SOShigeyuki Okahara

Shigeyuki Okahara

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shigeyuki Okahara has a total of 38 co-authors. Here are the top co-authors by number of shared publications:

  • Satoshi Miyamoto

    Department of Clinical Engineering, Hiroshima University Hospital, Hiroshima, Japan

    9 shared publications
  • Toshio Tsuji

    Graduate School of Advanced Science and Engineering, Hiroshima University, Higashihiroshima, Japan

    9 shared publications
  • Hidenobu Takahashi

    Faculty of Health Sciences, Department of Medical Science and Technology, Hiroshima International University, Hiroshima, Japan

    7 shared publications
  • Zu Soh

    Graduate School of Advanced Science and Engineering, Hiroshima University, Hiroshima, Japan

    7 shared publications
  • Taijiro Sueda

    Department of Cardiovascular Surgery, Hiroshima University Hospital, Hiroshima, Japan

    5 shared publications
  • Shinya Takahashi

    Department of Cardiovascular Surgery, Hiroshima University Hospital, Hiroshima 734-8551, Japan

    4 shared publications

Latest Publications

  • Correlation Analysis Between Echinocytosis Stages and Blood Viscosity During Oxygenator Perfusion: An In Vitro Study

    by Shigeyuki Okahara, Satoshi Miyamoto, Zu Soh, Masaru Yoshino, Hidenobu Takahashi, Hideshi Itoh, Toshio Tsuji

    The study aimed to investigate the effect of red blood cell (RBC) morphology on oxygenator perfusion, focusing on stages of echinocytosis and their correlation with blood viscosity. A test circuit with an oxygenator and human RBC mixtures was used to induce changes in RBC shape by increasing sodium salicylate concentrations (0, 10, 20, 30, 60, and 120 mmol/L), while hematocrit, blood temperature, and anticoagulation were maintained. Blood viscosity was measured using a continuous blood viscosity monitoring system based on pressure-flow characteristics. Under a scanning electron microscope, the percentages of discocytes, echinocytes I–III, spheroechinocytes, and spherocytes were determined from approximately 400 cells per RBC sample. Early echinocytes, mainly discocytes and echinocytes I and II in the range of 0–30 mmol/L were predominant, resulting in a gradual increase in blood viscosity from 1.78 ± 0.12 to 1.94 ± 0.12 mPa s. At 60 mmol/L spherocytes emerged, and at 120 mmol/L, spheroidal RBCs constituted 50% of the population, and blood viscosity sharply rose to 2.50 ± 0.15 mPa s, indicating a 40% overall increase. In conclusion, the presence of spherocytes significantly increases blood viscosity, which may affect oxygenator perfusion.

  • Open Access

    The Number of Microbubbles Generated During Cardiopulmonary Bypass Can Be Estimated Using Machine Learning From Suction Flow Rate, Venous Reservoir Level, Perfusion Flow Rate, Hematocrit Level, and Blood Temperature

    by Satoshi Miyamoto, Zu Soh, Shigeyuki Okahara, Akira Furui, Taiichi Takasaki, Keijiro Katayama, Shinya Takahashi, Toshio Tsuji

    Goal: Microbubbles (MBs) are known to occur within the circuits of cardiopulmonary bypass (CPB) systems, and higher-order dysfunction after cardiac surgery may be caused by MBs as well as atheroma dispersal associated with cannula insertion. As complete MB elimination is not possible, monitoring MB count rates is critical. We propose an online detection system with a neural network-based model to estimate MB count rate using five parameters: suction flow rate, venous reservoir level, perfusion flow rate, hematocrit level, and blood temperature. Methods: Perfusion experiments were performed using an actual CPB circuit, and MB count rates were measured using the five varying parameters. Results: Bland–Altman analysis indicated a high estimation accuracy ( R2 > 0.95, p < 0.001) with no significant systematic error. In clinical practice, although the inclusion of clinical procedures slightly decreased the estimation accuracy, a high coefficient of determination for 30 clinical cases ( R2 = 0.8576) was achieved between measured and estimated MB count rates. Conclusions: Our results highlight the potential of this system to improve patient outcomes and reduce MB-associated complication risk.


  • Open Access

    Simultaneous Control of Venous Reservoir Level and Arterial Flow Rate in Cardiopulmonary Bypass With a Centrifugal Pump

    by Hidenobu Takahashi, Takuya Kinoshita, Zu Soh, Shigeyuki Okahara, Satoshi Miyamoto, Shinji Ninomiya, Toshio Tsuji

    Cardiopulmonary bypass (CPB) is an indispensable technique in cardiac surgery, providing the ability to temporarily replace cardiopulmonary function and create a bloodless surgical field. Traditionally, the operation of CPB systems has depended on the expertise and experience of skilled perfusionists. In particular, simultaneously controlling the arterial and venous occluders is difficult because the blood flow rate and reservoir level both change, and failure may put the patient’s life at risk. This study proposes an automatic control system with a two-degree-of-freedom model matching controller nested in an I-PD feedback controller to simultaneously regulate the blood flow rate and reservoir level. CPB operations were performed using glycerin and bovine blood as perfusate to simulate flow-up and flow-down phases. The results confirmed that the arterial blood flow rate followed the manually adjusted target venous blood flow rate, with an error of less than 5.32%, and the reservoir level was maintained, with an error of less than 3.44% from the target reservoir level. Then, we assessed the robustness of the control system against disturbances caused by venting/suction of blood. The resulting flow rate error was 5.95%, and the reservoir level error 2.02%. The accuracy of the proposed system is clinically satisfactory and within the allowable error range of 10% or less, meeting the standards set for perfusionists. Moreover, because of the system’s simple configuration, consisting of a camera and notebook PC, the system can easily be integrated with general CPB equipment. This practical design enables seamless adoption in clinical settings. With these advancements, the proposed system represents a significant step towards the automation of CPB.


  • Open Access

    Online Prediction of Normal Blood Viscosity During Cardiopulmonary Bypass Using Hematocrit- and Temperature-Dependent Model

    by Shigeyuki Okahara, Satoshi Miyamoto, Zu Soh, Hideshi Itoh, Shinya Takahashi, Toshio Tsuji

    This paper proposes a mathematical model for online prediction of the hematocrit-and temperature-based normal blood viscosity during cardiopulmonary bypass (CPB). Clinical trials were performed using a previously developed continuous blood viscosity monitoring system, and continuous pressure-and flow-based instantaneous viscosity (ηe) data were collected from 40 patients subjected to mild to moderate hypothermic CPB. The hematocrit and blood temperature data corresponding to ηe were also acquired. It was found that the blood viscosity.temperature curves for the different hematocrit levels can be well fitted using linear models, with the parameters of the linear model (slopes and intersects) also exhibiting linear relationships with the hematocrit. Based on these relationships, we were able to predict the hematocrit-and temperature-based normal viscosity (η0). To test the prediction accuracy, η0 was compared with ge using the leave-one-out cross-validation procedure. Furthermore, η0 and the offline-measured viscosity (η), determined using a conventional viscometer, were compared for 20 patients subjected to mildly hypothermic CPB. η0 and ηe—two online blood viscosity monitoring methods based on different principles—showed good agreement (R2 = 0.74 and p < 0.0001). Moreover, η0 and gη also showed good agreement (R2 = 0.69 and p < 0.0001). The proposed model is suitable for online prediction of the hematocrit-and temperature-based normal blood viscosity during CPB. The proposed model can function as the core of a future application for investigating the effects of blood viscosity during clinical perfusion management and facilitate detailed online blood viscosity studies.


  • Abdominal organ protection strategy for aortic arch aneurysm surgery

    by Satoshi Miyamoto, Shinya Takahashi, Shigeyuki Okahara, Hidenobu Takahashi, Keijiro Katayama, Masazumi Watanabe, Kazuki Maeda, Seimei Go, Shohei Morita, Tatsuya Kurosaki, et al.

    Introduction: Body temperature maintained during open distal anastomosis in patients who undergo aortic surgery has been showing an upward trend; however, a higher temperature may increase visceral organ and spinal cord injury. Distal perfusion may reduce abdominal organ injury, especially acute kidney injury (AKI). Methods: From 2009 to 2016, 56 patients who underwent ascending aortic and/or aortic arch surgery were enrolled. Open distal anastomosis was performed using one of three protection strategies: 1) systemic temperature of 25°C followed by selective cerebral perfusion (SCP) with lower body circulatory arrest (Group CA25, n=27); 2) systemic temperature of 28°C followed by SCP with lower body circulatory arrest (Group CA28, n=4); and 3) systemic temperature of 28°C followed by SCP with distal aortic perfusion (Group DP, n=25). Results: During the postoperative course, levels of blood urea nitrogen, creatinine, liver enzymes, lactate dehydrogenase and lactate in Groups CA28 and CA25 were significantly higher than those in Group DP. AKI defined by the AKI Network occurred in 28 cases (50%) and 3 cases required permanent hemodialysis. AKI was significantly higher in Groups CA25 and CA28 than in Group DP (p=0.026). Mid-term follow-up showed that patients who developed postoperative AKI were more likely to suffer from cardiovascular events. Conclusions: Distal perfusion during open distal anastomosis reduced kidney and liver injury after thoracic aortic surgery despite an increased body temperature of up to 28°C. This strategy may be useful to prevent AKI, liver dysfunction, the need for hemodialysis and multiple organ failure and could improve mid-term results.


  • Abdominal organ protection: distal perfusion during replacement of the ascending aorta and aortic arch

    by Satoshi Miyamoto, Shinya Takahashi, Shigeyuki Okahara, Hidenobu Takahashi, Keijiro Katayama, Masazumi Watanabe, Takahiro Taguchi, Tatsuya Kurosaki, Bagus Herlambang, Taijiro Sueda

    Article: Abdominal organ protection: distal perfusion during replacement of the ascending aorta and aortic arch - The Journal of Cardiovascular Surgery 2018 June;59(3):485-6 - Minerva Medica - Journals

  • A Novel Blood Viscosity Estimation Method Based on Pressure‐Flow Characteristics of an Oxygenator During Cardiopulmonary Bypass

    by Shigeyuki Okahara, Zu Soh, Satoshi Miyamoto, Hidenobu Takahashi, Hideshi Itoh, Shinya Takahashi, Taijiro Sueda, Toshio Tsuji

    During cardiopulmonary bypass (CPB), blood viscosity conspicuously increases and decreases due to changes in hematocrit and blood temperature. Nevertheless, blood viscosity is typically not evaluated, because there is no technology that can provide simple, continuous, noncontact monitoring. We modeled the pressure‐flow characteristics of an oxygenator in a previous study, and in that study we quantified the influence of viscosity on oxygenator function. The pressure‐flow monitoring information in the oxygenator is derived from our model and enables the estimation of viscosity. The viscosity estimation method was proposed and investigated in an in vitro experiment. Three samples of whole bovine blood with different hematocrit levels (21.8, 31.0, and 39.8%) were prepared and perfused into the oxygenator. As the temperature changed from 37°C to 27°C, the mean inlet pressure (Pin) and outlet pressure (Pout) of the oxygenator and the flow (Q) and viscosity of the blood were measured. The estimated viscosity was calculated from the pressure gradient (ΔP = Pin − Pout) and Q and was compared to the measured blood viscosity. A strong correlation was found between the two methods for all samples. Bland‐Altman analysis revealed a mean bias of −0.0263 mPa.s, a standard deviation of 0.071 mPa.s, limits of agreement of −0.114–0.166 mPa.s, and a percent error of 5%. Therefore, this method is considered compatible with the torsional oscillation viscometer that has plus or minus 5% measurement accuracy. Our study offers the possibility of continuously estimating blood viscosity during CPB.


  • Blood viscosity monitoring during cardiopulmonary bypass based on pressure-flow characteristics of a Newtonian fluid

    by Shigeyuki Okahara, Zu Soh, Shinya Takahashi, Taijiro Sueda, Toshio Tsuji

    We proposed a blood viscosity estimation method based on pressure-flow characteristics of oxygenators used during cardiopulmonary bypass (CPB) in a previous study that showed the estimated viscosity to correlate well with the measured viscosity. However, the determination of the parameters included in the method required the use of blood, thereby leading to high cost of calibration. Therefore, in this study we propose a new method to monitor blood viscosity, which approximates the pressure-flow characteristics of blood considered as a non-Newtonian fluid with characteristics of a Newtonian fluid by using the parameters derived from glycerin solution to enable ease of acquisition. Because parameters used in the estimation method are based on fluid types, bovine blood parameters were used to calculate estimated viscosity (ηe), and glycerin parameters were used to estimate deemed viscosity (ηdeem). Three samples of whole bovine blood with different hematocrit levels (21.8%, 31.0%, and 39.8%) were prepared and perfused into the oxygenator. As the temperature changed from 37 °C to 27 °C, the oxygenator mean inlet pressure and outlet pressure were recorded for flows of 2 L/min and 4 L/min, and the viscosity was estimated. The value of deemed viscosity calculated with the glycerin parameters was lower than estimated viscosity calculated with bovine blood parameters by 20-33% at 21.8% hematocrit, 12-27% at 31.0% hematocrit, and 10-15% at 39.8% hematocrit. Furthermore, deemed viscosity was lower than estimated viscosity by 10-30% at 2 L/min and 30-40% at 4 L/min. Nevertheless, estimated and deemed viscosities varied with a similar slope. Therefore, this shows that deemed viscosity achieved using glycerin parameters may be capable of successfully monitoring relative viscosity changes of blood in a perfusing oxygenator.


  • Continuous Blood Viscosity Monitoring System for Cardiopulmonary Bypass Applications

    by Shigeyuki Okahara, Zu Soh, Satoshi Miyamoto, Hidenobu Takahashi, Shinya Takahashi, Taijiro Sueda, Toshio Tsuji

    This paper proposes an algorithm that estimates blood viscosity during cardiopulmonary bypass (CPB) and validates its application in clinical cases. The proposed algorithm involves adjustable parameters based on the oxygenator and fluid types and estimates blood viscosity based on pressure-flow characteristics of the fluid perfusing through the oxygenator. This novel nonlinear model requires four parameters that were derived by in vitro experiments. The results estimated by the proposed method were then compared with a conventional linear model to demonstrate the former's optimal curve fitting. The viscosity (η e ) estimated using the proposed algorithm and the viscosity (η) measured using a viscometer were compared for 20 patients who underwent mildly hypothermic CPB. The developed system was applied to ten patients, and η e was recorded for comparisons with hematocrit and blood temperature. The residual sum of squares between the two curve fittings confirmed the significant difference, with p <; 0.001. η e and η showed a very strong correlation with R 2 = 0.9537 and p <; 0.001. Regarding the mean coefficient of determination for all cases, the hematocrit and temperature showed weak correlations at 0.33 ± 0.14 and 0.22 ± 0.21, respectively. For CPB measurements of all cases, η e was more than 98% distributed in the range from 1 to 3 mPa·s. This new system for estimating viscosity may be useful for detecting various viscosity-related effects that may occur during CPB.


  • A blood viscosity estimation method based on pressure-flow characteristics of an oxygenator during cardiopulmonary bypass and its clinical application

    by Shigeyuki Okahara, Toshio Tsuji, Zu Soh, Shinya Takahashi, Taijiro Sueda

    In this paper, we developed a model that uses pressure-flow monitoring information in the oxygenator to estimate viscosity of human blood. The comparison between estimated viscosity (η e ) and measured viscosity (η) was assessed in 16 patients who underwent cardiac surgery using mild hypothermia cardiopulmonary bypass (CPB). After initiation of CPB, η e was recorded at three periods: post-establishment of total CPB, post-aortic cross-clamp, and post-declamp. During the same period, blood samples were collected from the circuit and η was measured with a torsional oscillation viscometer. The η e was plotted as a function of η and the systematic errors and compatibility between two methods were assessed using Bland-Altman analysis. The parameters η e and η were very strongly correlated at all points (R 2 =0.9616, p<;0.001). The Bland-Altman analysis revealed a mean bias of -0.001 mPas, a standard deviation of 0.03 mPas, limits of agreement of -0.06 mPas to 0.06 mPas, and a percent error of 3.3%. There was no fixed bias or proportion bias for the viscosity. As this method estimates blood viscosity with good precision during CPB continuously, it may be helpful for clinical perfusion management.