Gerardo Fernández-Martínez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gerardo Fernández-Martínez has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Darío Prada Rodríguez
Grupo Química Analítica Aplicada (QANAP), Instituto Universitario de Medio Ambiente (IUMA), Centro de Investigaciones Científicas Avanzadas (CICA), Departamento de Química Analítica, Facultade de Ciencias, Universidade da Coruña, Campus de A Coruña, E-15071 A Coruña, Spain
9 shared publications - Purificacion Lopez-Mahia
Grupo Química Analítica Aplicada (QANAP), Instituto Universitario de Medio Ambiente (IUMA), Centro de Investigaciones Científicas Avanzadas (CICA), Departamento de Química Analítica, Facultade de Ciencias, Universidade da Coruña, Campus de A Coruña, E-15071 A Coruña, Spain
8 shared publications - José Manuel López Vilariño
Grupo de Polímeros-Centro de Investigacións Tecnológicas (CIT), Universidade de A Coruña, Campus de Esteiro s/n, 15403 Ferrol, Spain
7 shared publications - Soledad Muniategui-Lorenzo
Group of Applied Analytical Chemistry (QANAP), Instituto Universitario de Medio Ambiente (IUMA), Centro de Innovación Tecnolóxica en Edificación e Enxeñería Civil (CITEEC), Universidade da Coruña, 15071, A Coruña, Spain
6 shared publications - María Victoria González Rodríguez
Grupo de Polímeros-Centro de Investigacións Tecnológicas (CIT), Universidade de A Coruña, Campus de Esteiro s/n, 15403 Ferrol, Spain
4 shared publications E. Fernández-Fernández
University of La Coruña
3 shared publications
Latest Publications
- 1 June 2018
- Published by Elsevier in Journal of Chromatography A
- Vol. 1555, 62-73
Fast and sensitive determination of per- and polyfluoroalkyl substances in seawater
- 1 June 2018
- Published by Elsevier in Journal of Chromatography A
- Vol. 1555, 62-73
Fast and sensitive determination of per- and polyfluoroalkyl substances in seawater
- 7 October 2010
- Published by Wiley in Journal of Separation Science
- Vol. 33 (22) , 3595-3603
Application of liquid chromatography in polymer non‐ionic antistatic additives analysis
This article investigates the applicability of HPLC‐UV, ultra performance LC‐evaporative light‐scattering detection (UPLC‐ELSD), HPLC‐ESI(+)‐MS and HPLC‐hybrid linear ion trap (LTQ) Orbitrap MS for the analysis of different non‐ionic antistatic additives, Span 20, Span 60, Span 65, Span 80, Span 85 (sorbitan fatty acid esters), Atmer 129 (glycerol fatty acid ester) and Atmer 163 (ethoxylated alkylamine). Several alkyl chain length or different degrees of esterification of polyol derivatives can be present in commercial mixtures of these polymer additives. Therefore, their identification and quantification is complicated. Qualitative composition of the studied compounds was analysed by MS. HPLC‐UV, UPLC‐ELSD and HPLC‐LTQ Orbitrap MS methods were applied to the quantitative determination of the different Spans, Atmer 129 and Atmer 163, respectively. Quality parameters of these methods were established and no derivatization was necessary.
- 7 October 2010
- Published by Wiley in Journal of Separation Science
- Vol. 33 (22) , 3595-3603
Application of liquid chromatography in polymer non‐ionic antistatic additives analysis
This article investigates the applicability of HPLC‐UV, ultra performance LC‐evaporative light‐scattering detection (UPLC‐ELSD), HPLC‐ESI(+)‐MS and HPLC‐hybrid linear ion trap (LTQ) Orbitrap MS for the analysis of different non‐ionic antistatic additives, Span 20, Span 60, Span 65, Span 80, Span 85 (sorbitan fatty acid esters), Atmer 129 (glycerol fatty acid ester) and Atmer 163 (ethoxylated alkylamine). Several alkyl chain length or different degrees of esterification of polyol derivatives can be present in commercial mixtures of these polymer additives. Therefore, their identification and quantification is complicated. Qualitative composition of the studied compounds was analysed by MS. HPLC‐UV, UPLC‐ELSD and HPLC‐LTQ Orbitrap MS methods were applied to the quantitative determination of the different Spans, Atmer 129 and Atmer 163, respectively. Quality parameters of these methods were established and no derivatization was necessary.
- 27 July 2010
- Published by Wiley in Journal of Separation Science
- Vol. 33 (17-18) , 2698-2706
Liquid chromatographic methods to analyze hindered amines light stabilizers (HALS) levels to improve safety in polyolefins
A chromatographic method using ultra performance LC with ultraviolet spectrophotometry detection system (UPLC-UV-visible (UV/Vis)) (UPLC, ultra performance LC) was developed to determine Chimassorb 944 and Tinuvin 770, high- and low-molecular mass hindered amine light stabilizers, respectively. The use of a bridge ethylene hybrid-based particles C18 UPLC column, being compatible with a buffered mobile phase adjusted to pH 11.5, was used to achieve a satisfactory elution of possible non-ionizated units of polymeric Chimassorb 944. In addition, a HPLC with positive ion mode ESI and hybrid linear ion trap (LTQ) Fourier transform (FT) Orbitrap MS detection system (HPLC-UV/Vis-ESI-LTQ(FT)Orbitrap) was used for screening and identification purposes. Reliable determinations of monomeric units of Chimassorb 944 and molecule of Tinuvin 770 were achieved by HPLC-ESI(+)-LTQ FT Orbitrap MS method using scan mode. Quality parameters of UPLC-UV/Vis method were evaluated. Obtained LODs and LOQs were 3.41 and 11.4 mg/L for Tinuvin 770 and 0.83 and 2.78 mg/L for Chimassorb 944, respectively. Satisfactory quality parameters of this chromatography method provided the chance to count on a good tool to know the compliance with legal requirements.
- 27 July 2010
- Published by Wiley in Journal of Separation Science
- Vol. 33 (17-18) , 2698-2706
Liquid chromatographic methods to analyze hindered amines light stabilizers (HALS) levels to improve safety in polyolefins
A chromatographic method using ultra performance LC with ultraviolet spectrophotometry detection system (UPLC-UV-visible (UV/Vis)) (UPLC, ultra performance LC) was developed to determine Chimassorb 944 and Tinuvin 770, high- and low-molecular mass hindered amine light stabilizers, respectively. The use of a bridge ethylene hybrid-based particles C18 UPLC column, being compatible with a buffered mobile phase adjusted to pH 11.5, was used to achieve a satisfactory elution of possible non-ionizated units of polymeric Chimassorb 944. In addition, a HPLC with positive ion mode ESI and hybrid linear ion trap (LTQ) Fourier transform (FT) Orbitrap MS detection system (HPLC-UV/Vis-ESI-LTQ(FT)Orbitrap) was used for screening and identification purposes. Reliable determinations of monomeric units of Chimassorb 944 and molecule of Tinuvin 770 were achieved by HPLC-ESI(+)-LTQ FT Orbitrap MS method using scan mode. Quality parameters of UPLC-UV/Vis method were evaluated. Obtained LODs and LOQs were 3.41 and 11.4 mg/L for Tinuvin 770 and 0.83 and 2.78 mg/L for Chimassorb 944, respectively. Satisfactory quality parameters of this chromatography method provided the chance to count on a good tool to know the compliance with legal requirements.
- 1 May 2010
- Published by Elsevier in Analytica Chimica Acta
- Vol. 667 (1-2) , 123-129
Liquid chromatography method to determine polyamines in thermosetting polymers
- 1 May 2010
- Published by Elsevier in Analytica Chimica Acta
- Vol. 667 (1-2) , 123-129
Liquid chromatography method to determine polyamines in thermosetting polymers
- 1 February 2008
- Published by Elsevier in Journal of Chromatography A
- Vol. 1179 (2) , 152-160
High-performance liquid chromatography analysis of ten dyes for control of safety of commercial articles
- 1 February 2008
- Published by Elsevier in Journal of Chromatography A
- Vol. 1179 (2) , 152-160
High-performance liquid chromatography analysis of ten dyes for control of safety of commercial articles
- 1 October 2004
- Published by Elsevier in Chemosphere
- Vol. 57 (1) , 67-71
First assessment of dioxin emissions from coal-fired power stations in Spain
- 1 October 2004
- Published by Elsevier in Chemosphere
- Vol. 57 (1) , 67-71
First assessment of dioxin emissions from coal-fired power stations in Spain
- 1 June 2003
- Published by Taylor & Francis in Environmental Technology
- Vol. 24 (6) , 687-692
Behavior of fluorine and chlorine in Spanish coal fired power plants with pulverized coal boilers and fluidized bed boiler
Behavior and contents of fluorine and chlorine in coal feedstock, combustion wastes (slag and fly ash) and emissions were studied in five conventional coal fired power plants and in a fluidized bed coal power plant. The halide levels found in the used coal were quite low. Mass balances and emission factors were calculated. The volatility of these elements makes the gaseous emission the main target between the residues. The influence of combustion parameters is not clearly established. Several analytical techniques (ion selective electrodes, capillary electrophoresis and ion chromatography) are employed to determinate the halide concentration in the different samples taken in the power plants studied (coal, slag, fly ash and flue gases).
- 1 June 2003
- Published by Taylor & Francis in Environmental Technology
- Vol. 24 (6) , 687-692
Behavior of fluorine and chlorine in Spanish coal fired power plants with pulverized coal boilers and fluidized bed boiler
Behavior and contents of fluorine and chlorine in coal feedstock, combustion wastes (slag and fly ash) and emissions were studied in five conventional coal fired power plants and in a fluidized bed coal power plant. The halide levels found in the used coal were quite low. Mass balances and emission factors were calculated. The volatility of these elements makes the gaseous emission the main target between the residues. The influence of combustion parameters is not clearly established. Several analytical techniques (ion selective electrodes, capillary electrophoresis and ion chromatography) are employed to determinate the halide concentration in the different samples taken in the power plants studied (coal, slag, fly ash and flue gases).
- 1 November 2001
- Published by Elsevier in Atmospheric Environment
- Vol. 35 (33) , 5823-5831
Distribution of volatile organic compounds during the combustion process in coal-fired power stations
- 1 November 2001
- Published by Elsevier in Atmospheric Environment
- Vol. 35 (33) , 5823-5831
Distribution of volatile organic compounds during the combustion process in coal-fired power stations
- 1 July 2001
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 129 (1-4) , 267-288
Measurement of Volatile Organic Compounds in Urban Air of La Coruña, Spain
- 1 July 2001
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 129 (1-4) , 267-288
Measurement of Volatile Organic Compounds in Urban Air of La Coruña, Spain