HHHugo Layard Horsfall

Hugo Layard Horsfall

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hugo Layard Horsfall has a total of 411 co-authors. Here are the top co-authors by number of shared publications:

  • Hani J. Marcus

    Department of Neurosurgery, National Hospital for Neurology and Neurosurgery, Victor Horsley, UCL Queen Square Institute of Neurology, University College London, London, UK

    12 shared publications
  • Danyal Zaman Khan

    Dept of Translational Neuroscience and Stroke, UCL Queen Square Institute of Neurology, University College London, London, UK

    9 shared publications
  • Hani J. Marcus

    Department of Neurosurgery, National Hospital for Neurology and Neurosurgery, London, UK; Wellcome / EPSRC Centre for Interventional and Surgical Sciences, University College London, London, UK

    9 shared publications
  • William Muirhead

    Victor Horsley Department of Neurosurgery, The National Hospital for Neurology and Neurosurgery, University College London NHS Trust, London, United Kingdom

    9 shared publications
  • Danail Stoyanov

    Wellcome / EPSRC Centre for Interventional and Surgical Sciences, University College London, London, UK; Digital Surgery Ltd, Medtronic, London, UK

    7 shared publications
  • Chan Hee Koh

    Department of Neurosurgery, National Hospital for Neurology and Neurosurgery, London, UK; Wellcome / EPSRC Centre for Interventional and Surgical Sciences, University College London, London, UK

    6 shared publications

Latest Publications

  • Open Access

    Recalibration of implantable brain–computer interfaces to enable long-term independent use–a systematic review

    by Eleanor Swanson, Esmee Dohle, Luke Bashford, Hugo Layard Horsfall, Luka Jovanovic, William R Muirhead, Jamie F M Brannigan

    Background. Implantable brain–computer interfaces (iBCIs) decode neural signals to generate command signals for effector devices to restore lost functions, such as movement or speech. However, maintaining device performance over time requires recalibration of decoding algorithms due to inherent instability in neural signals. Objective. To systematically review recalibration procedures in iBCIs for patients with motor impairments, focusing on the clinical implications of recalibration requirements and strategies which can enable long-term, independent use. Approach. A systematic search was conducted across EMBASE, MEDLINE, and CINAHL databases to identify studies involving recalibration of iBCIs. Data on recalibration frequency, duration, staff requirements, and location were extracted and analyzed. Main results. Recalibration practices varied widely amongst studies and were typically performed according to predetermined study protocols, rather than practical need following deteriorating device performance. Common practices include manual recalibration requiring a specialist research team, semi-automatic recalibration which could be performed by a non-specialist caregiver, and automatic recalibration methods whereby patients did not require assistance. Devices utilizing electrocorticography (ECoG) recording arrays generally required less frequent recalibration compared to those using microelectrode arrays (MEAs). Extended independent use was more frequently reported with ECoG-based iBCIs. Significance. Reducing recalibration frequency or complexity can improve patient autonomy, which is crucial for enhancing long-term independent iBCI use in home and clinical settings. ECoG iBCIs typically have a low recalibration burden due to inherent signal stability. Conversely, MEA iBCIs typically involve a higher recalibration burden, though recent studies have reduced this by incorporating spectral data and continuously updating models. Despite this progress, recalibration procedures are often not fully defined in iBCI studies, and where they are, they usually relate to the study protocol rather than the clinically meaningful recalibration requirement due to worsening device performance. Future studies should continue to develop user-friendly recalibration procedures and outline the clinically relevant recalibration requirements where possible.


  • Open Access

    A clinically integrated, frameless human Neuropixels workflow

    by Hugo Layard Horsfall, Ahmed K Toma, Laurence Watkins, Harith Akram, Hani J Marcus, Ainsley Stewart, Jake Chatburn, Anne Vanhoestenberghe, Brian F Coughlin, Angelique C Paulk, et al.

    High-density electrophysiological recording with Neuropixels probes enables single-unit resolution of human neural activity, but integration into routine clinical environments remains challenging and reported recordings have been limited to a few US centres. Here, we present a reproducible roadmap for human Neuropixels recordings under a nationally managed regulatory framework in the United Kingdom. Guided by the IDEAL Stage 2a (Development) framework, we established a frameless intraoperative workflow using manufacturer-sterilised probes and a commercially available, clinical-grade setup. We prospectively evaluated this workflow in six participants (mean age 62.5 years) undergoing elective ventriculoperitoneal shunt surgery, assessed across three predefined endpoints: clinical safety, procedural timing, and neural data yield. Iterative failure-mitigation cycles resolved key technical barriers, including neuronavigation interference and hardware instability. The workflow achieved zero research-related adverse events, maintained a 30-minute procedural extension, and progressively increased single-unit yield to 146 manually curated units.

  • Open Access

    Automated Operative Phase and Step Recognition in Vestibular Schwannoma Surgery: Development and Preclinical Evaluation of a Deep Learning Neural Network (IDEAL Stage 0)

    by Simon C. Williams, Dorothée Duvaux, Adrito Das, Siddharth Sinha, Hugo Layard Horsfall, Jonathan P. Funnell, John G. Hanrahan, Danyal Z. Khan, William Muirhead, Neil Kitchen, et al.

    BACKGROUND AND OBJECTIVES: Machine learning (ML) in surgical video analysis offers promising prospects for training and decision support in surgery. The past decade has seen key advances in ML-based operative workflow analysis, though existing applications mostly feature shorter surgeries (5 hours duration), data-heavy surgeries, using VS resection as an exemplar. METHODS: A video dataset of 21 microscopic retrosigmoid VS resections was collected at a single institution over 3 years and underwent workflow annotation according to a previously agreed expert consensus (Approach, Excision, and Closure phases; and Debulking or Dissection steps within the Excision phase). Annotations were used to train a ML model consisting of a convolutional neural network and a recurrent neural network. 5-fold cross-validation was used, and performance metrics (accuracy, precision, recall, F1 score) were assessed for phase and step prediction. RESULTS: Median operative video time was 5 hours 18 minutes (IQR 3 hours 21 minutes-6 hours 1 minute). The “Tumor Excision” phase accounted for the majority of each case (median 4 hours 23 minutes), whereas “Approach and Exposure” (28 minutes) and “Closure” (17 minutes) comprised shorter phases. The ML model accurately predicted operative phases (accuracy 81%, weighted F1 0.83) and dichotomized steps (accuracy 86%, weighted F1 0.86). CONCLUSION: This study demonstrates that our ML model can accurately predict the surgical phases and intraphase steps in retrosigmoid VS resection. This demonstrates the successful application of ML in operative workflow recognition on low-volume, lengthy, data-heavy surgical videos. Despite this, there remains room for improvement in individual step classification. Future applications of ML in low-volume high-complexity operations should prioritize collaborative video sharing to overcome barriers to clinical translation.


  • Open Access

    Video-Based Performance Analysis in Pituitary Surgery - Part 2: Artificial Intelligence Assisted Surgical Coaching

    by Danyal Z. Khan, Nicola Newall, Chan Hee Koh, Adrito Das, Sanchit Aapan, Hugo Layard Horsfall, Stephanie E. Baldeweg, Sophia Bano, Anouk Borg, Aswin Chari, et al.


  • Open Access

    Video-Based Performance Analysis in Pituitary Surgery—Part 1: Surgical Outcomes

    by Danyal Z. Khan, Chan Hee Koh, Adrito Das, Alexandra Valetopolou, John G. Hanrahan, Hugo Layard Horsfall, Stephanie E. Baldeweg, Sophia Bano, Anouk Borg, Neil L. Dorward, et al.


  • Open Access

    Author Correction: The IDEAL framework for surgical robotics: development, comparative evaluation and long-term monitoring

    by Hani J. Marcus, Pedro T. Ramirez, Danyal Z. Khan, Hugo Layard Horsfall, John G. Hanrahan, Simon C. Williams, David J. Beard, Rani Bhat, Ken Catchpole, Andrew Cook, et al.


  • Top Cited Papers
    Open Access

    The IDEAL framework for surgical robotics: development, comparative evaluation and long-term monitoring

    by Hani J. Marcus, Pedro T. Ramirez, Danyal Z. Khan, Hugo Layard Horsfall, John G. Hanrahan, Simon C. Williams, David J. Beard, Rani Bhat, Ken Catchpole, Andrew Cook, et al.

    The next generation of surgical robotics is poised to disrupt healthcare systems worldwide, requiring new frameworks for evaluation. However, evaluation during a surgical robot’s development is challenging due to their complex evolving nature, potential for wider system disruption and integration with complementary technologies like artificial intelligence. Comparative clinical studies require attention to intervention context, learning curves and standardized outcomes. Long-term monitoring needs to transition toward collaborative, transparent and inclusive consortiums for real-world data collection. Here, the Idea, Development, Exploration, Assessment and Long-term monitoring (IDEAL) Robotics Colloquium proposes recommendations for evaluation during development, comparative study and clinical monitoring of surgical robots—providing practical recommendations for developers, clinicians, patients and healthcare systems. Multiple perspectives are considered, including economics, surgical training, human factors, ethics, patient perspectives and sustainability. Further work is needed on standardized metrics, health economic assessment models and global applicability of recommendations.


  • Open Access

    Skull Base Repair following Resection of Vestibular Schwannoma: A Systematic Review (Part 1: The Retrosigmoid Approach)

    by Joachim Starup-Hansen, Simon C. Williams, Alexandra Valetopoulou, Danyal Z. Khan, Hugo Layard Horsfall, Jigishaa Moudgil-Joshi, Oliver Burton, Hala Kanona, Shakeel R. Saeed, William Muirhead, et al.

    Objective Despite advances in skull-base reconstruction techniques, cerebrospinal fluid (CSF) leaks remain a common complication following retrosigmoid (RS) vestibular schwannoma (VS) surgery. We aimed to review and classify the available strategies used to prevent CSF leaks following RS VS surgery. Methods A systematic review, including studies of adults undergoing RS VS surgery since 2000, was conducted. Repair protocols were synthesized into a narrative summary, and a taxonomic classification of techniques and materials was produced. Additionally, the advantages, disadvantages, and associated CSF leak rates of different repair protocols were described. Results All 42 studies were case series, of which 34 were retrospective, and eight were prospective. Repair strategies included heterogeneous combinations of autografts, xenografts, and synthetic materials. A repair taxonomy was produced considering seven distinct stages to CSF leak prevention, including intraoperative approaches to the dura, internal auditory canal (IAC), air cells, RS bony defect, extracranial soft tissue, postoperative dressings, and CSF diversion. Notably, there was significant heterogeneity among institutions, particularly in the dural and IAC stages. The median postoperative incidence of CSF leaks was 6.3% (IQR: 1.3–8.44%). Conclusions The intraoperative strategies used to prevent CSF leaks during RS VS surgery vary between and within institutions. As a result of this heterogeneity and inconsistent reporting of CSF leak predictive factors, a meaningful comparative analysis of repair protocols was not feasible. Instead, we propose the development of a prospective multicenter observational evaluation designed to accurately capture a comprehensive dataset of potential CSF risk factors, including all stages of the operative repair protocol. * Equal senior authorship. Received: 05 September 2023 Accepted: 25 November 2023 Accepted Manuscript online: 04 December 2023 Article published online: 22 January 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany


  • Open Access

    Skull Base Repair following Resection of Vestibular Schwannoma: A Systematic Review (Part 2: The Translabyrinthine Approach)

    by Joachim Starup-Hansen, Simon C. Williams, Alexandra Valetopoulou, Danyal Z. Khan, Hugo Layard Horsfall, Jigishaa Moudgil-Joshi, Oliver Burton, Hala Kanona, Shakeel R. Saeed, William Muirhead, et al.

    Objectives Despite advances in skull base reconstruction techniques, cerebrospinal fluid (CSF) leaks remain a relatively common complication after translabyrinthine (TL) vestibular schwannoma (VS) surgery. We conducted a systematic review to synthesize the repair techniques and materials used in TL VS surgery to prevent CSF leaks. Design A systematic review of studies published since 2000 reporting techniques to prevent CSF leaks during adult TL VS surgery was conducted. A narrative synthesis of primary repair protocols was produced, and a taxonomy was established. Additionally, the advantages, disadvantages, and associated CSF leak rates of different repair protocols were extracted. Results All 43 studies were case series, and 39 were retrospective. Repair strategies included heterogeneous combinations of autografts, xenografts, and synthetic materials. A taxonomy was produced, classifying repairs into seven distinct stages, including approaches to the dura, middle ear cleft, air cells, TL bony defect, extra-cranial soft tissue, postoperative dressings, and CSF diversion. The median postoperative incidence of CSF leaks was 6% (interquartile range: 0–10%). Conclusions This systematic review reveals substantial inter-institutional heterogeneity in intraoperative strategies to prevent CSF leaks following TL VS surgery. However, comparing these techniques is challenging due to the multiple predictive factors for CSF leaks and their inconsistent reporting. We propose a taxonomy of seven stages to classify operative techniques and materials aimed at preventing CSF leaks. We recommend that future evaluations should adopt a prospective approach encompassing data collection strategies that considers all operative stages described by our taxonomy. * Equal senior authorship. Received: 05 September 2023 Accepted: 25 November 2023 Accepted Manuscript online: 04 December 2023 Article published online: 22 January 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany


  • Open Access

    A Deep Learning Approach to Classify Surgical Skill in Microsurgery Using Force Data from a Novel Sensorised Surgical Glove

    by Jialang Xu, Dimitrios Anastasiou, James Booker, Oliver E. Burton, Hugo Layard Horsfall, Carmen Salvadores Fernandez, Yang Xue, Danail Stoyanov, Manish K. Tiwari, Hani J. Marcus, et al.

    Microsurgery serves as the foundation for numerous operative procedures. Given its highly technical nature, the assessment of surgical skill becomes an essential component of clinical practice and microsurgery education. The interaction forces between surgical tools and tissues play a pivotal role in surgical success, making them a valuable indicator of surgical skill. In this study, we employ six distinct deep learning architectures (LSTM, GRU, Bi-LSTM, CLDNN, TCN, Transformer) specifically designed for the classification of surgical skill levels. We use force data obtained from a novel sensorized surgical glove utilized during a microsurgical task. To enhance the performance of our models, we propose six data augmentation techniques. The proposed frameworks are accompanied by a comprehensive analysis, both quantitative and qualitative, including experiments conducted with two cross-validation schemes and interpretable visualizations of the network’s decision-making process. Our experimental results show that CLDNN and TCN are the top-performing models, achieving impressive accuracy rates of 96.16% and 97.45%, respectively. This not only underscores the effectiveness of our proposed architectures, but also serves as compelling evidence that the force data obtained through the sensorized surgical glove contains valuable information regarding surgical skill.