Mohamed Mahmoud Gouda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mohamed Mahmoud Gouda has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Christopher P. Underwood
School of the Built and Natural Environment, University of Northumbria, Newcastle upon Tyne NE1 8ST, UK
6 shared publications S. Danaher
School of Engineering, University of Northumbria, Newcastle upon Tyne, NE1 8ST, UK
4 shared publicationsS Danaher
School of Engineering, Northumbria University, Newcastle upon Tyne, UK
2 shared publications- Fatma M. Refaat
Department of Electronic Technology, Faculty of Technology and Education, Helwan University, Cairo, Egypt
1 shared publication - Hilmy Awad
Department of Electrical Technology, Faculty of Technology and Education, Helwan University, El-Sawah, Cairo 11813, Egypt
1 shared publication Mohamed A. El-Brawany
Faculty of Electronics Engineering, Department of Industrial Electronics and Control Engineering, Menoufia University, Shebin El Kom, Egypt
1 shared publication
Latest Publications
- 1 August 2024
- Published by Taylor & Francis in Journal of Control and Decision
- p. 1-18
Enhancement of unbalanced robot performance using fuzzy sliding mode control
- 1 August 2024
- Published by Taylor & Francis in Journal of Control and Decision
- p. 1-18
Enhancement of unbalanced robot performance using fuzzy sliding mode control
- Open Access
- 20 December 2022
- Published by Oriental Scientific Publishing Company in Biomedical and Pharmacology Journal
- Vol. 15 (4) , 2381-2397
Detection and Classification of Brain Tumor Using Machine Learning Algorithms
The brain is the organ that controls the activities of all parts of the body. The tumor is familiar as an irregular outgrowth of tissue. Brain tumors are an abnormal lump of tissue in which cells grow up and redouble uncontrollably. It is categorized into different types based on their nature, origin, growth rate, and stage of progress. Detection of the tumor by traditional methods is time-consuming and does not widen to diagnose a large amount of data and is less accurate. So, the automatic diagnosis of the tumors in the brain by magnetic resonance imaging (MRI) plays a very important role in computer-aided diagnosis. This paper concentrates on the diagnosis of three kinds of brain tumors (a meningioma, a glioma, and a pituitary tumor). Machine learning algorithms: KNN, SVM, and GRNN are suggested to increase accuracy and reduce diagnostic time by using a publicly available dataset, features that are extracted of images, data pre-processing methods, and the principal component analysis (PCA). This paper aims to minimize the training time of the suggested algorithms. The dimensionality reducing technique is applied to the dataset and diagnosis using machine learning algorithms, such as Support Vector Machines (SVM), K-Nearest Neighbor (KNN), and Generalized Regression Neural Networks (GRNN). The accuracies of the algorithms used in diagnosing tumors are 97%, 96.24%, and 94.7% for KNN, SVM, and GRNN, respectively. The KNN is therefore regarded as the algorithm of choice.
- 20 December 2022
- Published by Oriental Scientific Publishing Company in Biomedical and Pharmacology Journal
- Vol. 15 (4) , 2381-2397
Open AccessDetection and Classification of Brain Tumor Using Machine Learning Algorithms
The brain is the organ that controls the activities of all parts of the body. The tumor is familiar as an irregular outgrowth of tissue. Brain tumors are an abnormal lump of tissue in which cells grow up and redouble uncontrollably. It is categorized into different types based on their nature, origin, growth rate, and stage of progress. Detection of the tumor by traditional methods is time-consuming and does not widen to diagnose a large amount of data and is less accurate. So, the automatic diagnosis of the tumors in the brain by magnetic resonance imaging (MRI) plays a very important role in computer-aided diagnosis. This paper concentrates on the diagnosis of three kinds of brain tumors (a meningioma, a glioma, and a pituitary tumor). Machine learning algorithms: KNN, SVM, and GRNN are suggested to increase accuracy and reduce diagnostic time by using a publicly available dataset, features that are extracted of images, data pre-processing methods, and the principal component analysis (PCA). This paper aims to minimize the training time of the suggested algorithms. The dimensionality reducing technique is applied to the dataset and diagnosis using machine learning algorithms, such as Support Vector Machines (SVM), K-Nearest Neighbor (KNN), and Generalized Regression Neural Networks (GRNN). The accuracies of the algorithms used in diagnosing tumors are 97%, 96.24%, and 94.7% for KNN, SVM, and GRNN, respectively. The KNN is therefore regarded as the algorithm of choice.
- 1 July 2020
- Published by Egyptian Knowledge Bank in ERJ. Engineering Research Journal
- Vol. 43 (3) , 169-183
Performance Optimization of Brushless DC Motors for the Mitigation of Voltage Dips, Swells and Short Interruptions in Weak Grids
Normally, the BLDC motor drives a sensitive load which is severely influenced by such disturbances. The main aim of this work is to investigate the performance of BLDC motors when they are tied to weak grids. Thus, this paper presents a study on the performance of the BLDC motor under disturbed utility conditions and implements an efficient solution in order to guarantee a soft operation in the case that a BLDC drives a sensitive load. A buck-boost DC converter is merged with the BLDC drive inverter in order to be able to mitigate voltage dips as well as voltage swells. A short interruption of one or two phases of the grid voltage can also be mitigated. The BLDC motor is controlled via cascade PI-controller layout that has an outer loop for the speed control and inner loop for the DC voltage control. The PI controllers’ gains are optimized by using the ant-colony optimization technique and then implemented in a simulation model using MATLAB/SIMULINK. Six cases of disturbances have been simulated including balanced and unbalanced dips, swells and short interruption of one or two phases of the grid. Simulation results with various disturbances show the ability of the proposed controller to mitigate the grid disturbances with good transient and steady-state responses.
- 1 July 2020
- Published by Egyptian Knowledge Bank in ERJ. Engineering Research Journal
- Vol. 43 (3) , 169-183
Performance Optimization of Brushless DC Motors for the Mitigation of Voltage Dips, Swells and Short Interruptions in Weak Grids
Normally, the BLDC motor drives a sensitive load which is severely influenced by such disturbances. The main aim of this work is to investigate the performance of BLDC motors when they are tied to weak grids. Thus, this paper presents a study on the performance of the BLDC motor under disturbed utility conditions and implements an efficient solution in order to guarantee a soft operation in the case that a BLDC drives a sensitive load. A buck-boost DC converter is merged with the BLDC drive inverter in order to be able to mitigate voltage dips as well as voltage swells. A short interruption of one or two phases of the grid voltage can also be mitigated. The BLDC motor is controlled via cascade PI-controller layout that has an outer loop for the speed control and inner loop for the DC voltage control. The PI controllers’ gains are optimized by using the ant-colony optimization technique and then implemented in a simulation model using MATLAB/SIMULINK. Six cases of disturbances have been simulated including balanced and unbalanced dips, swells and short interruption of one or two phases of the grid. Simulation results with various disturbances show the ability of the proposed controller to mitigate the grid disturbances with good transient and steady-state responses.
- 1 December 2006
- Published by Elsevier in Building and Environment
- Vol. 41 (12) , 1881-1891
Quasi-adaptive fuzzy heating control of solar buildings
- 1 December 2006
- Published by Elsevier in Building and Environment
- Vol. 41 (12) , 1881-1891
Quasi-adaptive fuzzy heating control of solar buildings
- 28 April 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 602-606
Intelligent Speed Control of Permanent Magnet Synchronous Motor Drive Based-on Neuro-Fuzzy Approach
This paper presents speed control system for permanent magnet synchronous motor (PMSM) drive, which newly incorporates adaptive neuro-fuzzy with two input variables and one control output variable. This control methodology solves the problem of nonlinearities and parameter variations of PMSM drive. Moreover, it achieves high dynamic performance and accurate speed tracking control with good steady-state characteristics. Firstly, a neural network-based architecture is described for fuzzy logic control. The specified rules and their membership functions of fuzzy systems are represented as the processing nodes in the neural network structure. Then, the fuzzy rules and the membership functions are tuned by the supervised gradient decent learning algorithm. The performance of the proposed controller is evaluated under various operating conditions. The controller is shown to be robust, inherently adaptive in nature, and capable of learning. Results demonstrate the efficacy of the control system
- 28 April 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 602-606
Intelligent Speed Control of Permanent Magnet Synchronous Motor Drive Based-on Neuro-Fuzzy Approach
This paper presents speed control system for permanent magnet synchronous motor (PMSM) drive, which newly incorporates adaptive neuro-fuzzy with two input variables and one control output variable. This control methodology solves the problem of nonlinearities and parameter variations of PMSM drive. Moreover, it achieves high dynamic performance and accurate speed tracking control with good steady-state characteristics. Firstly, a neural network-based architecture is described for fuzzy logic control. The specified rules and their membership functions of fuzzy systems are represented as the processing nodes in the neural network structure. Then, the fuzzy rules and the membership functions are tuned by the supervised gradient decent learning algorithm. The performance of the proposed controller is evaluated under various operating conditions. The controller is shown to be robust, inherently adaptive in nature, and capable of learning. Results demonstrate the efficacy of the control system
- 10 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 07431619,p. 507-512
Fuzzy ventilation control for zone temperature and relative humidity
Many nondomestic and domestic buildings, built around the world, use natural means to provide ventilation for indoor air quality and thermal comfort. The fuzzy ventilation control strategy aims to use the free cooling and dehumidification available due to differences in zone and ambient conditions. This can be achieve by changing the proportion of fresh air entering the heating, ventilation and air conditioning (HVAC) system and hence the controlled zone. The fuzzy ventilation controllers also aim to maintain the zone conditions at a preferred set point which lies between the upper and lower set points. The upper and lower set point limits and the preferred set point for fuzzy ventilation control purposes are set to ensure occupant comfort. Hence when the fuzzy ventilation control strategy is not capable of maintaining the zone conditions within the upper and lower set-point limits the HVAC plant become active. Simulations results using the fuzzy ventilation control strategy are compared with normal plant considering PID controllers with upper and lower set point limits for each controlled parameter. This benchmark comparison is used to assess the benefits of using the fuzzy ventilation control strategy.
- 10 August 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 07431619,p. 507-512
Fuzzy ventilation control for zone temperature and relative humidity
Many nondomestic and domestic buildings, built around the world, use natural means to provide ventilation for indoor air quality and thermal comfort. The fuzzy ventilation control strategy aims to use the free cooling and dehumidification available due to differences in zone and ambient conditions. This can be achieve by changing the proportion of fresh air entering the heating, ventilation and air conditioning (HVAC) system and hence the controlled zone. The fuzzy ventilation controllers also aim to maintain the zone conditions at a preferred set point which lies between the upper and lower set points. The upper and lower set point limits and the preferred set point for fuzzy ventilation control purposes are set to ensure occupant comfort. Hence when the fuzzy ventilation control strategy is not capable of maintaining the zone conditions within the upper and lower set-point limits the HVAC plant become active. Simulations results using the fuzzy ventilation control strategy are compared with normal plant considering PID controllers with upper and lower set point limits for each controlled parameter. This benchmark comparison is used to assess the benefits of using the fuzzy ventilation control strategy.
- 1 November 2003
- Published by SAGE Publications in Building Services Engineering Research & Technology
- Vol. 24 (4) , 271-280
Modelling the robustness properties of HVAC plant under feedback control
Most existing building simulation programs fail to capture sufficient of the underlying dynamics of nonlinear HVAC plant and some have restricted room space modelling capabilities for low-time-horizon analyses. In this work, a simplified model of a room space with hot water heating and a chilled ceiling system is developed for the main purpose of analysing control system response. The room model is based on a new approach to lumped capacitance modelling and the heating and chilled ceiling emitters are modelled using third-order descriptions. Control system components are treated in detail and both controllers are ‘tuned' at a nominal region of plant operation using a gradient-descent-based optimization procedure. Robustness qualities of the controllers are analysed with reference to extremes in plant operating conditions. A key feature of the work is the transparency of the modelling procedure, designed to have appeal to researchers as well as practitioners involved with HVAC control system design problems.
- 1 November 2003
- Published by SAGE Publications in Building Services Engineering Research & Technology
- Vol. 24 (4) , 271-280
Modelling the robustness properties of HVAC plant under feedback control
Most existing building simulation programs fail to capture sufficient of the underlying dynamics of nonlinear HVAC plant and some have restricted room space modelling capabilities for low-time-horizon analyses. In this work, a simplified model of a room space with hot water heating and a chilled ceiling system is developed for the main purpose of analysing control system response. The room model is based on a new approach to lumped capacitance modelling and the heating and chilled ceiling emitters are modelled using third-order descriptions. Control system components are treated in detail and both controllers are ‘tuned' at a nominal region of plant operation using a gradient-descent-based optimization procedure. Robustness qualities of the controllers are analysed with reference to extremes in plant operating conditions. A key feature of the work is the transparency of the modelling procedure, designed to have appeal to researchers as well as practitioners involved with HVAC control system design problems.
- 1 December 2002
- Published by Elsevier in Building and Environment
- Vol. 37 (12) , 1255-1265
Building thermal model reduction using nonlinear constrained optimization
- 1 December 2002
- Published by Elsevier in Building and Environment
- Vol. 37 (12) , 1255-1265
Building thermal model reduction using nonlinear constrained optimization
- 1 September 2002
- Published by Taylor & Francis in Mathematical and Computer Modelling of Dynamical Systems
- Vol. 8 (3) , 333-344
Application of an Artificial Neural Network for Modelling the Thermal Dynamics of a Building?s Space and its Heating System
Artificial neural networks (ANNs) have been used for modelling the thermal dynamics of a building’s space, its water heating system and the influence of solar radiation. A multi-layer feed-forward neural network, using a Levenberg-Marquardt backpropagation-training algorithm, has been applied to predict the future internal temperature. Real weather data for a number of winter months, together with a validated building model (based on the building constructions data), were used to train the network in order to generate a mapping between the easily measurable inputs (outdoor temperature, solar irradiance, heating valve position and the building indoor temperature) and the desired output, i.e., the predicted indoor temperature. The objective of this work was to investigate the potential of using an ANN with singular value decomposition method (SVD) to predict the indoor temperature to shut down the heating system controller early for saving the energy consumption for heating inside the building.
- 1 September 2002
- Published by Taylor & Francis in Mathematical and Computer Modelling of Dynamical Systems
- Vol. 8 (3) , 333-344
Application of an Artificial Neural Network for Modelling the Thermal Dynamics of a Building?s Space and its Heating System
Artificial neural networks (ANNs) have been used for modelling the thermal dynamics of a building’s space, its water heating system and the influence of solar radiation. A multi-layer feed-forward neural network, using a Levenberg-Marquardt backpropagation-training algorithm, has been applied to predict the future internal temperature. Real weather data for a number of winter months, together with a validated building model (based on the building constructions data), were used to train the network in order to generate a mapping between the easily measurable inputs (outdoor temperature, solar irradiance, heating valve position and the building indoor temperature) and the desired output, i.e., the predicted indoor temperature. The objective of this work was to investigate the potential of using an ANN with singular value decomposition method (SVD) to predict the indoor temperature to shut down the heating system controller early for saving the energy consumption for heating inside the building.
- 1 November 2001
- Published by SAGE Publications in Building Services Engineering Research & Technology
- Vol. 22 (4) , 237-253
Thermal comfort based fuzzy logic controller
Most heating, ventilation and air conditioning (HVAC) control systems are considered as temperature control problems. In this work, the predicted mean vote (PMV) is used to control the indoor temperature of a space by setting it at a point where the PMV index becomes zero and the predicted percentage of persons dissatisfied (PPD) achieves a maximum threshold of 5%. This is achieved through the use of a fuzzy logic controller that takes into account a range of human comfort criteria in the formulation of the control action that should be applied to the heating system to bring the space to comfort conditions. The resulting controller is free of the set up and tuning problems that hinder conventional HVAC controllers. Simulation results show that the proposed control strategy makes it possible to maximize the indoor thermal comfort and, correspondingly, a reduction in energy use of 20% was obtained for a typical 7-day winter period when compared with conventional control.
- 1 November 2001
- Published by SAGE Publications in Building Services Engineering Research & Technology
- Vol. 22 (4) , 237-253
Thermal comfort based fuzzy logic controller
Most heating, ventilation and air conditioning (HVAC) control systems are considered as temperature control problems. In this work, the predicted mean vote (PMV) is used to control the indoor temperature of a space by setting it at a point where the PMV index becomes zero and the predicted percentage of persons dissatisfied (PPD) achieves a maximum threshold of 5%. This is achieved through the use of a fuzzy logic controller that takes into account a range of human comfort criteria in the formulation of the control action that should be applied to the heating system to bring the space to comfort conditions. The resulting controller is free of the set up and tuning problems that hinder conventional HVAC controllers. Simulation results show that the proposed control strategy makes it possible to maximize the indoor thermal comfort and, correspondingly, a reduction in energy use of 20% was obtained for a typical 7-day winter period when compared with conventional control.