Riaz Hussain
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Riaz Hussain has a total of 106 co-authors. Here are the top co-authors by number of shared publications:
- Laura L. Walkup
Division of Pulmonary Medicine Cincinnati Children's Hospital Medical Center Cincinnati Ohio USA
9 shared publications - Matthew M. Willmering
Division of Pulmonary Medicine Cincinnati Children's Hospital Medical Center Cincinnati Ohio USA
9 shared publications - Zackary I. Cleveland
Center for Pulmonary Imaging Research Cincinnati Children's Hospital Medical Center Cincinnati Ohio USA
9 shared publications - Abdullah S. Bdaiwi
Center for Pulmonary Imaging Research, Division of Pulmonary Medicine Cincinnati Children's Hospital Medical Center Cincinnati Ohio USA
8 shared publications - Joseph W. Plummer
National Heart, Lung, and Blood Institute, National Institutes of Health
6 shared publications - Elizabeth L. Kramer
Division of Pulmonary Medicine, Cincinnati Children’s Hospital Medical Center, Cincinnati, Ohio
3 shared publications
Latest Publications
- 1 October 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 8 (5)
Hyperpolarized Xenon 129 MRI to Evaluate Regional Gas-Exchange Abnormalities in Cystic Fibrosis Lung Disease
Hyperpolarized xenon 129 MRI revealed gas-exchange abnormalities in participants with cystic fibrosis compared with control participants; these abnormalities were not correlated with spirometry but persisted despite cystic fibrosis transmembrane conductance regulator modulator therapy.
- 1 October 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 8 (5)
Hyperpolarized Xenon 129 MRI to Evaluate Regional Gas-Exchange Abnormalities in Cystic Fibrosis Lung Disease
Hyperpolarized xenon 129 MRI revealed gas-exchange abnormalities in participants with cystic fibrosis compared with control participants; these abnormalities were not correlated with spirometry but persisted despite cystic fibrosis transmembrane conductance regulator modulator therapy.
- 19 January 2026
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (3) , e70227
A Comprehensive Framework for Uncertainty Quantification of Voxel‐Wise Supervised Deep Learning Models in IVIM MRI
Accurate estimation of intravoxel incoherent motion (IVIM) parameters from diffusion‐weighted MRI remains challenging due to the ill‐posed nature of the inverse problem and high sensitivity to noise, particularly in the perfusion compartment. In this work, we propose a probabilistic deep learning framework based on deep ensembles (DEs) of mixture density networks (MDNs), enabling estimation of total predictive uncertainty and decomposition into aleatoric (AU) and epistemic (EU) components. The method was benchmarked against nonprobabilistic neural networks, a Bayesian fitting approach, and a probabilistic network with single Gaussian parametrization. Supervised training was performed on synthetic data, and evaluation was conducted on both simulated and in vivo brain mouse dataset. The reliability of the quantified uncertainties was assessed using calibration curves, output distribution sharpness, and the continuous ranked probability score (CRPS). MDNs produced more calibrated and sharper predictive distributions for the diffusion coefficient () and the perfusion fraction () parameters, although slight overconfidence was observed in the pseudodiffusion coefficient (). The robust coefficient of variation (RCV) indicated smoother in vivo estimates for with MDNs compared with Gaussian model. Despite the training data covering the expected physiological range, elevated EU in vivo suggests a mismatch with real acquisition conditions, highlighting the importance of incorporating EU, which was allowed by DE. Overall, we present a comprehensive framework for IVIM fitting with uncertainty quantification, which enables the identification and interpretation of unreliable estimates. The proposed approach can also be adopted for fitting other physical models through appropriate architectural and simulation adjustments.
- 19 January 2026
- Published by Wiley in NMR in Biomedicine
- Vol. 39 (3) , e70227
A Comprehensive Framework for Uncertainty Quantification of Voxel‐Wise Supervised Deep Learning Models in IVIM MRI
Accurate estimation of intravoxel incoherent motion (IVIM) parameters from diffusion‐weighted MRI remains challenging due to the ill‐posed nature of the inverse problem and high sensitivity to noise, particularly in the perfusion compartment. In this work, we propose a probabilistic deep learning framework based on deep ensembles (DEs) of mixture density networks (MDNs), enabling estimation of total predictive uncertainty and decomposition into aleatoric (AU) and epistemic (EU) components. The method was benchmarked against nonprobabilistic neural networks, a Bayesian fitting approach, and a probabilistic network with single Gaussian parametrization. Supervised training was performed on synthetic data, and evaluation was conducted on both simulated and in vivo brain mouse dataset. The reliability of the quantified uncertainties was assessed using calibration curves, output distribution sharpness, and the continuous ranked probability score (CRPS). MDNs produced more calibrated and sharper predictive distributions for the diffusion coefficient () and the perfusion fraction () parameters, although slight overconfidence was observed in the pseudodiffusion coefficient (). The robust coefficient of variation (RCV) indicated smoother in vivo estimates for with MDNs compared with Gaussian model. Despite the training data covering the expected physiological range, elevated EU in vivo suggests a mismatch with real acquisition conditions, highlighting the importance of incorporating EU, which was allowed by DE. Overall, we present a comprehensive framework for IVIM fitting with uncertainty quantification, which enables the identification and interpretation of unreliable estimates. The proposed approach can also be adopted for fitting other physical models through appropriate architectural and simulation adjustments.
- 19 November 2025
- Published by Elsevier in Academic Radiology
- Vol. 33 (2) , 569-585
Comparing Mean-anchored Generalized Linear Binning with Established Methods to Quantify Xenon-129 Ventilation Defect Percentage
- 19 November 2025
- Published by Elsevier in Academic Radiology
- Vol. 33 (2) , 569-585
Comparing Mean-anchored Generalized Linear Binning with Established Methods to Quantify Xenon-129 Ventilation Defect Percentage
- 15 October 2025
- Published by Elsevier in Academic Radiology
- Vol. 33 (2) , 586-599
Evaluating Stack-of-Stars and FLORET 3D Ultrashort Echo Time MRI to Assess Structural Pathology in Cystic Fibrosis Lung Disease
- 15 October 2025
- Published by Elsevier in Academic Radiology
- Vol. 33 (2) , 586-599
Evaluating Stack-of-Stars and FLORET 3D Ultrashort Echo Time MRI to Assess Structural Pathology in Cystic Fibrosis Lung Disease
- 1 October 2025
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 7 (5) , e240574
Optimizing Xenon 129 Ventilation MRI in Cystic Fibrosis with Spiral Imaging and Flip-Angle Correction
Faster and more accurate xenon 129 ventilation MRI was achieved in individuals with cystic fibrosis by combining two-dimensional spiral acquisition, keyhole-based flip-angle correction, and median-anchored generalized linear binning calibrated to normative data from healthy controls.
- 1 October 2025
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 7 (5) , e240574
Optimizing Xenon 129 Ventilation MRI in Cystic Fibrosis with Spiral Imaging and Flip-Angle Correction
Faster and more accurate xenon 129 ventilation MRI was achieved in individuals with cystic fibrosis by combining two-dimensional spiral acquisition, keyhole-based flip-angle correction, and median-anchored generalized linear binning calibrated to normative data from healthy controls.
- 25 September 2025
- Published by Oxford University Press (OUP) in Annals of the American Thoracic Society
- Vol. 23 (2) , 303-307
Xenon-129 magnetic resonance imaging detects ongoing ventilation improvements in people with cystic fibrosis receiving highly effective modulator therapy
- 25 September 2025
- Published by Oxford University Press (OUP) in Annals of the American Thoracic Society
- Vol. 23 (2) , 303-307
Xenon-129 magnetic resonance imaging detects ongoing ventilation improvements in people with cystic fibrosis receiving highly effective modulator therapy
- Open Access
- 14 August 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (1) , 138-156
Comparative evaluation of supervised and unsupervised deep learning strategies for denoising hyperpolarized 129 Xe lung MRI
Purpose: Reduced signal‐to‐noise ratio (SNR) in hyperpolarized 129 Xe MR images can affect accurate quantification for research and diagnostic evaluations. Thus, this study explores the application of supervised deep learning (DL) denoising, traditional (Trad) and Noise2Noise (N2N) and unsupervised Noise2void (N2V) approaches for 129 Xe MR imaging. Methods: The DL denoising frameworks were trained and tested on 952 129 Xe MRI data sets (421 ventilation, 125 diffusion‐weighted, and 406 gas‐exchange acquisitions) from healthy subjects and participants with cardiopulmonary conditions and compared with the block matching 3D denoising technique. Evaluation involved mean signal, noise standard deviation (SD), SNR, and sharpness. Ventilation defect percentage (VDP), apparent diffusion coefficient (ADC), membrane uptake, red blood cell (RBC) transfer, and RBC:Membrane were also evaluated for ventilation, diffusion, and gas‐exchange images, respectively. Results: Denoising methods significantly reduced noise SDs and enhanced SNR ( p < 0.05) across all imaging types. Traditional ventilation model (Trad vent ) improved sharpness in ventilation images but underestimated VDP (bias = −1.37%) relative to raw images, whereas N2N vent overestimated VDP (bias = +1.88%). Block matching 3D and N2V vent showed minimal VDP bias (≤ 0.35%). Denoising significantly reduced ADC mean and SD ( p < 0.05, bias ≤ − 0.63 × 10 −2 ). The values of Trad vent and N2N vent increased mean membrane and RBC ( p < 0.001) with no change in RBC:Membrane. Denoising also reduced SDs of all gas‐exchange metrics ( p < 0.01). Conclusions: Low SNR may impair the potential of 129 Xe MRI for clinical diagnosis and lung function assessment. The evaluation of supervised and unsupervised DL denoising methods enhanced 129 Xe imaging quality, offering promise for improved clinical interpretation and diagnosis.
- 14 August 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 95 (1) , 138-156
Open AccessComparative evaluation of supervised and unsupervised deep learning strategies for denoising hyperpolarized 129 Xe lung MRI
Purpose: Reduced signal‐to‐noise ratio (SNR) in hyperpolarized 129 Xe MR images can affect accurate quantification for research and diagnostic evaluations. Thus, this study explores the application of supervised deep learning (DL) denoising, traditional (Trad) and Noise2Noise (N2N) and unsupervised Noise2void (N2V) approaches for 129 Xe MR imaging. Methods: The DL denoising frameworks were trained and tested on 952 129 Xe MRI data sets (421 ventilation, 125 diffusion‐weighted, and 406 gas‐exchange acquisitions) from healthy subjects and participants with cardiopulmonary conditions and compared with the block matching 3D denoising technique. Evaluation involved mean signal, noise standard deviation (SD), SNR, and sharpness. Ventilation defect percentage (VDP), apparent diffusion coefficient (ADC), membrane uptake, red blood cell (RBC) transfer, and RBC:Membrane were also evaluated for ventilation, diffusion, and gas‐exchange images, respectively. Results: Denoising methods significantly reduced noise SDs and enhanced SNR ( p < 0.05) across all imaging types. Traditional ventilation model (Trad vent ) improved sharpness in ventilation images but underestimated VDP (bias = −1.37%) relative to raw images, whereas N2N vent overestimated VDP (bias = +1.88%). Block matching 3D and N2V vent showed minimal VDP bias (≤ 0.35%). Denoising significantly reduced ADC mean and SD ( p < 0.05, bias ≤ − 0.63 × 10 −2 ). The values of Trad vent and N2N vent increased mean membrane and RBC ( p < 0.001) with no change in RBC:Membrane. Denoising also reduced SDs of all gas‐exchange metrics ( p < 0.01). Conclusions: Low SNR may impair the potential of 129 Xe MRI for clinical diagnosis and lung function assessment. The evaluation of supervised and unsupervised DL denoising methods enhanced 129 Xe imaging quality, offering promise for improved clinical interpretation and diagnosis.
- Open Access
- 31 October 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (3) , 1220-1237
129Xe Image Processing Pipeline: An open‐source, graphical user interface application for the analysis of hyperpolarized 129Xe MRI
Purpose: Hyperpolarized 129Xe MRI presents opportunities to assess regional pulmonary microstructure and function. Ongoing advancements in hardware, sequences, and image processing have helped it become increasingly adopted for both research and clinical use. As the number of applications and users increase, standardization becomes crucial. To that end, this study developed an executable, open‐source 129Xe image processing pipeline (XIPline) to provide a user‐friendly, graphical user interface‐based analysis pipeline to analyze and visualize 129Xe MR data, including scanner calibration, ventilation, diffusion‐weighted, and gas exchange images.Methods: The customizable XIPline is designed in MATLAB to analyze data from all three major scanner platforms. Calibration data is processed to calculate optimal flip angle and determine129Xe frequency offset. Data processing includes loading, reconstructing, registering, segmenting, and post‐processing images. Ventilation analysis incorporates three common algorithms to calculate ventilation defect percentage and novel techniques to assess defect distribution and ventilation texture. Diffusion analysis features ADC mapping, modified linear binning to account for ADC age‐dependence, and common diffusion morphometry methods. Gas exchange processing uses a generalized linear binning for data acquired using 1‐point Dixon imaging.Results: The XIPline workflow is demonstrated using analysis from representative calibration, ventilation, diffusion, and gas exchange data.Conclusion: The application will reduce redundant effort when implementing new techniques across research sites by providing an open‐source framework for developers. In its current form, it offers a robust and adaptable platform for 129Xe MRI analysis to ensure methodological consistency, transparency, and support for collaborative research across multiple sites and MRI manufacturers.
- 31 October 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (3) , 1220-1237
Open Access129Xe Image Processing Pipeline: An open‐source, graphical user interface application for the analysis of hyperpolarized 129Xe MRI
Purpose: Hyperpolarized 129Xe MRI presents opportunities to assess regional pulmonary microstructure and function. Ongoing advancements in hardware, sequences, and image processing have helped it become increasingly adopted for both research and clinical use. As the number of applications and users increase, standardization becomes crucial. To that end, this study developed an executable, open‐source 129Xe image processing pipeline (XIPline) to provide a user‐friendly, graphical user interface‐based analysis pipeline to analyze and visualize 129Xe MR data, including scanner calibration, ventilation, diffusion‐weighted, and gas exchange images.Methods: The customizable XIPline is designed in MATLAB to analyze data from all three major scanner platforms. Calibration data is processed to calculate optimal flip angle and determine129Xe frequency offset. Data processing includes loading, reconstructing, registering, segmenting, and post‐processing images. Ventilation analysis incorporates three common algorithms to calculate ventilation defect percentage and novel techniques to assess defect distribution and ventilation texture. Diffusion analysis features ADC mapping, modified linear binning to account for ADC age‐dependence, and common diffusion morphometry methods. Gas exchange processing uses a generalized linear binning for data acquired using 1‐point Dixon imaging.Results: The XIPline workflow is demonstrated using analysis from representative calibration, ventilation, diffusion, and gas exchange data.Conclusion: The application will reduce redundant effort when implementing new techniques across research sites by providing an open‐source framework for developers. In its current form, it offers a robust and adaptable platform for 129Xe MRI analysis to ensure methodological consistency, transparency, and support for collaborative research across multiple sites and MRI manufacturers.
- Open Access
- 11 June 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (4) , 1363-1375
A decay‐modeled compressed sensing reconstruction approach for non‐Cartesian hyperpolarized 129Xe MRI
Purpose: Hyperpolarized 129Xe MRI benefits from non‐Cartesian acquisitions that sample k‐space efficiently and rapidly. However, their reconstructions are complex and burdened by decay processes unique to hyperpolarized gas. Currently used gridded reconstructions are prone to artifacts caused by magnetization decay and are ill‐suited for undersampling. We present a compressed sensing (CS) reconstruction approach that incorporates magnetization decay in the forward model, thereby producing images with increased sharpness and contrast, even in undersampled data.Methods: Radio‐frequency, T1, and decay processes were incorporated into the forward model and solved using iterative methods including CS. The decay‐modeled reconstruction was validated in simulations and then tested in 2D/3D‐spiral ventilation and 3D‐radial gas‐exchange MRI. Quantitative metrics including apparent‐SNR and sharpness were compared between gridded, CS, and twofold undersampled CS reconstructions. Observations were validated in gas‐exchange data collected from 15 healthy and 25 post‐hematopoietic‐stem‐cell‐transplant participants.Results: CS reconstructions in simulations yielded images with threefold increases in accuracy. CS increased sharpness and contrast for ventilation in vivo imaging and showed greater accuracy for undersampled acquisitions. CS improved gas‐exchange imaging, particularly in the dissolved‐phase where apparent‐SNR improved, and structure was made discernable. Finally, CS showed repeatability in important global gas‐exchange metrics including median dissolved‐gas signal ratio and median angle between real/imaginary components.Conclusion: A non‐Cartesian CS reconstruction approach that incorporates hyperpolarized 129Xe decay processes is presented. This approach enables improved image sharpness, contrast, and overall image quality in addition to up‐to threefold undersampling. This contribution benefits all hyperpolarized gas MRI through improved accuracy and decreased scan durations.
- 11 June 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (4) , 1363-1375
Open AccessA decay‐modeled compressed sensing reconstruction approach for non‐Cartesian hyperpolarized 129Xe MRI
Purpose: Hyperpolarized 129Xe MRI benefits from non‐Cartesian acquisitions that sample k‐space efficiently and rapidly. However, their reconstructions are complex and burdened by decay processes unique to hyperpolarized gas. Currently used gridded reconstructions are prone to artifacts caused by magnetization decay and are ill‐suited for undersampling. We present a compressed sensing (CS) reconstruction approach that incorporates magnetization decay in the forward model, thereby producing images with increased sharpness and contrast, even in undersampled data.Methods: Radio‐frequency, T1, and decay processes were incorporated into the forward model and solved using iterative methods including CS. The decay‐modeled reconstruction was validated in simulations and then tested in 2D/3D‐spiral ventilation and 3D‐radial gas‐exchange MRI. Quantitative metrics including apparent‐SNR and sharpness were compared between gridded, CS, and twofold undersampled CS reconstructions. Observations were validated in gas‐exchange data collected from 15 healthy and 25 post‐hematopoietic‐stem‐cell‐transplant participants.Results: CS reconstructions in simulations yielded images with threefold increases in accuracy. CS increased sharpness and contrast for ventilation in vivo imaging and showed greater accuracy for undersampled acquisitions. CS improved gas‐exchange imaging, particularly in the dissolved‐phase where apparent‐SNR improved, and structure was made discernable. Finally, CS showed repeatability in important global gas‐exchange metrics including median dissolved‐gas signal ratio and median angle between real/imaginary components.Conclusion: A non‐Cartesian CS reconstruction approach that incorporates hyperpolarized 129Xe decay processes is presented. This approach enables improved image sharpness, contrast, and overall image quality in addition to up‐to threefold undersampling. This contribution benefits all hyperpolarized gas MRI through improved accuracy and decreased scan durations.
- Open Access
- 31 January 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (3) , 967-981
Analytical corrections for B1‐inhomogeneity and signal decay in multi‐slice 2D spiral hyperpolarized 129Xe MRI using keyhole reconstruction
Purpose: Hyperpolarized xenon MRI suffers from heterogeneous coil bias and magnetization decay that obscure pulmonary abnormalities. Non‐physiological signal variability can be mitigated by measuring and mapping the nominal flip angle, and by rescaling the images to correct for signal bias and decay. While flip angle maps can be calculated from sequentially acquired images, scan time and breath‐hold duration are doubled. Here, we exploit the low‐frequency oversampling of 2D‐spiral and keyhole reconstruction to measure flip angle maps from a single acquisition.Methods: Flip angle maps were calculated from two images generated from a single dataset using keyhole reconstructions and a Bloch‐equation–based model suitable for hyperpolarized substances. Artifacts resulting from acquisition and reconstruction schemes (e.g., keyhole reconstruction radius, slice‐selection profile, spiral‐ordering, and oversampling) were assessed using point‐spread functions. Simulated flip angle maps generated using keyhole reconstruction were compared against the paired‐image approach using RMS error (RMSE). Finally, feasibility was demonstrated for in vivo xenon ventilation imaging.Results: Simulations demonstrated accurate flip angle maps and B1‐inhomogeneity correction can be generated with only 1.25‐fold central‐oversampling and keyhole reconstruction radius = 5% (RMSE = 0.460°). These settings also generated accurate flip angle maps in a healthy control (RSME = 0.337°) and a person with cystic fibrosis (RMSE = 0.404°) in as little as 3.3 s.Conclusion: Regional lung ventilation images with reduced impact of B1‐inhomogeneity can be acquired rapidly by combining 2D‐spiral acquisition, Bloch‐equation–based modeling, and keyhole reconstruction. This approach will be especially useful for breath‐hold studies where short scan durations are necessary, such as dynamic imaging and applications in children or people with severely compromised respiratory function.
- 31 January 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (3) , 967-981
Open AccessAnalytical corrections for B1‐inhomogeneity and signal decay in multi‐slice 2D spiral hyperpolarized 129Xe MRI using keyhole reconstruction
Purpose: Hyperpolarized xenon MRI suffers from heterogeneous coil bias and magnetization decay that obscure pulmonary abnormalities. Non‐physiological signal variability can be mitigated by measuring and mapping the nominal flip angle, and by rescaling the images to correct for signal bias and decay. While flip angle maps can be calculated from sequentially acquired images, scan time and breath‐hold duration are doubled. Here, we exploit the low‐frequency oversampling of 2D‐spiral and keyhole reconstruction to measure flip angle maps from a single acquisition.Methods: Flip angle maps were calculated from two images generated from a single dataset using keyhole reconstructions and a Bloch‐equation–based model suitable for hyperpolarized substances. Artifacts resulting from acquisition and reconstruction schemes (e.g., keyhole reconstruction radius, slice‐selection profile, spiral‐ordering, and oversampling) were assessed using point‐spread functions. Simulated flip angle maps generated using keyhole reconstruction were compared against the paired‐image approach using RMS error (RMSE). Finally, feasibility was demonstrated for in vivo xenon ventilation imaging.Results: Simulations demonstrated accurate flip angle maps and B1‐inhomogeneity correction can be generated with only 1.25‐fold central‐oversampling and keyhole reconstruction radius = 5% (RMSE = 0.460°). These settings also generated accurate flip angle maps in a healthy control (RSME = 0.337°) and a person with cystic fibrosis (RMSE = 0.404°) in as little as 3.3 s.Conclusion: Regional lung ventilation images with reduced impact of B1‐inhomogeneity can be acquired rapidly by combining 2D‐spiral acquisition, Bloch‐equation–based modeling, and keyhole reconstruction. This approach will be especially useful for breath‐hold studies where short scan durations are necessary, such as dynamic imaging and applications in children or people with severely compromised respiratory function.