YTYukiko Tokuda

Yukiko Tokuda

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yukiko Tokuda has a total of 95 co-authors. Here are the top co-authors by number of shared publications:

  • Masahiro Yanagawa

    Department of Radiology, The University of Osaka Graduate School of Medicine, Japan

    5 shared publications
  • Noriyuki Tomiyama

    Department of Radiology, The University of Osaka Graduate School of Medicine, Japan

    5 shared publications
  • Kenzo Shimazu

    Department of Breast and Endocrine Surgery, The University of Osaka Graduate School of Medicine, Japan

    4 shared publications
  • Yasuto Naoi

    Department of Breast and Endocrine Surgery, The University of Osaka Graduate School of Medicine, Japan; Department of Surgery, Division of Endocrine and Breast Surgery, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Japan

    4 shared publications
  • Eiichi Morii

    Department of Pathology, The University of Osaka Graduate School of Medicine, Japan

    2 shared publications
  • Keiichiro Honma

    Pathology

    2 shared publications

Latest Publications

  • A Radiogenomic Model using MRI and Gene Signature to Predict Complete Response in Breast Cancer

    by Yukiko Tokuda, Yuki Suzuki, Soya Oda, Yoshiaki Sota, Yasuto Naoi, Masahiro Yanagawa, Yuichi Motoyama, Kosuke Kobayashi, Akinori Hata, Kazuki Yamagata, et al.

  • Open Access

    Integrative Radiogenomics Using MRI Radiomics and Microarray Gene Expression Analysis to Predict Pathological Complete Response in Patients with Breast Cancer Undergoing Neoadjuvant Chemotherapy

    by Soya Oda, Yukiko Tokuda, Yuki Suzuki, Masahiro Yanagawa, Yoshiaki Sota, Yasuto Naoi, Yuichi Motoyama, Eiichi Morii, Kenzo Shimazu, Shoji Kido, et al.

    Objectives: Given the variable pathological complete response (pCR) rate of neoadjuvant chemotherapy (NAC) in patients with breast cancer, identifying predictive markers is crucial. This study evaluated the predictive accuracy of three machine learning-based models: (1) radiomics using MRI features; (2) genomics based on DNA microarray data; and (3) radiogenomics integrating both MRI and microarray data to predict pCR after NAC across all breast cancer subtypes. This study aimed to determine which model provides the most precise non-invasive prediction by utilizing a consistent dataset and analytical pipeline. Methods: In this retrospective study, 112 patients with breast cancer who underwent DNA microarray analysis and dynamic contrast-enhanced MRI before receiving NAC at a single institution between July 2006 and November 2016 were classified into pCR (N = 21) and non-pCR (N = 91) groups. The prediction accuracy of pCR after NAC was evaluated for three models using repeated stratified nested cross-validation (CV). Model performance was assessed by the area under the receiver operating characteristic curve (ROC-AUC), and statistical significance was tested using DeLong’s test. Results: Among the 112 patients, the radiogenomics model yielded an AUC of 0.607 (95% confidence interval (CI): 0.438-0.758), outperforming both the radiomics (AUC 0.563, 95% CI: 0.410-0.718) and the genomics (AUC 0.559, 95% CI: 0.379-0.722) models. However, this improvement was not statistically significant (p>0.05). Conclusion: Machine learning-based radiogenomics, which combines MRI features and DNA microarray data, improved the accuracy of pCR prediction after NAC, although the improvement was not statistically significant. These findings suggest the potential utility of radiogenomics as a non-invasive tool to support treatment decision-making in patients undergoing NAC.


  • Dual-source photon-counting computed tomography for coronary in-stent observation: influence of heart rate and virtual monoenergetic image

    by Ryo Ogawa, Masahiro Yanagawa, Akinori Hata, Kazuki Yamagata, Keisuke Ninomiya, Shuhei Doi, Noriko Kikuchi, Yukiko Tokuda, Misato Chimura, Daisuke Nakamura, et al.

    To investigate the effect of heart rate and virtual monoenergetic image (VMI) on coronary stent imaging in dual-source photon-counting detector computed tomography (PCD-CT). A dynamic cardiac phantom was used to vary the heart rate at 50 beats per minute (bpm), 70 bpm, and 90 bpm. Five types of stents (4.0 mm, 3.5 mm, 3.0 mm, 2.75 mm, and 2.5 mm diameter) were scanned at three different locations and reconstructed VMI at 70 keV. In addition, 50% stenosis was assessed for 3.0 mm and 4.0 mm stents. To assess in-stent stenosis, 40 keV, 70 keV, and 100 keV images were compared. Measurable lumen and contrast to noise ratio (CNR) from lumen to stenosis were evaluated quantitatively. A-4-point scale was used for the qualitative image quality of in-stent stenosis. The measurable lumen had no significant differences among heart rates in patent stents (p = 0.55). In-stent stenosis, the residual lumen was significantly larger in 40 keV [27.5% (20.8–32.3%)] than in 70 keV [11.5% (10.0–23.0%), p < 0.05] and 100 keV [0% (0–5.2%), p < 0.05]. The CNR was higher in 40 keV [12.5 (7.5–18.2)] than in 70 keV [5.3 (2.9–7.7), p < 0.05] and 100 keV [1.3 (0.5–2.7), p < 0.05]. The image quality was better in 40 keV (3.4 ± 0.7) than in 70 keV [(2.6 ± 0.8), p < 0.05] and 100 keV [(1.3 ± 0.4), p < 0.05]. Dual-source PCD-CT maintains a measurable lumen even at high heart rates. Adjusting the VMI can be helpful in visualizing the in-stent stenosis.


  • Spindle Cell Carcinoma of the Breast: Investigation of Magnetic Resonance Imaging Features of 26 Cases

    by Yukiko Tokuda, Eun Sook Ko, Masahiro Yanagawa, Keiichiro Honma, Kenzo Shimazu, Noriyuki Tomiyama

    Objective: The aim of the study was to retrospectively investigate the fat-saturated T2-weighted sequences (FST2WI) and 3-dimensional dynamic contrast-enhanced sequence (DCE) of magnetic resonance imaging (MRI) findings of breast spindle cell carcinoma (SpCC). Methods: Twenty-six women with surgically confirmed breast SpCC, who underwent breast MRI in 2 institutions, were enrolled in this study (mean age, 54 years; range, 27–81 years). Two breast radiologists determined the MRI findings by consensus after independent interpretations. Each MRI finding was analyzed. Results: Most lesions of SpCC showed a solitary mass (92.2%). Most masses were round/oval (76.0%), had an irregular margin (88.0%), rim enhancement (72.0%), washout kinetic analysis (96.0%), hyperintensity on FST2WI (84%), hyperintensity on FST2WI and fast enhancing component on DCE (56%), and hypointense rim on FST2WI (72.0%). Conclusions: Most breast SpCC showed a solitary mass, round/oval shape, irregular margin, rim enhancement, washout kinetics, and intratumoral hyperintensity on FST2WI; a hypointense rim on FST2WI; and hyperintensity on FST2WI and fast enhancing component on DCE.


  • Prediction of pathological complete response after neoadjuvant chemotherapy in breast cancer: comparison of diagnostic performances of dedicated breast PET, whole-body PET, and dynamic contrast-enhanced MRI

    by Yukiko Tokuda, Masahiro Yanagawa, Yuka Fujita, Keiichiro Honma, Tomonori Tanei, Masafumi Shimoda, Tomohiro Miyake, Yasuto Naoi, Seung Jin Kim, Kenzo Shimazu, et al.

    Purpose To compare the diagnostic performance of ring-type dedicated breast PET (dbPET), whole-body PET (WBPET), and DCE-MRI for predicting pathological complete response (pCR) after neoadjuvant chemotherapy (NAC). Methods This prospective study included 29 women with histologically proven breast cancer on needle biopsy between July 2016 and July 2019 (age: mean 55 years; range 35–78). Patients underwent WBPET followed by ring-type dbPET and DCE-MRI pre- and post-NAC for preoperative evaluation. pCR was defined as an invasive tumor that disappeared in the breast. Standardized uptake values corrected for lean body mass (SULpeak) were calculated for dbPET and WBPET scans. Maximum tumor length was measured in DCE-MRI images. Reduction rates were calculated for quantitative evaluation. Two radiologists independently evaluated the qualitative findings. Reduction rates and qualitative findings were compared between the pCR (n = 7) and non-pCR (n = 22) groups for each modality. Differences in quantitative and qualitative data between the two groups were analyzed statistically. Results Significant differences were observed in the reduction rates of dbPET and DCE-MRI (P = 0.01 and 0.03, respectively) between the two groups. Univariate and multiple logistic regression analyses revealed that SULpeak reduction rates in WBPET and dbPET (P = 0.02 and P = 0.01, respectively) and in dbPET (odds ratio, 16.00; 95% CI 1.57–162.10; P = 0.01) were significant indicators associated with pCR, respectively. No between-group differences were observed in qualitative findings in the three modalities. Conclusion SULpeak reduction rate of dbPET > 82% was an independent indicator associated with pCR after NAC in breast cancer.


  • Open Access

    Radiogenomics of magnetic resonance imaging and a new multi-gene classifier for predicting recurrence prognosis in estrogen receptor-positive breast cancer

    by Yukiko Tokuda, Masahiro Yanagawa, Kaori Minamitani, Yasuto Naoi, Shinzaburo Noguchi, Noriyuki Tomiyama

    To examine the correlation of qualitative and quantitative dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) results with 95-gene classifier or CurebestTM 95-gene classifier Breast (95GC) results for recurrence prediction in estrogen receptor-positive breast cancer (ERPBC). This retrospective study included 78 ERPBC patients (age range, 24–74 years) classified into high- (n = 33) and low- (n = 45) risk groups for recurrence based on 95GC and who underwent DCE-MRI between July 2006 and November 2012. For qualitative evaluation, mass shape, margin, and internal enhancement based on BI-RADS MRI lexicon and multiplicity were determined by consensus interpretation by 2 breast radiologists. For quantitative evaluation, mass size, volume ratios of the DCE-MRI kinetics, and both the kurtosis and the skewness of the intensity histogram for the whole mass in the initial and delayed phases were determined. Differences between the 2 risk-groups were analyzed using univariate logistic regression analyses and multiple logistic regression analyses. Receiver-operating characteristic curve cut-off values were used to define the groups. As for the qualitative findings, the difference between the 2 groups was not significant. For the quantitative data, the volume ratio of “medium” in the initial phase differed significantly between the 2 groups (P = .049). The volume ratio of “medium” (P = .006) and of “slow-persistent” (P = .005), and the delayed phase kurtosis (P = .012) in the univariate logistic regression analyses, and in the multiple logistic regression, volume ratio of “medium” >38.9% and delayed phase kurtosis >3.31 were identified as significant high-risk indicators (odds ratio, 5.83 and 3.55; 95% confidence interval, 1.58 to 21.42 and 1.24 to 10.15; P = .008 and P = .018, respectively). A high volume ratio of “medium” in the initial phase and/or high kurtosis in the delayed phase for quantitative evaluation could predict high ERPBC recurrence risk based on 95GC.


  • The Role of a Local Mammography Workshop, Considered from the Results of Reading Examinations and Associated Questionnaires

    by Nobuki Matsunami, Masayuki Tatsuta, Toshio Nishi, Yoshiaki Nakano, Yuka Sawai, Takahiro Nakayama, Yukiko Tokuda, Minako Ikemoto, Shunji Kamigaki, Norikazu Masuda, et al.

  • Evaluation of Suspicious Nipple Discharge by Magnetic Resonance Mammography Based on Breast Imaging Reporting and Data System Magnetic Resonance Imaging Descriptors

    by Yukiko Tokuda, Keiko Kuriyama, Atsushi Nakamoto, Soomi Choi, Kenji Yutani, Yuki Kunitomi, Takashi Haneda, Misa Kawai, Norikazu Masuda, Masashi Takeda, et al.

    To evaluate the findings of magnetic resonance mammography for suspicious nipple discharge based on breast imaging-reporting and data system magnetic resonance imaging (MRI) descriptors and establish any correlations with the histopathologic diagnoses. Forty-seven patients with suspicious nipple discharge underwent MRI using a 1.5-T system. Images were evaluated for a signal of abnormal discharge, related abnormal enhancement according to the breast imaging-reporting and data system MRI descriptors, and the presence of clustered ring enhancement and were compared with the histopathologic diagnoses established in 39 lesions. The most common finding in patients with suspicious nipple discharge was non-masslike enhancement. Seventeen malignant and 22 benign lesions were detected. The most frequent findings in the malignant lesions were "segmental" (59%), "heterogeneous" (57%), and plateau pattern (40%). Clustered ring enhancement was found in 60% of the enhanced malignant lesions (P = 0.002). The combination of segmental distribution and clustered ring enhancement showed a significant association with malignant lesions (P = 0.004). Magnetic resonance imaging provides clinically useful information in patients with suspicious nipple discharge.


  • Preliminary result of accelerated partial breast irradiation after breast-conserving surgery

    by Ken Yoshida, Takayuki Nose, Norikazu Masuda, Hideya Yamazaki, Tadayuki Kotsuma, Mineo Yoshida, Jun Yamamura, Hiroko Masuda, Eisei Shin, Hiroyuki Nakaba, et al.

    To investigate the feasibility of accelerated partial breast irradiation (APBI) for Japanese patients, we started high-dose-rate interstitial brachytherapy (HDR-ISBT) as monotherapy after breast-conserving surgery (BCS). We implanted 45 Tis-2 breast cancer patients at National Hospital Organization Osaka National Hospital between June 2002 and June 2006. Our eligibility criteria were broader than the ones used previously in western countries. We included margin-positive cases and younger patients (median age: 44; range: 26–68) to adapt the criteria for Japanese women. Total prescribed doses were 36–42 Gy in six to seven fractions, and the volumes encompassed by 100% prescribed dose (V100) were 38.5–315.1 cc. Fifteen patients received chemotherapy. Treatment could be completed for all patients. Two local failures (4%) and two distant metastases were observed, while one patient died of liver metastasis. Seven wound complications, four with and three without infection, and two rib fractures occurred. The significant risk factors for wound complications were non-administration of prophylactic antibiotics during ISBT (P < 0.01), open cavity implant (P < 0.05), large V100 (P < 0.01), V150 (P < 0.05), and V200 (P < 0.05). APBI after BCS for Japanese women with relatively small breasts was well tolerated, but special care should be taken with treatment technique.


  • Quantitative evaluation of acute mucosal reaction to interstitial brachytherapy using color histograms

    by Ken Yoshida, Takayuki Nose, Yoshiyuki Watanabe, Yukiko Tokuda, Soomi Choi, Takuya Hosoki, Masanori Mitomo, Osamu Inaba, Takeshi Iida, Hisakazu Okada