Lorico D. S. Lapitan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lorico D. S. Lapitan has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Bernard John V. Tongol
2 shared publicationsCristina E. Tiangco
Research Center for the Natural and Applied Sciences and Department of Chemical Engineering Faculty of Engineering University of Santo Tomas España Boulevard Manila Philippines
2 shared publicationsShueh-Lin Yau
2 shared publicationsAmmu Rosin Jose
Department of Chemistry Sacred Heart College (Autonomous) Pandit Karuppan Rd, Thevara Ernakulam Kerala India
1 shared publicationBren Mark B. Felisilda
Department of Electrode Processes Institute of Physical Chemistry Polish Academy of Sciences Kasprzaka 44/52 01-224 Warsaw Poland Department of Chemistry College of Arts & Sciences Xavier University-Ateneo de Cagayan Corrales Street Cagayan de Oro Philippines
1 shared publication- Dejian Zhou
University of Leeds
1 shared publication
Latest Publications
- 7 August 2024
- Published by Wiley in Chemistry – An Asian Journal
- Vol. 19 (18) , e202400090
Advances in Bioreceptor Layer Engineering in Nanomaterial‐based Sensing of Pseudomonas Aeruginosa and its Metabolites
Pseudomonas aeruginosa is a pathogen that infects wounds and burns and causes severe infections in immunocompromised humans. The high virulence, the rise of antibiotic‐resistant strains, and the easy transmissibility of P. aeruginosa necessitate its fast detection and control. The gold standard for detecting P. aeruginosa, the plate culture method, though reliable, takes several days to complete. Therefore, developing accurate, rapid, and easy‐to‐use diagnostic tools for P. aeruginosa is highly desirable. Nanomaterial‐based biosensors are at the forefront of detecting P. aeruginosa and its secondary metabolites. This review summarises the biorecognition elements, biomarkers, immobilisation strategies, and current state‐of‐the‐art biosensors for P. aeruginosa. The review highlights the underlying principles of bioreceptor layer engineering and the design of optical, electrochemical, mass‐based, and thermal biosensors based on nanomaterials. The advantages and disadvantages of these biosensors and their future point‐of‐care applications are also discussed. This review outlines significant advancements in biosensors and sensors for detecting P. aeruginosa and its metabolites. Research efforts have identified biorecognition elements specific and selective towards P. aeruginosa. The stability, ease of preparation, cost‐effectiveness, and integration of these biorecognition elements onto transducers are pivotal for their application in biosensors and sensors. At the same time, when developing sensors for clinically significant analytes such as P. aeruginosa, virulence factors need to be addressed, such as the sensor‘s sensitivity, reliability, and response time in samples obtained from patients. The point‐of‐care applicability of the developed sensor may be an added advantage since it enables onsite determination. In this context, optical methods developed for P. aeruginosa offer promising potential.
- 7 August 2024
- Published by Wiley in Chemistry – An Asian Journal
- Vol. 19 (18) , e202400090
Advances in Bioreceptor Layer Engineering in Nanomaterial‐based Sensing of Pseudomonas Aeruginosa and its Metabolites
Pseudomonas aeruginosa is a pathogen that infects wounds and burns and causes severe infections in immunocompromised humans. The high virulence, the rise of antibiotic‐resistant strains, and the easy transmissibility of P. aeruginosa necessitate its fast detection and control. The gold standard for detecting P. aeruginosa, the plate culture method, though reliable, takes several days to complete. Therefore, developing accurate, rapid, and easy‐to‐use diagnostic tools for P. aeruginosa is highly desirable. Nanomaterial‐based biosensors are at the forefront of detecting P. aeruginosa and its secondary metabolites. This review summarises the biorecognition elements, biomarkers, immobilisation strategies, and current state‐of‐the‐art biosensors for P. aeruginosa. The review highlights the underlying principles of bioreceptor layer engineering and the design of optical, electrochemical, mass‐based, and thermal biosensors based on nanomaterials. The advantages and disadvantages of these biosensors and their future point‐of‐care applications are also discussed. This review outlines significant advancements in biosensors and sensors for detecting P. aeruginosa and its metabolites. Research efforts have identified biorecognition elements specific and selective towards P. aeruginosa. The stability, ease of preparation, cost‐effectiveness, and integration of these biorecognition elements onto transducers are pivotal for their application in biosensors and sensors. At the same time, when developing sensors for clinically significant analytes such as P. aeruginosa, virulence factors need to be addressed, such as the sensor‘s sensitivity, reliability, and response time in samples obtained from patients. The point‐of‐care applicability of the developed sensor may be an added advantage since it enables onsite determination. In this context, optical methods developed for P. aeruginosa offer promising potential.
- Top Cited Papers
- 1 April 2021
- Published by Elsevier in Education for Chemical Engineers
- Vol. 35, 116-131
An effective blended online teaching and learning strategy during the COVID-19 pandemic
- 1 April 2021
- Published by Elsevier in Education for Chemical Engineers
- Vol. 35, 116-131
Top Cited PapersAn effective blended online teaching and learning strategy during the COVID-19 pandemic
- Open Access
- 12 March 2015
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 140 (12) , 3872-3887
Nano-enabled bioanalytical approaches to ultrasensitive detection of low abundance single nucleotide polymorphisms
Single nucleotide polymorphisms (SNPs) constitute the most common types of genetic variations in the human genome. A number of SNPs have been linked to the development of life threatening diseases including cancer, cardiovascular diseases and neurodegenerative diseases. The ability for ultrasensitive and accurate detection of low abundant disease-related SNPs in bodily fluids (e.g. blood, serum, etc.) holds a significant value in the development of non-invasive future biodiagnostic tools. Over the past two decades, nanomaterials have been utilized in a myriad of biosensing applications due to their ability of detecting extremely low quantities of biologically important biomarkers with high sensitivity and accuracy. Of particular interest is the application of such technologies in the detection of SNPs. The use of various nanomaterials, coupled with different powerful signal amplification strategies, has paved the way for a new generation of ultrasensitive SNP biodiagnostic assays. Over the past few years, several ultrasensitive SNP biosensors capable of detecting specific targets down to the ultra-low regimes (ca. aM and below) and therefore holding great promises for early clinical diagnosis of diseases have been developed. This mini review will highlight some of the most recent, significant advances in nanomaterial-based ultrasensitive SNP sensing technologies capable of detecting specific targets on the attomolar (10−18 M) regime or below. In particular, the design of novel, powerful signal amplification strategies that hold the key to the ultrasensitivity is highlighted.
- 12 March 2015
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 140 (12) , 3872-3887
Open AccessNano-enabled bioanalytical approaches to ultrasensitive detection of low abundance single nucleotide polymorphisms
Single nucleotide polymorphisms (SNPs) constitute the most common types of genetic variations in the human genome. A number of SNPs have been linked to the development of life threatening diseases including cancer, cardiovascular diseases and neurodegenerative diseases. The ability for ultrasensitive and accurate detection of low abundant disease-related SNPs in bodily fluids (e.g. blood, serum, etc.) holds a significant value in the development of non-invasive future biodiagnostic tools. Over the past two decades, nanomaterials have been utilized in a myriad of biosensing applications due to their ability of detecting extremely low quantities of biologically important biomarkers with high sensitivity and accuracy. Of particular interest is the application of such technologies in the detection of SNPs. The use of various nanomaterials, coupled with different powerful signal amplification strategies, has paved the way for a new generation of ultrasensitive SNP biodiagnostic assays. Over the past few years, several ultrasensitive SNP biosensors capable of detecting specific targets down to the ultra-low regimes (ca. aM and below) and therefore holding great promises for early clinical diagnosis of diseases have been developed. This mini review will highlight some of the most recent, significant advances in nanomaterial-based ultrasensitive SNP sensing technologies capable of detecting specific targets on the attomolar (10−18 M) regime or below. In particular, the design of novel, powerful signal amplification strategies that hold the key to the ultrasensitivity is highlighted.
- 1 January 2014
- Published by Elsevier in Advanced Powder Technology
- Vol. 25 (1) , 365-371
Synthesis of cobalt boride nanoparticles using RF thermal plasma
- 1 January 2014
- Published by Elsevier in Advanced Powder Technology
- Vol. 25 (1) , 365-371
Synthesis of cobalt boride nanoparticles using RF thermal plasma
- 1 February 2012
- Published by Elsevier in Electrochimica Acta
- Vol. 62, 433-440
In situ scanning tunneling microscopy imaging of electropolymerized poly(3,4-ethylenedioxythiophene) on an iodine-modified Au(111) single crystal electrode
- 1 February 2012
- Published by Elsevier in Electrochimica Acta
- Vol. 62, 433-440
In situ scanning tunneling microscopy imaging of electropolymerized poly(3,4-ethylenedioxythiophene) on an iodine-modified Au(111) single crystal electrode
- 14 May 2010
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 26 (13) , 10771-10777
Molecular Assembly and Electropolymerization of 3,4-Ethylenedioxythiophene on Au(111) Single Crystal Electrode as Probed by In Situ Electrochemical STM in 0.10 M HClO4
We have used electrochemical scanning tunneling microscopy (EC-STM) to obtain molecular insights on the adlayer structures and electrochemical polymerization of 3,4-ethylenedioxythiophene (EDOT) on a bare Au(111) single crystal electrode in 0.1 M HClO4 solution. Cyclic voltammetric (CV) studies showed an increase in anodic current at 0.90 V with the oxidation of EDOT monomer occurring at E = 1.10 V (vs reversible hydrogen electrode). In situ STM revealed, for the first time, that EDOT molecules can spontaneously form organized adlayers on a bare Au(111) surface with 18 μM concentration of EDOT in aqueous solution. Molecularly resolved STM images of the EDOT adlayer showed two domains consisting of disordered and ordered structures with the formation of vacancy islands or “etch pits”. Several EDOT structures were observed at +0.60 V, namely, (4 × 7), (5 × √37), and (√7 × 3) with calculated coverages of 0.107, 0.114, and 0.111 ML, respectively. Electropolymerization was also carried out using in situ STM in 0.10 M HClO4 under potential control.
- 14 May 2010
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 26 (13) , 10771-10777
Molecular Assembly and Electropolymerization of 3,4-Ethylenedioxythiophene on Au(111) Single Crystal Electrode as Probed by In Situ Electrochemical STM in 0.10 M HClO4
We have used electrochemical scanning tunneling microscopy (EC-STM) to obtain molecular insights on the adlayer structures and electrochemical polymerization of 3,4-ethylenedioxythiophene (EDOT) on a bare Au(111) single crystal electrode in 0.1 M HClO4 solution. Cyclic voltammetric (CV) studies showed an increase in anodic current at 0.90 V with the oxidation of EDOT monomer occurring at E = 1.10 V (vs reversible hydrogen electrode). In situ STM revealed, for the first time, that EDOT molecules can spontaneously form organized adlayers on a bare Au(111) surface with 18 μM concentration of EDOT in aqueous solution. Molecularly resolved STM images of the EDOT adlayer showed two domains consisting of disordered and ordered structures with the formation of vacancy islands or “etch pits”. Several EDOT structures were observed at +0.60 V, namely, (4 × 7), (5 × √37), and (√7 × 3) with calculated coverages of 0.107, 0.114, and 0.111 ML, respectively. Electropolymerization was also carried out using in situ STM in 0.10 M HClO4 under potential control.