Minsheng Guan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Minsheng Guan has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
Hongbiao Du
7 shared publicationsJie Cui
7 shared publications- Hongbiao Du
College of Civil and Transportation Engineering, Shenzhen University, Shenzhen, China
5 shared publications - Qing Quan Liang
College of Sport, Health, and Engineering Victoria University Melbourne Victoria Australia
5 shared publications Haibo Jiang
School of Civil and Transportation Engineering, Guangdong University of Technology, Guangzhou, PR China
3 shared publicationsQingli Zeng
3 shared publications
Latest Publications
- 21 November 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Structural Stability and Dynamics
Seismic Simulation of Self-Slitting Squat Composite Shear Walls Incorporating Recycled Aggregate Concrete
A dual-function self-slitting recycled aggregate concrete squat composite shear wall with steel tubes (DF-SRAC-SCSW) is an efficient lateral load resisting system. In this system, the boundary elements are designed to provide both load-bearing capacity and self-slitting energy dissipation through the formation of controlled vertical slits under cyclic loading. This paper presents a numerical study on the seismic performance of squat composite shear walls constructed with recycled aggregate concrete and steel tubes. A three-dimensional Finite Element (FE) model is developed in ABAQUS, in which a proposed bond-slip constitutive model is used to simulate the bond-slip behavior between steel tubes and concrete. The validated FE model is employed to investigate the effects of axial compressive ratio, hoop spacing, yield strength of steel, steel content ratio, recycled concrete strength, shear span ratio, and steel tube arrangement on seismic performance. The results indicate that axial compressive ratio and shear span ratio are key factors governing seismic performance. Shear walls with high axial compressive ratios combined with low shear span ratios have a higher risk of brittle failure. Closely spaced hoops and higher steel content ratios improve confinement to the core RAC, thereby enhancing strength, stiffness, and energy dissipation. In addition, the number and distribution of steel tubes strongly influence seismic response, with a uniform distribution along the wall length providing the most favorable balance between slitting recycled aggregate concrete squat composite shear wall with steel tubes (DF-SRAC-SCSW) is an efficient lateral load resisting system. In this system, the boundary elements are designed to provide both load-bearing capacity and self-slitting energy dissipation through the formation of controlled vertical slits under cyclic loading. This paper presents a numerical study on the seismic performance of squat composite shear walls constructed with recycled aggregate concrete and steel tubes. A three-dimensional Finite Element (FE) model is developed in ABAQUS, in which a proposed bond–slip constitutive model is used to simulate the bond–slip behavior between steel tubes and concrete. The validated FE model is employed to investigate the effects of axial compressive ratio, hoop spacing, yield strength of steel, steel content ratio, recycled concrete strength, shear span ratio, and steel tube arrangement on seismic performance. The results indicate that axial compressive ratio and shear span ratio are key factors governing seismic performance. Shear walls with high axial compressive ratios combined with low shear span ratios have a higher risk of brittle failure. Closely spaced hoops and higher steel content ratios improve confinement to the core RAC, thereby enhancing strength, stiffness, and energy dissipationstrength, ductility, and energy dissipation. Design-oriented recommendations are proposed for DF-SRAC-SCSWs, offering practical guidelines for the seismic design of sustainable composite wall systems.
- 21 November 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Structural Stability and Dynamics
Seismic Simulation of Self-Slitting Squat Composite Shear Walls Incorporating Recycled Aggregate Concrete
A dual-function self-slitting recycled aggregate concrete squat composite shear wall with steel tubes (DF-SRAC-SCSW) is an efficient lateral load resisting system. In this system, the boundary elements are designed to provide both load-bearing capacity and self-slitting energy dissipation through the formation of controlled vertical slits under cyclic loading. This paper presents a numerical study on the seismic performance of squat composite shear walls constructed with recycled aggregate concrete and steel tubes. A three-dimensional Finite Element (FE) model is developed in ABAQUS, in which a proposed bond-slip constitutive model is used to simulate the bond-slip behavior between steel tubes and concrete. The validated FE model is employed to investigate the effects of axial compressive ratio, hoop spacing, yield strength of steel, steel content ratio, recycled concrete strength, shear span ratio, and steel tube arrangement on seismic performance. The results indicate that axial compressive ratio and shear span ratio are key factors governing seismic performance. Shear walls with high axial compressive ratios combined with low shear span ratios have a higher risk of brittle failure. Closely spaced hoops and higher steel content ratios improve confinement to the core RAC, thereby enhancing strength, stiffness, and energy dissipation. In addition, the number and distribution of steel tubes strongly influence seismic response, with a uniform distribution along the wall length providing the most favorable balance between slitting recycled aggregate concrete squat composite shear wall with steel tubes (DF-SRAC-SCSW) is an efficient lateral load resisting system. In this system, the boundary elements are designed to provide both load-bearing capacity and self-slitting energy dissipation through the formation of controlled vertical slits under cyclic loading. This paper presents a numerical study on the seismic performance of squat composite shear walls constructed with recycled aggregate concrete and steel tubes. A three-dimensional Finite Element (FE) model is developed in ABAQUS, in which a proposed bond–slip constitutive model is used to simulate the bond–slip behavior between steel tubes and concrete. The validated FE model is employed to investigate the effects of axial compressive ratio, hoop spacing, yield strength of steel, steel content ratio, recycled concrete strength, shear span ratio, and steel tube arrangement on seismic performance. The results indicate that axial compressive ratio and shear span ratio are key factors governing seismic performance. Shear walls with high axial compressive ratios combined with low shear span ratios have a higher risk of brittle failure. Closely spaced hoops and higher steel content ratios improve confinement to the core RAC, thereby enhancing strength, stiffness, and energy dissipationstrength, ductility, and energy dissipation. Design-oriented recommendations are proposed for DF-SRAC-SCSWs, offering practical guidelines for the seismic design of sustainable composite wall systems.
- 2 November 2026
- Published by Elsevier in Structures
- Vol. 94
Static-dynamic feature fusion for failure mode identification and hysteresis response prediction of shear walls
- 2 November 2026
- Published by Elsevier in Structures
- Vol. 94
Static-dynamic feature fusion for failure mode identification and hysteresis response prediction of shear walls
- 26 September 2026
- Published by Elsevier in Engineering Structures
- Vol. 369
Cyclic behavior and flexural-shear deformation mechanism of sea-sand concrete shear walls reinforced with steel-GFRP composite bars
- 26 September 2026
- Published by Elsevier in Engineering Structures
- Vol. 369
Cyclic behavior and flexural-shear deformation mechanism of sea-sand concrete shear walls reinforced with steel-GFRP composite bars
- Open Access
- 14 May 2026
- Published by Wiley in Structural Concrete
Behavior of manufactured sand and recycled coarse aggregate concrete‐filled steel tubular stub columns with circular section
Accelerated urbanization has intensified environmental concerns due to excessive natural resource consumption and construction waste generation. Circular concrete‐filled steel tube (CFST) columns incorporating manufactured sand recycled coarse aggregate (MS‐RCA) concrete have emerged as an innovative composite element offering notable environmental and economic benefits. To advance the use of MS‐RCA concrete in CFST structures, this paper presents experimental investigations into the behavior of 72 circular CFST stub columns constructed with MS‐RCA concrete. The effects of aggregate type, steel tube thickness, and stone powder content on structural response are examined. The results show that the failure modes of CFST columns with MS‐RCA concrete are characterized by local buckling and shear failure, similar to those of circular CFST columns with natural aggregate concrete. CFST columns with MS‐RCA have about 5.6% higher ultimate axial strength than those filled with natural sand‐RCA concrete. The inclusion of MS significantly enhances the ductility of CFST columns by an average of 34.6%, 25.4%, and 28.6% for steel tube thicknesses of 3.0, 3.5, and 4.0 mm, respectively. Moreover, for high‐strength concrete, the ultimate strength of columns filled with pebble MS‐RCA concrete is higher than that of those filled with limestone MS‐RCA concrete. Existing codes for CFST columns are evaluated and found to be highly conservative. Therefore, a new formula is proposed for CFST columns filled with MS‐RCA concrete and validated by experimental data. These findings confirm the viability of CFST columns with MS‐RCA concrete and highlight their potential to advance sustainable civil infrastructure.
- 14 May 2026
- Published by Wiley in Structural Concrete
Open AccessBehavior of manufactured sand and recycled coarse aggregate concrete‐filled steel tubular stub columns with circular section
Accelerated urbanization has intensified environmental concerns due to excessive natural resource consumption and construction waste generation. Circular concrete‐filled steel tube (CFST) columns incorporating manufactured sand recycled coarse aggregate (MS‐RCA) concrete have emerged as an innovative composite element offering notable environmental and economic benefits. To advance the use of MS‐RCA concrete in CFST structures, this paper presents experimental investigations into the behavior of 72 circular CFST stub columns constructed with MS‐RCA concrete. The effects of aggregate type, steel tube thickness, and stone powder content on structural response are examined. The results show that the failure modes of CFST columns with MS‐RCA concrete are characterized by local buckling and shear failure, similar to those of circular CFST columns with natural aggregate concrete. CFST columns with MS‐RCA have about 5.6% higher ultimate axial strength than those filled with natural sand‐RCA concrete. The inclusion of MS significantly enhances the ductility of CFST columns by an average of 34.6%, 25.4%, and 28.6% for steel tube thicknesses of 3.0, 3.5, and 4.0 mm, respectively. Moreover, for high‐strength concrete, the ultimate strength of columns filled with pebble MS‐RCA concrete is higher than that of those filled with limestone MS‐RCA concrete. Existing codes for CFST columns are evaluated and found to be highly conservative. Therefore, a new formula is proposed for CFST columns filled with MS‐RCA concrete and validated by experimental data. These findings confirm the viability of CFST columns with MS‐RCA concrete and highlight their potential to advance sustainable civil infrastructure.
- Open Access
- 17 April 2026
- Published by Elsevier in Engineering Structures
- Vol. 360
Experimental study of concrete-encased composite columns with GFRP-steel tubes filled with sea-sand concrete under cyclic loading
- 17 April 2026
- Published by Elsevier in Engineering Structures
- Vol. 360
Open AccessExperimental study of concrete-encased composite columns with GFRP-steel tubes filled with sea-sand concrete under cyclic loading
- Open Access
- 27 June 2025
- Published by Elsevier in Structures
- Vol. 79
Seismic performance of self-slitting composite shear walls with energy dissipation incorporating external O-connectors
- 27 June 2025
- Published by Elsevier in Structures
- Vol. 79
Open AccessSeismic performance of self-slitting composite shear walls with energy dissipation incorporating external O-connectors
- Open Access
- 6 May 2025
- Published by Elsevier in Structures
- Vol. 77
Experimental study on seismic behavior of self-slitting composite shear walls with external O-type dampers
- 6 May 2025
- Published by Elsevier in Structures
- Vol. 77
Open AccessExperimental study on seismic behavior of self-slitting composite shear walls with external O-type dampers
- 6 January 2022
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 20 (2) , 1169-1192
Seismic performance of innovative adaptive-slit composite structural walls with ultra-high axial compression ratio
- 6 January 2022
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 20 (2) , 1169-1192
Seismic performance of innovative adaptive-slit composite structural walls with ultra-high axial compression ratio
- 1 December 2020
- Published by Emerald Publishing in Magazine of Concrete Research
- Vol. 72 (24) , 1276-1288
Numerical analysis of limit states for circular concrete-filled steel tubular columns based on stiffness degradation
In this paper, the stiffness degradation index previously proposed by the authors is used as a seismic performance index for circular concrete-filled steel tubular (CFT) columns. Four performance levels for CFT columns are defined – that is, virtually intact; minor damage; moderate damage; and severe failure. A total of 144 CFT columns are numerically analysed to obtain the stiffness degradation index values for each performance level. The effects of several parameters (i.e. the axial compression ratio, slenderness ratio, diameter-to-thickness ratio, yield strength of a steel tube, and compressive strength of concrete cylinder) on the stiffness degradation index for each performance level are investigated. The results show that the axial compression ratio has a substantial effect on all performance levels; the diameter-to-thickness ratio has a significant effect on the virtually intact and minor damage performance levels; and the slenderness ratio has a significant effect on the moderate damage performance level. An equation that estimates the value of the performance level is proposed by the regression analysis and is further verified using existing experimental results. Based on parameter expansion analysis, the preliminary limit of the stiffness degradation index for each performance level is proposed.
- 1 December 2020
- Published by Emerald Publishing in Magazine of Concrete Research
- Vol. 72 (24) , 1276-1288
Numerical analysis of limit states for circular concrete-filled steel tubular columns based on stiffness degradation
In this paper, the stiffness degradation index previously proposed by the authors is used as a seismic performance index for circular concrete-filled steel tubular (CFT) columns. Four performance levels for CFT columns are defined – that is, virtually intact; minor damage; moderate damage; and severe failure. A total of 144 CFT columns are numerically analysed to obtain the stiffness degradation index values for each performance level. The effects of several parameters (i.e. the axial compression ratio, slenderness ratio, diameter-to-thickness ratio, yield strength of a steel tube, and compressive strength of concrete cylinder) on the stiffness degradation index for each performance level are investigated. The results show that the axial compression ratio has a substantial effect on all performance levels; the diameter-to-thickness ratio has a significant effect on the virtually intact and minor damage performance levels; and the slenderness ratio has a significant effect on the moderate damage performance level. An equation that estimates the value of the performance level is proposed by the regression analysis and is further verified using existing experimental results. Based on parameter expansion analysis, the preliminary limit of the stiffness degradation index for each performance level is proposed.
- 1 October 2020
- Published by Elsevier in Engineering Structures
- Vol. 221
Experimental investigation of axial loaded circular steel tube short columns filled with manufactured sand concrete
- 1 October 2020
- Published by Elsevier in Engineering Structures
- Vol. 221
Experimental investigation of axial loaded circular steel tube short columns filled with manufactured sand concrete