MEMaaike Van Eeckhoutte

Maaike Van Eeckhoutte

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Maaike Van Eeckhoutte has a total of 188 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Acoustic Context Shapes Cortical Encoding of Spectral Discrimination in Normal and Impaired Hearing

    by Jaime A. Undurraga, Ioana Stefancu, Mats Rekswinkel, Lisbeth Birkelund Simonsen, Maaike Van Eeckhoutte

    The auditory change complex (ACC) provides a cortical measure of acoustic discrimination, yet the mechanisms shaping responses to spectrotemporally complex sounds remain poorly understood. We investigated how acoustic context and temporal-envelope variability influence cortical encoding of spectral contrast in normal-hearing (NH) and hearing-impaired (HI) listeners. Electroencephalography (EEG) was used to record ACCs and auditory steady-state responses (ASSRs) evoked by spectrotemporally modulated stimuli. We compared conventional spectro-temporal modulations (STMs) with a novel discrete spectro-temporal modulation (DSTM) paradigm, examined temporal roving, and evaluated cortical responses to spectral contrast in NH and HI listeners. ACCs elicited by DSTM stimuli were larger and more symmetrical across transition directions than those elicited by conventional STMs. Temporal roving markedly reduced responses to intensity changes while largely preserving responses to spectral changes, indicating a partial dissociation between intensity-driven and spectrally driven cortical discrimination. ACC responses decreased systematically with spectral contrast and were weaker and delayed in HI listeners. By contrast, ASSRs remained highly detectable and showed no systematic dependence on spectral contrast, supporting a distinction between contrast-sensitive cortical discrimination and ongoing envelope encoding. Temporal roving further enhanced separation between NH and HI listeners. ACC response strength was significantly associated with behavioural STM discrimination thresholds and explained variance beyond age and audiometric thresholds. These findings demonstrate that cortical representations of spectral discrimination are shaped by acoustic context and temporal-envelope statistics. Temporal roving attenuates intensity-driven responses while preserving spectrally driven discrimination, providing insight into cortical encoding of spectrotemporal contrast and its relationship to perceptual performance.

  • Open Access

    Phoneme Perception in Children With Bilateral Cochlear Implants or Hearing Aids in Quiet, Noise, and Reverberation

    by Maaike Van Eeckhoutte, Regitze Ardenkjær-Husted, Chunlong Zhao, Torsten Dau

    Objectives: The assessment of aided phoneme perception is essential in validating whether hearing aids and cochlear implants adequately meet the amplification and rehabilitation needs of children. Phonemes are commonly used in such assessments to minimize the influence of semantic context and vocabulary knowledge. Traditionally, they have been presented by clinicians using their own voices. This study directly compared the performance of phoneme detection, discrimination, and identification among children with normal hearing, children using hearing aids, children with cochlear implants, and adults with normal hearing. Laboratory procedures and recorded sound files were used throughout. In addition, phoneme discrimination performance was assessed in challenging acoustic environments—specifically those with noise and/or reverberation—mirroring the types of settings children frequently encounter. Design: A total of 60 children and 42 adults participated in the study. The children had an average age of 10 ± 2 yrs, and the adults an average age of 27 ± 5 yrs. The children were divided into 3 groups of 20: those with normal hearing, those using bilateral hearing aids, and those with bilateral cochlear implants. Children with hearing devices were recruited through the Copenhagen Hearing and Balance Center (Rigshospitalet, Denmark) and were tested using their own devices, all fitted according to present best practices. Aided phoneme detection and identification were assessed using the Ling 6(HL) CD sound files, while phoneme discrimination was evaluated using a subset of the DANOK speech corpus. Testing was conducted in a spatial hearing laboratory to examine the impact of noise and reverberation on performance. Results: The results of this study indicate that, aside from minor differences in low-frequency speech phonemes, there were no significant differences between children with hearing aids and those with cochlear implants in phoneme detection, identification, or discrimination across a range of acoustic conditions. All children demonstrated Ling sound detection thresholds in quiet within normal limits, with average thresholds across all Ling sounds below 20 dB HL for all groups (rising to a maximum average of 22 dB HL when analyzed per Ling sound and participant group). Phoneme discrimination was significantly affected by reverberation and noise in all children—more so than in adults—with the most pronounced effects observed in children using hearing aids or cochlear implants. Conclusions: The procedures for aided phoneme detection, discrimination, and identification presented in this study are valuable tools for objectively assessing outcomes and validating benefit in children using hearing aids and cochlear implants. This is particularly important for children with cochlear implants, as electroacoustic verification through real-ear measures is not possible for these devices. The results suggest that phoneme perception in children with hearing aids and those with cochlear implants—despite the fundamentally different nature of these technologies (acoustic versus electric stimulation)—does not differ significantly. The reduced performance in noisy and reverberant conditions among children, especially those with hearing devices, underscores the importance of optimizing signal to noise ratios and acoustic environments in children’s everyday settings to support speech perception, auditory development, and overall wellbeing.

  • Open Access

    Publisher Correction: fNIRS reproducibility varies with data quality, analysis pipelines, and researcher experience

    by Meryem A. Yücel, Robert Luke, Rickson C. Mesquita, Alexander von Lühmann, David M. A. Mehler, Michael Lührs, Jessica Gemignani, Androu Abdalmalak, Franziska Albrecht, Iara de Almeida Ivo, et al.


  • Top Cited Papers
    Open Access

    fNIRS reproducibility varies with data quality, analysis pipelines, and researcher experience

    by Meryem A. Yücel, Robert Luke, Rickson C. Mesquita, Alexander von Lühmann, David M. A. Mehler, Michael Lührs, Jessica Gemignani, Androu Abdalmalak, Franziska Albrecht, Iara de Almeida Ivo, et al.

    As data analysis pipelines grow more complex in brain imaging research, understanding how methodological choices affect results is essential for ensuring reproducibility and transparency. This is especially relevant for functional Near-Infrared Spectroscopy (fNIRS), a rapidly growing technique for assessing brain function in naturalistic settings and across the lifespan, yet one that still lacks standardized analysis approaches. In the fNIRS Reproducibility Study Hub (FRESH) initiative, we asked 38 research teams worldwide to independently analyze the same two fNIRS datasets. Despite using different pipelines, nearly 80% of teams agreed on group-level results, particularly when hypotheses were strongly supported by literature. Teams with higher self-reported analysis confidence, which correlated with years of fNIRS experience, showed greater agreement. At the individual level, agreement was lower but improved with better data quality. The main sources of variability were related to how poor-quality data were handled, how responses were modeled, and how statistical analyses were conducted. These findings suggest that while flexible analytical tools are valuable, clearer methodological and reporting standards could greatly enhance reproducibility. By identifying key drivers of variability, this study highlights current challenges and offers direction for improving transparency and reliability in fNIRS research.


  • Open Access

    The fNIRS Reproducibility Study Hub (FRESH): Exploring Variability and Enhancing Transparency in fNIRS Neuroimaging Research

    by Meryem Ayşe Yücel, Robert Luke, Rickson Coelho Mesquita, Alexander von Lühmann, David Marc Anton Mehler, Michael Lührs, Jessica Gemignani, Androu Abdalmalak, Franziska Albrecht, Iara Almeida, et al.

    In neuroimaging research, efforts to enhance replication and reproducibility have increased the focus on improving transparency, particularly in the complex data analysis processes. We conducted a multi-lab collaborative study involving 38 international teams that analyzed two functional Near-Infrared Spectroscopy (fNIRS) datasets. These teams tested seven group-level and forty individual-level hypotheses, and they submitted detailed reports on their analysis pipelines and testing outcomes. The results showed significant variability in hypothesis testing outcomes due to differences in analytical approaches. There was greater consensus in group-level analyses compared to individual-level analyses. Factors such as the pruning method, hemodynamic response function model and estimation, and statistical analysis space partly account for the variability in hypothesis testing outcomes. Additionally, we have found higher similarity in hypothesis testing outcomes across the researchers who reported higher confidence in their analysis skills. This study underscores the importance of complying with best practices in fNIRS analysis methodologies and the need for standardized analysis protocols to improve reliability and credibility.


  • Open Access

    The fNIRS Reproducibility Study Hub (FRESH): Exploring Variability and Enhancing Transparency in fNIRS Neuroimaging Research

    by Meryem Ayşe Yücel, Robert Luke, Rickson Coelho Mesquita, Alexander von Lühmann, David Marc Anton Mehler, Michael Lührs, Jessica Gemignani, Androu Abdalmalak, Franziska Albrecht, Iara Almeida, et al.

    In neuroimaging research, efforts to enhance replication and reproducibility have increased the focus on improving transparency, particularly in the complex data analysis processes. We conducted a multi-lab collaborative study involving 38 international teams that analyzed two functional Near-Infrared Spectroscopy (fNIRS) datasets. These teams tested seven group-level and forty individual-level hypotheses, and they submitted detailed reports on their analysis pipelines and testing outcomes. The results showed significant variability in hypothesis testing outcomes due to differences in analytical approaches. There was greater consensus in group-level analyses compared to individual-level analyses. Factors such as the pruning method, hemodynamic response function model and estimation, and statistical analysis space partly account for the variability in hypothesis testing outcomes. Additionally, we have found higher similarity in hypothesis testing outcomes across the researchers who reported higher confidence in their analysis skills. This study underscores the importance of complying with best practices in fNIRS analysis methodologies and the need for standardized analysis protocols to improve reliability and credibility.


  • Open Access

    In-situ Audiometry Compared to Conventional Audiometry for Hearing Aid Fitting

    by Maaike Van Eeckhoutte, Bettina Skjold Jasper, Erik Finn Kjærbøl, David Harbo Jordell, Torsten Dau

    The use of in-situ audiometry for hearing aid fitting is appealing due to its reduced resource and equipment requirements compared to standard approaches employing conventional audiometry alongside real-ear measures. However, its validity has been a subject of debate, as previous studies noted differences between hearing thresholds measured using conventional and in-situ audiometry. The differences were particularly notable for open-fit hearing aids, attributed to low-frequency leakage caused by the vent. Here, in-situ audiometry was investigated for six receiver-in-canal hearing aids from different manufacturers through three experiments. In Experiment I, the hearing aid gain was measured to investigate whether corrections were implemented to the prescribed target gain. In Experiment II, the in-situ stimuli were recorded to investigate if corrections were directly incorporated to the delivered in-situ stimulus. Finally, in Experiment III, hearing thresholds using in-situ and conventional audiometry were measured with real patients wearing open-fit hearing aids. Results indicated that (1) the hearing aid gain remained unaffected when measured with in-situ or conventional audiometry for all open-fit measurements, (2) the in-situ stimuli were adjusted for up to 30 dB at frequencies below 1000 Hz for all open-fit hearing aids except one, which also recommends the use of closed domes for all in-situ measurements, and (3) the mean interparticipant threshold difference fell within 5 dB for frequencies between 250 and 6000 Hz. The results clearly indicated that modern measured in-situ thresholds align (within 5 dB) with conventional thresholds measured, indicating the potential of in-situ audiometry for remote hearing care.


  • Open Access

    The use of ecological momentary assessment to evaluate real-world aided outcomes with children

    by Danielle Glista, Robin O’hAgan, Maaike Van Eeckhoutte, Yuanhao Lai, Susan Scollie

    Ecological momentary assessment (EMA) methods allow for real-time, real-world survey data collection. Studies with adults have reported EMA as a feasible and valid tool in the measurement of real-w...


  • Open Access

    Perceptual Benefits of Extended Bandwidth Hearing Aids With Children: A Within-Subject Design Using Clinically Available Hearing Aids

    by Maaike Van Eeckhoutte, Susan Scollie, Robin O'HAgan, Danielle Glista

    Purpose: The aim of the study was to investigate the achieved audibility with clinically available, modern, high-end, behind-the-ear hearing aids fitted using the Desired Sensation Level v5.0 child prescription for a clinical sample of children with hearing impairment and the effect of the extended bandwidth provided by the hearing aids on several outcome measures.Method: The achieved audibility was measured using the maximum audible output frequency method. Twenty-eight children (7–17 years old) with mild to severe hearing losses completed this study. Two hearing aid conditions were fitted for each participant: an extended bandwidth condition, which was fitted to targets as closely as possible, and a restricted bandwidth condition, for which aided output was restricted above 4.5 kHz. Consonant discrimination in noise, subjective preference, aided loudness growth, and preferred listening levels were evaluated in both conditions.Results: The extended bandwidth hearing aid fittings provided speech audibility above 4.5 kHz for all children, with an average maximum audible output frequency of 7376 Hz (SD= 1669 Hz). When compared to a restricted bandwidth, the extended bandwidth condition led to an improvement of 5.4% for consonant discrimination in noise scores, mostly attributable to /s/, /z/, and /t/ phoneme perception. Aided loudness results and preferred listening levels were not significantly different across bandwidth conditions; however, 65% of the children indicated a subjective preference for the extended bandwidth.Conclusion: The study suggests that providing the full bandwidth available, with modern, behind-the-ear hearing aids, leads to improved audibility, when compared to restricted bandwidth hearing aids, and that it leads to beneficial outcomes for children who use hearing aids, fitted to the Desired Sensation Level v5.0 child prescription, without causing significant increases in their loudness perception.


  • Speech recognition, loudness, and preference with extended bandwidth hearing aids for adult hearing aid users

    by Maaike Van Eeckhoutte, Paula Folkeard, Danielle Glista, Susan Scollie

    Objective: In contrast to the past, some current hearing aids can provide gain for frequencies above 4–5 kHz. This study assessed the effect of wider bandwidth on outcome measures using hearing aids fitted with the DSL v5.0 prescription. Design: There were two conditions: an extended bandwidth condition, for which the maximum available bandwidth was provided, and a restricted bandwidth condition, in which gain was reduced for frequencies above 4.5 kHz. Outcome measures were assessed in both conditions. Study sample: Twenty-four participants with mild-to-moderately-severe sensorineural high-frequency sloping hearing loss. Results: Providing extended bandwidth resulted in maximum audible output frequency values of 7.5 kHz on average for an input level of 65 dB SPL. An improvement in consonant discrimination scores (4.1%), attributable to better perception of /s/, /z/, and /t/ phonemes, was found in the extended bandwidth condition, but no significant change in loudness perception or preferred listening levels was found. Most listeners (79%) had either no preference (33%) or some preference for the extended bandwidth condition (46%). Conclusions: The results suggest that providing the maximum bandwidth available with modern hearing aids fitted with DSL v5.0, using targets from 0.25 to 8 kHz, can be beneficial for the tested population.