Sharbacha S. Edward
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sharbacha S. Edward has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
Imran Zoberi
Department of Radiation Oncology, Washington University in St. Louis, St. Louis, MO
4 shared publicationsMaria A. Thomas
Department of Radiation Oncology, Washington University in St. Louis, St. Louis, MO
4 shared publicationsJacqueline E. Zoberi
Department of Radiation Oncology, Washington University in St. Louis, St. Louis, MO
3 shared publicationsJose Garcia-Ramirez
Department of Radiation Oncology, Washington University School of Medicine, St. Louis, MO
3 shared publicationsKaren E. Mooney
Department of Radiation Oncology, Thomas Jefferson University, Philadelphia, PA
3 shared publicationsMichael B. Altman
Department of Radiation Oncology, Washington University School of Medicine, St. Louis, MO
3 shared publications
Latest Publications
- Open Access
- 18 February 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (5) , e70017
IROC phantoms accurately detect MLC delivery errors
Purpose: We evaluated the impact of random and whole‐bank multileaf collimator (MLC) delivery errors on dosimetric delivery accuracy in the Imaging and Radiation Oncology Core (IROC) phantom audits, as well as differences in delivery accuracy between the IROC phantom prescription and typical clinical fraction sizes.Methods and Materials: Plans were created for the IROC IMRT head and neck (H&N) and SBRT spine phantoms. MLC leaf errors were introduced into the plans: random shifts between −2 and 2 mm, and whole bank shifts of 0.5, 1, and 2 mm. Plans were recalculated and delivered on a Varian Truebeam, and the log files were analyzed using Mobius Fx software. A second study examined the impact of fraction size on MLC position accuracy and corresponding dose delivery accuracy. The standard IROC phantom prescriptions (∼6 Gy) were scaled to the extremes of 2 Gy for H&N and 27 Gy for spine. All plans (original and scaled) were delivered on a Varian Truebeam and 21EX machine.Results: Random MLC positioning errors produced small average dose deviations in the PTV of up to −2.8% for H&N and 0.7% for spine. Whole‐bank MLC shifts resulted in larger average PTV dose deviations up to 8% for H&N and 7.1% for spine. The Varian 21EX irradiations had greater MLC root mean square (RMS) error than Truebeam plans. Plans with smaller prescriptions (and faster leaf motion) had greater MLC RMS errors, but plan accuracy was not affected dosimetrically – all results remained within 1% regardless of fraction size.Conclusions: Both random and whole bank MLC shifts caused dose deviations in the IROC phantoms that were comparable to clinical results previously found in the literature. Deviations measured with ion chambers were well matched with delivery log file analysis. Smaller dose‐per‐fraction prescriptions caused larger MLC RMS errors that were detected with log files, but were clinically insignificant compared to the dosimetric accuracy of the plan.
- 18 February 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (5) , e70017
Open AccessIROC phantoms accurately detect MLC delivery errors
Purpose: We evaluated the impact of random and whole‐bank multileaf collimator (MLC) delivery errors on dosimetric delivery accuracy in the Imaging and Radiation Oncology Core (IROC) phantom audits, as well as differences in delivery accuracy between the IROC phantom prescription and typical clinical fraction sizes.Methods and Materials: Plans were created for the IROC IMRT head and neck (H&N) and SBRT spine phantoms. MLC leaf errors were introduced into the plans: random shifts between −2 and 2 mm, and whole bank shifts of 0.5, 1, and 2 mm. Plans were recalculated and delivered on a Varian Truebeam, and the log files were analyzed using Mobius Fx software. A second study examined the impact of fraction size on MLC position accuracy and corresponding dose delivery accuracy. The standard IROC phantom prescriptions (∼6 Gy) were scaled to the extremes of 2 Gy for H&N and 27 Gy for spine. All plans (original and scaled) were delivered on a Varian Truebeam and 21EX machine.Results: Random MLC positioning errors produced small average dose deviations in the PTV of up to −2.8% for H&N and 0.7% for spine. Whole‐bank MLC shifts resulted in larger average PTV dose deviations up to 8% for H&N and 7.1% for spine. The Varian 21EX irradiations had greater MLC root mean square (RMS) error than Truebeam plans. Plans with smaller prescriptions (and faster leaf motion) had greater MLC RMS errors, but plan accuracy was not affected dosimetrically – all results remained within 1% regardless of fraction size.Conclusions: Both random and whole bank MLC shifts caused dose deviations in the IROC phantoms that were comparable to clinical results previously found in the literature. Deviations measured with ion chambers were well matched with delivery log file analysis. Smaller dose‐per‐fraction prescriptions caused larger MLC RMS errors that were detected with log files, but were clinically insignificant compared to the dosimetric accuracy of the plan.
- 13 May 2020
- Published by Elsevier in Practical Radiation Oncology
- Vol. 10 (5) , 372-381
Differences in the Patterns of Failure Between IROC Lung and Spine Phantom Irradiations
- 13 May 2020
- Published by Elsevier in Practical Radiation Oncology
- Vol. 10 (5) , 372-381
Differences in the Patterns of Failure Between IROC Lung and Spine Phantom Irradiations
- Open Access
- 1 October 2018
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 19 (6) , 306-315
A snapshot of medical physics practice patterns
A large number of surveys have been sent to the medical physics community addressing many clinical topics for which the medical physicist is, or may be, responsible. Each survey provides an insight into clinical practice relevant to the medical physics community. The goal of this study was to create a summary of these surveys giving a snapshot of clinical practice patterns. Surveys used in this study were created using SurveyMonkey and distributed between February 6, 2013 and January 2, 2018 via the MEDPHYS and MEDDOS listserv groups. The format of the surveys included questions that were multiple choice and free response. Surveys were included in this analysis if they met the following criteria: more than 20 responses, relevant to radiation therapy physics practice, not single‐vendor specific, and formatted as multiple‐choice questions (i.e., not exclusively free‐text responses). Although the results of free response questions were not explicitly reported, they were carefully reviewed, and the responses were considered in the discussion of each topic. Two‐hundred and fifty‐two surveys were available, of which 139 passed the inclusion criteria. The mean number of questions per survey was 4. The mean number of respondents per survey was 63. Summaries were made for the following topics: simulation, treatment planning, electron treatments, linac commissioning and quality assurance, setup and treatment verification, IMRT and VMAT treatments, SRS/SBRT, breast treatments, prostate treatments, brachytherapy, TBI, facial lesion treatments, clinical workflow, and after‐hours/emergent treatments. We have provided a coherent overview of medical physics practice according to surveys conducted over the last 5 yr, which will be instructive for medical physicists.
- 1 October 2018
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 19 (6) , 306-315
Open AccessA snapshot of medical physics practice patterns
A large number of surveys have been sent to the medical physics community addressing many clinical topics for which the medical physicist is, or may be, responsible. Each survey provides an insight into clinical practice relevant to the medical physics community. The goal of this study was to create a summary of these surveys giving a snapshot of clinical practice patterns. Surveys used in this study were created using SurveyMonkey and distributed between February 6, 2013 and January 2, 2018 via the MEDPHYS and MEDDOS listserv groups. The format of the surveys included questions that were multiple choice and free response. Surveys were included in this analysis if they met the following criteria: more than 20 responses, relevant to radiation therapy physics practice, not single‐vendor specific, and formatted as multiple‐choice questions (i.e., not exclusively free‐text responses). Although the results of free response questions were not explicitly reported, they were carefully reviewed, and the responses were considered in the discussion of each topic. Two‐hundred and fifty‐two surveys were available, of which 139 passed the inclusion criteria. The mean number of questions per survey was 4. The mean number of respondents per survey was 63. Summaries were made for the following topics: simulation, treatment planning, electron treatments, linac commissioning and quality assurance, setup and treatment verification, IMRT and VMAT treatments, SRS/SBRT, breast treatments, prostate treatments, brachytherapy, TBI, facial lesion treatments, clinical workflow, and after‐hours/emergent treatments. We have provided a coherent overview of medical physics practice according to surveys conducted over the last 5 yr, which will be instructive for medical physicists.
- 1 January 2018
- Published by Elsevier in Brachytherapy
- Vol. 17 (1) , 40-49
Efficiency of using the day-of-implant CT for planning of SAVI APBI
- 1 January 2018
- Published by Elsevier in Brachytherapy
- Vol. 17 (1) , 40-49
Efficiency of using the day-of-implant CT for planning of SAVI APBI
- 1 September 2016
- Published by Elsevier in Brachytherapy
- Vol. 15 (5) , 616-624
Accelerated partial breast irradiation dosimetric criteria for the strut-adjusted volume implant
- 1 September 2016
- Published by Elsevier in Brachytherapy
- Vol. 15 (5) , 616-624
Accelerated partial breast irradiation dosimetric criteria for the strut-adjusted volume implant
- 1 May 2016
- Published by Elsevier in Brachytherapy
- Vol. 15, S28-S29
Standardization and Automation of Quality Assurance for High Dose Rate Brachytherapy Planning Utilizing the API within Brachyvision
- 1 May 2016
- Published by Elsevier in Brachytherapy
- Vol. 15, S28-S29
Standardization and Automation of Quality Assurance for High Dose Rate Brachytherapy Planning Utilizing the API within Brachyvision
- 1 May 2016
- Published by Elsevier in Brachytherapy
- Vol. 15, S61-S62
Robustness of Plan Evaluation Criteria for Accelerated Partial Breast Irradiation with the Strut Adjusted Volume Implant (SAVI)
- 1 May 2016
- Published by Elsevier in Brachytherapy
- Vol. 15, S61-S62
Robustness of Plan Evaluation Criteria for Accelerated Partial Breast Irradiation with the Strut Adjusted Volume Implant (SAVI)