Johan Rens
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Johan Rens has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
Jan Desmet
Ghent University, Campus Kortrijk, Belgium
15 shared publications- Gerhard Botha
North-West University, Potchefstroom, South Africa
13 shared publications Brandon Peterson
Transmission Eskom SOC Ltd Johannesburg South Africa
8 shared publicationsDuan Serfontein
North-West University Potchefstroom, South Africa
5 shared publicationsAgknaton Bottenberg
Electrical Energy Laboratory, Ghent University, Sint-Pietersnieuwstraat 41, B-9000 Ghent, Belgium
4 shared publicationsColin Debruyne
Electrical Energy Laboratory, Ghent University, Sint-Pietersnieuwstraat 41, B-9000 Ghent, Belgium
4 shared publications
Latest Publications
- Open Access
- 19 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Access Journal of Power and Energy
- Vol. 10, 406-414
A Practical Solution for Locating the Source of Voltage Dips in HV/MV Interconnected Grids
Monitoring the technical performance of a power system is significantly enhanced when distributed instrumentation produces coherent field data, i.e., synchronized by GPS timestamping. In this paper a practical methodology is presented to improve the localisation of the source of a voltage dip on power grids. The proposed solution makes use of synchronised dip data provided by power quality meters. Field data reporting events occurred in an HV/MV interconnected system in South Africa are used to validate the results obtained by the improved method and compare with results of two alternative methods.
- 19 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Access Journal of Power and Energy
- Vol. 10, 406-414
Open AccessA Practical Solution for Locating the Source of Voltage Dips in HV/MV Interconnected Grids
Monitoring the technical performance of a power system is significantly enhanced when distributed instrumentation produces coherent field data, i.e., synchronized by GPS timestamping. In this paper a practical methodology is presented to improve the localisation of the source of a voltage dip on power grids. The proposed solution makes use of synchronised dip data provided by power quality meters. Field data reporting events occurred in an HV/MV interconnected system in South Africa are used to validate the results obtained by the improved method and compare with results of two alternative methods.
- 17 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-11
A Novel Extended Noninvasive Harmonic Resonance Detection Technique for Public Low-Voltage Networks
Harmonic resonance is increasingly observed in public low-voltage (LV) networks of central European countries. Adverse effects, such as harmonic disturbance amplification, can be caused by harmonic resonance, which necessitates and emphasizes the importance of their continuous monitoring and detection. This article proposes a noninvasive harmonic resonance detection technique for public LV networks that rely only on the measurement of voltage and current at the LV busbar. The proposed technique is formulated in three stages, each identifying a different characteristic of harmonic resonance: the presence of harmonic resonance, resonant harmonic order and bandwidth, and resonant intensity. The performance of each stage is first verified by extensive simulation. Then, using measurement data at three different LV networks, it is validated that the proposed technique can reliably track the three different characteristics of harmonic resonances accurately and continuously.
- 17 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-11
A Novel Extended Noninvasive Harmonic Resonance Detection Technique for Public Low-Voltage Networks
Harmonic resonance is increasingly observed in public low-voltage (LV) networks of central European countries. Adverse effects, such as harmonic disturbance amplification, can be caused by harmonic resonance, which necessitates and emphasizes the importance of their continuous monitoring and detection. This article proposes a noninvasive harmonic resonance detection technique for public LV networks that rely only on the measurement of voltage and current at the LV busbar. The proposed technique is formulated in three stages, each identifying a different characteristic of harmonic resonance: the presence of harmonic resonance, resonant harmonic order and bandwidth, and resonant intensity. The performance of each stage is first verified by extensive simulation. Then, using measurement data at three different LV networks, it is validated that the proposed technique can reliably track the three different characteristics of harmonic resonances accurately and continuously.
- Open Access
- 7 December 2018
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 13 (1) , 137-144
Power quality grid code compliance for renewable power plants in South Africa
The introduction of renewable generation to South Africa's grid has introduced challenges to the management and regulation of power quality (PQ). These have been addressed by establishing PQ compliance criteria in line with local circumstances and by the introduction of a Power Quality Guideline for renewable power plants (RPPs). A key challenge to RPPs has been meeting emission limits for harmonics. This has been addressed in South Africa's RPP Guideline by the development and introduction of a Group Harmonic Distortion limit which provides some flexibility to RPPs in making individual harmonic emission limits. The use of 95th percentile harmonic impedance envelopes is discussed and recommendations for impedance envelopes are made for different voltage levels within the South African Grid, based on actual network data. A lesson learnt is that using international standards and guidelines provides a starting point for compliance rules when introducing renewable generation. Developing countries that share economic and electricity network characteristics with South Africa should tailor the PQ rules and guidelines for RPPs to meet local conditions.
- 7 December 2018
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 13 (1) , 137-144
Open AccessPower quality grid code compliance for renewable power plants in South Africa
The introduction of renewable generation to South Africa's grid has introduced challenges to the management and regulation of power quality (PQ). These have been addressed by establishing PQ compliance criteria in line with local circumstances and by the introduction of a Power Quality Guideline for renewable power plants (RPPs). A key challenge to RPPs has been meeting emission limits for harmonics. This has been addressed in South Africa's RPP Guideline by the development and introduction of a Group Harmonic Distortion limit which provides some flexibility to RPPs in making individual harmonic emission limits. The use of 95th percentile harmonic impedance envelopes is discussed and recommendations for impedance envelopes are made for different voltage levels within the South African Grid, based on actual network data. A lesson learnt is that using international standards and guidelines provides a starting point for compliance rules when introducing renewable generation. Developing countries that share economic and electricity network characteristics with South Africa should tailor the PQ rules and guidelines for RPPs to meet local conditions.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
On the Remote Calibration of Voltage Transformers: Validation of Opportunity
Remote calibration of instrument transformers seems possible if sufficient certainty in field measurements can be achieved. This opportunity, until now, was only investigated from a theoretical point of view and in this paper, is now further investigated by using real-life synchrophasors. A transmission line is emulated, and voltage and current synchrophasors collected across the transmission line by two different synchrophasor recorders to derive a ratio correction factor for the remote instrument transformers.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
On the Remote Calibration of Voltage Transformers: Validation of Opportunity
Remote calibration of instrument transformers seems possible if sufficient certainty in field measurements can be achieved. This opportunity, until now, was only investigated from a theoretical point of view and in this paper, is now further investigated by using real-life synchrophasors. A transmission line is emulated, and voltage and current synchrophasors collected across the transmission line by two different synchrophasor recorders to derive a ratio correction factor for the remote instrument transformers.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 5, 1-6
Impact of Aggregation Interval on Harmonic Phase Angle Measurements
The aggregation principles of IEC 61000-4-30 is a well-known concept implemented in Power Quality (PQ) recorders. Only rms data is retained. Harmonic emission assessment requires the analysis of harmonic phasors. Continuous measurement of harmonic phasors is constrained by the volume of data resulting if the measurement period is longer. An innovative approach to also aggregate harmonic phase angles has been introduced and this paper evaluates how the aggregation interval affect the application of this concept in harmonic emission. Two different types of harmonic emission sources are evaluated in a distribution network. Results from this field data are used to demonstrate that although it is not possible to use a standard aggregation interval as in the IEC 61000-4-30, that the concept of aggregating harmonic phasors present an improved understanding of harmonic emission.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 5, 1-6
Impact of Aggregation Interval on Harmonic Phase Angle Measurements
The aggregation principles of IEC 61000-4-30 is a well-known concept implemented in Power Quality (PQ) recorders. Only rms data is retained. Harmonic emission assessment requires the analysis of harmonic phasors. Continuous measurement of harmonic phasors is constrained by the volume of data resulting if the measurement period is longer. An innovative approach to also aggregate harmonic phase angles has been introduced and this paper evaluates how the aggregation interval affect the application of this concept in harmonic emission. Two different types of harmonic emission sources are evaluated in a distribution network. Results from this field data are used to demonstrate that although it is not possible to use a standard aggregation interval as in the IEC 61000-4-30, that the concept of aggregating harmonic phasors present an improved understanding of harmonic emission.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Measurement Uncertainty of Current Harmonics During the Assessment of Compliance to Grid Code Requirements
This paper improves the impact of measurement uncertainty on harmonic grid code compliance assessment by characterization of the current transformers at a renewable power producer. Field data was collected to evaluate the CT ratio error for magnitude and phase angle up to the 60 th harmonic. The test setup made use of certified instruments and applied IEC standards to derive CT ratio correction factors per harmonic order and per CT to reduce the combined uncertainty of the measurement chain.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Measurement Uncertainty of Current Harmonics During the Assessment of Compliance to Grid Code Requirements
This paper improves the impact of measurement uncertainty on harmonic grid code compliance assessment by characterization of the current transformers at a renewable power producer. Field data was collected to evaluate the CT ratio error for magnitude and phase angle up to the 60 th harmonic. The test setup made use of certified instruments and applied IEC standards to derive CT ratio correction factors per harmonic order and per CT to reduce the combined uncertainty of the measurement chain.
- Open Access
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Network resonance detection using harmonic active power
Resonances in electrical distribution systems can result in amplification of harmonics, which is undesirable in electrical networks. To avoid intrusive measurement techniques, in the majority of the cases network modeling is used to validate if there is an issue with resonance. In this paper a new, innovative but simple, concept is presented which uses relatively basic measurements to segregate the power related to specific harmonics into active and non-active harmonic power. These results are subsequently used in order to find if there is resonance in the electrical network. In this paper the concepts are explained on a theoretical basis and are test cased by numerical modeling. The initial results look promising but additional research is needed to validate the method.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Open AccessNetwork resonance detection using harmonic active power
Resonances in electrical distribution systems can result in amplification of harmonics, which is undesirable in electrical networks. To avoid intrusive measurement techniques, in the majority of the cases network modeling is used to validate if there is an issue with resonance. In this paper a new, innovative but simple, concept is presented which uses relatively basic measurements to segregate the power related to specific harmonics into active and non-active harmonic power. These results are subsequently used in order to find if there is resonance in the electrical network. In this paper the concepts are explained on a theoretical basis and are test cased by numerical modeling. The initial results look promising but additional research is needed to validate the method.
- Open Access
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Harmonic impedance assessment using prevailing phasors
In accordance with the IEC 61000-3-6, the evaluation of the harmonic emissions requires an accurate harmonic impedance representation of the system. However, the assessment of a harmonic impedance is understood to be a very complex problem and that the available methods are not entirely satisfactory. Yet, utilities and other network users are expected to prove compliance to apportioned emission limits. To enable the online assessment of harmonic emissions, this paper proposes the use of prevailing phasors to enable the monitoring of the network's harmonic impedance. The proposed method has been validated using network simulations and practical measurements at a windfarm were used for offline assessments.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Open AccessHarmonic impedance assessment using prevailing phasors
In accordance with the IEC 61000-3-6, the evaluation of the harmonic emissions requires an accurate harmonic impedance representation of the system. However, the assessment of a harmonic impedance is understood to be a very complex problem and that the available methods are not entirely satisfactory. Yet, utilities and other network users are expected to prove compliance to apportioned emission limits. To enable the online assessment of harmonic emissions, this paper proposes the use of prevailing phasors to enable the monitoring of the network's harmonic impedance. The proposed method has been validated using network simulations and practical measurements at a windfarm were used for offline assessments.
- Open Access
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in SAIEE Africa Research Journal
- Vol. 108 (4) , 165-173
On Harmonic Emission Assessment: A Discriminative Approach
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in SAIEE Africa Research Journal
- Vol. 108 (4) , 165-173
Open AccessOn Harmonic Emission Assessment: A Discriminative Approach
- 1 December 2017
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 50 (2) , 233-234
WITHDRAWN: An Overview of the Application of Phasor Measurement Units (PMUs) and Network Coherent Data in an Interconnected Power Network: A Case for Namibia
- 1 December 2017
- Published by Elsevier in IFAC-PapersOnLine
- Vol. 50 (2) , 233-234
WITHDRAWN: An Overview of the Application of Phasor Measurement Units (PMUs) and Network Coherent Data in an Interconnected Power Network: A Case for Namibia