YQYonghui Qiao

Yonghui Qiao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yonghui Qiao has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Influence of nozzle diameter on the shock cell structure of Flash-Boiling liquid ammonia jets

    by Chao Liu, Shizhao Zhang, Zhigang Xu, Yonghui Qiao, Zhiwu Wang, Hengjie Guo

  • Open Access

    Thermal–hydraulic optimization of airfoil fins in an air–molten salt printed circuit heat exchangers for Carnot battery thermal energy storage

    by Honggang Wang, Han Yang, Xianglong Zhao, Zhide Wang, Meiyan Zhang, Yonghui Qiao

    Printed circuit heat exchangers show considerable potential for high-temperature air–molten salt heat transfer and thermal storage in Carnot batteries, but weak air-side heat-transfer capability and the flow resistance induced by enhancement structures limit their thermal–hydraulic performance. To address this issue, a three-dimensional conjugate heat-transfer model of a representative periodic air–molten salt print circuit heat exchanger segment was developed, with the local boundary conditions mapped from a nominal 89.3 MW Carnot-battery heat-transfer duty. The shear stress transport k–ω turbulence model was used to examine the effects of air-side fin geometry. Triangular, diamond, rectangular, and NACA0025 airfoil fins were first compared under identical chord length and cross-sectional area. The diamond fin produced the highest Nusselt number (Nu) but caused a large flow-resistance penalty, whereas the NACA0025 airfoil fin achieved the lowest Fanning friction factor and the highest heat-transfer-to-flow-power ratio, making it a suitable baseline for low-pressure-drop air-side enhancement. The effects of maximum fin thickness, maximum-thickness location, and leading-edge radius were then analyzed. Based on 100 computational fluid mechanics samples, a back-propagation neural network-assisted two-objective optimization framework was developed to maximize Nu and minimize f under baseline non-deterioration constraints. Entropy-weight TOPSIS (technique for order of preference by similarity to ideal solution) identified Wf=0.934 mm, Df=0.804 mm, and Rf=0.260 mm as the recommended design. Computational fluid mechanics verification yielded Nu=61.07, f=0.00830, and ηQ/P=122.92. Compared with the baseline NACA0025 fin, the recommended structure increased Nu by 1.03%, reduced f by 3.48%, and increased ηQ/P by 4.48%. A controlled local air-side sensitivity analysis showed that the recommended fin retained its relative thermal–hydraulic advantages over the baseline structure under the investigated air-side inlet-temperature and mass-flow-rate ranges, while the molten-salt-side boundary conditions were fixed. This study provides local fin-level design guidance for low-pressure-drop air-side enhancement of air–molten salt printed circuit heat exchangers under operating conditions relevant to Carnot-battery thermal energy storage.

  • Open Access

    Limb graft occlusion after endovascular abdominal aortic aneurysm repair: Hemodynamic and morphological insights

    by Jingyang Luan, Le Mao, Yan Wang, Jizhou Yang, Yonghui Qiao, Kun Luo, Jianren Fan, Ting Zhu

    Endovascular aneurysm repair (EVAR) has become a cornerstone of modern vascular practice, offering a minimally invasive alternative to conventional open surgery for the treatment of abdominal aortic pathologies. Its efficacy can be undermined by limb invasive alternatives. However, its graft occlusion (LGO) is a complication characterized by thrombotic obstruction. To investigate the hemodynamic and morphological characteristics of LGO-affected limbs, we performed morphological measurements and hemodynamic simulations on 22 patient-specific geometries collected from a tertiary center. Logistic regression models were applied to identify prognostic factors. In addition, using computer-aided design technology, we modeled two different intervention strategies to explore the impact of virtual surgery on the progression of thrombosis in occluded limbs. Our analysis revealed that the LGO group exhibited significantly higher values for relative residence time, oscillatory shear index (OSI), and endothelial cell activation potential (ECAP), alongside significantly lower time-averaged wall shear stress (p < 0.001). Morphological assessments showed significantly increased limb cannulation stenosis rates (p < 0.001) in the LGO group. Multivariate regression analysis identified OSI and limb cannulation stenosis rate as independent predictors of LGO. Building on this, a predictive nomogram incorporating these two parameters was developed. These findings highlight the importance of combining hemodynamic and morphological assessments to predict and prevent LGO, and the nomogram we developed can effectively support this process. In addition, combining virtual surgery with hemodynamic simulation can be a novel paradigm in the perioperative management of EVAR patients.

  • Permeation dynamics of organic moiety-tuned organosilica nanoparticles across porcine corneal barriers: experimental and mass transfer analysis for glaucoma drug delivery

    by Yifan Sun, Hengjun Mei, Hongguang Cui, Maomao Song, Yonghui Qiao, Jian Chen, Yuan Lei

    Elevated intraocular pressure is a key pathogenic factor in glaucoma, often leading to irreversible vision loss. In previous studies, we developed a novel hollow mesoporous organosilica nanocarrier functionalized with manganese(III) tetrakis(1-methyl-4-pyridyl)porphyrin (HMMN), demonstrating superior efficacy in treating primary open-angle glaucoma. This study presents a comparative analysis of the transcorneal permeability of HMMNs modified with thioether, biphenyl, and thioether/phenylene moieties in the porcine eye. Transcorneal permeability was evaluated using fluorescence intensity measurements in the porcine aqueous humor, followed by the calculation of diffusion and apparent permeability coefficients (Papp). Results reveal that thioether-modified HMMN exhibits significantly enhanced corneal permeability compared to biphenyl and thioether/phenylene-modified variants, with a diffusion coefficient of 4.88 × 10−6 cm2 s−1 and a Papp of 1.30 × 10–5 cm s−1 in the porcine eye. These findings provide valuable insights into the permeability properties of hollow mesoporous organosilica nanocarriers, positioning them for broader applications in the treatment of various ocular diseases and potentially beyond. Furthermore, this work serves as a valuable reference for future studies exploring the potential of hybridized hollow mesoporous organosilica nanoparticles functionalized with diverse organic moieties for enhanced therapeutic outcomes.


  • Effects of non-Newtonian models on viscosity of unsteady aortic blood flow

    by Yonghui Qiao, Yifan Sun, Hengjie Guo, Zhouzhou Pan, Shuai Wang, Jianren Fan, Kun Luo

    Computational hemodynamics plays a crucial role in reproducing the details of aortic blood flow. However, the application of the non-Newtonian viscosity model is still controversial. The objective of this study is to demonstrate the effects of different non-Newtonian models on the viscosity of blood flow in healthy aorta. First, we reconstructed the three-dimensional geometric models of two healthy aortas based on computed tomography angiography images. The blood flow waveform with parabolic distribution and the three-element Windkessel model were adopted as boundary conditions. Then, the interaction between the blood flow and hyperelastic aortic vessel wall was considered by the two-way fluid–structure interaction method. Finally, we chose four commonly used non-Newtonian viscosity models: the Quemada model, Casson model, Carreau, and Carreau–Yasuda models. Results show that the instantaneous low shear strain rate (SSR < 100 s−1) cannot be neglected considering its relatively high proportion in the aortic wall (50%) and cardiac cycle (33%). We find that the Quemada model can predict the shear-thinning properties of aortic blood flow, especially the relatively low viscosity distribution. Besides, the high-viscosity iso-surface is observed in the descending aorta throughout the cardiac cycle. The phenomena further underline that the Newtonian assumption is not suitable for predicting the viscosity distribution of aortic blood flow. In conclusion, the non-Newtonian viscosity model is suggested to be adopted in aortic computational hemodynamics, and the performance of the Quemada model is satisfactory.


  • Biomechanical mechanism of distal stent-graft-induced new entry deterioration after thoracic endovascular aortic repair

    by Yonghui Qiao, Jingyang Luan, Le Mao, Jianren Fan, Ting Zhu, Kun Luo

    Stent-grafts are bringing new life to aortic dissection patients through thoracic endovascular aortic repair (TEVAR). However, various postoperative complications are threatening the recovery of patients and even require clinical reintervention. The objective of the present study is to reveal the biomechanical mechanism of distal stent-graft-induced new entry (dSINE) deterioration after TEVAR. Six patients treated by TEVAR were collected from the clinical hospital, and dSINE was observed in the follow-up of all patients, which are evenly divided into two groups. The dSINE in the control group was stable while the patients in the experimental group continued to deteriorate and experienced reintervention. Computational fluid-structure interaction hemodynamics were performed in the above patients based on clinical images of early dSINE. The results show that time-averaged wall shear stress or oscillatory shear index alone fails to accurately forecast the deterioration of dSINE. While relative residence time and endothelial cell activation potential demonstrate stronger predictive power and the former seems to be better. Additionally, the region exposed to high von Mises stress and significant wall deformation is also associated with further dSINE deterioration. In conclusion, this study highlights that the postoperative biomechanical environment can predict the further development of dSINE, which is conducive to assisting physicians in improving the risk stratification of dSINE and customizing a follow-up plan.