Tanja R. Zijp
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tanja R. Zijp has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Johannes Touw
Department of Clinical Pharmacy and Pharmacology University Medical Center Groningen, University of Groningen Groningen The Netherlands
8 shared publications - Job Frank Martien van Boven
Department of Clinical Pharmacy & Pharmacology, Groningen Research Institute for Asthma and COPD (GRIAC), University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
5 shared publications - Stephan J. L. Bakker
Division of Nephrology, Department of Internal Medicine, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
3 shared publications - Zamrotul Izzah
Department of Clinical Pharmacy and Pharmacology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
3 shared publications - Christoffer Åberg
Groningen Research Institute of Pharmacy, University of Groningen, A. Deusinglaan 1, 9713 AV Groningen, the Netherlands
2 shared publications - Erwin M. Jongedijk
University of Groningen, University Medical Center Groningen, Department of Clinical Pharmacy and Pharmacology, Groningen, the Netherlands
2 shared publications
Latest Publications
- Open Access
- 3 June 2026
- Published by Taylor & Francis in Expert Opinion on Drug Metabolism & Toxicology
- Vol. 22 (6) , 451-463
Sex differences and impact of age-based menopausal status on tacrolimus pharmacokinetics: results of the TransplantLines Biobank and Cohort study
Growing evidence shows that drugs can have different effects between men and women[1,2]. Sex-based drug differences can originate in differences in pharmacokinetics, including absorption, bioavaila...
- 3 June 2026
- Published by Taylor & Francis in Expert Opinion on Drug Metabolism & Toxicology
- Vol. 22 (6) , 451-463
Open AccessSex differences and impact of age-based menopausal status on tacrolimus pharmacokinetics: results of the TransplantLines Biobank and Cohort study
Growing evidence shows that drugs can have different effects between men and women[1,2]. Sex-based drug differences can originate in differences in pharmacokinetics, including absorption, bioavaila...
- Open Access
- 30 April 2025
- Published by MDPI AG in Pharmaceutics
- Vol. 17 (5) , 590
Plasma Versus Whole Blood Tacrolimus Concentrations and Health-Related Quality of Life in Kidney Transplant Recipients
Background/Objectives: Tacrolimus dosing traditionally relies on therapeutic drug monitoring in whole blood, while assessment in plasma may better reflect its effect and reveal overdosing impacting health-related quality of life (HRQoL). Methods: In this cross-sectional study, 898 kidney transplant recipients (KTRs) who were at least 12 months post-transplantation were included. Plasma and whole blood tacrolimus concentrations were compared using Passing–Bablok regression analyses and Bland–Altman plots. Furthermore, the relationship with daily tacrolimus dose and with HRQoL (mental component summary (MCS), physical component summary (PCS)) was explored using linear regression by comparing standardized coefficients. Lastly, mediation analyses explored the effect of various tacrolimus-related side effects on the association between tacrolimus concentrations and HRQoL. Results: Comparison of the methods revealed a constant bias and a slight proportional bias between whole blood and plasma tacrolimus concentrations. The Bland–Altman plots indicated poor agreement with a statistically significant ratio difference (p < 0.001). Both whole blood and plasma concentrations were significantly associated with daily tacrolimus dose (both p < 0.001). Compared to whole blood tacrolimus concentrations, plasma tacrolimus concentration showed a strong negative association with worse HRQoL (PCS: st. β = −0.12, p = 0.01; MCS: st. β = −0.14, p < 0.001). The associations between plasma tacrolimus concentrations and HRQoL were mediated by fatigue severity (proportion mediated on PCS: 67.8%, MCS: 59.5%) and reduced kidney function (proportion mediated on PCS: 16.7%, MCS: 12.9%). Conclusions: In conclusion, compared with whole blood tacrolimus concentrations, plasma tacrolimus concentrations exhibited a negative association with HRQoL in KTRs. Consequently, therapeutic drug monitoring using plasma tacrolimus concentrations may reduce the occurrence of tacrolimus-related toxicity.
- 30 April 2025
- Published by MDPI AG in Pharmaceutics
- Vol. 17 (5) , 590
Open AccessPlasma Versus Whole Blood Tacrolimus Concentrations and Health-Related Quality of Life in Kidney Transplant Recipients
Background/Objectives: Tacrolimus dosing traditionally relies on therapeutic drug monitoring in whole blood, while assessment in plasma may better reflect its effect and reveal overdosing impacting health-related quality of life (HRQoL). Methods: In this cross-sectional study, 898 kidney transplant recipients (KTRs) who were at least 12 months post-transplantation were included. Plasma and whole blood tacrolimus concentrations were compared using Passing–Bablok regression analyses and Bland–Altman plots. Furthermore, the relationship with daily tacrolimus dose and with HRQoL (mental component summary (MCS), physical component summary (PCS)) was explored using linear regression by comparing standardized coefficients. Lastly, mediation analyses explored the effect of various tacrolimus-related side effects on the association between tacrolimus concentrations and HRQoL. Results: Comparison of the methods revealed a constant bias and a slight proportional bias between whole blood and plasma tacrolimus concentrations. The Bland–Altman plots indicated poor agreement with a statistically significant ratio difference (p < 0.001). Both whole blood and plasma concentrations were significantly associated with daily tacrolimus dose (both p < 0.001). Compared to whole blood tacrolimus concentrations, plasma tacrolimus concentration showed a strong negative association with worse HRQoL (PCS: st. β = −0.12, p = 0.01; MCS: st. β = −0.14, p < 0.001). The associations between plasma tacrolimus concentrations and HRQoL were mediated by fatigue severity (proportion mediated on PCS: 67.8%, MCS: 59.5%) and reduced kidney function (proportion mediated on PCS: 16.7%, MCS: 12.9%). Conclusions: In conclusion, compared with whole blood tacrolimus concentrations, plasma tacrolimus concentrations exhibited a negative association with HRQoL in KTRs. Consequently, therapeutic drug monitoring using plasma tacrolimus concentrations may reduce the occurrence of tacrolimus-related toxicity.
- 13 August 2024
- Published by University of Groningen Press
Optimising tacrolimus treatment in solid organ transplant recipients
- 13 August 2024
- Published by University of Groningen Press
Optimising tacrolimus treatment in solid organ transplant recipients
- Open Access
- 7 June 2024
- Published by Wolters Kluwer Health in Therapeutic Drug Monitoring
- Vol. 46 (4) , 554-555
Medication Adherence Monitoring Using Alternative Sample Matrices: Bridging the Gap Between Analytical Validation and Clinical Interpretation
- 7 June 2024
- Published by Wolters Kluwer Health in Therapeutic Drug Monitoring
- Vol. 46 (4) , 554-555
Open AccessMedication Adherence Monitoring Using Alternative Sample Matrices: Bridging the Gap Between Analytical Validation and Clinical Interpretation
- 9 September 2023
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 62 (suppl 67) , PA3359
Treatment of fungal infections in lung transplant recipients: is standard dose adjustment of tacrolimus sufficient?
Background Lung transplant recipients (LTR) are at high risk for opportunistic fungal infections (FI). Yet, treatment with azoles results in drug-drug interactions with tacrolimus, requiring dose adjustment (voriconazole: 67%, fluconazole: 40%). We assessed the interaction magnitude, defined by change in tacrolimus dose-corrected trough concentration (C/D) and its influencing factors. Methods In this retrospective study, LTR using tacrolimus p.o. and azoles for FI in 2018-2022 were included. Demographics, drug formulation, doses, concentrations, and blood tests (albumin, ALAT, CRP, eGFR, Hct) were extracted from patient records. Change in C/D before, during and after azole treatment were calculated. Spearman’s correlations of C/D during treatment with demographics and lab parameters were assessed using SPSS. Results In total, 33 LTR were included with 523 tacrolimus concentrations. C/D increased after azole start, median [IQR] 4 times [2.7-6.1] for voriconazole (n=22), and 2 times [1.4-3.7] for fluconazole (n=11), suggesting median dose reductions of 75% and 50% respectively. Median first tacrolimus concentrations after azole start were 13.8 µg/L (range: 5.7-46.1 µg/L) for voriconazole and 11.1 µg/L (2.8-28.9) for fluconazole, compared to 9.2 µg/L (5.2-14.9) before start. C/D during treatment was correlated with C/D before treatment (r=0.60, p<.001), BMI (r=.36, p<.05), and Hct (r=-.46, p<.01). After the 3rd sample after azole discontinuation, median C/D was comparable with before treatment. Conclusion: The drug-drug interaction magnitude between tacrolimus and azoles is variable, and current guidelines for precautionary dose adjustment may not be sufficient.
- 9 September 2023
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 62 (suppl 67) , PA3359
Treatment of fungal infections in lung transplant recipients: is standard dose adjustment of tacrolimus sufficient?
Background Lung transplant recipients (LTR) are at high risk for opportunistic fungal infections (FI). Yet, treatment with azoles results in drug-drug interactions with tacrolimus, requiring dose adjustment (voriconazole: 67%, fluconazole: 40%). We assessed the interaction magnitude, defined by change in tacrolimus dose-corrected trough concentration (C/D) and its influencing factors. Methods In this retrospective study, LTR using tacrolimus p.o. and azoles for FI in 2018-2022 were included. Demographics, drug formulation, doses, concentrations, and blood tests (albumin, ALAT, CRP, eGFR, Hct) were extracted from patient records. Change in C/D before, during and after azole treatment were calculated. Spearman’s correlations of C/D during treatment with demographics and lab parameters were assessed using SPSS. Results In total, 33 LTR were included with 523 tacrolimus concentrations. C/D increased after azole start, median [IQR] 4 times [2.7-6.1] for voriconazole (n=22), and 2 times [1.4-3.7] for fluconazole (n=11), suggesting median dose reductions of 75% and 50% respectively. Median first tacrolimus concentrations after azole start were 13.8 µg/L (range: 5.7-46.1 µg/L) for voriconazole and 11.1 µg/L (2.8-28.9) for fluconazole, compared to 9.2 µg/L (5.2-14.9) before start. C/D during treatment was correlated with C/D before treatment (r=0.60, p<.001), BMI (r=.36, p<.05), and Hct (r=-.46, p<.01). After the 3rd sample after azole discontinuation, median C/D was comparable with before treatment. Conclusion: The drug-drug interaction magnitude between tacrolimus and azoles is variable, and current guidelines for precautionary dose adjustment may not be sufficient.
- Open Access
- 19 May 2023
- Published by Elsevier in Journal of Chromatography A
- Vol. 1702, 464086
Ultra-high throughput dual channel liquid chromatography with tandem mass spectrometry for quantification of four immunosuppressants in whole blood for therapeutic drug monitoring
- 19 May 2023
- Published by Elsevier in Journal of Chromatography A
- Vol. 1702, 464086
Open AccessUltra-high throughput dual channel liquid chromatography with tandem mass spectrometry for quantification of four immunosuppressants in whole blood for therapeutic drug monitoring
- Open Access
- 7 April 2023
- Published by Elsevier in Journal of Chromatography B
- Vol. 1222, 123709
Expeditious quantification of plasma tacrolimus with liquid chromatography tandem mass spectrometry in solid organ transplantation
- 7 April 2023
- Published by Elsevier in Journal of Chromatography B
- Vol. 1222, 123709
Open AccessExpeditious quantification of plasma tacrolimus with liquid chromatography tandem mass spectrometry in solid organ transplantation
- Open Access
- 13 September 2022
- Published by Taylor & Francis in Patient Preference and Adherence
- Vol. ume 16, 2543-2558
Electronic Smart Blister Packages to Monitor and Support Medication Adherence: A Usability Study
Purpose: An electronic version of the Dosepak® (EDP) which records date and time of dosing events has been developed to monitor adherence to medication packaged in blisters. This study aimed to evaluate its usability and acceptance and to monitor dose-taking adherence for optimal implementation in future clinical trials and practice. Methods: Healthy volunteers aged over 18 years were asked to dispense placebo tablets twice daily from EDPs equipped with a re-usable electronic module for a total duration of four weeks. Afterwards, subjects were asked to complete an online questionnaire and partake in a short one-on-one interview. The usability of the EDP was assessed using the System Usability Scale (SUS), while dose-taking adherence was monitored by EDP records, pill counting, and self-report. The short interview explored user experiences in more detail. Results: Twenty subjects with median [IQR] age 41.5 [32– 49.8] years, 55% female, 45% healthcare professionals, and 20% chronic medication users completed the study and found the EDP easy to use, with a mean [SD] SUS score of 78.0 [11.2]. Median [IQR] dose-taking adherence was 89% [82– 95%] based on EDP records, 96.5% [89– 100%] based on pill counting, 92% [91– 96%] based on self-report, and the levels differed significantly (p < 0.05). Four themes emerged from the interviews: user preference, experience, patient burden, and ideas for improvement. Most participants preferred smaller sized blisters. They found the EDP simple to use and did not see any patient burden for its use in trials or clinical practice. Some reported forgetfulness and suggested reminders built into the blister or sent to their mobile phones. Adequate information or instruction should also be provided for older people and polypharmacy patients. Conclusion: EDP had good perceived usability, was well accepted, and differed significantly from other adherence measurement methods. This study provides input to further guide scale-up of the blister packages.
- 13 September 2022
- Published by Taylor & Francis in Patient Preference and Adherence
- Vol. ume 16, 2543-2558
Open AccessElectronic Smart Blister Packages to Monitor and Support Medication Adherence: A Usability Study
Purpose: An electronic version of the Dosepak® (EDP) which records date and time of dosing events has been developed to monitor adherence to medication packaged in blisters. This study aimed to evaluate its usability and acceptance and to monitor dose-taking adherence for optimal implementation in future clinical trials and practice. Methods: Healthy volunteers aged over 18 years were asked to dispense placebo tablets twice daily from EDPs equipped with a re-usable electronic module for a total duration of four weeks. Afterwards, subjects were asked to complete an online questionnaire and partake in a short one-on-one interview. The usability of the EDP was assessed using the System Usability Scale (SUS), while dose-taking adherence was monitored by EDP records, pill counting, and self-report. The short interview explored user experiences in more detail. Results: Twenty subjects with median [IQR] age 41.5 [32– 49.8] years, 55% female, 45% healthcare professionals, and 20% chronic medication users completed the study and found the EDP easy to use, with a mean [SD] SUS score of 78.0 [11.2]. Median [IQR] dose-taking adherence was 89% [82– 95%] based on EDP records, 96.5% [89– 100%] based on pill counting, 92% [91– 96%] based on self-report, and the levels differed significantly (p < 0.05). Four themes emerged from the interviews: user preference, experience, patient burden, and ideas for improvement. Most participants preferred smaller sized blisters. They found the EDP simple to use and did not see any patient burden for its use in trials or clinical practice. Some reported forgetfulness and suggested reminders built into the blister or sent to their mobile phones. Adequate information or instruction should also be provided for older people and polypharmacy patients. Conclusion: EDP had good perceived usability, was well accepted, and differed significantly from other adherence measurement methods. This study provides input to further guide scale-up of the blister packages.
- Open Access
- 1 November 2021
- Published by Springer Nature in Drugs
- Vol. 81 (17) , 1983-2002
Clinical Value of Emerging Bioanalytical Methods for Drug Measurements: A Scoping Review of Their Applicability for Medication Adherence and Therapeutic Drug Monitoring
Introduction Direct quantification of drug concentrations allows for medication adherence monitoring (MAM) and therapeutic drug monitoring (TDM). Multiple less invasive methods have been developed in recent years: dried blood spots (DBS), saliva, and hair analyses. Aim To provide an overview of emerging drug quantification methods for MAM and TDM, focusing on the clinical validation of methods in patients prescribed chronic drug therapies. Methods A scoping review was performed using a systematic search in three electronic databases covering the period 2000–2020. Screening and inclusion were performed by two independent reviewers in Rayyan. Data from the articles were aggregated in a REDCap database. The main outcome was clinical validity of methods based on study sample size, means of cross-validation, and method description. Outcomes were reported by matrix, therapeutic area and application (MAM and/or TDM). Results A total of 4590 studies were identified and 175 articles were finally included; 57 on DBS, 66 on saliva and 55 on hair analyses. Most reports were in the fields of neurological diseases (37%), infectious diseases (31%), and transplantation (14%). An overview of clinical validation was generated of all measured drugs. A total of 62 drugs assays were applied for MAM and 131 for TDM. Conclusion MAM and TDM are increasingly possible without traditional invasive blood sampling: the strengths and limitations of DBS, saliva, and hair differ, but all have potential for valid and more convenient drug monitoring. To strengthen the quality and comparability of future evidence, standardisation of the clinical validation of the methods is recommended.
- 1 November 2021
- Published by Springer Nature in Drugs
- Vol. 81 (17) , 1983-2002
Open AccessClinical Value of Emerging Bioanalytical Methods for Drug Measurements: A Scoping Review of Their Applicability for Medication Adherence and Therapeutic Drug Monitoring
Introduction Direct quantification of drug concentrations allows for medication adherence monitoring (MAM) and therapeutic drug monitoring (TDM). Multiple less invasive methods have been developed in recent years: dried blood spots (DBS), saliva, and hair analyses. Aim To provide an overview of emerging drug quantification methods for MAM and TDM, focusing on the clinical validation of methods in patients prescribed chronic drug therapies. Methods A scoping review was performed using a systematic search in three electronic databases covering the period 2000–2020. Screening and inclusion were performed by two independent reviewers in Rayyan. Data from the articles were aggregated in a REDCap database. The main outcome was clinical validity of methods based on study sample size, means of cross-validation, and method description. Outcomes were reported by matrix, therapeutic area and application (MAM and/or TDM). Results A total of 4590 studies were identified and 175 articles were finally included; 57 on DBS, 66 on saliva and 55 on hair analyses. Most reports were in the fields of neurological diseases (37%), infectious diseases (31%), and transplantation (14%). An overview of clinical validation was generated of all measured drugs. A total of 62 drugs assays were applied for MAM and 131 for TDM. Conclusion MAM and TDM are increasingly possible without traditional invasive blood sampling: the strengths and limitations of DBS, saliva, and hair differ, but all have potential for valid and more convenient drug monitoring. To strengthen the quality and comparability of future evidence, standardisation of the clinical validation of the methods is recommended.
- Open Access
- 1 March 2020
- Published by Taylor & Francis in Patient Preference and Adherence
- Vol. ume 14, 625-634
User Acceptability and Technical Robustness Evaluation of a Novel Smart Pill Bottle Prototype Designed to Support Medication Adherence
Purpose: Smart medication adherence monitoring devices can provide objective and granular drug utilization data and help patients engaging with their treatment. In this proof-of-concept study, the acceptability and technical robustness of a novel smart pill bottle prototype (SPBP) were assessed in order to allow further optimization. Methods: The SPBP is an app-controlled automatic dispense system, capturing real-time data on a web-based platform, which sends text reminders and measures storage conditions. A heterogeneous group of ten volunteers was asked to dispense placebo capsules with the SPBP and to follow a predefined dosing schedule for a trial period of 2 weeks. Afterwards, a questionnaire was filled out during a short interview. Primary outcome was dispense adherence as measured by the bottle. Other study outcomes included system acceptability (System Usability Scale [SUS]), self-reported adherence (MARS) and technical robustness of the bottle’s mechanics (electronic pill dispenser) and sensors (bottle temperature). Results: The overall dispense adherence rate as measured by the SPBP was 88%. All participants completed the study and four participants had an adherence rate of 100% during the study. The dispense adherence rates corresponded well with participants’ self-reported adherence with an average MARS total score of 23.6 (out of 25). Participants judged the system easy to use, with a mean SUS score of 79.3 (range: 57.5– 97.5). The overall mean temperature difference between the bottle sensor and calibrated external sensor was − 0.82°C (range: − 1.37°C to − 0.21°C). Conclusion: The SPBP was well accepted and this study provides data for further optimization and follow-up studies. Smart adherence technologies such as these may change the way healthcare professionals, trialists and patients manage medication adherence.
- 1 March 2020
- Published by Taylor & Francis in Patient Preference and Adherence
- Vol. ume 14, 625-634
Open AccessUser Acceptability and Technical Robustness Evaluation of a Novel Smart Pill Bottle Prototype Designed to Support Medication Adherence
Purpose: Smart medication adherence monitoring devices can provide objective and granular drug utilization data and help patients engaging with their treatment. In this proof-of-concept study, the acceptability and technical robustness of a novel smart pill bottle prototype (SPBP) were assessed in order to allow further optimization. Methods: The SPBP is an app-controlled automatic dispense system, capturing real-time data on a web-based platform, which sends text reminders and measures storage conditions. A heterogeneous group of ten volunteers was asked to dispense placebo capsules with the SPBP and to follow a predefined dosing schedule for a trial period of 2 weeks. Afterwards, a questionnaire was filled out during a short interview. Primary outcome was dispense adherence as measured by the bottle. Other study outcomes included system acceptability (System Usability Scale [SUS]), self-reported adherence (MARS) and technical robustness of the bottle’s mechanics (electronic pill dispenser) and sensors (bottle temperature). Results: The overall dispense adherence rate as measured by the SPBP was 88%. All participants completed the study and four participants had an adherence rate of 100% during the study. The dispense adherence rates corresponded well with participants’ self-reported adherence with an average MARS total score of 23.6 (out of 25). Participants judged the system easy to use, with a mean SUS score of 79.3 (range: 57.5– 97.5). The overall mean temperature difference between the bottle sensor and calibrated external sensor was − 0.82°C (range: − 1.37°C to − 0.21°C). Conclusion: The SPBP was well accepted and this study provides data for further optimization and follow-up studies. Smart adherence technologies such as these may change the way healthcare professionals, trialists and patients manage medication adherence.