SSSabar Setiawidayat

Sabar Setiawidayat

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sabar Setiawidayat has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Prototipe Detektor Emisi Kendaraan Bermotor Berbahan Bakar Pertalite dan Pertamax

    by Moch Djunaidi, Sabar Setiawidayat

    Setiap kendaraan bermotor akan menghasilkan gas buang atau emisi seperti Karbondioksida (CO2) dan Karbonmonooksida (CO). Emisi dikeluarkan melalui knalpot sehingga menghasilkan polusi di udara bebas yang dapat mencemari udara disekitarnya yang dapat mempengaruhi kesehatan bagi manusia dan hewan. Kurang terkontrolnya emisi kendaraan yang beroperasi, disebabkan keterbatasan alat monitoring emisi yang hanya dimiliki oleh dinas perhubungan (Dishub) dan Polisi daerah (Polda). Penelitian ini bertujuan untuk merancang prototipe detektor emisi kendaraan bermotor berbahan bakar Pertalite dan Pertamax. Sensor MQ2 untuk konsentrasi kadar gas CO dan sensor kadar konsentrasi MQ7 untuk CO2 di pasang pada knalpot kendaraan dalam keadaan mesin hidup dan diam. Pengambilan data dilakukan pada beberapa kondisi putaran mesin. Berdasarkan hasil pengukuran terhadap 10 sepeda motor, baik pertalite maupun pertamax, kadar CO pada putaran diatas 1000 rpm menyebabkan emisi diatas Nilai Ambang Batas (NAB) sedangkan kadar CO2 masih dalam batas NAB yang aman. Hasil pengukuran terhadap 3 kendaraan roda empat, kadar CO dan CO2, baik pertalite maupun pertamax masih dalam batas NAB yang aman. Terdapat korelasi yang signifikan antara putaran mesin dan kadar emisi, makin tinggi putaran makin tinggi kadar emisi. Hasil uji komparasi dengan alat rferensi menunjukkan bahwa alat desain layak digunakan sebagai alat pengukuran emisi CO dan CO2.

  • Open Access

    The influence of chemical activators on adsorptive properties and solar still performance of activated carbon from Caesalpinia sappan wood

    by Nova Risdiyanto Ismail, Silviana Silviana, Sabar Setiawidayat, Purbo Suwandono

    The availability of drinking water is a global concern today. A source of potable water is seawater processed using a distillation method utilising a solar still. Currently, seawater includes significant concentrations of heavy metals, including arsenic and lead, necessitating the absorption process. This study investigated the absorption of heavy metals from seawater with activated carbon derived from Caesalpinia sappan wood. The application of activators in the production of activated carbon influences both pore dimensions and the efficacy of the adsorption process. This investigation utilized 1 gram of ZnCl2, CaCl2, and Na2CO3 as activators. Activated carbon was introduced into the solar still to a depth of 1 cm. The properties of activated carbon were evaluated using Brunauer-Emmett-Teller (BET) and Scanning Electron Microscope (SEM) techniques. The salt test outcomes of the heavy metal absorption procedure were analyzed using XRF. The findings indicated that the activated carbon activated with ZnCl2 exhibits superior pore properties and demonstrates the highest capacity for heavy metal absorption relative to other activators. The use of ZnCl2 as an activator for activated carbon resulted in the maximum production (3.5 L/m2/day) and efficiency (58%) in solar stills by optimizing porosity, thermal conductivity, and interaction with marine salts. Furthermore, ZnCl2-activated carbon demonstrated an increased surface area and improved adsorption ability, significantly diminishing arsenic and lead levels. The parameters for the practical application of the results indicate that this technology is suitable for coastal and arid areas where saltwater desalination is crucial. This method can be applied in small-scale, off-grid water filtration systems, particularly in isolated populations with restricted access to potable water

  • Open Access

    Perancangan Alat Monitoring Emisi Gas Buang Kendaraan berbahan bakar Solar

    by Felix Felix, Sabar Setiawidayat

    Setiap kendaraan bermotor akan menghasilkan emisi. Emisi yang dimaksud diantaranya adalah Karbondioksida (CO2) dan Karbonmonooksida (CO). Seperti diketahui bahwa dump truck umumnya bermesin diesel dengan bahan bakar solar. Emisi gas buang merupakan hasil pembakaran bahan bakar dalam mesin diesel, yang dikeluarkan melalui knalpot ke udara bebas sehingga menghasilkan polusi. Dampak dari polusi ini maka akan mempengaruhi kesehatan bagi manusia yang menghirupnya, termasuk hewan dan tumbuhan. Kurang terkontrolnya emisi gas buang kendaraan yang beroperasi, disebabkan keterbatasan alat monitoring emisi yang hanya dimiliki oleh instansi tertentu (Dishub dan Polda). Penelitian ini bertujuan untuk merancang alat monitoring emisi kendaraan berbahan bakar solar. Sensor mq2 untuk konsentrasi gas CO dan sensor mq7 untuk konsentrasi CO2 digunakan sebagai detektor emisi. Sensor di pasang di depan knalpot kendaraan dalam keadaan mesin hidup dan posisi diam. Pengambilan data dilakukan pada beberapa kondisi rpm putaran mesin. Berdasarkan hasil pengukuran terhadap 4 kendaraan dump truck, kandungan kadar CO2 semua kendaraan dalam batas aman untuk semua putaran mesin, namun terdapat 1 kendaraan yang memiliki kadar CO diatas Nilai ambang Batas (NAB) pada putaran diatas 1200 rpm. Pengukuran emisi untuk kendaraan pribadi menunjukkan bahwa kadar CO2 untuk semua putaran dalam batas aman sedangkan kadar CO diatas NAB jika putaran diatas 2400 rpm . Hasil uji komparasi nilai CO2 antara alat desain dan CO2 ref menunjukkan tidak ada perbedaan yang signifikan pada a 0.05 untuk 4 kendaraan Kata kunci : . sensor, emisi, monitoring, solar

  • Open Access

    Optimization of Harmony Improvement in Led Lights Using The MQPSO Method

    by Bintang Pratama Krisna Putra, Sabar Setiawidayat, Fachrudin Hunaini

    Currently, there are many types of lighting used in the lighting field, one of which is LED lighting. Harmonics is a phenomenon in the electrical system that causes quality disturbances because the current waveform or voltage of the power source is distorted and can cause disturbances in the electrical system. In this research, mathlab was used with the MQPSO method to optimize LED lamp harmonics and reduce the THD value. This method uses a series of LED lighting components to optimize harmonic values. The components that make up the LED light circuit in question are resistors, capacitors and inductors. The optimization results show the best R, L, and C values ​​in the 53rd swarm (particle), and convergence values ​​are achieved in the 17th iteration with a fitness value of 0.5 and an R1 value of 550 Ω, and R2 530 Ω, R3 220 Ω, C1 1.0409 μF, C2 1.0117 μF, C3 1.0221 μF, L1 4.9984 H. The resulting THD and C-RMS values ​​are 1.4901% and 61.674%.


  • Open Access

    The Duration of the Cycle to Get the P Amplitude on A Discrete Electrocardiogram

    by Sabar Setiawidayat

    The P amplitude value for each cycle has not been carried out even though it is related to indications of atrial hypertrophy. The basic interpretation of the maximum P amplitude under normal conditions is 2.5 small squares on electrocardiogram (ECG) paper which is equivalent to 2.5 mV. Apart from these interpretations, an amplitude value is required that corresponds to the amount of depolarization of the atrial muscle cells. The difficulty faced by researchers is the lack of discrete ecg data available for experiments, so it only depends on amplitude data as a function of Physionet output time. An ECG is produced using discrete data but there is no electrocardiograph that displays discrete data yet. This study aims to obtain the P amplitude value based on discrete electrocardiogram data. The cycle duration value obtained from R to R is used to obtain the initial position of the cycle (sc) with the formula RN+1-1.5dR for each cycle. The P amplitude value can be obtained by filtering the maximum amplitude value between the sc and RN positions. The results of research on 10 physionet samples and 10 RSSA samples showed that all samples had an amplitude R, cycle duration and P amplitude value in each cycle.

  • Open Access

    Discrete electrocardiogram T amplitude detection based on cycle duration

    by Sabar Setiawidayat

    In each cycle of the electrocardiogram wave there are P, Q, R, S and T amplitudes. Many studies have been conducted to obtain amplitude and QRS waves because they are related to ventricular depolarization, but to obtain T amplitude values related to ventricular repolarization are still rarely done, not even for the clinical standard (12 leads). This study aims to obtain the amplitude T value in each cycle and each electrocardiogram lead. Obtaining the amplitude T position on the reference lead will also find the amplitude T value on the other lead. Each cycle duration obtained from the duration RN to RN+1 is used to obtain the position of the endpoint of each cycle. The maximum value between the amplitude S position and the end point of the cycle is the amplitude T value. The results of research on 10 Physionet sinus rhythm samples and 10 Saiful Anwar Hospital Malang samples show that the duration of the cycle was successful in obtaining the amplitude T value for each lead. All samples can display a value. The amplitude in each cycle, where the values obtained in each cycle are still in normal conditions. The amplitude T value obtained is certainly accurate because there is only one positive value between the amplitude S position and the end of the cycle position. The position of the amplitude integer T found in a cycle in one lead will be the same as the position of the amplitude integer T in the cycle for the other lead. This occurs because of the simultaneous transmission of impulses that affect the atrial and ventricular muscle cells. The position of the amplitude T for each cycle can be found by filtering the maximum amplitude value between the amplitude position S and the final position of the cycle. Practically, this method can be programmed to be added to a digital electrocardiograph


  • Open Access

    Karakteristik Lampu Hemat Energi Ditinjau dari Pengaruh Suplai Tegangan Listrik

    by Sabar Setiawidayat, Wahyu Sriyanto

    The circulation of Energy Saving Lamps or Self-Based Lamps in Indonesia, which promises the shape of lamps, variations in lamp power, lamp life, comparison of offered lamp brightness, low power absorption with brighter light, has caused many people to switch from using tube lamps and incandescent lamps to other types of lamps. this lamp. Indonesian Government regulation that requires LHE lamp manufacturers to include the Indonesian National Standard label as proof that the lamp is within the specified Efficacy limit. General Regulation of Electrical Installation and PT. PLN urges its consumers that electricity users can maintain the load power factor of not less than 0.8. This study aims to determine the amount of current consumption and electrical power required by LHE lamps labeled with SNI from the Panasonic, Shinyoku and ACR brands which were obtained randomly in the market. 10 lamps 18 watts, 220 volts as a sample, given a variation of the supply voltage between 110 volts to 240 volts with 10 volt steps. The results showed that the average real power at a voltage of 220 volts was in accordance with the labels on all brands. All three lamp brands have a power factor below 0.5. Characteristics of voltage to real power for Panasonic LHE obtained y = -0.0226x2 + 8.889x - 673.88, LHE Shinyoku y = -0.0002x2 + 0.3184x + 109.22, and LHE ACR y = -0.0003x2 + 0.2852x + 120.91

  • Open Access

    Prototipe Sistem Monitoring dan Controlling HSD Tank PLTGU Grati Berbasis IoT

    by Mokhammad Saddam Yusuf, Gigih Priyandoko, Sabar Setiawidayat

    PLTGU Grati memiliki tangki bahan bakar minyak (HSD tank) dengan kapasitas 20.000 kl. Volume minyak di dalam tangki harus selalu dipantau agar tidak terjadi kelebihan kapasitas saat pengisian maupun kekurangan bahan bakar saat proses produksi listrik. Pengukuran volume tangki masih dilakukan secara manual menggunakan Sounding Tape Richter. Pengukuran level tangki secara manual tentunya tidak efektif dan efisien, serta memungkinkan terjadinya kesalahan pembacaan skala pada meteran yang dapat mengakibatkan perhitungan persediaan bahan bakar minyak tidak akurat. Penelitian ini dilakukan untuk merancang sebuah perangkat keras untuk monitoring persediaan bahan bakar minyak menggunakan sensor ultrasonic HC-SR04, monitoring temperatur bahan bakar minyak menggunakan sensor suhu DS18B20, sistem pendeteksi kebakaran di sekitar tangki bahan bakar minyak menggunakan sensor api SEN-0004 dan sensor asap MQ-7, serta kendali manual untuk mengoperasikan pompa transfer saat proses pengisian tangki bahan bakar dari jarak jauh. Hasil pengukuran sensor ditampilkan pada Aplikasi Blynk dan LCD 20x4 Characters. Berdasarkan analisis hasil pengujian menggunakan software SPSS dengan metode Independent Sample T-test diketahui bahwa sensor ultrasonic HC-SR04 memiliki nilai signifikansi pengukuran level sebesar 0,893 dan pengukuran volume sebesar 0,953, sedangkan sensor suhu DS18B20 memiliki nilai signifikansi pengukuran suhu sebesar 0,990. Hasil tersebut menunjukkan bahwa tidak terdapat perbedaan hasil yang signifikan antara hasil pembacaan sensor dengan alat ukur standar.Grati Combined Cycle Power Plant has a fuel oil tanks (HSD tanks) with a capacity of 20.000 KL. The volume of oil in the tank must always be monitored so that there is no excess capacity when filling or shortage of fuel during the electricity production process. Measurement of the volume of the tank is still done manually using Sounding Tape Richter. Manually measuring the tank level is certainly not effective and efficient, and allows for an error in reading the scale on the meter which can result in inaccurate fuel oil inventory calculations. This research was conducted to design a hardware device for monitoring fuel oil inventories using an ultrasonic sensor HC-SR04, monitoring fuel oil temperature using a DS18B20 temperature sensor, a fire detection system around the fuel oil tank using a fire sensor SEN-0004 and smoke sensor MQ-7, as well as manual control to remotely operate the transfer pump during the fuel tank filling process. Sensor measurement results are displayed on the Blynk Application and the 20x4 Characters LCD. Based on the analysis of test results using SPSS software with the Independent Sample T-test method, it is known that the ultrasonic sensor HC-SR04 has a level measurement significance value of 0.893 and a volume measurement of 0.953, while the DS18B20 temperature sensor has a temperature measurement significance value of 0.990. These results indicate that there is no significant difference between the results of sensor readings and standard measuring instruments.