James Smalley
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
James Smalley has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
Baomin Xin
Bristol-Myers Squibb
4 shared publicationsDenise Grimm
Bristol-Myers Squibb Research & Development P.O. Box 5400
2 shared publications- Dieter M. Drexler
Bristol-Myers Squibb, Wallingford, CT, USA
2 shared publications - Ellen K. Kick
Bristol Myers Squibb
2 shared publications Glenn H. Cantor
Bristol-Myers Squibb Research & Development P.O. Box 5400
2 shared publicationsJacek Ostrowski
Bristol-Myers Squibb Research & Development P.O. Box 5400
2 shared publications
Latest Publications
- Open Access
- 27 May 2019
- Published by Wiley in Pharmacology Research & Perspectives
- Vol. 7 (3) , e00488
Application of ultrasound‐guided cholecystocentesis to the evaluation of the metabolite profiling in bile of dogs and cynomolgus monkeys
In this study, we describe a novel approach for collecting bile from dogs and cynomolgus monkeys for metabolite profiling, ultrasound‐guided cholecystocentesis (UCC). Sampling bile by UCC twice within 24 hours was well tolerated by dogs and monkeys. In studies with atorvastatin (ATV) the metabolite profiles were similar in bile obtained through UCC and from bile duct‐cannulated (BDC) dogs. Similar results were observed in UCC and BDC monkeys as well. In both monkey and dog, the primary metabolic pathway observed for ATV was oxidative metabolism. The 2‐hydroxy‐ and 4‐hydroxyatorvastatin metabolites were the major oxidation products, which is consistent with previously published metabolite profiles. S‐cysteine and glucuronide conjugates were also observed. UCC offers a viable alternative to bile duct cannulation for collection of bile for metabolite profiling of compounds that undergo biliary excretion, given the similar metabolite profiles in bile obtained via each method. Use of UCC for metabolite profiling may reduce the need for studies using BDC animals, a resource‐intensive model.
- 27 May 2019
- Published by Wiley in Pharmacology Research & Perspectives
- Vol. 7 (3) , e00488
Open AccessApplication of ultrasound‐guided cholecystocentesis to the evaluation of the metabolite profiling in bile of dogs and cynomolgus monkeys
In this study, we describe a novel approach for collecting bile from dogs and cynomolgus monkeys for metabolite profiling, ultrasound‐guided cholecystocentesis (UCC). Sampling bile by UCC twice within 24 hours was well tolerated by dogs and monkeys. In studies with atorvastatin (ATV) the metabolite profiles were similar in bile obtained through UCC and from bile duct‐cannulated (BDC) dogs. Similar results were observed in UCC and BDC monkeys as well. In both monkey and dog, the primary metabolic pathway observed for ATV was oxidative metabolism. The 2‐hydroxy‐ and 4‐hydroxyatorvastatin metabolites were the major oxidation products, which is consistent with previously published metabolite profiles. S‐cysteine and glucuronide conjugates were also observed. UCC offers a viable alternative to bile duct cannulation for collection of bile for metabolite profiling of compounds that undergo biliary excretion, given the similar metabolite profiles in bile obtained via each method. Use of UCC for metabolite profiling may reduce the need for studies using BDC animals, a resource‐intensive model.
- Open Access
- 23 October 2016
- Published by American Chemical Society (ACS) in ACS Medicinal Chemistry Letters
- Vol. 7 (12) , 1207-1212
Discovery of Highly Potent Liver X Receptor β Agonists
Introducing a uniquely substituted phenyl sulfone into a series of biphenyl imidazole liver X receptor (LXR) agonists afforded a dramatic potency improvement for induction of ATP binding cassette transporters, ABCA1 and ABCG1, in human whole blood. The agonist series demonstrated robust LXRβ activity (>70%) with low partial LXRα agonist activity (in vitro properties, excellent pharmacokinetic parameters, and a favorable lipid profile.
- 23 October 2016
- Published by American Chemical Society (ACS) in ACS Medicinal Chemistry Letters
- Vol. 7 (12) , 1207-1212
Open AccessDiscovery of Highly Potent Liver X Receptor β Agonists
Introducing a uniquely substituted phenyl sulfone into a series of biphenyl imidazole liver X receptor (LXR) agonists afforded a dramatic potency improvement for induction of ATP binding cassette transporters, ABCA1 and ABCG1, in human whole blood. The agonist series demonstrated robust LXRβ activity (>70%) with low partial LXRα agonist activity (in vitro properties, excellent pharmacokinetic parameters, and a favorable lipid profile.
- 1 February 2015
- Published by Elsevier in The Journal of Pharmacology and Experimental Therapeutics
- Vol. 352 (2) , 305-314
Pharmacological Characterization of a Novel Liver X Receptor Agonist with Partial LXRα Activity and a Favorable Window in Nonhuman Primates
Liver X Receptors (LXRs) α and β are nuclear hormone receptors that regulate multiple genes involved in reverse cholesterol transport (RCT) and are potential drug targets for atherosclerosis. However, full pan agonists also activate lipogenic genes, resulting in elevated plasma and hepatic lipids. We report the pharmacology of BMS-779788 [2-(2-(1-(2-chlorophenyl)-1-methylethyl)-1-(3′-(methylsulfonyl)-4-biphenylyl)-1H-imidazol-4-yl)-2-propanol], a potent partial LXR agonist with LXRβ selectivity, which has an improved therapeutic window in the cynomolgus monkey compared with a full pan agonist. BMS-779788 induced LXR target genes in blood in vivo with an EC50 = 610 nM, a value similar to its in vitro blood gene induction potency. BMS-779788 was 29- and 12-fold less potent than the full agonist T0901317 in elevating plasma triglyceride and LDL cholesterol, respectively, with similar results for plasma cholesteryl ester transfer protein and apolipoprotein B. However, ABCA1 and ABCG1 mRNA inductions in blood, which are critical for RCT, were comparable. Increased liver triglyceride was observed after 7-day treatment with BMS-779788 at the highest dose tested and was nearly identical to the dose response for plasma triglyceride, consistent with the central role of liver LXR in these lipogenic effects. Dose-dependent increases in biliary cholesterol and decreases in phospholipid and bile acid occurred in BMS-779788–treated animals, similar to LXR agonist effects reported in mouse. In summary, BMS-779788, a partial LXRβ selective agonist, has decreased lipogenic potential compared with a full pan agonist in cynomolgus monkeys, with similar potency in the induction of genes known to stimulate RCT. This provides support in nonhuman primates for improving LXR agonist therapeutic windows by limiting LXRα activity.
- 1 February 2015
- Published by Elsevier in The Journal of Pharmacology and Experimental Therapeutics
- Vol. 352 (2) , 305-314
Pharmacological Characterization of a Novel Liver X Receptor Agonist with Partial LXRα Activity and a Favorable Window in Nonhuman Primates
Liver X Receptors (LXRs) α and β are nuclear hormone receptors that regulate multiple genes involved in reverse cholesterol transport (RCT) and are potential drug targets for atherosclerosis. However, full pan agonists also activate lipogenic genes, resulting in elevated plasma and hepatic lipids. We report the pharmacology of BMS-779788 [2-(2-(1-(2-chlorophenyl)-1-methylethyl)-1-(3′-(methylsulfonyl)-4-biphenylyl)-1H-imidazol-4-yl)-2-propanol], a potent partial LXR agonist with LXRβ selectivity, which has an improved therapeutic window in the cynomolgus monkey compared with a full pan agonist. BMS-779788 induced LXR target genes in blood in vivo with an EC50 = 610 nM, a value similar to its in vitro blood gene induction potency. BMS-779788 was 29- and 12-fold less potent than the full agonist T0901317 in elevating plasma triglyceride and LDL cholesterol, respectively, with similar results for plasma cholesteryl ester transfer protein and apolipoprotein B. However, ABCA1 and ABCG1 mRNA inductions in blood, which are critical for RCT, were comparable. Increased liver triglyceride was observed after 7-day treatment with BMS-779788 at the highest dose tested and was nearly identical to the dose response for plasma triglyceride, consistent with the central role of liver LXR in these lipogenic effects. Dose-dependent increases in biliary cholesterol and decreases in phospholipid and bile acid occurred in BMS-779788–treated animals, similar to LXR agonist effects reported in mouse. In summary, BMS-779788, a partial LXRβ selective agonist, has decreased lipogenic potential compared with a full pan agonist in cynomolgus monkeys, with similar potency in the induction of genes known to stimulate RCT. This provides support in nonhuman primates for improving LXR agonist therapeutic windows by limiting LXRα activity.
- 8 October 2009
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 23 (21) , 3457-3464
Increasing high‐throughput Discovery bioanalysis using automated selected reaction monitoring compound optimization, ultra‐high‐pressure liquid chromatography, and single‐step sample preparation workflows
QuickQuan is an integrated software package for Thermo Scientific triple quadrupole mass spectrometers that allows users to automate routine operations ranging from method development to data processing. QuickQuan automated optimization of compound‐selected reaction monitoring (SRM) transitions by evaluating both positive and negative polarities during an infusion. Whichever mode produces the most intense Q1 scan is then carried to product ion spectra. QuickQuan then writes these SRM methods to a shared network database. The total volume of compound needed is 100 µL infused over approximately 1.6 min. The auto‐optimization is carried out in 96‐well plates and does not require an operator present. The SRM database was shared between two identical TSQ Quantum mass spectrometers. For data acquisition, QuickQuan automatically created a sequence file complete with a data processing method pre‐populated with compound IDs and corresponding SRM transitions. To increase throughput we coupled each Finnigan Quantum with ultra‐high‐pressure liquid chromatography (uHPLC) accomplished using 4× Ultra Flux quaternary pumps that were designed to handle pressures up to 15 000 psi. The total run time for all analyses was 1.2 min using BEH 1.7 µm particle C18 columns. Further time reductions were realized with sample preparation accomplished using Strata Impact protein precipitation plates which provided an in‐well protein crash and 0.20 micron filtering in a one‐step process. Pharmacokinetic data turnaround time was significantly improved by combining these three techniques of automated method development with the speed efficiency of uHPLC and a single step in well sample preparation. Copyright © 2009 John Wiley & Sons, Ltd.
- 8 October 2009
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 23 (21) , 3457-3464
Increasing high‐throughput Discovery bioanalysis using automated selected reaction monitoring compound optimization, ultra‐high‐pressure liquid chromatography, and single‐step sample preparation workflows
QuickQuan is an integrated software package for Thermo Scientific triple quadrupole mass spectrometers that allows users to automate routine operations ranging from method development to data processing. QuickQuan automated optimization of compound‐selected reaction monitoring (SRM) transitions by evaluating both positive and negative polarities during an infusion. Whichever mode produces the most intense Q1 scan is then carried to product ion spectra. QuickQuan then writes these SRM methods to a shared network database. The total volume of compound needed is 100 µL infused over approximately 1.6 min. The auto‐optimization is carried out in 96‐well plates and does not require an operator present. The SRM database was shared between two identical TSQ Quantum mass spectrometers. For data acquisition, QuickQuan automatically created a sequence file complete with a data processing method pre‐populated with compound IDs and corresponding SRM transitions. To increase throughput we coupled each Finnigan Quantum with ultra‐high‐pressure liquid chromatography (uHPLC) accomplished using 4× Ultra Flux quaternary pumps that were designed to handle pressures up to 15 000 psi. The total run time for all analyses was 1.2 min using BEH 1.7 µm particle C18 columns. Further time reductions were realized with sample preparation accomplished using Strata Impact protein precipitation plates which provided an in‐well protein crash and 0.20 micron filtering in a one‐step process. Pharmacokinetic data turnaround time was significantly improved by combining these three techniques of automated method development with the speed efficiency of uHPLC and a single step in well sample preparation. Copyright © 2009 John Wiley & Sons, Ltd.
- 1 April 2008
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 22 (9) , 1359-1366
Application of ion trap technology to liquid chromatography/mass spectrometry quantitation of large peptides
Triple quadrupole mass spectrometers are generally considered the instrument of choice for quantitative analysis. However, for the analysis of large peptides we have encountered some cases where, as the data presented here would indicate, ion trap mass spectrometers may be a good alternative. In general, specificity and sensitivity in bioanalytical liquid chromatography/mass spectrometry (LC/MS) assays are achieved via tandem MS (MS/MS) utilizing collision‐induced dissociation (CID) while monitoring unique precursor to product ion transitions (i.e. selected reaction monitoring, SRM). Due to the difference in CID processes, triple quadrupoles and ion traps often generate significantly different fragmentation spectra of product ion species and intensities. The large peptidic analytes investigated here generated fewer fragments with higher relative abundance on the ion trap as compared to those generated on the triple quadrupole, resulting in lower limits of detection on the ion trap. Copyright © 2008 John Wiley & Sons, Ltd.
- 1 April 2008
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 22 (9) , 1359-1366
Application of ion trap technology to liquid chromatography/mass spectrometry quantitation of large peptides
Triple quadrupole mass spectrometers are generally considered the instrument of choice for quantitative analysis. However, for the analysis of large peptides we have encountered some cases where, as the data presented here would indicate, ion trap mass spectrometers may be a good alternative. In general, specificity and sensitivity in bioanalytical liquid chromatography/mass spectrometry (LC/MS) assays are achieved via tandem MS (MS/MS) utilizing collision‐induced dissociation (CID) while monitoring unique precursor to product ion transitions (i.e. selected reaction monitoring, SRM). Due to the difference in CID processes, triple quadrupoles and ion traps often generate significantly different fragmentation spectra of product ion species and intensities. The large peptidic analytes investigated here generated fewer fragments with higher relative abundance on the ion trap as compared to those generated on the triple quadrupole, resulting in lower limits of detection on the ion trap. Copyright © 2008 John Wiley & Sons, Ltd.
- 1 July 2007
- Published by Elsevier in Journal of Chromatography B
- Vol. 854 (1-2) , 260-267
Development of a quantitative LC–MS/MS analytical method coupled with turbulent flow chromatography for digoxin for the in vitro P-gp inhibition assay
- 1 July 2007
- Published by Elsevier in Journal of Chromatography B
- Vol. 854 (1-2) , 260-267
Development of a quantitative LC–MS/MS analytical method coupled with turbulent flow chromatography for digoxin for the in vitro P-gp inhibition assay
- 18 January 2006
- Published by Elsevier in Journal of Chromatography B
- Vol. 830 (2) , 270-277
Development of an on-line extraction turbulent flow chromatography tandem mass spectrometry method for cassette analysis of Caco-2 cell based bi-directional assay samples
- 18 January 2006
- Published by Elsevier in Journal of Chromatography B
- Vol. 830 (2) , 270-277
Development of an on-line extraction turbulent flow chromatography tandem mass spectrometry method for cassette analysis of Caco-2 cell based bi-directional assay samples