ZLZitong Lin

Zitong Lin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zitong Lin has a total of 139 co-authors. Here are the top co-authors by number of shared publications:

  • Antian Gao

    Department of Dentomaxillofacial Radiology, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School Nanjing University Nanjing China

    17 shared publications
  • Xiao Pan

    Department of Dentomaxillofacial Radiology, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology, Nanjing University, Nanjing, P.R. China

    11 shared publications
  • Ziyang Hu

    Department of Dentomaxillofacial Radiology, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology, Nanjing University, Nanjing, China

    9 shared publications
  • Dantong Cao

    Department of Dentomaxillofacial Radiology, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology, Nanjing University, Nanjing, China

    8 shared publications
  • Yanni Hu

    Department of Dentomaxillofacial Radiology, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology, Nanjing University, Nanjing, China

    6 shared publications
  • Ziyang Hu

    Department of Stomatology, Shenzhen Longhua District Central Hospital, Shenzhen, China

    6 shared publications

Latest Publications

  • Open Access

    Development and validation of artificial intelligence-based full dentition labiolingual reconstruction using CBCT images

    by Xiao Pan, Wenxi Zhang, Xuhui Luo, Wentao Zhang, Hongyan Qu, Runzhi Deng, Zitong Lin

    Objective: To development and validate an artificial intelligence (AI) -based system for automatic full dentition labiolingual reconstruction (DenRec-LL) using Cone beam computed tomography (CBCT) images. Methods: DenRec-LL was developed by generating 2D panoramic images, segmenting and identifying teeth with a transformer framework, mapping tooth centroids into 3D coordinates for 2D–3D alignment, performing 3D tooth segmentation using deep learning, and reconstructing the full dentition labiolingually based on estimated tooth axes, centers, and missing-tooth prediction. 75 external CBCT datasets (25 normal dentition, 25 mixed dentition and 25 crowded dentition) were collected and used for testing. The performance of DenRec-LL system was evaluated on a 4-point scale, the geometric deviation metrics were analyzed and the clinical acceptability rate (CAR) was calculated, and the reconstruction time was recorded. Results: 75 CBCT datasets with 1500 teeth demonstrates high precision and stability across normal, mixed, and crowded dentition. A clear majority of labiolingual reconstruction cases (93.1%) achieved the highest score, and CAR was approximately 94% across groups, with no significant differences. The automated process required 63 ± 4 s per case, representing an approximately 4.85-fold reduction compared to the manual process. Conclusions: The DenRec-LL system could be used for full dentition reconstruction with high accuracy, robustness and efficiency. Clinical significance: DenRec-LL bridges the gap between raw CBCT data and clinical decision‑making in routine orthodontic practice by automatically generating full‑dentition labiolingual images, which facilitate the assessment of root‑bone relationships and torque control.

  • Low-dose cone-beam CT in implant dentistry: a clinical validation of diagnostic sufficiency

    by Ruiyang Ni, Xuhui Luo, Nuo Han, Ziyang Hu, Zitong Lin

    Objective: To validate the diagnostic sufficiency of a low-dose (LD) cone-beam CT (CBCT) protocol for dental implant assessment by comparing it to a standard-dose (SD) protocol in a clinical setting. The study evaluated linear measurement accuracy, subjective clarity of anatomical landmarks, and the impact on bone microarchitecture assessment. Methods: This retrospective study analyzed preoperative (SD) and postoperative (LD) CBCT scans from 37 patients (37 SD and 37 LD scans for both maxillary and mandibular sites). The LD protocol achieved a 76.7% dose reduction by decreasing tube current and exposure time. The diagnostic utility was assessed: (1) subjective clarity scoring of the mandibular canal and maxillary sinus floor; (2) objective linear measurements of key anatomical dimensions; and (3) quantitative analysis of bone microstructural parameters (trabecular number [Tb.N], trabecular separation [Tb.Sp], trabecular thickness [Tb.Th], bone volume fraction [BV/TV]). Reliability assessment was also performed for clarity scoring and quantitative measurements. Statistical comparisons were performed using Chi-square and paired-samples t-tests. Results: No statistically significant differences were found between the LD and SD protocols in the subjective clarity of anatomical structures (P > .05) or in the accuracy of linear measurements (P > .05). However, all 4 bone microstructural parameters showed statistically significant differences between the 2 protocols in both the maxilla and mandible (P < .05 for all). Intra- and inter-examiner assessments demonstrated substantial to good consistency across all qualitative (weighted Kappa >0.611) and quantitative (intra-class correlation coefficient [ICC] >0.702) parameters. Conclusion: This study provides clinical evidence that for the specific CBCT unit tested, the optimized LD CBCT protocol reduces patient radiation exposure by over 76.7% for dental implant assessment without compromising the diagnostic accuracy required for linear measurements and visualization of key anatomical landmarks. Therefore, for the tested model, the LD protocol is sufficient for preoperative CBCT scanning in implant dentistry. This offers a clinically validated method for enhancing patient safety in this specific context, effectively applying the As Low As Diagnostically Acceptable, Indication-oriented, and Patient-specific (ALADAIP) principle.

  • Vertical Root Fracture in Endodontically Treated Teeth: Risk Factors and Future Directions

    by Xuhui Luo, Wenxi Zhang, Nuo Han, Bin Xue, Zitong Lin

    This article provides a narrative review of risk factors of vertical root fractures (VRFs) in endodontically treated teeth, focusing on treatment‐related factors and occlusal factors. Studies on treatment‐related risk factors include experimental studies on the formation of dentinal microcracks caused by different root canal preparation instruments, as well as experimental studies on the variations in dentine volume and fracture resistance resulting from different access cavity and root canal preparation instruments. Studies on occlusal risk factors encompass high‐risk occlusal forces, stress distribution alterations on root due to crown morphology changes and crown restoration. Currently, occlusal analysis techniques and force measurement methods remain limited, with far fewer studies available compared to those on treatment‐related risk factors. Finally, this narrative review offers a prospect on occlusal risk factors exploration based on flexible sensor technology.

  • Open Access

    SBMN: Similarity-Based Memory Network for the Diagnosis of Vertical Root Fracture in Dental Imaging

    by Jie Wang, Xin Yan Jin, Yi Fan Zhang, Jie Yuan, Zi Tong Lin, Ying Chen

    Background/Objectives: Medical image analysis of vertical root fractures (VRFs) is challenged by limited annotated data, class imbalance, and subtle inter-class differences. To address these issues, we propose an SBMN: a Similarity-Based Memory Network that integrates Category Memory with the Basic SBMN Module and a similarity-based classifier. Methods: An SBMN stores representative features for each class and leverages similarity-based gating to enhance feature discrimination. Experiments were conducted on a CBCT dataset of fractured and non-fractured teeth to evaluate performance. Results: The SBMN achieved up to 97.1% and 99.7% classification accuracy on automatically and manually segmented images, respectively. Memory manipulation experiments confirm the critical role of Category Memory in controlling classification outcomes. Conclusions: These results indicate that SBMNs offer an effective and interpretable approach for small-sample medical image classification and diagnosis.

  • [Root fracture in endodontically versus nonendodontically treated posterior teeth: the cone beam computed tomography characteristics in Chinese population].

    by Chengyi Fu, Xiao Pan, Shu Liu, Zitong Lin

    This study aimed to investigate the clinical and cone beam computed tomography (CBCT) characteristics of root fractures in endodontically versus nonendodontically treated posterior teeth. A total of 340 posterior teeth from 305 patients were retrospectively collected. The fractured teeth were divided into endodontically treated (ET) teeth and nonendodontically treated (NET) teeth. The clinical information (age and gender of patients) was recorded. The type of fractured tooth, fractured root, orientation of fracture lines (vertical, horizontal, oblique, and irregular), direction of vertical fracture lines, location of horizontal root fractures, and bone resorption around fractured roots were evaluated and recorded based on CBCT images. 1) The distribution of teeth was significantly different between NET and ET teeth (P=0.028). Root fractures predominantly occurred in mandibular and maxillary molars. However, the proportion of premolars was significantly higher in ET teeth (27.2%) than in NET teeth (14.2%). 2) We observed a significant difference in root distribution between NET roots and ET roots (P=0.037). The mesial roots of mandibular molars were the most common fractured roots in NET and ET roots (36.4% in NET roots and 32.2% in ET roots); however, the second most common roots were the palatal roots of maxillary molars in NET roots (23.0%) and the maxillary premolar roots in ET roots (20.3%). 3) A statistically significant difference in the orientation of root fractures was observed between the two groups (PP=0.58), with both types predominantly presenting as buccal-palatal fractures (86.0% and 84.1%). 5) No significant difference was observed in the location of horizontal fractures between NET and ET root fractures (P=0.132), and the most common site was the cervical third of roots. 6) Bone loss around fractured lines significantly differed between NET and ET root fractures (P<0.001). Around 59% exhibited obvious bone loss around fractured roots in NET root fractures, whereas 91.8% of fractured roots presented bone loss in ET root fractures. The NET root fractured teeth and ET root fractured teeth presented quite different clinical and CBCT characteristics. The complex and diverse traits of NET root fractured teeth indicate the influence of multifaceted occlusal factors in their occurrence. By contrast, ET root fractured teeth demonstrate high uniformity, indicating that their occurrence may be related to the structural changes caused by endodontic treatment.

  • Open Access

    Development and verification of a convolutional neural network-based model for automatic mandibular canal localization on multicenter CBCT images

    by Xiao Pan, Chengtao Wang, Xuhui Luo, Qi Dong, Haiyang Sun, Wentao Zhang, Hongyan Qu, Runzhi Deng, Zitong Lin

    Development and verification of a convolutional neural network (CNN)-based deep learning (DL) model for mandibular canal (MC) localization on multicenter cone beam computed tomography (CBCT) images. In this study, a total 1056 CBCT scans in multiple centers were collected. Of these, 836 CBCT scans of one manufacturer were used for development of CNN model (training set: validation set: internal testing set = 640:360:36) and an external testing dataset of 220 CBCT scans from other four manufacturers were tested. The convolution module was built using a stack of Conv + InstanceNorm + LeakyReLU. Average symmetric surface distance (ASSD) and symmetric mean curve distance (SMCD) were used for quantitative evaluation of this model for both internal testing data and partial external testing data. Visual scoring (1–5 points) were performed to evaluate the accuracy and generalizability of MC localization for all external testing data. The differences of ASSD, SMCD and visual scores among the four manufacturers were compared for external testing dataset. The time of manual and automatic MC localization were recorded. For the internal testing dataset, the average ASSD and SMCD was 0.486 mm and 0.298 mm respectively. For the external testing dataset, 86.8% CBCT scans’ visual scores ≥ 4 points; the average ASSD and SMCD of 40 CBCT scans with visual scores ≥ 4 points were 0.438 mm and 0.185 mm respectively; there were significant differences among the four manufacturers for ASSD, SMCD and visual scores (p < 0.05). And the time for bilateral automatic MC localization was 8.52s (± 0.97s). In this study, a CNN model was developed for automatic MC localization, and external testing of large sample on multicenter CBCT images showed its excellent clinical application potential.


  • Open Access

    Expert consensus on imaging diagnosis and analysis of early correction of childhood malocclusion

    by Zitong Lin, Chenchen Zhou, Ziyang Hu, Zuyan Zhang, Yong Cheng, Bing Fang, Hong He, Hu Wang, Gang Li, Jun Guo, et al.

    Early correction of childhood malocclusion is timely managing morphological, structural, and functional abnormalities at different dentomaxillofacial developmental stages. The selection of appropriate imaging examination and comprehensive radiological diagnosis and analysis play an important role in early correction of childhood malocclusion. This expert consensus is a collaborative effort by multidisciplinary experts in dentistry across the nation based on the current clinical evidence, aiming to provide general guidance on appropriate imaging examination selection, comprehensive and accurate imaging assessment for early orthodontic treatment patients.


  • Characteristics of vertical root fractures at early stages: Evidence that dentinal microcracks are an experimental phenomenon

    by Xiao Pan, Wenjing Liu, Chengtao Wang, Antian Gao, Zitong Lin

    Aim: The aim of this study was to investigate the characteristics of vertical root fractures (VRFs) at early stages and compare them with previously reported dentinal microcracks.Methodology: Endodontically treated teeth with vertical root fractures at early stages were collected. The characteristics of these VRFs were evaluated by in vitro observation and micro‐CT scanning: (1) the number of fractures (buccal, lingual, mesial and distal were counted separately); (2) vertical extension on the roots (classified into four categories according to cemento‐enamel junction and root apex involved or not); (3) the direction of fractures (bucco‐lingual or mesial‐distal); (4) horizontal extension of fractures (involved the root canal wall or the root surface or both); (5) the width of fractures (measured at the widest site on the axial micro‐CT image); and (6) the location of the widest fractured site on the root (coronal third portion, middle third portion and apical third portion).Results: A total of 28 vertical root fractures at early stages were collected in this study, involving 30 roots with a total of 51 fractures. All fractures involved the middle portion of root; all fractures were bucco‐palatal/lingual and extended from the root canal wall to the root surface. The maximum width of these fractures were <150 μm, and widest fractures may be at the coronal, middle or apical third portion of the tooth root.Conclusions: All vertical root fractures involved the middle portion of root, initiated from the root canal wall and directed buccal‐lingually. The fractures were irregular and tortuous, with fracture widths exhibiting considerable variability. These characteristics help us to have a better understanding of the initiation and development of VRFs, and also supply evidence dentinal microcracks are an experimental phenomenon.


  • Open Access

    Accuracy of implant height and width measurement with triaxial rotation method based on cone-beam CT

    by Ziyang Hu, Zhengding Yuan, Dantong Cao, Rong Tang, Shu Liu, Shanhui Wen, Antian Gao, Zitong Lin


  • Open Access

    The exploration of a compound cone-beam CT contrast agent for diagnosis of human extracted cracked tooth

    by Ziyang Hu, Yanni Hu, Shi Xu, Jia Zhuang, Dantong Cao, Antian Gao, Xin Xie, Zitong Lin