Nenad Milošević
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nenad Milošević has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
K. D. Maglić
“Vinča” Institute of Nuclear Sciences
4 shared publications- Ivana Nikolić
Vinca Institute of Nuclear Sciences - National Institute of the Republic of Serbia, University of Belgrade, Belgrade, Serbia
3 shared publications Ivana Nikolić
Univ Belgrade, Inst Nucl Sci Vinca, POB 522, Belgrade 11001, Serbia
2 shared publicationsKosta Maglić
Institute for Nuclear Sciences Vincha , P.O. Box 522, Belgrade, 11001, Yugoslavia
2 shared publicationsM. Raynaud
Institut National des Sciences Appliquées de Lyon, CETHIL, UMR CNRS 5008, 20 Av. A. Einstein, 69621 Villeurbanne Cedex, France
2 shared publications- Marijana M. Terzić
Institute of Nuclear Sciences Vinča, Belgrade
2 shared publications
Latest Publications
- 1 January 2024
- Published by Old City Publishing, Inc in High Temperatures-High Pressures
- Vol. 53 (3) , 271-288
Data reduction and uncertainty assessment of the direct pulse heating technique with both contact and radiance temperature measurements
- 1 January 2024
- Published by Old City Publishing, Inc in High Temperatures-High Pressures
- Vol. 53 (3) , 271-288
Data reduction and uncertainty assessment of the direct pulse heating technique with both contact and radiance temperature measurements
- 1 January 2023
- Published by Old City Publishing, Inc in High Temperatures-High Pressures
- Vol. 52 (5) , 353-364
Thermophysical properties of the molybdenum alloy TZM (Mo-0.5Ti-0.08Zr-0.02C) over a wide temperature range
- 1 January 2023
- Published by Old City Publishing, Inc in High Temperatures-High Pressures
- Vol. 52 (5) , 353-364
Thermophysical properties of the molybdenum alloy TZM (Mo-0.5Ti-0.08Zr-0.02C) over a wide temperature range
- Open Access
- 1 January 2022
- Published by National Library of Serbia in Thermal Science
- Vol. 26 (4 Part B) , 3619-3626
Temperature non-uniformity due to heat conduction and radiation in the pulse calorimetry technique
The paper presents an assessment of the unwanted temperature non-uniformity found in high temperature applications of the pulse calorimetry technique. Specimens in the form of a solid cylinder undergoes fast electrical heating and an intense heat radiation at high temperatures, coupled with the heat conduction the specimens? cold ends, make them having a highly non-uniform temperature distribution, both in their radial and axial directions. By using finite element method simulations of a typical pulse calorimetry experiment, the temperature non-uniformity across the specimen diameter and along the specimen effective length has been estimated for different specimen dimensions and materials, as well as for different heating rates. The obtained results suggest that an optimization of experimental parameters, such as the specimen diameter, specimen total and effective length and heating rate, is needed for minimization of the temperature non-uniformity effect.
- 1 January 2022
- Published by National Library of Serbia in Thermal Science
- Vol. 26 (4 Part B) , 3619-3626
Open AccessTemperature non-uniformity due to heat conduction and radiation in the pulse calorimetry technique
The paper presents an assessment of the unwanted temperature non-uniformity found in high temperature applications of the pulse calorimetry technique. Specimens in the form of a solid cylinder undergoes fast electrical heating and an intense heat radiation at high temperatures, coupled with the heat conduction the specimens? cold ends, make them having a highly non-uniform temperature distribution, both in their radial and axial directions. By using finite element method simulations of a typical pulse calorimetry experiment, the temperature non-uniformity across the specimen diameter and along the specimen effective length has been estimated for different specimen dimensions and materials, as well as for different heating rates. The obtained results suggest that an optimization of experimental parameters, such as the specimen diameter, specimen total and effective length and heating rate, is needed for minimization of the temperature non-uniformity effect.
- Open Access
- 21 June 2021
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 147 (8) , 4935-4943
Application of the subsecond calorimetry technique with both contact and radiance temperature measurements: case study on solid phase tungsten at very high temperatures
This work presents an application of the subsecond calorimetry technique at very high temperatures, which uses both contact and radiance temperature measurements. This technique is normally applied for thermophysical characterization of high temperature solid phase materials in the temperature range from ambient up to about 2600 K, which is the limit of the standard tungsten-rhenium thermocouple use. Simultaneously with contact temperature measurements, noncontact or radiance temperature detection may be performed in the approximate range from 1000 to 2600 K in order to acquire information on spectral normal emissivity of specimen under test. In this study, however, the specimen is heated above 2600 K and, then, the temperature is measured only by the noncontact mean. In the extended temperature range, the obtained values of the spectral normal emissivity are extrapolated for each experimental run, which makes possible a conversion from radiance to absolute specimen temperature. In order to test this application, a pure polycrystalline specimen of tungsten in the form of rod, 3 mm in diameter and 200 mm in length, has been used. The specimen has been heated in vacuum environment of about 10–4 mbar by short pulses of high DC current with a gradual increase of the total heating time from about 0.5–2.5 s. During the specimen heating and the beginning of the cooling period, four sets of experimental data have been recorded and reduced by using the corresponding data reduction procedure. Obtained results of specific heat and specific electrical resistivity from ambient to 3700 K, total hemispherical emissivity from 1000 to 3700 K and spectral normal emissivity from 1000 to 2600 K (extrapolated to 3700 K) are presented, discussed and compared with related literature data.
- 21 June 2021
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 147 (8) , 4935-4943
Open AccessApplication of the subsecond calorimetry technique with both contact and radiance temperature measurements: case study on solid phase tungsten at very high temperatures
This work presents an application of the subsecond calorimetry technique at very high temperatures, which uses both contact and radiance temperature measurements. This technique is normally applied for thermophysical characterization of high temperature solid phase materials in the temperature range from ambient up to about 2600 K, which is the limit of the standard tungsten-rhenium thermocouple use. Simultaneously with contact temperature measurements, noncontact or radiance temperature detection may be performed in the approximate range from 1000 to 2600 K in order to acquire information on spectral normal emissivity of specimen under test. In this study, however, the specimen is heated above 2600 K and, then, the temperature is measured only by the noncontact mean. In the extended temperature range, the obtained values of the spectral normal emissivity are extrapolated for each experimental run, which makes possible a conversion from radiance to absolute specimen temperature. In order to test this application, a pure polycrystalline specimen of tungsten in the form of rod, 3 mm in diameter and 200 mm in length, has been used. The specimen has been heated in vacuum environment of about 10–4 mbar by short pulses of high DC current with a gradual increase of the total heating time from about 0.5–2.5 s. During the specimen heating and the beginning of the cooling period, four sets of experimental data have been recorded and reduced by using the corresponding data reduction procedure. Obtained results of specific heat and specific electrical resistivity from ambient to 3700 K, total hemispherical emissivity from 1000 to 3700 K and spectral normal emissivity from 1000 to 2600 K (extrapolated to 3700 K) are presented, discussed and compared with related literature data.
- 1 April 2019
- Published by American Institute of Aeronautics and Astronautics (AIAA) in Journal of Thermophysics and Heat Transfer
- Vol. 33 (2) , 300-308
Analytical Solution of a Generalized Two-Dimensional Model for Laser-Flash Thermal Diffusivity Measurements
This paper presents a two-dimensional model that generalizes the use of the laser flash method for thermal diffusivity measurements of homogeneous, opaque, and two-dimensional (2-D) anisotropic solid materials in the form of thin disk-shaped samples. The model employs partial central or annular pulse heating of the front sample side and a temperature detection over a generally decentralized circular surface on the rear or front sample side. A general analytical solution of related 2-D heat conduction problem with boundary and initial conditions that may exist in reality (such as radiation heat transfer between specimen surfaces and the environment, nonuniform pulse heating, finite pulse duration, and laser pulse penetration) is presented in a partial integral form. The solution for the transient temperature over the decentralized detection surface is transformed from a double integral to a single integral, which reduces the processing time in numerical computation. A simplified solution is given for the partial uniform pulse heating, rectangular pulse duration, and negligible laser pulse penetration depth. Following the simplified solution, four different applications of the presented model for the case of the rear-side temperature detection are described, together with an example of a related sensitivity analysis for the selected set of parametric values. The influence of the size and position of the detection surface on the transient temperature response is separately analyzed, and the results are presented in the last section of the paper.
- 1 April 2019
- Published by American Institute of Aeronautics and Astronautics (AIAA) in Journal of Thermophysics and Heat Transfer
- Vol. 33 (2) , 300-308
Analytical Solution of a Generalized Two-Dimensional Model for Laser-Flash Thermal Diffusivity Measurements
This paper presents a two-dimensional model that generalizes the use of the laser flash method for thermal diffusivity measurements of homogeneous, opaque, and two-dimensional (2-D) anisotropic solid materials in the form of thin disk-shaped samples. The model employs partial central or annular pulse heating of the front sample side and a temperature detection over a generally decentralized circular surface on the rear or front sample side. A general analytical solution of related 2-D heat conduction problem with boundary and initial conditions that may exist in reality (such as radiation heat transfer between specimen surfaces and the environment, nonuniform pulse heating, finite pulse duration, and laser pulse penetration) is presented in a partial integral form. The solution for the transient temperature over the decentralized detection surface is transformed from a double integral to a single integral, which reduces the processing time in numerical computation. A simplified solution is given for the partial uniform pulse heating, rectangular pulse duration, and negligible laser pulse penetration depth. Following the simplified solution, four different applications of the presented model for the case of the rear-side temperature detection are described, together with an example of a related sensitivity analysis for the selected set of parametric values. The influence of the size and position of the detection surface on the transient temperature response is separately analyzed, and the results are presented in the last section of the paper.
- Open Access
- 28 February 2017
- Published by United Association of Serbia for Quality UASQ in International Journal "Advanced Quality"
- Vol. 44 (3) , 29-31
DEVELOPMENT OF NEW TRACEABLE EUROPEAN CAPABILITIES IN THERMAL METROLOGY
This paper deals with a new European project in which the overall objective is to enhance the availability of facilities in the field of thermal metrology (e.g. high temperature contact thermometry, non-contact thermometry and thermo-physical properties of materials characterisation) in European emerging National Metrology Institutes (NMIs), where access to these types of facilities is currently limited.
- 28 February 2017
- Published by United Association of Serbia for Quality UASQ in International Journal "Advanced Quality"
- Vol. 44 (3) , 29-31
Open AccessDEVELOPMENT OF NEW TRACEABLE EUROPEAN CAPABILITIES IN THERMAL METROLOGY
This paper deals with a new European project in which the overall objective is to enhance the availability of facilities in the field of thermal metrology (e.g. high temperature contact thermometry, non-contact thermometry and thermo-physical properties of materials characterisation) in European emerging National Metrology Institutes (NMIs), where access to these types of facilities is currently limited.
- Open Access
- 1 January 2017
- Published by National Library of Serbia in Thermal Science
- Vol. 21 (3) , 1195-1202
Application and testing of a new simple experimental set-up for thermal conductivity measurements of liquids
Transient hot wire method is considered a reliable and precise technique for measuring the thermal conductivity of liquids. The present paper describes a new transient hot wire experimental set-up and its initial testing. The new apparatus was tested by performing thermal conductivity measurements on substances whose reference thermophysical properties data existed in literature, namely on pure toluene and double distilled deionized water. The values of thermal conductivity measured in the temperature range 25 to 45 ?C deviated +2.2% to +3% from the literature data, while the expanded measurement uncertainty was estimated to be ?4%.
- 1 January 2017
- Published by National Library of Serbia in Thermal Science
- Vol. 21 (3) , 1195-1202
Open AccessApplication and testing of a new simple experimental set-up for thermal conductivity measurements of liquids
Transient hot wire method is considered a reliable and precise technique for measuring the thermal conductivity of liquids. The present paper describes a new transient hot wire experimental set-up and its initial testing. The new apparatus was tested by performing thermal conductivity measurements on substances whose reference thermophysical properties data existed in literature, namely on pure toluene and double distilled deionized water. The values of thermal conductivity measured in the temperature range 25 to 45 ?C deviated +2.2% to +3% from the literature data, while the expanded measurement uncertainty was estimated to be ?4%.
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1752 (1) , 030002
Measurements of thermophysical properties of solids at the Institute VINČA
This paper presents the Metrological Laboratory for Thermophysical Quantities (MLTV) and its actual measurement possibilities. The MLTV is located in the Department of Thermal Engineering and Energy of the Institute of Nuclear Sciences VINČA in Serbia. It was founded in 1963, accredited by the National Accreditation Body in 2007 and became the national designated laboratory for thermophysical quantities and received the status of a EURAMET Associate Member in 2015. Today, the laboratory develops, maintains and disseminates traceability of different national standards, such as those for thermal conductivity of insulations and poorly conductive solid materials from 250 K to 350 K, thermal diffusivity of a large variety of solid materials from 200 K to 1450 K and specific heat and specific electrical resistivity from 250 K to 2400 K of electroconductive solid materials. Total hemispherical and spectral normal emissivity from 1200 K to 2400 K of electroconductive solid materials are also measured in the MLTV. The methods and experimental setups for the realization and measurement of all of these standards and quantities are described with corresponding examples.
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1752 (1) , 030002
Measurements of thermophysical properties of solids at the Institute VINČA
This paper presents the Metrological Laboratory for Thermophysical Quantities (MLTV) and its actual measurement possibilities. The MLTV is located in the Department of Thermal Engineering and Energy of the Institute of Nuclear Sciences VINČA in Serbia. It was founded in 1963, accredited by the National Accreditation Body in 2007 and became the national designated laboratory for thermophysical quantities and received the status of a EURAMET Associate Member in 2015. Today, the laboratory develops, maintains and disseminates traceability of different national standards, such as those for thermal conductivity of insulations and poorly conductive solid materials from 250 K to 350 K, thermal diffusivity of a large variety of solid materials from 200 K to 1450 K and specific heat and specific electrical resistivity from 250 K to 2400 K of electroconductive solid materials. Total hemispherical and spectral normal emissivity from 1200 K to 2400 K of electroconductive solid materials are also measured in the MLTV. The methods and experimental setups for the realization and measurement of all of these standards and quantities are described with corresponding examples.
- Open Access
- 1 January 2016
- Published by National Library of Serbia in Thermal Science
- Vol. 20 (suppl. 1) , 321-329
Development of a single-sided guarded hot plate apparatus for thermal conductivity measurements
This work presents the development of an experimental setup for measurements on of thermal conductivity of solid materials, such as ceramics, polymers, rubbers, glasses, biological materials, etc. whose thermal conductivity lies in the approximate range between 0.1 and 2 Wm-1K-1. The setup was designed on the principle of the single-sided guarded hot plate method. In order to find the optimal design for generation of traceable one-dimensional heat flux through an investigated 300?300 mm2 specimen, a numerical heat transfer FEM analysis was performed. The principal components of the measuring apparatus, such as hot plate with thermopile, cold plate and auxiliary hot plate were constructed according to the obtained results of simulations. Software for the control of experiment and data acquisition was developed using the LabVIEW programming environment.
- 1 January 2016
- Published by National Library of Serbia in Thermal Science
- Vol. 20 (suppl. 1) , 321-329
Open AccessDevelopment of a single-sided guarded hot plate apparatus for thermal conductivity measurements
This work presents the development of an experimental setup for measurements on of thermal conductivity of solid materials, such as ceramics, polymers, rubbers, glasses, biological materials, etc. whose thermal conductivity lies in the approximate range between 0.1 and 2 Wm-1K-1. The setup was designed on the principle of the single-sided guarded hot plate method. In order to find the optimal design for generation of traceable one-dimensional heat flux through an investigated 300?300 mm2 specimen, a numerical heat transfer FEM analysis was performed. The principal components of the measuring apparatus, such as hot plate with thermopile, cold plate and auxiliary hot plate were constructed according to the obtained results of simulations. Software for the control of experiment and data acquisition was developed using the LabVIEW programming environment.
- 14 April 2015
- Published by Walter de Gruyter GmbH in International Journal of Materials Research
- Vol. 106 (4) , 361-367
Thermophysical properties of solid phase ruthenium measured by the pulse calorimetry technique over a wide temperature range
This paper presents experimental results on four thermophysical properties of pure polycrystalline ruthenium samples over a wide temperature range. Specific heat capacity and specific electrical resistivity were measured from 250 to 2 500 K, while hemispherical total emissivity and normal spectral emissivity at 900 nm were measured from 1 300 to 2 500 K. All the properties were obtained by using the pulse calorimetry technique. The 200 mm long specimens were in the form of a thin rod, of about 3 mm in diameter. For necessary corrections, literature data on thermal linear expansion were applied. The results are compared with available literature data and discussed. The specific heat capacity and specific electrical resistivity measurements did not indicate any allotropic transformation of the samples over the entire temperature range.
- 14 April 2015
- Published by Walter de Gruyter GmbH in International Journal of Materials Research
- Vol. 106 (4) , 361-367
Thermophysical properties of solid phase ruthenium measured by the pulse calorimetry technique over a wide temperature range
This paper presents experimental results on four thermophysical properties of pure polycrystalline ruthenium samples over a wide temperature range. Specific heat capacity and specific electrical resistivity were measured from 250 to 2 500 K, while hemispherical total emissivity and normal spectral emissivity at 900 nm were measured from 1 300 to 2 500 K. All the properties were obtained by using the pulse calorimetry technique. The 200 mm long specimens were in the form of a thin rod, of about 3 mm in diameter. For necessary corrections, literature data on thermal linear expansion were applied. The results are compared with available literature data and discussed. The specific heat capacity and specific electrical resistivity measurements did not indicate any allotropic transformation of the samples over the entire temperature range.