Zhi Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zhi Li has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Jordi Sort
Departament de Física, Universitat Autònoma de Barcelona, E-08193 Cerdanyola del Vallès, Spain
3 shared publications - Josep Nogues
Catalan Institute of Nanoscience and Nanotechnology (ICN2) CSIC and BIST Barcelona Spain
3 shared publications - Alejandro Gomez Roca
Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and BIST, Campus UAB, Bellaterra, 08193 Barcelona, Spain
2 shared publications - Borja Sepúlveda
Instituto de Microelectrónica de Barcelona (IMB-CNM, CSIC), Barcelona, 08193, Spain
2 shared publications - Carme Nogués
Departament de Biologia Cellular, Fisiologia i Immunologia, Universitat Autònoma de Barcelona, Barcelona, Spain
2 shared publications José Luis Tajada
2 shared publications
Latest Publications
- Open Access
- 24 April 2026
- Published by The Royal Society in Interface Focus
- Vol. 16 (1)
Stretchable and conductive PAAm@PPy hydrogels with low hysteresis for strain sensing
Conductive hydrogels are promising materials for soft strain sensing because they combine tissue-like mechanics with electrical functionality. However, many existing systems emphasize conductivity or sensitivity at the cost of mechanical reversibility, leading to pronounced hysteresis and limited cyclic stability. Here, we report a two-step fabrication strategy that decouples mechanical and electrical optimization. A highly entangled polyacrylamide (PAAm) hydrogel is first prepared as a mechanically reversible scaffold, followed by in situ polymerization of polypyrrole (PPy) to introduce conductivity, yielding a composite hydrogel (PAAm@PPy). The material exhibits soft-tissue-level stiffness (Young’s modulus of 75 kPa), high stretchability (strain at break of 246%) and low mechanical hysteresis (5.7% at 50% strain). The as-synthesized PAAm@PPy shows an apparent bulk conductivity of 0.094 S cm⁻¹ and a linear positive piezoresistive response with a gauge factor of 2.04 over 0–50% strain, together with stable cyclic sensing (500 cycles at 30% strain). A proof-of-concept finger-bending demonstration confirms its fast response and signal stability. This work establishes a conductive hydrogel design paradigm that prioritizes low hysteresis and cyclic stability through a decoupled two-step co-synthesis of highly entangled hydrogels and conductive polymer, enabling reliable strain sensing for soft electronic applications.
- 24 April 2026
- Published by The Royal Society in Interface Focus
- Vol. 16 (1)
Open AccessStretchable and conductive PAAm@PPy hydrogels with low hysteresis for strain sensing
Conductive hydrogels are promising materials for soft strain sensing because they combine tissue-like mechanics with electrical functionality. However, many existing systems emphasize conductivity or sensitivity at the cost of mechanical reversibility, leading to pronounced hysteresis and limited cyclic stability. Here, we report a two-step fabrication strategy that decouples mechanical and electrical optimization. A highly entangled polyacrylamide (PAAm) hydrogel is first prepared as a mechanically reversible scaffold, followed by in situ polymerization of polypyrrole (PPy) to introduce conductivity, yielding a composite hydrogel (PAAm@PPy). The material exhibits soft-tissue-level stiffness (Young’s modulus of 75 kPa), high stretchability (strain at break of 246%) and low mechanical hysteresis (5.7% at 50% strain). The as-synthesized PAAm@PPy shows an apparent bulk conductivity of 0.094 S cm⁻¹ and a linear positive piezoresistive response with a gauge factor of 2.04 over 0–50% strain, together with stable cyclic sensing (500 cycles at 30% strain). A proof-of-concept finger-bending demonstration confirms its fast response and signal stability. This work establishes a conductive hydrogel design paradigm that prioritizes low hysteresis and cyclic stability through a decoupled two-step co-synthesis of highly entangled hydrogels and conductive polymer, enabling reliable strain sensing for soft electronic applications.
- Open Access
- 5 December 2022
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 17 (3) , 1946-1958
Efficient Tumor Eradication at Ultralow Drug Concentration via Externally Controlled and Boosted Metallic Iron Magnetoplasmonic Nanocapsules
- 5 December 2022
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 17 (3) , 1946-1958
Open AccessEfficient Tumor Eradication at Ultralow Drug Concentration via Externally Controlled and Boosted Metallic Iron Magnetoplasmonic Nanocapsules
- 1 September 2018
- Published by Elsevier in Applied Materials Today
- Vol. 12, 430-440
Magnetically amplified photothermal therapies and multimodal imaging with magneto-plasmonic nanodomes
- 1 September 2018
- Published by Elsevier in Applied Materials Today
- Vol. 12, 430-440
Magnetically amplified photothermal therapies and multimodal imaging with magneto-plasmonic nanodomes
Simultaneous Local Heating/Thermometry Based on Plasmonic Magnetochromic Nanoheaters
A crucial challenge in nanotherapies is achieving accurate and real‐time control of the therapeutic action, which is particularly relevant in local thermal therapies to minimize healthy tissue damage and necrotic cell deaths. Here, a nanoheater/thermometry concept is presented based on magnetoplasmonic (Co/Au or Fe/Au) nanodomes that merge exceptionally efficient plasmonic heating and simultaneous highly sensitive detection of the temperature variations. The temperature detection is based on precise optical monitoring of the magnetic‐induced rotation of the nanodomes in solution. It is shown that the phase lag between the optical signal and the driving magnetic field can be used to detect viscosity variations around the nanodomes with unprecedented accuracy (detection limit 0.0016 mPa s, i.e., 60‐fold smaller than state‐of‐the‐art plasmonic nanorheometers). This feature is exploited to monitor the viscosity reduction induced by optical heating in real‐time, even in highly inhomogeneous cell dispersions. The magnetochromic nanoheater/thermometers show higher optical stability, much higher heating efficiency and similar temperature detection limits (0.05 °C) compared to state‐of‐the art luminescent nanothermometers. The technological interest is also boosted by the simpler and lower cost temperature detection system, and the cost effectiveness and scalability of the nanofabrication process, thereby highlighting the biomedical potential of this nanotechnology.
Simultaneous Local Heating/Thermometry Based on Plasmonic Magnetochromic Nanoheaters
A crucial challenge in nanotherapies is achieving accurate and real‐time control of the therapeutic action, which is particularly relevant in local thermal therapies to minimize healthy tissue damage and necrotic cell deaths. Here, a nanoheater/thermometry concept is presented based on magnetoplasmonic (Co/Au or Fe/Au) nanodomes that merge exceptionally efficient plasmonic heating and simultaneous highly sensitive detection of the temperature variations. The temperature detection is based on precise optical monitoring of the magnetic‐induced rotation of the nanodomes in solution. It is shown that the phase lag between the optical signal and the driving magnetic field can be used to detect viscosity variations around the nanodomes with unprecedented accuracy (detection limit 0.0016 mPa s, i.e., 60‐fold smaller than state‐of‐the‐art plasmonic nanorheometers). This feature is exploited to monitor the viscosity reduction induced by optical heating in real‐time, even in highly inhomogeneous cell dispersions. The magnetochromic nanoheater/thermometers show higher optical stability, much higher heating efficiency and similar temperature detection limits (0.05 °C) compared to state‐of‐the art luminescent nanothermometers. The technological interest is also boosted by the simpler and lower cost temperature detection system, and the cost effectiveness and scalability of the nanofabrication process, thereby highlighting the biomedical potential of this nanotechnology.