Marie Vandeput
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Marie Vandeput has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Jean-Michel Kauffmann
Laboratory of Instrumental Analysis and Bioelectrochemistry, Faculty of Pharmacy, Université Libre de Bruxelles, Boulevard du Triomphe, Campus Plaine, CP 205/06, 1050 Brussels, Belgium
7 shared publications Ahmad Sarakbi
3 shared publicationsJean-Michel Kauffmann
3 shared publicationsStéphanie Patris
3 shared publicationsCobra Parsajoo
2 shared publicationsDominique Mertens
Université libre de Bruxelles (ULB), Faculty of Pharmacy, Campus Plaine, CP 205/6, 1050 Brussels, Belgium
2 shared publications
Latest Publications
- Open Access
- 31 December 2024
- Published by European Journal of Chemistry in European Journal of Chemistry
- Vol. 15 (4) , 307-312
Redox behavior of aliphatic hydroxamic acid and its iron(III) complexes
N-Hydroxydodecanamide (HA12) and its trihydroxamato-iron(III) complex (HA12Fe3) have been synthesized and characterized by various methods including structural determination by single crystal X-ray diffraction and cyclic voltammetry (CV). In order to complete our previous CV study on HA12 and its complexes, our aim was to investigate the variation in redox potential upon changes in concentration and pH. The redox couples previously observed with HA12 and HA12Fe3 at 100 µM shifts towards less positive values when the concentration or pH of the solution increases. These results indicate that oxidation is easier when concentrations are higher and in basic media. The slopes of -0.06 V/pH (in agreement with the theoretical data) and -0.077 V/pH (slightly higher than the theoretical slope) were observed for HA12 and HA12Fe3, respectively. This observation would explain the slower oxidation of HA12Fe3 than HA12.
- 31 December 2024
- Published by European Journal of Chemistry in European Journal of Chemistry
- Vol. 15 (4) , 307-312
Open AccessRedox behavior of aliphatic hydroxamic acid and its iron(III) complexes
N-Hydroxydodecanamide (HA12) and its trihydroxamato-iron(III) complex (HA12Fe3) have been synthesized and characterized by various methods including structural determination by single crystal X-ray diffraction and cyclic voltammetry (CV). In order to complete our previous CV study on HA12 and its complexes, our aim was to investigate the variation in redox potential upon changes in concentration and pH. The redox couples previously observed with HA12 and HA12Fe3 at 100 µM shifts towards less positive values when the concentration or pH of the solution increases. These results indicate that oxidation is easier when concentrations are higher and in basic media. The slopes of -0.06 V/pH (in agreement with the theoretical data) and -0.077 V/pH (slightly higher than the theoretical slope) were observed for HA12 and HA12Fe3, respectively. This observation would explain the slower oxidation of HA12Fe3 than HA12.
- 6 November 2017
- Published by Wiley in Electroanalysis
- Vol. 30 (7) , 1293-1302
Electrochemical Studies of Ethoxyquin and its Determination in Salmon Samples by Flow Injection Analysis with an Amperometric Dual Detector
Ethoxyquin (EQ) is an antioxidant widely used in the food industry. Some concerns for human health have been reported since its utilization in animal feed may lead to residues in human food such as salmon samples. This work aimed to investigate the electrochemical behavior of EQ and its major oxidation products namely a dimer of EQ (EQDM) and ethoxyquin quinone imine (EQI) by cyclic voltammetry (CV) at a carbon screen printed electrode (cSPE). The stability of these products and their reactivity against glutathione (GSH) were also studied. Oxidized products and thiol adducts were identified by a microelectrolysis of an EQ solution onto a cSPE in the absence and in the presence of GSH. The products were analyzed off‐line, by liquid chromatography coupled to a mass spectrometer (LC‐MS). One of the generated product (EQI) was shown to be highly reactive towards GSH. Based on the redox pattern of EQ, a flow injection analysis with a dual cSPE was developed in order to detect in a rapid manner EQ in salmon samples. Since matrix effects were observed, matrix‐matched calibration curves with spiked samples were built. A linear response was obtained between 20–100 μM and a limit of detection (LOD) of 7.5 μM (8.2 mg/kg of salmon). Trueness was assessed with recovery assays at three levels of concentration. The recovery was close to 100 %. Precision was determined as RSD (%) with values lower than 6 % in all cases.
- 6 November 2017
- Published by Wiley in Electroanalysis
- Vol. 30 (7) , 1293-1302
Electrochemical Studies of Ethoxyquin and its Determination in Salmon Samples by Flow Injection Analysis with an Amperometric Dual Detector
Ethoxyquin (EQ) is an antioxidant widely used in the food industry. Some concerns for human health have been reported since its utilization in animal feed may lead to residues in human food such as salmon samples. This work aimed to investigate the electrochemical behavior of EQ and its major oxidation products namely a dimer of EQ (EQDM) and ethoxyquin quinone imine (EQI) by cyclic voltammetry (CV) at a carbon screen printed electrode (cSPE). The stability of these products and their reactivity against glutathione (GSH) were also studied. Oxidized products and thiol adducts were identified by a microelectrolysis of an EQ solution onto a cSPE in the absence and in the presence of GSH. The products were analyzed off‐line, by liquid chromatography coupled to a mass spectrometer (LC‐MS). One of the generated product (EQI) was shown to be highly reactive towards GSH. Based on the redox pattern of EQ, a flow injection analysis with a dual cSPE was developed in order to detect in a rapid manner EQ in salmon samples. Since matrix effects were observed, matrix‐matched calibration curves with spiked samples were built. A linear response was obtained between 20–100 μM and a limit of detection (LOD) of 7.5 μM (8.2 mg/kg of salmon). Trueness was assessed with recovery assays at three levels of concentration. The recovery was close to 100 %. Precision was determined as RSD (%) with values lower than 6 % in all cases.
- 1 September 2017
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 248, 385-394
Application of a tyrosinase microreactor – detector in a flow injection configuration for the determination of affinity and dynamics of inhibitor binding
- 1 September 2017
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 248, 385-394
Application of a tyrosinase microreactor – detector in a flow injection configuration for the determination of affinity and dynamics of inhibitor binding
- 21 February 2017
- Published by Wiley in Electroanalysis
- Vol. 29 (5) , 1451-1458
A Reduced Graphene Oxide‐based Electrochemical DNA Biosensor for the Detection of Interaction between Cisplatin and DNA based on Guanine and Adenine Oxidation Signals
A glassy carbon electrode (GCE) was modified by electrochemically reduced graphene oxide (ERGO) for subsequent dsDNA immobilization. The interaction of cisplatin with dsDNA was studied at this modified electrode. Quantitative investigations were performed by adsorptive transfer stripping voltammetry (AdTSV) using differential pulse voltammetry (DPV). The morphology and structure of graphene oxide (GO) and ERGO modified GCEs (GO/GCE and ERGO/GCE, respectively) were characterized by UV‐vis, FT‐IR, Raman spectroscopy and cyclic voltammetry. Compared with the bare GCE and the GO/GCE, the ERGO/GCE exhibited excellent electrocatalytic activity towards the oxidation of dsDNA due to guanine and adenine groups, testified by high oxidation peak currents and decreased oxidation potentials. The interaction of micromolar concentrations of cisplatin with surface confined dsDNA was readily detected as inferred from the decrease of the voltammetric oxidation peaks of guanine and adenine. This trend was significantly greater at the ERGO/GCE compared to the GO/GCE. The interaction of cisplatin with dsDNA was also studied in solution phase by AdTSV with detection at the ERGO/GCE.
- 21 February 2017
- Published by Wiley in Electroanalysis
- Vol. 29 (5) , 1451-1458
A Reduced Graphene Oxide‐based Electrochemical DNA Biosensor for the Detection of Interaction between Cisplatin and DNA based on Guanine and Adenine Oxidation Signals
A glassy carbon electrode (GCE) was modified by electrochemically reduced graphene oxide (ERGO) for subsequent dsDNA immobilization. The interaction of cisplatin with dsDNA was studied at this modified electrode. Quantitative investigations were performed by adsorptive transfer stripping voltammetry (AdTSV) using differential pulse voltammetry (DPV). The morphology and structure of graphene oxide (GO) and ERGO modified GCEs (GO/GCE and ERGO/GCE, respectively) were characterized by UV‐vis, FT‐IR, Raman spectroscopy and cyclic voltammetry. Compared with the bare GCE and the GO/GCE, the ERGO/GCE exhibited excellent electrocatalytic activity towards the oxidation of dsDNA due to guanine and adenine groups, testified by high oxidation peak currents and decreased oxidation potentials. The interaction of micromolar concentrations of cisplatin with surface confined dsDNA was readily detected as inferred from the decrease of the voltammetric oxidation peaks of guanine and adenine. This trend was significantly greater at the ERGO/GCE compared to the GO/GCE. The interaction of cisplatin with dsDNA was also studied in solution phase by AdTSV with detection at the ERGO/GCE.
- 20 May 2016
- Published by Bentham Science Publishers Ltd. in Current Drug Delivery
- Vol. 13 (3) , 371-377
Contribution of Electrochemistry to the Biomedical and Pharmaceutical Analytical Sciences
All analytical techniques have experienced major progress since the last ten years and electroanalysis is also involved in this trend. The unique characteristics of phenomena occurring at the electrode-solution interface along with the variety of electrochemical methods currently available allow for a broad spectrum of applications. Potentiometric, conductometric, voltammetric and amperometric methods are briefly reviewed with a critical view in terms of performance of the developed instrumentation with special emphasis on pharmaceutical and biomedical applications.
- 20 May 2016
- Published by Bentham Science Publishers Ltd. in Current Drug Delivery
- Vol. 13 (3) , 371-377
Contribution of Electrochemistry to the Biomedical and Pharmaceutical Analytical Sciences
All analytical techniques have experienced major progress since the last ten years and electroanalysis is also involved in this trend. The unique characteristics of phenomena occurring at the electrode-solution interface along with the variety of electrochemical methods currently available allow for a broad spectrum of applications. Potentiometric, conductometric, voltammetric and amperometric methods are briefly reviewed with a critical view in terms of performance of the developed instrumentation with special emphasis on pharmaceutical and biomedical applications.
- 1 May 2016
- Published by Elsevier in TrAC Trends in Analytical Chemistry
- Vol. 79, 239-246
Antibodies as target for affinity biosensors
- 1 May 2016
- Published by Elsevier in TrAC Trends in Analytical Chemistry
- Vol. 79, 239-246
Antibodies as target for affinity biosensors
- 1 March 2016
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 77, 457-463
An experimental design approach to optimize an amperometric immunoassay on a screen printed electrode for Clostridium tetani antibody determination
- 1 March 2016
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 77, 457-463
An experimental design approach to optimize an amperometric immunoassay on a screen printed electrode for Clostridium tetani antibody determination
- 29 May 2015
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 87 (13) , 6730-6735
Liquid Chromatography with Amperometric Detection at a Silver Based Detector for the Determination of Thiocompounds: Application to the Assay of Thiopurine Antimetabolites in Urine
A silver amperometric detector coupled to liquid chromatography (LC) was used for the determination of 6-thioguanine (6-TG) and two of its metabolites, thiouric acid (TU) and 2-amino-6-mercaptopurine riboside (6-TGR). The silver detector coupled to LC operated at a low applied potential (0.08 V vs Ag/AgCl) and offered a chromatogram with peak responses corresponding to molecules interacting with silver, namely, chloride ions and small soluble biothiols in addition to the organothiol drug compounds investigated. Online electrochemical surface cleaning permitted the improvement of the repeatability and peak shape of the recorded signal compared to direct current amperometric detection (AD) when operating in chloride containing media. The studied molecules were eluted isocratically within 5 min on a reversed-phase C18 column without interference from endogenous biothiols present in urine samples. Diluted urine samples (1:1) were directly injected in the LC setup; a linear calibration curve was obtained between peak area and analyte concentration between 0.1 and 10 μM for all the studied molecules. Limits of detection (LODs) were 0.03, 0.008, and 0.01 μM, and the limits of quantification (LOQs) were 0.1, 0.02, and 0.03 μM for TU, 6-TG, and 6-TGR, respectively. Within-day RSDs were 2%, 0.8%, and 1% and between-day RSDs were 2%, 0.9%, 2% for TU, 6-TG, and 6-TGR, respectively. Recoveries in spiked urine were 99.8%, 99.9%, and 99.0% for TU, 6-TG, and 6-TGR, respectively.
- 29 May 2015
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 87 (13) , 6730-6735
Liquid Chromatography with Amperometric Detection at a Silver Based Detector for the Determination of Thiocompounds: Application to the Assay of Thiopurine Antimetabolites in Urine
A silver amperometric detector coupled to liquid chromatography (LC) was used for the determination of 6-thioguanine (6-TG) and two of its metabolites, thiouric acid (TU) and 2-amino-6-mercaptopurine riboside (6-TGR). The silver detector coupled to LC operated at a low applied potential (0.08 V vs Ag/AgCl) and offered a chromatogram with peak responses corresponding to molecules interacting with silver, namely, chloride ions and small soluble biothiols in addition to the organothiol drug compounds investigated. Online electrochemical surface cleaning permitted the improvement of the repeatability and peak shape of the recorded signal compared to direct current amperometric detection (AD) when operating in chloride containing media. The studied molecules were eluted isocratically within 5 min on a reversed-phase C18 column without interference from endogenous biothiols present in urine samples. Diluted urine samples (1:1) were directly injected in the LC setup; a linear calibration curve was obtained between peak area and analyte concentration between 0.1 and 10 μM for all the studied molecules. Limits of detection (LODs) were 0.03, 0.008, and 0.01 μM, and the limits of quantification (LOQs) were 0.1, 0.02, and 0.03 μM for TU, 6-TG, and 6-TGR, respectively. Within-day RSDs were 2%, 0.8%, and 1% and between-day RSDs were 2%, 0.9%, 2% for TU, 6-TG, and 6-TGR, respectively. Recoveries in spiked urine were 99.8%, 99.9%, and 99.0% for TU, 6-TG, and 6-TGR, respectively.
- 1 January 2015
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 102, 267-275
Flow-through enzyme immobilized amperometric detector for the rapid screening of acetylcholinesterase inhibitors by flow injection analysis
- 1 January 2015
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 102, 267-275
Flow-through enzyme immobilized amperometric detector for the rapid screening of acetylcholinesterase inhibitors by flow injection analysis