NONoortje H. M. van Oostrum

Noortje H. M. van Oostrum

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Noortje H. M. van Oostrum has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Reproducibility of fetal global longitudinal strain measured with speckle tracking echocardiography using a fixed cardiac cycle

    by Eline Meireson, Chantelle de Vet, Judith O. E. H. van Laar, Phaedra Mussche, Kristien Roelens, Noortje H. M. van Oostrum

    Fetal speckle tracking echocardiography is an ultrasound-based technique used to assess myocardial velocity and deformation of the fetal heart. Despite its potential, the method has not yet been integrated into routine pregnancy care, partly due to concerns about inconsistent reproducibility. This study aimed to evaluate the intra- and inter-observer reproducibility of global longitudinal strain measurements derived from a fixed fetal cardiac cycle, using speckle tracking echocardiography. Healthy women with singleton pregnancies were enrolled during the second trimester. From enrolment until delivery, four-chamber view clips of the fetal heart were acquired every four weeks. For intra-observer reproducibility, a single observer analyzed the same heart cycle in one DICOM clip twice for global longitudinal strain in the left and right ventricles, with a minimum interval of two weeks between assessments in a blinded manner. For inter-observer reproducibility, two independent observers analyzed the same cardiac cycle within one DICOM clip. A total of 124 women were included, yielding 632 ultrasound clips. Intra-observer reproducibility was poor to moderate for global longitudinal strain for the right and left ventricles. Inter-observer reproducibility demonstrated moderate to good reproducibility for global longitudinal strain in both ventricles. The reproducibility was generally higher in the left ventricle than in the right, and the highest reproducibility was observed before 32 weeks of gestation. In conclusion, speckle tracking echocardiography during pregnancy showed variable reproducibility of strain analysis when performed on a fixed cardiac cycle, with more consistent results in the left ventricle. These findings support the potential utility of fetal speckle tracking echocardiography, while highlighting the need for further refinement of reproducibility before clinical implementation.

  • Two‐dimensional speckle‐tracking echocardiography in fetal medicine: what next?

    by A. Dall'ASta, N. van Oostrum, J. van Laar, F. Crispi


  • Open Access

    Two-dimensional fetal speckle tracking; a learning curve study for offline strain analysis

    by Chantelle M de Vet, Thomas J Nichting, Annemarie F Fransen, Daisy A A van der Woude, Myrthe van der Ven, Richard A J Post, Zoé van Lier, S Guid Oei, Noortje H M van Oostrum, Judith O E H van Laar

    Objectives: Two-dimensional speckle tracking (2D-STE) strain analysis holds promise for assessing fetal cardiac function. Understand the learning curve before introducing 2D-STE into obstetrics is crucial. This study examined the learning curve for offline analysis of fetal left (LV) and right ventricular (RV) global longitudinal strain (GLS) using 2D-STE. Methods: After 2D-STE training, three trainees (Maternal-Fetal Medicine fellow, OBGYN resident and medical student) analyzed 100 fetal heart clips using 2D-STE to calculate LV- and RV-GLS. Intra-class correlation coefficients (ICC) and Bland-Altman plots were compared GLS values across four sets of 25 clips for each trainee against the expert. Repeated measurements analysis compared GLS score differences between expert and trainees over time and among trainees, adjusting p-values with a Bonferroni correction. Results: LV-GLS consistency evolved from poor-to-moderate during the first 50 measurements to moderate-to-good during the second 50 for all trainees. RV-GLS consistency evolved from poor-to-moderate during the first 75 measurements to moderate-to-good during the final 25 measurements for the fellow and resident. The student’s RV-GLS consistency was poor during the first 25 measurements, moderate-to good during the second 25 measurements and again poor-to-moderate during the final 50 measurements. Repeated measurements analysis showed a significant decrease in variability of the LV- and RV-GLS score differences between the expert and trainees over time (padjpadjpadj = 0.029), and did significantly change over time for RV-GLS (padj<0.001) but not for LV-GLS. Conclusions: A clear learning effect was observed by the significant decrease in variability of the difference in the score between the expert and trainees over time. The consistency of fetal GLS analysis with 2D-STE was generally found to be moderate to good after 100 measurements in trainees.


  • Open Access

    Fetal myocardial deformation measured with two‐dimensional speckle‐tracking echocardiography: longitudinal prospective cohort study of 124 healthy fetuses

    by N. H. M. van Oostrum, C. M. de Vet, S. B. Clur, D. A. A. van der Woude, E. R. van Den Heuvel, S. G. Oei, J. O. E. H. van Laar

    Objectives: Two‐dimensional speckle‐tracking echocardiography (2D‐STE) is a promising technique which allows assessment of fetal cardiac function, and can be used in the evaluation of cardiac and non‐cardiac diseases in pregnancy. However, reliable fetal reference values for deformation parameters measured using 2D‐STE are needed before it can be introduced into clinical practice. This study aimed to obtain reference values for fetal global longitudinal strain (GLS) and GLS rate (GLSR) measured using 2D‐STE and compare right and left ventricular values.Methods: This was a prospective longitudinal cohort study of uncomplicated pregnancies that underwent echocardiography every 4 weeks from inclusion at 18–21 weeks until delivery to obtain four‐chamber loops of the fetal heart. Left and right ventricular GLS and GLSR were measured using 2D‐STE at each examination. Using Bayesian mixed‐effects models, reference values with lower and upper 5% prediction limits were calculated according to gestational age. Right and left ventricular GLS values according to gestational age were compared using the Wilcoxon signed‐rank test.Results: A total of 592 left ventricular and 566 right ventricular GLS and GLSR measurements were obtained from 124 women with uncomplicated pregnancy and non‐anomalous, appropriately grown fetuses. Reference values were obtained for both fetal ventricles according to gestational week. GLS and GLSR values of both ventricles increased (i.e. became less negative) significantly during pregnancy. Right ventricular GLS values were significantly higher (i.e. less negative) than the respective left ventricular values at every gestational week.Conclusions: Reference values were obtained for fetal GLS and GLSR measured using 2D‐STE. GLS and GLSR values increased significantly for both ventricles from the second trimester until delivery. GLS values were significantly higher for the right ventricle compared with the left ventricle. Future studies are needed to assess whether the obtained reference values are helpful in clinical practice in the assessment of pregnancy complications, such as fetal growth restriction or cardiac anomaly. © 2022 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


  • A randomized controlled trial studying the effect of maternal hyperoxygenation on fetal heart rate in suspected fetal distress

    by S Moors, R Joshi, L M Bullens, N H M van Oostrum, M Regis, E R van Den Heuvel, S G Oei, J O E H van Laar, M B van der Hout-Van der Jagt

    Objective : To investigate the effect of maternal hyperoxygenation on fetal heart rate (FHR) when applied for suspected fetal distress during the second stage of term labor. Approach : A single-center randomized controlled trial was conducted in a tertiary care hospital in The Netherlands. Participants were included during the second stage of labor in case of an intermediary or abnormal FHR pattern. Patients were randomized to receive either 100% oxygen at 10 l/min until delivery, or conventional care without additional oxygen. The primary outcome was the change in FHR pattern before and after the onset of the study, measured as the change in depth and duration of FHR decelerations. Secondary outcome measures were features based on phase-rectified signal averaging (PRSA), baseline assignability, and deceleration characteristics of the FHR pattern. Main results : Between March 2016 and April 2018, 117 women were included. The FHR pattern could be analyzed for 71 participants, the other 46 women delivered before the end of the post time-frame. A 2.3% reduction in depth and duration of FHR decelerations was found after maternal hyperoxygenation, compared to a 10% increase in the control group ( p = 0.24). Maternal hyperoxygenation had a significantly positive effect on PRSA metrics, with a decrease in PRSA-acceleration capacity ( p = 0.03) and PRSA-deceleration capacity ( p = 0.02) in the intervention group compared to the control group. Significance : The difference in depth and duration of decelerations after the start of the study was not significantly different between both study groups. A statistically significant positive effect on PRSA-deceleration capacity and PRSA-acceleration capacity was found after maternal hyperoxygenation, which might be associated with a positive effect on neonatal outcome.


  • Two-dimensional Speckle tracking echocardiography in Fetal Growth Restriction: a systematic review

    by Noortje H.M. van Oostrum, Kris Derks, Daisy.A.A. van der Woude, S.A. Clur, S. Guid Oei, Judith O.E.H van Laar


  • Right ventricular dysfunction identified by abnormal strain values precedes evident growth restriction in small for gestational age fetuses

    by Noortje H M van Oostrum, Daisy A A van der Woude, Sally-Ann B Clur, S Guid Oei, Judith O E H van Laar

    Objectives: Small for gestational age (SGA) fetuses have an increased risk for adverse outcome. Placental insufficiency leads to changes in the circulation, with secondary adaptation of the fetal heart resulting in changed cardiac deformation. This deformation can be measured with 2D speckle tracking echocardiography (2D‐STE). SGA is antenatally often undiagnosed. The measurement of deformation changes in the fetal heart might help in the prediction of SGA and identify fetuses in need of more intensive surveillance.Methods: In this longitudinal prospective cohort study, global longitudinal strain (GLS) and strain rate (GLSR), measured before 23 weeks gestational age were compared between SGA and appropriate for gestational age (AGA) fetuses, based on birthweight corrected for gestational age at birth.Results: The fetal heart rate was significantly increased in SGA; 158 beats per minute (146‐163) vs 148 (134‐156); P = 0.035 in AGA. Right ventricle GLS (RV‐GLS) values were significantly increased in SGA; −15.87% (−11.69% to −20.55%) vs −20.24% (−16.29% to −24.28%); p = 0.024, respectively.Conclusion: RV‐GLS values, measured with 2D‐STE, were significantly increased in SGA, indicating systolic RV dysfunction before 23 weeks gestational age in fetuses who will become SGA later in pregnancy. A large longitudinal prospective cohort study is needed to confirm these findings.


  • Fetal strain and strain rate during pregnancy measured with speckle tracking echocardiography: A systematic review

    by Noortje H.M. van Oostrum, Chantelle M. de Vet, Daisy A.A. van der Woude, Hareld M.C. Kemps, S. Guid Oei, Judith O.E.H. van Laar


  • Open Access

    Normal fetal cardiac deformation values in pregnancy; a prospective cohort study protocol

    by Noortje H. M. van Oostrum, S. Guid Oei, Judith O. E. H. van Laar

    Background: Myocardial deformation imaging offers the potential to measure myocardial function. Remodelling, the change in size, shape and function, appears as a result of pressure or volume changes and is thought to be the first sign of fetal adaptation to placental dysfunction. Deformation can be measured using speckle tracking echocardiography (STE). STE in the fetus might be useful for detection and follow up of the fetus endangered by placental dysfunction. Reference values for fetal myocardial deformation during gestation have not been comprehensively described and need further investigation before STE can be introduced in daily clinical practice. The aim of this study is to determine reference values for fetal myocardial deformation throughout gestation in uncomplicated pregnancies. Methods: A longitudinal cohort will be performed. 150 Women, pregnant from a non-anomalous singleton, will be included from 19 to 21 + 6 weeks gestational age. Thereafter, fetal heart ultrasounds will be performed 4 weekly, until 41 weeks gestational age or delivery. Ultrasound data will be analysed using STE software to determine reference values for fetal cardiac deformation during gestation. Discussion: Measuring cardiac deformation changes in pregnancy can be a promising tool to detect preclinical cardiac adaptation to placental dysfunction. However, previous studies used different ultrasound scans and STE software resulting in incomparable and contradictory results on deformation values. In this prospective study reference values during pregnancy, cardiac deformation values will be assessed with the same ultrasound and software package in 150 uncomplicated pregnancies. Trial registration: National Trial Register number: NTR7132. Date of inclusion: 2018/04/06.