Daud Hossain Khan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Daud Hossain Khan has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Nitin Agrawal
Krasnow Institute for Advanced Study, George Mason University, Fairfax, VA 22030, USA
2 shared publications - Aarthi Narayanan
Department of Biology, College of Science, George Mason University, Fairfax, VA 22030, USA
1 shared publication - Ashish Aphale
Department of Biomedical Engineering, University of Bridgeport, CT, 06604 USA
1 shared publication - Brian Roberts
Leidos Health Sciences, 5202 Presidents Court, Suite 110, Frederick, MD 21704, USA
1 shared publication Catherine M. Bollard
George Washington Cancer Center, George Washington University, Washington, DC 20052, United States
1 shared publication- Forrest Keck
National Center for Biodefense and Infectious Diseases, George Mason University, Manassas, VA 20110, USA
1 shared publication
Latest Publications
- 19 February 2019
- Published by American Chemical Society (ACS) in Bioconjugate Chemistry
- Vol. 30 (3) , 552-560
Designing Magnetically Responsive Biohybrids Composed of Cord Blood-Derived Natural Killer Cells and Iron Oxide Nanoparticles
- 19 February 2019
- Published by American Chemical Society (ACS) in Bioconjugate Chemistry
- Vol. 30 (3) , 552-560
Designing Magnetically Responsive Biohybrids Composed of Cord Blood-Derived Natural Killer Cells and Iron Oxide Nanoparticles
- Open Access
Mitochondrial-Directed Antioxidant Reduces Microglial-Induced Inflammation in Murine In Vitro Model of TC-83 Infection
Venezuelan equine encephalitis virus (VEEV) is an arbovirus that is associated with robust inflammation that contributes to neurodegenerative phenotypes. In addition to triggering central nervous system (CNS) inflammation, VEEV will also induce mitochondrial dysfunction, resulting in increased cellular apoptosis. In this study, we utilize the TC-83 strain of VEEV to determine the role of mitochondrial oxidative stress in mediating inflammation elicited by murine brain microglial cells. Using an in vitro model, we show that murine microglia are susceptible to TC-83 infection, and that these cells undergo mitochondrial stress as the result of infection. We also indicate that bystander microglia contribute more significantly to the overall inflammatory load than directly infected microglia. Use of a mitochondrial targeted antioxidant, mitoquinone mesylate, greatly reduced the pro-inflammatory cytokines released by both direct infected and bystander microglia. Our data suggest that release of interleukin-1β, a key instigator of neuroinflammation during VEEV infection, may be the direct result of accumulating mitochondrial stress. This data improves our understanding inflammation elicited by murine microglia and will aid in the development of more accurate in vitro and in vivo murine model of VEEV-induced neuroinflammation.
Open AccessMitochondrial-Directed Antioxidant Reduces Microglial-Induced Inflammation in Murine In Vitro Model of TC-83 Infection
Venezuelan equine encephalitis virus (VEEV) is an arbovirus that is associated with robust inflammation that contributes to neurodegenerative phenotypes. In addition to triggering central nervous system (CNS) inflammation, VEEV will also induce mitochondrial dysfunction, resulting in increased cellular apoptosis. In this study, we utilize the TC-83 strain of VEEV to determine the role of mitochondrial oxidative stress in mediating inflammation elicited by murine brain microglial cells. Using an in vitro model, we show that murine microglia are susceptible to TC-83 infection, and that these cells undergo mitochondrial stress as the result of infection. We also indicate that bystander microglia contribute more significantly to the overall inflammatory load than directly infected microglia. Use of a mitochondrial targeted antioxidant, mitoquinone mesylate, greatly reduced the pro-inflammatory cytokines released by both direct infected and bystander microglia. Our data suggest that release of interleukin-1β, a key instigator of neuroinflammation during VEEV infection, may be the direct result of accumulating mitochondrial stress. This data improves our understanding inflammation elicited by murine microglia and will aid in the development of more accurate in vitro and in vivo murine model of VEEV-induced neuroinflammation.
- Open Access
- 18 October 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 13487
Rapid Generation and Detection of Biomimetic Oxygen Concentration Gradients In Vitro
Hypoxic regions exist within most solid tumors and often lead to altered cellular metabolism, metastasis, and drug resistance. Reliable generation and detection of biomimetic gaseous gradientsin vitrois challenging due to low spatiotemporal resolution and poor longevity of gradients utilizing microfluidic techniques. Here, we present a novel and simplistic approach for producing gradients of dissolved oxygen (DO) within a lab-on-a-chip platform. Linear and stable DO gradients with high spatial resolution are established by introducing pre-gassed media into the gradient generating network. An underlying platinum(ii) octaethlporphyrin ketone (PtOEPK) based sensor layer allows parallel detection of oxygen. A thin 3-sided glass coating on the inner channel walls prevents multi-directional diffusion of ambient oxygen across PDMS preserving the gradient resolution and stability. Viability analysis of normal mammary epithelial cells (MCF-12A) under oxygen gradients revealed 70% mortality after 6 hours of hypoxic exposure. Biological applicability of the platform was further validated by demonstrating increase in endoplasmic reticulum stress of MDA-MB-468 cells with time and with increasing oxygen tension. The unique ability to establish parallel or opposing gradients of gases and chemicals offers the potential for a wide range of applications in therapeutic development, and fundamental understanding of cellular behavior during hypoxia.
- 18 October 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 13487
Open AccessRapid Generation and Detection of Biomimetic Oxygen Concentration Gradients In Vitro
Hypoxic regions exist within most solid tumors and often lead to altered cellular metabolism, metastasis, and drug resistance. Reliable generation and detection of biomimetic gaseous gradientsin vitrois challenging due to low spatiotemporal resolution and poor longevity of gradients utilizing microfluidic techniques. Here, we present a novel and simplistic approach for producing gradients of dissolved oxygen (DO) within a lab-on-a-chip platform. Linear and stable DO gradients with high spatial resolution are established by introducing pre-gassed media into the gradient generating network. An underlying platinum(ii) octaethlporphyrin ketone (PtOEPK) based sensor layer allows parallel detection of oxygen. A thin 3-sided glass coating on the inner channel walls prevents multi-directional diffusion of ambient oxygen across PDMS preserving the gradient resolution and stability. Viability analysis of normal mammary epithelial cells (MCF-12A) under oxygen gradients revealed 70% mortality after 6 hours of hypoxic exposure. Biological applicability of the platform was further validated by demonstrating increase in endoplasmic reticulum stress of MDA-MB-468 cells with time and with increasing oxygen tension. The unique ability to establish parallel or opposing gradients of gases and chemicals offers the potential for a wide range of applications in therapeutic development, and fundamental understanding of cellular behavior during hypoxia.
- 1 March 2017
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 89, 326-333
Interactions between avidin and graphene for development of a biosensing platform
- 1 March 2017
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 89, 326-333
Interactions between avidin and graphene for development of a biosensing platform