DGDiego Felipe Gaia

Diego Felipe Gaia

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Diego Felipe Gaia has a total of 182 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Ring Fracture of Brazilian Aortic Valve Bioprostheses Using Non-Compliant High-Pressure Transcatheter Balloon, an Ex Vivo Test

    by Andre Lupp Mota, Diego Felipe Gaia, José Honório Palma da Fonseca

    Aortic valve bioprostheses ring fracture in valve-in-valve procedures has shown low complication rates and presents as an option in the treatment of patients at high risk for conventional surgery, avoiding high transvalvular gradients, which are associated with increased mortality. Some prostheses available in the market cannot be fractured. In an ex vivo test, the possibility of ring fracture of aortic valve bioprostheses produced in Brazil when submitted to radial force application using a high-pressure non-compliant balloon was evaluated. One unit of each aortic valve bioprosthesis model, sizes 19 and 21 mm, produced by Brazilian companies (Braile Biomédica, Cardioprótese, and Labcor), was used. In the experiment, a non-compliant high-pressure balloon (Atlas®-Gold), 1 mm larger than the external diameter of the prosthesis, was positioned inside the valve annulus and inflated gradually aiming to fracture the prosthesis. Fracture pressures and photographic and radiological images of the prostheses before and after test were recorded. All prostheses were fractured. In the models with metal ring, the fracture pressures were between 23 and 25 atm. In the other prostheses, the rupture occurred between 10 and 13 atm. No deformations in the structure were observed, which could potentially damage the aortic root. All the Brazilian prostheses evaluated were fractured, although the presence of a metal ring in the prosthesis framework increases the pressure required for fracture. The information obtained helps in the planning of valve-in-valve procedures in patients with aortic valve bioprostheses.


  • Open Access

    First-in-Human Endo-Bentall Procedure for Simultaneous Treatment of the Ascending Aorta and Aortic Valve

    by Diego Felipe Gaia, Oscar Bernal, Edilberto Castilho, Carolina Baeta Neves Duarte Ferreira, Danny Dvir, Matheus Simonato, José Honório Palma


  • Hemodynamic and Imaging Assessment of Transcatheter Aortic Valve Replacement with the Inovare® Proseal using Multislice Computed Tomography

    by Apoana Gomes Fiori, Matheus Simonato, Alfredo Eyer, José Honório Palma Da Fonseca, Diego Felipe Gaia

    Objective: To evaluate the hemodynamic performance (Le., gradients and paravalvular leakage [PVL]) of the new and experimental Braile Inovare (R) Proseal. Additionally, we aimed to assess pre and postoperatively the aortic annulus and the transcatheter prosthesis using multislice computed tomography (MSCT). Methods: Patients were selected by a multidisciplinary heart team and referred for transcatheter aortic valve replacement (TAVR). MSCT was performed before and after surgery. Measurements of the aortic valve and prosthesis were conducted and correlated with the valve gradient and residual PVL. Results: Twenty-one patients were selected for the protocol. Patients had a mean age of 79 years and 38% of them were of female sex. The mean EuroSCORE II value was 12.5%+/- 10.8. Mean gradient was reduced from 45.8 +/- 11.04 mmHg to 5.59 +/- 2.61 mmHg and there were no instances of PVL worse than mild. There were no cases of coronary obstruction or procedural death. Circularity was present in all prostheses evaluated. Circularity indexes for the prostheses were: inflow 0.05 +/- 0.03, middle third 0.04 +/- 0.02, and outflow 0.04 +/- 0.02 (P=0.08). The mean distance between the prosthesis and the left and right coronary ostia were 14.8 mm-+/- 3.3 and 17.3 mm-+/- 3, respectively. Oversizing was appropriate with a mean of 22.14%+/- 6%. Conclusion: Braile Inovare (R) Proseal transcatheter device has demonstrated low gradients with low rates of PVL. Oversizing by annular measurements was adequate. MSCT was adequate to evaluate device sizing and has demonstrated preserved expansibility and circularity in the evaluated cases.


  • Mortality prediction after transcatheter treatment of failed bioprosthetic aortic valves utilizing various international scoring systems: Insights from the Valve‐in‐Valve International Data (VIVID)

    by Mina Aziz, Matheus Simonato, John G. Webb, Mohamed Abdel‐Wahab, Doff McElhinney, Alison Duncan, Didier Tchetche, Marco Barbanti, Anna Sonia Petronio, Francesco Maisano, et al.

    Background: Transcatheter Aortic Valve Implantation (TAVI) is commonly used to deploy new bioprosthetic valves inside degenerated surgically implanted aortic valves in high risk patients. The three scoring systems used to assess risk of postprocedural mortality are: Logistic EuroSCORE (LES), EuroSCORE II (ES II), and Society of Thoracic Surgeons (STS).Objective: The purpose of this study is to analyze the accuracy of LES, ES II, and STS in estimating all‐cause mortality after transcatheter aortic valve‐in‐valve (ViV) implantations, which was not assessed before.Methods: Using the Valve‐in‐Valve International Data (VIVID) registry, a total of 1,550 patients from 110 centers were included. The study compared the observed 30‐day overall mortality vs. the respective predicted mortalities calculated by risk scores. The accuracy of prediction models was assessed based on calibration and discrimination.Results: Observed mortality at 30 days was 5.3%, while average expected mortalities by LES, ES II and STS were 29.49 (± 17.2), 14.59 (± 8.6), and 9.61 (± 8.51), respectively. All three risk scores overestimated 30‐day mortality with ratios of 0.176 (95% CI 0.138–0.214), 0.342 (95% CI 0.264–0.419), and 0.536 (95% CI 0.421–0.651), respectively. 30‐day mortality ROC curves demonstrated that ES II had the largest AUC at 0.722, followed by STS at 0.704, and LES at 0.698.Conclusions: All three scores overestimated mortality at 30 days with ES II showing the highest predictability compared to LES and STS; and therefore, should be recommended for ViV procedures. There is a need for a dedicated scoring system for patients undergoing ViV interventions.


  • Top Cited Papers

    1-Year Outcomes of Transcatheter Mitral Valve Replacement in Patients With Severe Mitral Annular Calcification

    by Mayra Guerrero, Marina Urena, Dominique Himbert, Dee Dee Wang, Mackram Eleid, Susheel Kodali, Isaac George, Tarun Chakravarty, Moses Mathur, David Holzhey, et al.


  • Impact of Pre-Existing Prosthesis-Patient Mismatch on Survival Following Aortic Valve-in-Valve Procedures

    by Philippe Pibarot, Matheus Simonato, Marco Barbanti, Axel Linke, Ran Kornowski, Tanja Rudolph, Mark Spence, Neil Moat, Gabriel Aldea, Marco Mennuni, et al.


  • Open Access

    Mitral implant of the Inovare transcatheter heart valve in failed surgical bioprostheses: a novel alternative for valve-in-valve procedures

    by Diego Felipe Gaia, Ademir Massarico Braz, Matheus Simonato, Danny Dvir, João Roberto Breda, Gustavo Calado Ribeiro, Carolina Baeta Ferreira, José Augusto Marcondes Souza, Enio Buffolo, José Honório Palma

    OBJECTIVES: Reoperative procedure for the treatment of a failed mitral bioprosthesis is associated with considerable risk. In some cases, mortality is high and might contraindicate the benefit of the procedure. The minimally invasive valve-in-valve (ViV) transcatheter mitral valve implant offers an alternative less-invasive approach, reducing morbidity and mortality. The objective of this paper was to evaluate the mitral ViV approach using the Braile Inovare prosthesis. METHODS: The transcatheter balloon-expandable Braile Inovare prosthesis was used in 12 cases. Procedures were performed in a hybrid operating room, under fluoroscopic and echocardiographic control. Through left minithoracotomy, the prostheses were implanted through the cardiac apex. Serial echocardiographic and clinical examinations were performed. Follow-up varied from 1 to 30 months. RESULTS: A total of 12 transapical mitral ViV procedures were performed. Patients had a mean age of 61.6 ± 9.9 years and 92% were women. Mean logistic EuroSCORE was 20.1%. Successful valve implantation was possible in all cases. In one case, a right lateral thoracotomy was performed for the removal of an embolized prosthesis. There was no operative mortality. Thirty-day mortality was 8.3%. Ejection fraction was preserved after the implant (66.7%; 64.8%; P = 0.3). The mitral gradient showed a significant reduction (11 mmHg; 6 mmHg; P < 0.001). Residual mitral regurgitation was not present. There was no left ventricular outflow tract obstruction. CONCLUSIONS: The mitral ViV implant in a failed bioprosthesis is an effective procedure. This possibility might alter prosthesis selection in the future initial surgical prosthesis selection, favouring bioprostheses. Further large trials should explore its safety.


  • In vitro evaluation of implantation depth in valve-in-valve using different transcatheter heart valves

    by Matheus Simonato, Ali N. Azadani, John Webb, Jonathon Leipsic, Ran Kornowski, Alec Vahanian, David Wood, Nicolo Piazza, Susheel Kodali, Jian Ye, et al.

    The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)


  • New Braile Inovare transcatheter aortic prosthesis: clinical results and follow-up

    by Diego Felipe Gaia, João Roberto Breda, Carolina Baeta Neves Duarte Ferreira, José Augusto Marcondes de Souza, Murilo Teixeira Macedo, Marcus Vinícius Gimenes, Aline Couto, Matheus Simonato, Luis Furlan Financi, Enio Buffolo, et al.

    The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)


  • Open Access

    Off-pump transapical closure of a mitral periprosthetic leak: a new approach to a difficult problem

    by Diego Felipe Gaia, João Roberto Breda, Claudio Henrique Fischer, José Honório Palma

    A 60-year old male patient with multiple risk factors and two previous interventions over the mitral valve was admitted to the emergency unit with symptoms of cardiac failure. Initial examination revealed a competent mitral bioprosthesis with severe perivalvular mitral insufficiency. Based on previous experiences with transapical procedures, a transapical transcatheter closure of the perivalvular leak was performed. The apex was punctured with a 7 French introducer sheath, and a hydrophilic guidewire was advanced with the aid of a right Judkins catheter and positioned across the defect in the left atrium. Fluoroscopic and tridimensional transoesophageal echocardiography was used to guide the manoeuvre. Next, a long introducer sheath was advanced through the guidewire and positioned inside the left atrium. Two Amplatzer Vascular Plug II (St Jude Medical) were deployed, resulting in a significant reduction in the perivalvular leak. The procedure was considered to be successful. The patient regained consciousness, and the orotracheal tube was removed in the operating theatre. No neurological deficits were detected, and the patient was transferred to the intensive care unit. The patient recovered well and was transferred to the ward after 1 day. Discharge was accomplished after 4 days.