Ziad Tarik Al-Dahan
Ziad Tarik Al-Dahan has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Ahmed Riedh Al-Hamaoy
Department of Laser and optoelectronics Engineering Al-Nahrain University Baghdad Iraq
2 shared publications - Basma A. Al-Ghali
Department of Biomedical Engineering, College of Engineering, Al-Nahrain University, Baghdad 10070, Iraq
2 shared publications - Zahraa Amer Salman
Laser and Optoelectronic Department, AlNahrain University, Baghdad, Iraq
2 shared publications Abbas Fathil Al-Hashimi
1 shared publicationAhmed Saad Al-Ghabban
1 shared publication- Alaa Nazar
Physics Department, College Science for Women, Baghdad University, Baghdad, Iraq
1 shared publication
Latest Publications
- 19 August 2025
- Published by Springer Nature in Journal of Optics
- p. 1-8
Evaluate the impact of skin tones on human body temperature during laser tattoo removal
- 19 August 2025
- Published by Springer Nature in Journal of Optics
- p. 1-8
Evaluate the impact of skin tones on human body temperature during laser tattoo removal
- Open Access
- 30 April 2025
- Published by University of Kufa in Kufa Journal of Engineering
- Vol. 16 (2) , 167-179
Using Orthodontic Wire electrodes in Gel Electrophoresis Device
Gel electrophoresis is an essential device in biology laboratories and life science centers for the analysis of macromolecules such as DNA, RNA, and protein. This separation technique mainly depends on using a set of electrode wires to generate an electric field within the gel medium. The most common failure is the electrode wire cut. This fault is due to corrosion or inadvertent cut of the thin platinum wire. Platinum wires are delicate, expensive, and not available in local markets. In this paper, orthodontic nickel-free stainless steel wire (diameter = 0.5 mm), is used as an alternative to the Platinum wire. The effectiveness of the orthodontic stainless steel wire was confirmed under high-level voltages (100, 150, and 250 Volts), and the data produced was reasonable, with good visualization of DNA fragments. However, the Anode wire experienced corrosion after about 11 hours, while the cathode is still effective. The study concluded that while not a long-term solution, nickel-free stainless steel orthodontic wire offers a simple, inexpensive (< $1) alternative to platinum electrodes for gel electrophoresis, especially for students and researchers conducting short-term experiments. However, using stainless steel with nickel is suggested to potentially enhance the lifespan of the electrodes due to nickel's contribution to corrosion resistance. Further research is recommended to explore its wider applications in molecular biology research and improve experimental procedures using this alternative electrode materiale.
- 30 April 2025
- Published by University of Kufa in Kufa Journal of Engineering
- Vol. 16 (2) , 167-179
Open AccessUsing Orthodontic Wire electrodes in Gel Electrophoresis Device
Gel electrophoresis is an essential device in biology laboratories and life science centers for the analysis of macromolecules such as DNA, RNA, and protein. This separation technique mainly depends on using a set of electrode wires to generate an electric field within the gel medium. The most common failure is the electrode wire cut. This fault is due to corrosion or inadvertent cut of the thin platinum wire. Platinum wires are delicate, expensive, and not available in local markets. In this paper, orthodontic nickel-free stainless steel wire (diameter = 0.5 mm), is used as an alternative to the Platinum wire. The effectiveness of the orthodontic stainless steel wire was confirmed under high-level voltages (100, 150, and 250 Volts), and the data produced was reasonable, with good visualization of DNA fragments. However, the Anode wire experienced corrosion after about 11 hours, while the cathode is still effective. The study concluded that while not a long-term solution, nickel-free stainless steel orthodontic wire offers a simple, inexpensive (< $1) alternative to platinum electrodes for gel electrophoresis, especially for students and researchers conducting short-term experiments. However, using stainless steel with nickel is suggested to potentially enhance the lifespan of the electrodes due to nickel's contribution to corrosion resistance. Further research is recommended to explore its wider applications in molecular biology research and improve experimental procedures using this alternative electrode materiale.
- 2 April 2025
- Published by Springer Nature in Journal of Optics
- p. 1-15
Review of laser skin treatments: parameters effects and common treatment cases
- 2 April 2025
- Published by Springer Nature in Journal of Optics
- p. 1-15
Review of laser skin treatments: parameters effects and common treatment cases
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2933 (1) , 080003
Non-dispersive infrared CO2 spectroscopy for extracorporeal life support: A digital signal processing design
Exhaled CO2 signal detection is demanding for being a weak signal with an absorption spectrum that is practically identical to that of H2O. Weak signals need a
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2933 (1) , 080003
Open AccessNon-dispersive infrared CO2 spectroscopy for extracorporeal life support: A digital signal processing design
Exhaled CO2 signal detection is demanding for being a weak signal with an absorption spectrum that is practically identical to that of H2O. Weak signals need a
- Open Access
- 26 July 2022
- Published by International Association of Online Engineering (IAOE) in International Journal of Online and Biomedical Engineering (iJOE)
- Vol. 18 (10) , 190-198
Non-Invasive Measurement of Arterial pH During Cardiopulmonary Bypass
Blood pH is an essential parameter to determine the patient's acid-base status during cardiopulmonary bypass. To date, continuous pH measurement is usually done by continuous blood sampling using an expensive disposable sensor. This paper shows the feasibility of measuring arterial pH from the partial pressure of carbon dioxide (PaCO2) using arterial blood gas analysis. Further, the effect of hyperglycemia on pH estimation is included to show the necessity of combining glucose monitoring with PaCO2 monitoring. 245 blood samples from patients who underwent cardiopulmonary bypass were used. Patients with renal failure were excluded from the study. In this study, three groups of samples were included, A: all blood samples, B: blood samples with glucose ≤ 200 mg/dL, and C: blood samples with glucose > 200 mg/dL. A linear approximation based on the least-squares criterion was used to derive the best-fit equation. Our results indicate that there is no significant difference among the models. Further, there is a significant association between arterial pH and PaCO2 with a p-value < 0.001 and RMSE of about 0.04. The present findings highlighted that arterial pH could be estimated from PaCO2. Additionally, hyperglycemia did not affect the hypothesis of the general relationship between pH and PaCO2.
- 26 July 2022
- Published by International Association of Online Engineering (IAOE) in International Journal of Online and Biomedical Engineering (iJOE)
- Vol. 18 (10) , 190-198
Open AccessNon-Invasive Measurement of Arterial pH During Cardiopulmonary Bypass
Blood pH is an essential parameter to determine the patient's acid-base status during cardiopulmonary bypass. To date, continuous pH measurement is usually done by continuous blood sampling using an expensive disposable sensor. This paper shows the feasibility of measuring arterial pH from the partial pressure of carbon dioxide (PaCO2) using arterial blood gas analysis. Further, the effect of hyperglycemia on pH estimation is included to show the necessity of combining glucose monitoring with PaCO2 monitoring. 245 blood samples from patients who underwent cardiopulmonary bypass were used. Patients with renal failure were excluded from the study. In this study, three groups of samples were included, A: all blood samples, B: blood samples with glucose ≤ 200 mg/dL, and C: blood samples with glucose > 200 mg/dL. A linear approximation based on the least-squares criterion was used to derive the best-fit equation. Our results indicate that there is no significant difference among the models. Further, there is a significant association between arterial pH and PaCO2 with a p-value < 0.001 and RMSE of about 0.04. The present findings highlighted that arterial pH could be estimated from PaCO2. Additionally, hyperglycemia did not affect the hypothesis of the general relationship between pH and PaCO2.
- 28 December 2017
- Published by ACCENTS in International Journal of Advanced Technology and Engineering Exploration
- Vol. 4 (37) , 174-180
High accurite reconstruction of external ear by use low-cost 3D scanner
- 28 December 2017
- Published by ACCENTS in International Journal of Advanced Technology and Engineering Exploration
- Vol. 4 (37) , 174-180
High accurite reconstruction of external ear by use low-cost 3D scanner
- Open Access
- 1 January 2014
- Published by Science Publishing Group in International Journal of Medical Imaging
- Vol. 2 (6) , 133
Predominant Peak Detection of QRS Complexes
This work presents a methodology for detection of QRS complexes which is an adaptation of Pan-Tompkins algorithm. This method includes band bass filtration, derivative, squaring, moving window integration, thresholding, false peak cancellation and detection the predominant peak of QRS complex. This method doing well in the presence of noise and simple ectopic beats but still affected by multifocal ectopic beats. The method was tested on the MIT-BIH Arrhythmia database and achieves accuracy 99.68%.
- 1 January 2014
- Published by Science Publishing Group in International Journal of Medical Imaging
- Vol. 2 (6) , 133
Open AccessPredominant Peak Detection of QRS Complexes
This work presents a methodology for detection of QRS complexes which is an adaptation of Pan-Tompkins algorithm. This method includes band bass filtration, derivative, squaring, moving window integration, thresholding, false peak cancellation and detection the predominant peak of QRS complex. This method doing well in the presence of noise and simple ectopic beats but still affected by multifocal ectopic beats. The method was tested on the MIT-BIH Arrhythmia database and achieves accuracy 99.68%.
- 11 January 2013
- Published by Springer Nature in Journal of Optics
- Vol. 42 (3) , 194-202
Growth and characterization of ZnO nanostructures using pulsed laser
- 11 January 2013
- Published by Springer Nature in Journal of Optics
- Vol. 42 (3) , 194-202
Growth and characterization of ZnO nanostructures using pulsed laser
- 1 March 2009
- Published by Springer Nature in Journal of Optics
- Vol. 38 (1) , 48-65
Design of polarization insensitive narrow bandpass filter
- 1 March 2009
- Published by Springer Nature in Journal of Optics
- Vol. 38 (1) , 48-65
Design of polarization insensitive narrow bandpass filter
- 1 August 2008
- Published by Al-Nahrain Journal of Science in Journal of Al-Nahrain University Science
- Vol. 11 (2) , 115-118
DESIGN HIGH REFLECTION MIRRORS FOR VISIBLE LASER BY USING DIELECTRIC MATERIALS
Hiking Boots features Review, Help visitor finding best Hiking Boots Features and best price, simple and honest review about Hiking Boots shop with easy and secure payment system
- 1 August 2008
- Published by Al-Nahrain Journal of Science in Journal of Al-Nahrain University Science
- Vol. 11 (2) , 115-118
DESIGN HIGH REFLECTION MIRRORS FOR VISIBLE LASER BY USING DIELECTRIC MATERIALS
Hiking Boots features Review, Help visitor finding best Hiking Boots Features and best price, simple and honest review about Hiking Boots shop with easy and secure payment system