Mustafa Uçan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mustafa Uçan has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Ibrahim Narin
Faculty of Pharmacy, Erciyes University, 38039 Kayseri, Turkey
6 shared publications Abdullah Taner Bişgin
Department of Chemistry, Faculty of Arts and Sciences, Niğde University, 51100 Nigde, Turkey
4 shared publications- Abdullah Taner Bişgin
Niğde Ömer Halisdemir University, Faculty of Science, Department of Chemistry, 51240 Niğde, Türkiye
4 shared publications - Ahmet Ayar
Department of Chemistry, Faculty of Sciences and Arts, University of Niğde, Niğde, Turkey
3 shared publications - Yavuz Sürme
Niğde Ömer Halisdemir Üniversitesi
3 shared publications A. Coşkun
Selcuk University
2 shared publications
Latest Publications
- Open Access
- 16 April 2024
- Published by Omer Halisdemir Universitesi in Ömer Halisdemir Üniversitesi Mühendislik Bilimleri Dergisi
Rapid preconcentration and determination of Co (II) ions in aqueous medium using ultrasound assisted cloud point extraction method
A flame atomic absorption spectrophotometric technique was studied for the preconcentration and determination of of Co2+ ions in trace amounts after ultrasound enhanced enrichment of its 1-(2-pyridylazo)-2-naphthol (PAN) complexes by cloud point extraction. The Co2+ ions were firstly complexed with PAN molecules at pH 4 and the complex transferred to a surfactant (Tergitol NP-7) rich phase with a very small volume under ultrasound waves. The surfactant rich phase was separated and dissolved by 1 mL, 1.0 M HNO3 in ethanol prior to determination of Co2+ concentration by flame atomic absorption spectrophotometry. The optimization steps of ultrasound interaction time, solution pH and surfactant volumes were achieved by response surface methodology (RSM) which is a combination of statistical approaches. Sample volume, PAN concentration and and possible interfering ions were optimized conventionally. The Co2+ ions were extracted only in 150 s at pH 4 quantitatively under optimum conditions (˃95%). The accuracy and validity of developed UA-CPE was granted by employing a certified reference material wastewater UME CRM 1204. The technique was applied to wastewater and natural water with satisfactory results.
- 16 April 2024
- Published by Omer Halisdemir Universitesi in Ömer Halisdemir Üniversitesi Mühendislik Bilimleri Dergisi
Open AccessRapid preconcentration and determination of Co (II) ions in aqueous medium using ultrasound assisted cloud point extraction method
A flame atomic absorption spectrophotometric technique was studied for the preconcentration and determination of of Co2+ ions in trace amounts after ultrasound enhanced enrichment of its 1-(2-pyridylazo)-2-naphthol (PAN) complexes by cloud point extraction. The Co2+ ions were firstly complexed with PAN molecules at pH 4 and the complex transferred to a surfactant (Tergitol NP-7) rich phase with a very small volume under ultrasound waves. The surfactant rich phase was separated and dissolved by 1 mL, 1.0 M HNO3 in ethanol prior to determination of Co2+ concentration by flame atomic absorption spectrophotometry. The optimization steps of ultrasound interaction time, solution pH and surfactant volumes were achieved by response surface methodology (RSM) which is a combination of statistical approaches. Sample volume, PAN concentration and and possible interfering ions were optimized conventionally. The Co2+ ions were extracted only in 150 s at pH 4 quantitatively under optimum conditions (˃95%). The accuracy and validity of developed UA-CPE was granted by employing a certified reference material wastewater UME CRM 1204. The technique was applied to wastewater and natural water with satisfactory results.
- 30 June 2021
- Published by Cumhuriyet University in Cumhuriyet Science Journal
- Vol. 42 (2) , 285-291
Determination and evaluation of Cu, Mn, Zn, Cd, Pb and Ni contents in wild-grown edible mushroom species from Cappadocia, Turkey
The aim of this study was to determine the Cu, Mn, Zn, Cd, Pb and Ni concentrations in sixteen different wild-grown edible mushroom species grown in Niğde and Nevşehir. In the sample preparation step, the samples were dried, ground and sieved by 200 meshed sieve, consecutively. The extractions of metals were conducted by acid mineralization using concentrated nitric acid and hydrogen peroxide in microwave digestion unit. The determinations of metals were performed by flame atomic absorption spectrometry. Among the mushroom samples that were analyzed, Cu, Mn, Zn, Cd, Pb, and Ni concentrations were determined in the range of 6.7-1353, 4.7-109, 44.8-406, 0.14-6.4, 4.28-25.6 and 1.7-11.0 mg/kg, respectively. The accuracy and precision of the proposed method for metal determinations were validated by using the NIST SRM 1573a Tomato Leaves certified standard material. The obtained results were evaluated in terms of human health and compared with each other and previously reported values in the literature. In addition, the habitats of the mushroom samples were identified.
- 30 June 2021
- Published by Cumhuriyet University in Cumhuriyet Science Journal
- Vol. 42 (2) , 285-291
Determination and evaluation of Cu, Mn, Zn, Cd, Pb and Ni contents in wild-grown edible mushroom species from Cappadocia, Turkey
The aim of this study was to determine the Cu, Mn, Zn, Cd, Pb and Ni concentrations in sixteen different wild-grown edible mushroom species grown in Niğde and Nevşehir. In the sample preparation step, the samples were dried, ground and sieved by 200 meshed sieve, consecutively. The extractions of metals were conducted by acid mineralization using concentrated nitric acid and hydrogen peroxide in microwave digestion unit. The determinations of metals were performed by flame atomic absorption spectrometry. Among the mushroom samples that were analyzed, Cu, Mn, Zn, Cd, Pb, and Ni concentrations were determined in the range of 6.7-1353, 4.7-109, 44.8-406, 0.14-6.4, 4.28-25.6 and 1.7-11.0 mg/kg, respectively. The accuracy and precision of the proposed method for metal determinations were validated by using the NIST SRM 1573a Tomato Leaves certified standard material. The obtained results were evaluated in terms of human health and compared with each other and previously reported values in the literature. In addition, the habitats of the mushroom samples were identified.
- 3 September 2020
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 75 (9) , 1131-1136
Micelle Mediated Extraction and Flame Atomic Absorption Spectrometric Determination of Trace Amounts of Copper in Different Mushroom Species
A micelle mediated separation and preconcentration method for flame atomic absorption spectrophotometric (FAAS) determination of Cu was developed. The method is based on complex formation between Cu and 1-(2-pyridylazo)-2-naphthol and cloud point extraction with Tergitol NP-7 surfactant prior to FAAS determination. The parameters affecting quantitative extraction of copper, including pH, surfactant and ligand concentrations, incubation time and temperature, were examined and optimized. Under optimum conditions, interference effects of other ions were studied, and tolerance ratios of interference ions were given. Under the optimal conditions, detection and quantitation limits were found as 3 and 8 μg/L, respectively. Linear dynamic range for Cu2+ was determined to be 0.13–1.5 μg/mL. Relative standard deviations were below 6% throughout the experiments. Enhancement factor was determined as 25. Applicability of the method was proved by analysis of standard reference materials. The developed method was applied to determine trace copper contents in different mushroom species.
- 3 September 2020
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 75 (9) , 1131-1136
Micelle Mediated Extraction and Flame Atomic Absorption Spectrometric Determination of Trace Amounts of Copper in Different Mushroom Species
A micelle mediated separation and preconcentration method for flame atomic absorption spectrophotometric (FAAS) determination of Cu was developed. The method is based on complex formation between Cu and 1-(2-pyridylazo)-2-naphthol and cloud point extraction with Tergitol NP-7 surfactant prior to FAAS determination. The parameters affecting quantitative extraction of copper, including pH, surfactant and ligand concentrations, incubation time and temperature, were examined and optimized. Under optimum conditions, interference effects of other ions were studied, and tolerance ratios of interference ions were given. Under the optimal conditions, detection and quantitation limits were found as 3 and 8 μg/L, respectively. Linear dynamic range for Cu2+ was determined to be 0.13–1.5 μg/mL. Relative standard deviations were below 6% throughout the experiments. Enhancement factor was determined as 25. Applicability of the method was proved by analysis of standard reference materials. The developed method was applied to determine trace copper contents in different mushroom species.
- 2 May 2018
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 73 (5) , 452-458
Separation, Preconcentration and Spectrophotometric Determination of Rhodamine B in Industrial, Cosmetic and Water Samples by Cloud Point and Solid Phase Extraction
The aim of this study is extraction, preconcentration and spectrophotometric determination of Rhodamine B (RB) in aqueous media by developing solid phase extraction (SPE) and cloud point extraction...
- 2 May 2018
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 73 (5) , 452-458
Separation, Preconcentration and Spectrophotometric Determination of Rhodamine B in Industrial, Cosmetic and Water Samples by Cloud Point and Solid Phase Extraction
The aim of this study is extraction, preconcentration and spectrophotometric determination of Rhodamine B (RB) in aqueous media by developing solid phase extraction (SPE) and cloud point extraction...
- 8 August 2016
- Published by Oxford University Press (OUP) in International Journal of Food Science and Technology
- Vol. 51 (11) , 2367-2375
Solid‐phase extraction and spectrophotometric determination of Allura Red (E129) in foodstuff, soft drink, syrup and energy drink samples: a comparison study
Summary: Amberlite XAD‐7 and XAD‐8 resins were used as adsorbents for preconcentration and determination of Allura Red (AR) food dye in aqueous medium. The effects of pH, sample volume, sample and eluent flow rates on the extraction of AR were optimised. The determination of dye was performed at 506.0 nm using spectrophotometry. Interference effects of matrix ions and some dyes were also investigated under optimised conditions. The methods permitted low detection limits which were 1.2 and 0.6 μg L−1 for XAD‐7 and XAD‐8, respectively. Adsorption behaviours were investigated by adsorption isotherms and zero charge pH experiments. Validations of the method were performed by determination of AR contents in some foodstuffs. AR contents of liquid samples were found between 58 and 440 μg mL−1. AR concentrations of solid samples were between 416 and 432 μg g−1. The XAD‐7 and XAD‐8 resins presented a fast and reliable potential to determine AR dye in real samples.
- 8 August 2016
- Published by Oxford University Press (OUP) in International Journal of Food Science and Technology
- Vol. 51 (11) , 2367-2375
Solid‐phase extraction and spectrophotometric determination of Allura Red (E129) in foodstuff, soft drink, syrup and energy drink samples: a comparison study
Summary: Amberlite XAD‐7 and XAD‐8 resins were used as adsorbents for preconcentration and determination of Allura Red (AR) food dye in aqueous medium. The effects of pH, sample volume, sample and eluent flow rates on the extraction of AR were optimised. The determination of dye was performed at 506.0 nm using spectrophotometry. Interference effects of matrix ions and some dyes were also investigated under optimised conditions. The methods permitted low detection limits which were 1.2 and 0.6 μg L−1 for XAD‐7 and XAD‐8, respectively. Adsorption behaviours were investigated by adsorption isotherms and zero charge pH experiments. Validations of the method were performed by determination of AR contents in some foodstuffs. AR contents of liquid samples were found between 58 and 440 μg mL−1. AR concentrations of solid samples were between 416 and 432 μg g−1. The XAD‐7 and XAD‐8 resins presented a fast and reliable potential to determine AR dye in real samples.
- 1 August 2016
- Published by Pleiades Publishing Ltd in Russian Journal of General Chemistry
- Vol. 86 (8) , 1917-1921
Synthesis and characterization of some metal complexes of isonitroso-2-acetylnaphthalene derivative
- 1 August 2016
- Published by Pleiades Publishing Ltd in Russian Journal of General Chemistry
- Vol. 86 (8) , 1917-1921
Synthesis and characterization of some metal complexes of isonitroso-2-acetylnaphthalene derivative
- Open Access
- 1 July 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (32) , 14965-14972
Comparison of preconcentration and determination methods of a textile dye by spectrophotometry: cloud point extraction and solid-phase extraction
This study deals with the preconcentration, determination, and removal of Lanaset Blue 2R textile dye from aqueous medium by two different methods. For this purpose, cloud point extraction (CPE) and solid phase extraction (SPE) methods were optimized. Amberlite XAD-1180 resin was used as adsorbent for SPE while Tergitol NP-7 non-ionic surfactant was used as surfactant rich phase for CPE. The common optimization steps were determined as initial solution pH, linear dynamic range, sample volume, equilibrium time and limits of detections were characterized for both SPE and CPE techniques while specific optimization steps such as temperature and surfactant concentration were also determined for CPE. The results showed that the CPE and SPE of dye were quantitative at pH 6. Detection limits were 21-μg L−1 for CPE and 9-μg L−1 for SPE. The enrichment factors were 40 and 10 for SPE and CPE, respectively. The real sample analysis was successfully performed with both techniques. The strengths and weaknesses of the methods were highlighted.
- 1 July 2016
- Published by Elsevier in Desalination and Water Treatment
- Vol. 57 (32) , 14965-14972
Open AccessComparison of preconcentration and determination methods of a textile dye by spectrophotometry: cloud point extraction and solid-phase extraction
This study deals with the preconcentration, determination, and removal of Lanaset Blue 2R textile dye from aqueous medium by two different methods. For this purpose, cloud point extraction (CPE) and solid phase extraction (SPE) methods were optimized. Amberlite XAD-1180 resin was used as adsorbent for SPE while Tergitol NP-7 non-ionic surfactant was used as surfactant rich phase for CPE. The common optimization steps were determined as initial solution pH, linear dynamic range, sample volume, equilibrium time and limits of detections were characterized for both SPE and CPE techniques while specific optimization steps such as temperature and surfactant concentration were also determined for CPE. The results showed that the CPE and SPE of dye were quantitative at pH 6. Detection limits were 21-μg L−1 for CPE and 9-μg L−1 for SPE. The enrichment factors were 40 and 10 for SPE and CPE, respectively. The real sample analysis was successfully performed with both techniques. The strengths and weaknesses of the methods were highlighted.
- 1 July 2015
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 98 (4) , 946-952
Comparison of Column Solid-Phase Extraction Procedures for Spectrophotometric Determination of E129 (Allura Red) in Foodstuff, Pharmaceutical, and Energy Drink Samples
Two novel spectrophotometric determination procedures based on retention of Allura Red onto Amberlite XAD-1180 and XAD-16 resins for its preconcentration, purification, and separation were developed. Analytical parameters of the methods including pH, eluent type, sample volume, and sample and eluent flow rates, were investigated and optimized. Interference effects of some cations, anions, and widely used food dyes were also investigated. Detection limits of the two methods were found to be 1.2 and 1.5 μg/L for XAD-1180 and XAD-16 columns, respectively, under optimum conditions. Linear calibration curve ranges of the methods were 0.4–8.0 and 0.5–6.0 μg/mL of Allura Red for XAD-1180 and XAD-16 resins, respectively. Preconcentration factors were found as 80 for both the XAD-1180 and XAD-16 columns using maximum sample volume and minimum eluent volume. RSDs of the methods were below 6% throughout all experiments. All absorbance measurements were performed at 506 nm. Validations of the methods were performed comparatively with determination of the Allura Red contents of some foodstuff, pharmaceutical, and energy drink samples. Allura Red concentrations in investigated solid and liquid samples ranged from 298 to 501 μg/g and 53.8 to 508 μg/mL, respectively. Satisfactory results were obtained from the real samples analysis. Allura Red contents of samples were determined to be highly similar using the two extraction methods. Comparisons of the methods were performed by analysis of Allura Red contents of the real samples. In addition to analytical parameters, adsorption isotherm studies were performed for the two kinds of Amberlite resins. It was observed that developed methods fit the linear form of the Freundlich adsorption isotherm model. All of the experimental results suggested that the developed SPE procedures are suitable for separation, preconcentration, and determination of Allura Red in solid and liquid matrixes.
- 1 July 2015
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 98 (4) , 946-952
Comparison of Column Solid-Phase Extraction Procedures for Spectrophotometric Determination of E129 (Allura Red) in Foodstuff, Pharmaceutical, and Energy Drink Samples
Two novel spectrophotometric determination procedures based on retention of Allura Red onto Amberlite XAD-1180 and XAD-16 resins for its preconcentration, purification, and separation were developed. Analytical parameters of the methods including pH, eluent type, sample volume, and sample and eluent flow rates, were investigated and optimized. Interference effects of some cations, anions, and widely used food dyes were also investigated. Detection limits of the two methods were found to be 1.2 and 1.5 μg/L for XAD-1180 and XAD-16 columns, respectively, under optimum conditions. Linear calibration curve ranges of the methods were 0.4–8.0 and 0.5–6.0 μg/mL of Allura Red for XAD-1180 and XAD-16 resins, respectively. Preconcentration factors were found as 80 for both the XAD-1180 and XAD-16 columns using maximum sample volume and minimum eluent volume. RSDs of the methods were below 6% throughout all experiments. All absorbance measurements were performed at 506 nm. Validations of the methods were performed comparatively with determination of the Allura Red contents of some foodstuff, pharmaceutical, and energy drink samples. Allura Red concentrations in investigated solid and liquid samples ranged from 298 to 501 μg/g and 53.8 to 508 μg/mL, respectively. Satisfactory results were obtained from the real samples analysis. Allura Red contents of samples were determined to be highly similar using the two extraction methods. Comparisons of the methods were performed by analysis of Allura Red contents of the real samples. In addition to analytical parameters, adsorption isotherm studies were performed for the two kinds of Amberlite resins. It was observed that developed methods fit the linear form of the Freundlich adsorption isotherm model. All of the experimental results suggested that the developed SPE procedures are suitable for separation, preconcentration, and determination of Allura Red in solid and liquid matrixes.
- 10 February 2015
- Published by Oxford University Press (OUP) in International Journal of Food Science and Technology
- Vol. 50 (4) , 919-925
Determination of sunset yellow (E110) in foodstuffs and pharmaceuticals after separation and preconcentration via solid‐phase extraction method
Summary: The two novel preconcentration and separation methods based on adsorption onto Amberlite XAD‐1180 and Amberlite XAD‐16 polymeric resins for spectrophotometric determination of sunset yellow dye were developed. The parameters, affecting the quantitative recovery, including pH, sample and eluent flow rates, eluent type, sample volume, were investigated and optimised. The interference effects of some cations, anions and widely used dye were also studied. At the optimum conditions, detection limits of the methods were found as 2.0 and 1.6 μg L−1 for Amberlite XAD‐1180 and Amberlite XAD‐16 resins, respectively. Linear dynamic ranges of the methods were obtained in the range of 0.2–50.0 and 0.2–20.0 μg mL−1 for Amberlite XAD‐1180 and Amberlite XAD‐16 resins, respectively. The relative standard deviations were below than 7% and 5% for Amberlite XAD‐1180 and Amberlite XAD‐16 resins, respectively. The determination of dye was performed at 483.0 nm using spectrophotometry. Validations of the methods were performed comparatively with determination of the sunset yellow content of some foodstuffs and pharmaceuticals.
- 10 February 2015
- Published by Oxford University Press (OUP) in International Journal of Food Science and Technology
- Vol. 50 (4) , 919-925
Determination of sunset yellow (E110) in foodstuffs and pharmaceuticals after separation and preconcentration via solid‐phase extraction method
Summary: The two novel preconcentration and separation methods based on adsorption onto Amberlite XAD‐1180 and Amberlite XAD‐16 polymeric resins for spectrophotometric determination of sunset yellow dye were developed. The parameters, affecting the quantitative recovery, including pH, sample and eluent flow rates, eluent type, sample volume, were investigated and optimised. The interference effects of some cations, anions and widely used dye were also studied. At the optimum conditions, detection limits of the methods were found as 2.0 and 1.6 μg L−1 for Amberlite XAD‐1180 and Amberlite XAD‐16 resins, respectively. Linear dynamic ranges of the methods were obtained in the range of 0.2–50.0 and 0.2–20.0 μg mL−1 for Amberlite XAD‐1180 and Amberlite XAD‐16 resins, respectively. The relative standard deviations were below than 7% and 5% for Amberlite XAD‐1180 and Amberlite XAD‐16 resins, respectively. The determination of dye was performed at 483.0 nm using spectrophotometry. Validations of the methods were performed comparatively with determination of the sunset yellow content of some foodstuffs and pharmaceuticals.