Fulgentius Ferryanto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Fulgentius Ferryanto has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Andi Isra Mahyuddin
Institut Teknologi Bandung
6 shared publications - Motomu Nakashima
Department of Systems and Control Engineering, Institute of Science Tokyo, Meguro, Japan
2 shared publications Sandro Mihradi
Mechanical Design Research Group
2 shared publications- Sandro Mihradi
Institut Teknologi Bandung
2 shared publications Tatacipta Dirgantara
Institut Teknologi Bandung
2 shared publicationsAchmad Widodo
State University of Surabaya
1 shared publication
Latest Publications
- 1 August 2026
- Published by IOP Publishing in Engineering Research Express
- Vol. 8 (16) , 165526
Design and experimental validation of ligament-mimetic compliant joints for 3D-printed prosthetic elbows
This study presents the design and experimental validation of a prosthetic elbow joint based on compliant mechanisms that mimic the function of elbow ligaments. The proposed design uses crossed flexural beams to enable two modes of motion—flexion–extension and pronation–supination—while reducing the need for discrete mechanical components. Eighteen flexural-beam configurations were evaluated for each motion mode by varying the number of flexural beam elements, beam width, beam thickness, and reinforcement topology. Finite element analysis was used to evaluate maximum equivalent stress, deformation response, and actuation force at maximum deformation. The results showed a nonlinear relationship between rotation angle and both maximum equivalent stress and required actuation force. The flexural-beam analysis also indicated that beam thickness strongly influenced joint stiffness, consistent with the cubic dependence of bending stiffness on thickness. For preliminary validation, six configurations were fabricated using fused deposition modeling (FDM) with PETG and experimentally tested. The highest agreement between experimental and finite element results was observed with R 2 = 0.924 . A Pareto-based multi-objective design selection method was then applied to identify the optimal configuration by minimizing equivalent stress while maintaining low actuation force. The selected mechanisms were integrated into a lightweight prototype measuring 87.1 mm in length and weighing 160 g. The prototype achieved the required range of motion for flexion–extension and pronation–supination. However, the 1 kg load-bearing requirement was only partially satisfied, as the device supported the load in full extension but could not maintain it at approximately 90 ∘ of flexion. Overall, this study establishes mechanics-based design guidelines for a flexible, compact, and FDM-manufacturable prosthetic elbow joint based on compliant mechanisms.
- 1 August 2026
- Published by IOP Publishing in Engineering Research Express
- Vol. 8 (16) , 165526
Design and experimental validation of ligament-mimetic compliant joints for 3D-printed prosthetic elbows
This study presents the design and experimental validation of a prosthetic elbow joint based on compliant mechanisms that mimic the function of elbow ligaments. The proposed design uses crossed flexural beams to enable two modes of motion—flexion–extension and pronation–supination—while reducing the need for discrete mechanical components. Eighteen flexural-beam configurations were evaluated for each motion mode by varying the number of flexural beam elements, beam width, beam thickness, and reinforcement topology. Finite element analysis was used to evaluate maximum equivalent stress, deformation response, and actuation force at maximum deformation. The results showed a nonlinear relationship between rotation angle and both maximum equivalent stress and required actuation force. The flexural-beam analysis also indicated that beam thickness strongly influenced joint stiffness, consistent with the cubic dependence of bending stiffness on thickness. For preliminary validation, six configurations were fabricated using fused deposition modeling (FDM) with PETG and experimentally tested. The highest agreement between experimental and finite element results was observed with R 2 = 0.924 . A Pareto-based multi-objective design selection method was then applied to identify the optimal configuration by minimizing equivalent stress while maintaining low actuation force. The selected mechanisms were integrated into a lightweight prototype measuring 87.1 mm in length and weighing 160 g. The prototype achieved the required range of motion for flexion–extension and pronation–supination. However, the 1 kg load-bearing requirement was only partially satisfied, as the device supported the load in full extension but could not maintain it at approximately 90 ∘ of flexion. Overall, this study establishes mechanics-based design guidelines for a flexible, compact, and FDM-manufacturable prosthetic elbow joint based on compliant mechanisms.
- Open Access
- 29 July 2024
- Published by JURUFRA SL in Retos
- Vol. 59, 355-359
Measuring shoulder range of motion to diagnose shoulder injury among weightlifters: a study in athletes with and without shoulder injury
Background: Weightlifting is one of the sports that contribute to Olympic medals for Indonesia. With the demand to contribute medals at the Olympics, a thorough screening is needed to evaluate athletes for possible risks of injury. Moreover, the lifting movements involve the joints, muscles, and skeleton. Therefore, the sport poses a very high risk of injury, especially to the shoulders. Knowing the athlete's Range of Motion (ROM) is important to see a good range of motion. This study aimed to observe ROM differences between injured and non-injured weightlifters. Method: An observational study was conducted on 16 athletes (10 male and 6 female) with the following characteristics for male (24.1 ± 6.7 years, 168.2 ± 2.5 cm, 83.0 ± 11.9 kg, 29.2 ± 4.0 kg/m2) and female (18.8 ± 1.6 years, 158.6 ± 3.8 cm, 65.2 ± 7.9 kg, 27.2 ± 4.5 kg/m2) participants. In data analysis, all athletes went through the screening stage. After that, the body composition and ROM of both arms were measured using InBody 270 and Humantrak 3D Human Movement Analysis, with statistical significance determined at a value <0.05 using the Mann-Whitney test in Minitab. Result: The study found a significant difference in the range of motion of the shoulder between athletes who had injuries and those who did not have injuries. Conclusion: This research revealed a decreased range of motion in weightlifting athletes with injuries. Keywords: Weightlifter, Injury, Range of Motion, Shoulder
- 29 July 2024
- Published by JURUFRA SL in Retos
- Vol. 59, 355-359
Open AccessMeasuring shoulder range of motion to diagnose shoulder injury among weightlifters: a study in athletes with and without shoulder injury
Background: Weightlifting is one of the sports that contribute to Olympic medals for Indonesia. With the demand to contribute medals at the Olympics, a thorough screening is needed to evaluate athletes for possible risks of injury. Moreover, the lifting movements involve the joints, muscles, and skeleton. Therefore, the sport poses a very high risk of injury, especially to the shoulders. Knowing the athlete's Range of Motion (ROM) is important to see a good range of motion. This study aimed to observe ROM differences between injured and non-injured weightlifters. Method: An observational study was conducted on 16 athletes (10 male and 6 female) with the following characteristics for male (24.1 ± 6.7 years, 168.2 ± 2.5 cm, 83.0 ± 11.9 kg, 29.2 ± 4.0 kg/m2) and female (18.8 ± 1.6 years, 158.6 ± 3.8 cm, 65.2 ± 7.9 kg, 27.2 ± 4.5 kg/m2) participants. In data analysis, all athletes went through the screening stage. After that, the body composition and ROM of both arms were measured using InBody 270 and Humantrak 3D Human Movement Analysis, with statistical significance determined at a value <0.05 using the Mann-Whitney test in Minitab. Result: The study found a significant difference in the range of motion of the shoulder between athletes who had injuries and those who did not have injuries. Conclusion: This research revealed a decreased range of motion in weightlifting athletes with injuries. Keywords: Weightlifter, Injury, Range of Motion, Shoulder
- Open Access
- 5 September 2022
- Published by The Institute for Research and Community Services (LPPM) ITB in Journal of Engineering and Technological Sciences
- Vol. 54 (5) , 220503
Markerless Optical Motion Capture System for Asymmetrical Swimming Stroke
This work presents the development of a markerless optical motion capture system of the front-crawl swimming stroke. The system only uses one underwater camera to record swimming motion in the sagittal plane. The participant in this experiment was a swimmer who is active in the university?s swimming club. The recorded images were then segmented to obtain silhouettes of the participant by a Gaussian Mixture Model. One of the swimming images was employed to generate a human body model that consists of 15 segments. The silhouette and model of the participant were subjected to an image matching process. The shape of the body segment was used as the feature in the image matching. The model was transformed to estimate the pose of the participant. The intraclass correlation coefficient between the results of the developed system and references were evaluated. In general, all body segments, except head and trunk, had a correlation coefficient higher than 0.95. Then, dynamics analysis by SWUM was conducted based on the joint angle acquired by the present work. The simulation implied that the developed system was suitable for daily training of athletes and coaches due to its simplicity and accuracy.
- 5 September 2022
- Published by The Institute for Research and Community Services (LPPM) ITB in Journal of Engineering and Technological Sciences
- Vol. 54 (5) , 220503
Open AccessMarkerless Optical Motion Capture System for Asymmetrical Swimming Stroke
This work presents the development of a markerless optical motion capture system of the front-crawl swimming stroke. The system only uses one underwater camera to record swimming motion in the sagittal plane. The participant in this experiment was a swimmer who is active in the university?s swimming club. The recorded images were then segmented to obtain silhouettes of the participant by a Gaussian Mixture Model. One of the swimming images was employed to generate a human body model that consists of 15 segments. The silhouette and model of the participant were subjected to an image matching process. The shape of the body segment was used as the feature in the image matching. The model was transformed to estimate the pose of the participant. The intraclass correlation coefficient between the results of the developed system and references were evaluated. In general, all body segments, except head and trunk, had a correlation coefficient higher than 0.95. Then, dynamics analysis by SWUM was conducted based on the joint angle acquired by the present work. The simulation implied that the developed system was suitable for daily training of athletes and coaches due to its simplicity and accuracy.
- 19 August 2022
- Published by Springer Nature
- p. 377-384
Human Gait Parameters Calculation Based on Partial Motion Data
- 19 August 2022
- Published by Springer Nature
- p. 377-384
Human Gait Parameters Calculation Based on Partial Motion Data
- 21 September 2016
- Published by Springer Nature in Sports Engineering
- Vol. 20 (1) , 63-72
Development of a markerless optical motion capture system for daily use of training in swimming
- 21 September 2016
- Published by Springer Nature in Sports Engineering
- Vol. 20 (1) , 63-72
Development of a markerless optical motion capture system for daily use of training in swimming
- 3 September 2013
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 393, 976-981
Camera Calibration Technique Improvement for 3D Optical Gait Analyzer System
In the present work, improvement in camera calibration technique to increase the accuracy of 3D optical gait analyzer system is presented. The improvement was based on correction and modification of the work that has been reported by Zhengyou Zhang. Lens distortions: radial, decentering, and thin-prism distortion were also considered into camera calibration process to minimize the systems error. In the calibration, the projection matrix of Zhangs model was corrected. In addition to that, non-linear constraint in lens distortion calculation was also avoided in order to make the calculation process more efficient. To evaluate the accuracy and efficiency of the proposed method, comparison between present calibration techniques with other camera calibration techniques is conducted. The results show that the proposed technique gives the most accurate result and most efficient calculation process compared to the Direct Linear Transformation (DLT) and Modified Direct Linear Transformation (MDLT) techniques. By using the proposed technique, the root mean square error of the results, if all the lens distortions are considered in calculation, is 0.627 cm with the processing time of 0.1152 s.
- 3 September 2013
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 393, 976-981
Camera Calibration Technique Improvement for 3D Optical Gait Analyzer System
In the present work, improvement in camera calibration technique to increase the accuracy of 3D optical gait analyzer system is presented. The improvement was based on correction and modification of the work that has been reported by Zhengyou Zhang. Lens distortions: radial, decentering, and thin-prism distortion were also considered into camera calibration process to minimize the systems error. In the calibration, the projection matrix of Zhangs model was corrected. In addition to that, non-linear constraint in lens distortion calculation was also avoided in order to make the calculation process more efficient. To evaluate the accuracy and efficiency of the proposed method, comparison between present calibration techniques with other camera calibration techniques is conducted. The results show that the proposed technique gives the most accurate result and most efficient calculation process compared to the Direct Linear Transformation (DLT) and Modified Direct Linear Transformation (MDLT) techniques. By using the proposed technique, the root mean square error of the results, if all the lens distortions are considered in calculation, is 0.627 cm with the processing time of 0.1152 s.
- 1 July 2013
- Published by IGI Global Scientific Publishing in International Journal of E-Health and Medical Communications
- Vol. 4 (3) , 36-52
Tracking of Markers for 2D and 3D Gait Analysis Using Home Video Cameras
Tracking of Markers for 2D and 3D Gait Analysis Using Home Video Cameras: 10.4018/jehmc.2013070103: This work presents the development of an affordable optical motion-capture system which uses home video cameras for 2D and 3D gait analysis. The 2D gait
- 1 July 2013
- Published by IGI Global Scientific Publishing in International Journal of E-Health and Medical Communications
- Vol. 4 (3) , 36-52
Tracking of Markers for 2D and 3D Gait Analysis Using Home Video Cameras
Tracking of Markers for 2D and 3D Gait Analysis Using Home Video Cameras: 10.4018/jehmc.2013070103: This work presents the development of an affordable optical motion-capture system which uses home video cameras for 2D and 3D gait analysis. The 2D gait
- 1 November 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 391-394
Development of an optical motion-capture system for 3D gait analysis
This work presents the development of an optical motion-capture system for 3D gait analysis. The system consists of two video cameras with speed of 25 fps, flash lighter, LED markers, and two PCs and technical computing software, which are used to acquire marker motion attached to human body during walking. The developed system has five module to obtain real coordinate of markers, i.e. pre-processing, camera calibration, marker detection and tracking, 3D reconstruction, and post-processing module. In the experiment, two camcorders are synchronized using flashlight. The recorded videos from experiment are extracted into frames. The synchronized framesare converted into binary images and marker position can be detected and tracked using least distance method. 3D Direct Linear Transformation method has been used to reconstruct 3D marker position in real coordinate. The marker positions data obtained from experiment could then be used for further kinematics and kinetics analysis of human gait.
- 1 November 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 391-394
Development of an optical motion-capture system for 3D gait analysis
This work presents the development of an optical motion-capture system for 3D gait analysis. The system consists of two video cameras with speed of 25 fps, flash lighter, LED markers, and two PCs and technical computing software, which are used to acquire marker motion attached to human body during walking. The developed system has five module to obtain real coordinate of markers, i.e. pre-processing, camera calibration, marker detection and tracking, 3D reconstruction, and post-processing module. In the experiment, two camcorders are synchronized using flashlight. The recorded videos from experiment are extracted into frames. The synchronized framesare converted into binary images and marker position can be detected and tracked using least distance method. 3D Direct Linear Transformation method has been used to reconstruct 3D marker position in real coordinate. The marker positions data obtained from experiment could then be used for further kinematics and kinetics analysis of human gait.