RMRohit Mehta

Rohit Mehta

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Rohit Mehta has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Accuracy of Portable Monitoring in Diagnosing Significant Sleep Disordered Breathing in Hospitalized Patients

    by Swamy Nagubadi, Rohit Mehta, Mamoun Abdoh, Mohammedumer Nagori, Stephen Littleton, Renaud Gueret, Aiman Tulaimat

    Polysomnograms are not always feasible when sleep disordered breathing (SDB) is suspected in hospitalized patients. Portable monitoring is a practical alternative; however, it has not been recommended in patients with comorbidities. We evaluated the accuracy of portable monitoring in hospitalized patients suspected of having SDB. Prospective observational study. Large, public, urban, teaching hospital in the United States. Hospitalized patients suspected of having SDB. Patients underwent portable monitoring combined with actigraphy during the hospitalization and then polysomnography after discharge. We determined the accuracy of portable monitoring in predicting moderate to severe SDB and the agreement between the apnea hypopnea index measured by portable monitor (AHIPM) and by polysomnogram (AHIPSG). Seventy-one symptomatic patients completed both tests. The median time between the two tests was 97 days (IQR 25–75: 24–109). Forty-five percent were hospitalized for cardiovascular disease. Mean age was 52±10 years, 41% were women, and the majority had symptoms of SDB. Based on AHIPSG, SDB was moderate in 9 patients and severe in 39. The area under the receiver operator characteristics curve for AHIPM was 0.8, and increased to 0.86 in patients without central sleep apnea; it was 0.88 in the 31 patients with hypercapnia. For predicting moderate to severe SDB, an AHIPM of 14 had a sensitivity of 90%, and an AHIPM of 36 had a specificity of 87%. The mean±SD difference between AHIPM and AHIPSG was 2±29 event/hr. In hospitalized, symptomatic patients, portable monitoring is reasonably accurate in detecting moderate to severe SDB.


  • Survival Implications: Hypertrophic Cardiomyopathy in Noonan Syndrome

    by Edward J. Hickey, Rohit Mehta, Maryam Elmi, Kentaro Asoh, Brian W. McCrindle, William G. Williams, Cedric Manlhiot, Lee Benson

    To understand relationships and survival implications between structural heart disease and hypertrophic cardiomyopathy in Noonan syndrome (Noonan syndrome-HCM), we reviewed the clinical course of 138 children with Noonan syndrome diagnosed with cardiovascular abnormalities and compared survival with the 30 children with Noonan syndrome-HCM with 120 contemporaneous children with nonsyndromic HCM. Study cohorts represent consecutive cases diagnosed at our institution 1966 through 2006. Outcomes were modeled using multiphase parametric techniques followed by multivariable regression with bagging. Cardiac abnormalities in Noonan syndrome: Cardiac abnormalities in the 138 Noonan syndrome children included pulmonary valve dysplasia (52%), hypertrophic cardiomyopathy (22%), atrial septal defect (20%), ventricular septal defect (10%), mitral valve dysplasia (6%), coarctation (3%), and Fallot's tetralogy (2%). Need for surgery was high but not different from children with structural defects coexisting with HCM. Overall, late survival in children with Noonan syndrome and cardiac defects was good (91 ± 3% at 15 years), although significantly worse for those with Noonan syndrome-HCM (P < .01). Noonan syndrome-HCM vs. nonsyndromic HCM: In the 30 children with Noonan syndrome-HCM, structural cardiac malformations coexisted in 18 (57%). The incidence of structural cardiac malformations in nonsyndromic HCM was instead 3/120 (2.5%, P < .001). Risk-adjusted late survival was significantly worse for Noonan syndrome-HCM than for nonsyndromic HCM (P= .02). Noonan syndrome-HCM frequently coexists with structural cardiac malformations, whereas nonsyndromic HCM does not; their natural histories may therefore be different. Late survival is significantly worse for Noonan syndrome-HCM than nonsyndromic HCM.


  • Complications of pediatric cardiac catheterization: A review in the current era

    by Rohit Mehta, Kyong‐Jin Lee, Rajiv Chaturvedi, Lee Benson

    Objective: To determine types of complications and risks associated with pedatric cardiac catheterization in the current era. Background: Pedatric cardiac catheterization is an important diagnostic and therapeutic tool. Although in the last decade, there have been significant improvements in technology and equipment, the risk for complications remains, adversely effecting outcomes. Design: The clinical records of 11,073 children undergoing cardiac catheterizations between January 1994 and March 2006 were reviewed to identify procedures associated with complications within the first 24 h after catheterization. All children's electronic and paper chart records were reviewed to obtain demographic, procedural, and treatment data. Results: A total of 858 (7.3%) complications (classified as major or minor) occurred in 816 studies (510 males, 63%), in children ranging in age from 8 h to 20 years (median 4.13 years). There were 195 major (22%) and 663 (78%) minor complications. Vascular complications represented the majority (n = 278; 32.4%) and were major in 53 instances (P < 0.0001). Twenty‐five children died within 24 h (0.23% of total case numbers). Independent risk factors for a complication included young patient age (<6 months), male gender, inpatient status, and year of catheterization. Conclusions: Complications continue to be associated with pedatric cardiac catheterization, although overall incidence appears to be decreasing. Patient age, gender, and inpatient status continue to be risk factors for morbidity and mortality. Efforts at improving equipment for flexibility and size, and developing strategies for the use of alternative methods for catheter access should be encouraged.


  • Feasibility and clinical impact of transcatheter closure of interatrial communications after a fenestrated Fontan procedure: Medium‐term outcomes

    by Jaana Pihkala, Satoshi Yazaki, Rohit Mehta, Kyong‐Jin Lee, Rajiv Chaturvedi, Brian W. McCrindle, Glen Van Arsdell, Lee N. Benson

    Objective: This study was to review an institutional experience with transcatheter closure of Fontan fenestrations and its impact on clinical care. Background: An interatrial fenestration improves postoperative outcomes in high-risk children undergoing a Fontan repair. While technical feasibility has been well defined, the clinical impact of subsequent closure is not well defined. Methods: Transcatheter closure of a surgically created or additional interatrial communication was attempted in 152 children at a median interval of 13.8 months after surgery. The clinical records were reviewed for demographic and anatomical characteristics, previous surgeries; catheterization data, and status at latest follow-up. Results: Mean oxygen saturation and right atrial pressure increased acutely from 87% ± 5% to 96% ± 3% (P < 0.001) and 12 ± 2 mm Hg to 13 ± 3 mm Hg (P < 0.001), respectively. Higher systemic venous atrial pressures after occlusion correlated with higher pulmonary artery pressures (P = 0.05) before the Fontan procedure and with higher right (P < 0.001) and left atrial (P = 0.001) and ventricular end-diastolic pressures (P < 0.001) immediately before occlusion. Complications included device malposition in 2 children, 1 child each had an air embolism and post-procedural bleeding, and each self-limiting and 1 child had acute ST elevation in inferior ECG leads because of occlusion of the acute marginal branch which was treated with angioplasty and placement of a stent. At follow-up (median 4.5 years), the mean oxygen saturation was 95% ± 3%. Residual interatrial leaks were noted echocardiographically in 9%. Two children developed protein-losing enteropathy after fenestration closure. No deaths or strokes were observed in follow-up. Conclusions: Transcatheter occlusion of Fontan fenestrations is safe with acute and persistent improvements in oxygen saturations.