conditions, such as non-uniform irradiation, which can significantly degrade electricity production efficiency and operating safety. Among the different architectures available, the PV-to-bus DPP configuration has shown excellent performances for control flexibility and galvanic isolation capability. However, recent control schemes for PV-to-bus architectures offer lower-than-desirable efficiency enhancements, such as those involving implementation complexities and unit power distributions. Hence, a unit power rating balancing (UPRB) scheme is proposed in this work to reconfigure the distribution of differential power among the unit converters with the aim of ensuring submodule-level optimization and enhanced performance of the entire PV system. The proposed UPRB scheme integrates perturbation-and-observation-based maximum power-point tracking units to maximize the energy harvested from PV modules, and the unit balance-point tracking unit is employed to determine the optimal string current reference directly for mitigating the unbalanced differential power in the DPP units. By suppressing the maximum processed power in each DPP unit, the capital cost and system size can be reduced. Simulation and experimental studies were conducted, whose evaluation results support the applicability of the proposed control scheme.


  • Open Access

    Review of Photovoltaic–Battery Energy Storage Systems for Grid-Forming Operation

    by Kai Yin, Yi Xiao, Xiaomeng Shen, Yinxiao Zhu, Yongheng Yang

    Coordinated control technology attracts increasing attention to the photovoltaic–battery energy storage (PV-BES) systems for the grid-forming (GFM) operation. However, there is an absence of a unified perspective that reviews the coordinated GFM control for PV-BES systems based on different system configurations. This paper aims to fill the gap by providing a comprehensive review of coordinated GFM control strategies for PV-BES, considering various system configurations. Typical configurations of PV-BES systems are explored, followed by a detailed discussion of conventional GFM control methods used in the PV-BES systems. Furthermore, coordinated GFM controls are analyzed in PV-BES systems based on different configurations, providing the common DC bus configuration as a widely adopted configuration due to its more control degrees of freedom and ease of expansion. Moreover, the mode division and switching coordinated control based on the system power is the most widely used. Furthermore, challenges in the coordinated GFM controls for the PV-BES system in future applications are briefed and emphasized before the conclusion.


  • Robust Design of Perturb & Observe Maximum Power Point Tracking for Photovoltaic Systems

    by Runze Lv, Yinxiao Zhu, Yongheng Yang

    The perturb & observe (P&O) maximum power point tracking (MPPT) is widely used in photovoltaic (PV) systems due to its simplicity and reliability. To optimize the performance, a tradeoff between static and dynamic efficiencies should be made. Yet, present design methods are not efficient enough for practical use. As for the prior-art calculation-based methods, they only focus on the problem of direction confusion under dynamic conditions, while the static efficiency will be low. Although the experience-based methods consider both static and dynamic efficiencies, they cannot give a clear result, and the parameters still need to be set in a trial-and-error process. As such, in this paper, an analytical model is established based on the operation principles to provide clear characteristics of key indices (i.e., static and dynamic efficiencies, and the requirement of the DC voltage range), and the impact of parameters on the efficiency is revealed. Subsequently, a robust design is proposed for the optimum design, which can set the key parameters, achieving relatively high tracking accuracy. Finally, simulations and experimental tests are performed, verifying the theoretical analysis and the effectiveness of the proposed design.


  • Deep Reinforcement Learning Assisted Hybrid Five-Variable Modulation Scheme for DAB Converters to Reduce RMS Current and Expand ZVS Operation

    by Zhichen Feng, Huiqing Wen, Xu Han, Qinglei Bu, Yinxiao Zhu, Guangyu Wang

    In order to enhance the conversion efficiency of dual-active-bridge converters, a hybrid five-variable (HFV) modulation strategy with the aid of deep reinforcement learning technique is proposed in this article. Specifically, deep deterministic policy gradient (DDPG) algorithm is employed to train the agent with the purpose of the lower root mean square (RMS) current and the zero voltage switching (ZVS) operation of all power switches under various conditions. Moreover, due to the complexity of HFV modulation with five control DoF, frequency-domain analysis is used to directly derive the operating expressions of the converter. Based on these, the trained DDPG agent can output the optimal values of control variables, which can lower the RMS current and achieve the widest ZVS operation with reduced computation burden. A thorough comparison among related works in terms of the RMS current and ZVS range was presented. Finally, the effectiveness of the proposed method is verified by experiments on a built prototype.