Sanjay Nadkarni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sanjay Nadkarni has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Jonathan Tibballs
Department of Interventional Radiology, Sir Charles Gairdner Hospital, Perth, Australia
3 shared publications - Albert Ho Yuen Chiu
Neurological Intervention & Imaging Service of Western Australia (NIISwa), Sir Charles Gairdner, Royal Perth and Fiona Stanley Hospitals, Western Australia Department of Health, Nedlands, Western Australia, Australia
2 shared publications David E. Hartley
Cook R&D, Perth, Western Australia
2 shared publicationsMarek Garbowski
Department of Vascular Surgery, Sir Charles Gairdner Hospital, Western Australia 6008, Australia
2 shared publicationsMichael M. D. Lawrence-Brown
School of Public Health, Curtin University of Technology, Perth, Western Australia
2 shared publicationsRoslyn Knight
Department of Radiology, Sir Charles Gairdner Hospital, Perth, Australia
2 shared publications
Latest Publications
- 26 February 2010
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 17 (1) , 46-50
The StarClose Vascular Closure Device in Antegrade and Retrograde Punctures: A Single-Center Experience
Purpose: To evaluate the StarClose device and compare its success rates in antegrade and retrograde puncture closures. Methods: A retrospective review of all StarClose deployments from April 2005 to July 2007 was performed in a single tertiary referral institution radiology department. In this time period, 143 StarClose devices were deployed in 132 patients (102 men; mean age 68±14 years). Of these, 40 (28%) were deployed after antegrade and 103 (72%) after retrograde common femoral arterial punctures. Hospital notes were reviewed to evaluate minor (managed conservatively with compression) and major (requiring surgical intervention) complication rates in the immediate postprocedure period and the following 24 hours. Late complications were also assessed. Results: There were 11 (7.7%) immediate failures of device deployment: 4/40 (10.0%) antegrade and 7/103 (6.8%) retrograde. Within these 11 punctures, 1 major complication occurred that required surgical retrieval of the device following a retrograde puncture. No other major and 12 (9.1%) minor complications occurred following the 132 successful StarClose deployments. No late complications were seen on clinical or radiological follow-up. The total major complication rate was 0.7% (1/143). The total minor complication rate was 15.4% (22/143): 9/40 (22.5%) following antegrade punctures and 13/103 (12.6%) following retrograde punctures. Conclusion: The StarClose device is associated with a low major complication rate. A higher rate of minor complications was observed following antegrade punctures but all were managed with simple compression. Prospective randomized trials comparing closure devices are needed to evaluate their relative efficacy and safety in antegrade and retrograde punctures.
- 26 February 2010
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 17 (1) , 46-50
The StarClose Vascular Closure Device in Antegrade and Retrograde Punctures: A Single-Center Experience
Purpose: To evaluate the StarClose device and compare its success rates in antegrade and retrograde puncture closures. Methods: A retrospective review of all StarClose deployments from April 2005 to July 2007 was performed in a single tertiary referral institution radiology department. In this time period, 143 StarClose devices were deployed in 132 patients (102 men; mean age 68±14 years). Of these, 40 (28%) were deployed after antegrade and 103 (72%) after retrograde common femoral arterial punctures. Hospital notes were reviewed to evaluate minor (managed conservatively with compression) and major (requiring surgical intervention) complication rates in the immediate postprocedure period and the following 24 hours. Late complications were also assessed. Results: There were 11 (7.7%) immediate failures of device deployment: 4/40 (10.0%) antegrade and 7/103 (6.8%) retrograde. Within these 11 punctures, 1 major complication occurred that required surgical retrieval of the device following a retrograde puncture. No other major and 12 (9.1%) minor complications occurred following the 132 successful StarClose deployments. No late complications were seen on clinical or radiological follow-up. The total major complication rate was 0.7% (1/143). The total minor complication rate was 15.4% (22/143): 9/40 (22.5%) following antegrade punctures and 13/103 (12.6%) following retrograde punctures. Conclusion: The StarClose device is associated with a low major complication rate. A higher rate of minor complications was observed following antegrade punctures but all were managed with simple compression. Prospective randomized trials comparing closure devices are needed to evaluate their relative efficacy and safety in antegrade and retrograde punctures.
- 1 June 2008
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 15 (3) , 315-321
Comparison of Arterial Closure Devices in Antegrade and Retrograde Punctures
Purpose: To compare the efficacy, primary failure rates, and complications for the Angio-Seal and Perclose closure devices in antegrade and retrograde common femoral artery (CFA) punctures during peripheral angioplasty procedures. Methods: A retrospective single-center analysis was conducted between April 2002 and June 2006 of all patients who had a CFA puncture and no other intervention planned during the same admission. Patients undergoing thrombolysis were excluded. Of 215 punctures in 191 patients, 123 closures in 97 patients (82 men; mean age 69.5 ± 10.4 years, range 41–93) were eligible for analysis. Of these, 49 punctures were antegrade and 74 were retrograde. An Angio-Seal device was used in 40 closures, while 83 punctures were closed with a Perclose device. Deployment outcomes and complications were compared between devices for each puncture direction and between antegrade and retrograde punctures. Results: Seventy-eight (63.4%) of the 123 closures reached the primary endpoint of complication-free progress to discharge, comprising 30 (61.2%) of the 49 antegrade closures and 48 (64.9%) of the 74 retrograde closures. There was no significant difference between the devices for the primary endpoint. Twenty-two (17.9%) attempted closures failed. Forty-one (33.3%) closures had a complication after the procedure, but none required further intervention. In antegrade closures, Angio-Seal had a significantly lower rate of primary failure (11.1% versus 38.7% for Perclose, p=0.038). Antegrade closures had a higher rate of primary failure (pConclusion: Angio-Seal had a lower rate of primary failure than Perclose in antegrade puncture closures. We believe this reinforces the need for larger studies to compare closure devices in antegrade punctures.
- 1 June 2008
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 15 (3) , 315-321
Comparison of Arterial Closure Devices in Antegrade and Retrograde Punctures
Purpose: To compare the efficacy, primary failure rates, and complications for the Angio-Seal and Perclose closure devices in antegrade and retrograde common femoral artery (CFA) punctures during peripheral angioplasty procedures. Methods: A retrospective single-center analysis was conducted between April 2002 and June 2006 of all patients who had a CFA puncture and no other intervention planned during the same admission. Patients undergoing thrombolysis were excluded. Of 215 punctures in 191 patients, 123 closures in 97 patients (82 men; mean age 69.5 ± 10.4 years, range 41–93) were eligible for analysis. Of these, 49 punctures were antegrade and 74 were retrograde. An Angio-Seal device was used in 40 closures, while 83 punctures were closed with a Perclose device. Deployment outcomes and complications were compared between devices for each puncture direction and between antegrade and retrograde punctures. Results: Seventy-eight (63.4%) of the 123 closures reached the primary endpoint of complication-free progress to discharge, comprising 30 (61.2%) of the 49 antegrade closures and 48 (64.9%) of the 74 retrograde closures. There was no significant difference between the devices for the primary endpoint. Twenty-two (17.9%) attempted closures failed. Forty-one (33.3%) closures had a complication after the procedure, but none required further intervention. In antegrade closures, Angio-Seal had a significantly lower rate of primary failure (11.1% versus 38.7% for Perclose, p=0.038). Antegrade closures had a higher rate of primary failure (pConclusion: Angio-Seal had a lower rate of primary failure than Perclose in antegrade puncture closures. We believe this reinforces the need for larger studies to compare closure devices in antegrade punctures.
- 1 February 2008
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 15 (1) , 42-51
CT Virtual Intravascular Endoscopy in the Visualization of Fenestrated Stent-Grafts
Purpose: To report the diagnostic value of computed tomographic (CT) virtual intravascular endoscopy (VIE) in the assessment of patients with abdominal aortic aneurysm (AAA) treated with fenestrated endovascular grafts. Methods: Eight patients (7 men; mean age 76 years, range 70–82) with AAAs unsuitable for open surgery or conventional endovascular repair had fenestrated endovascular grafts implanted. Both pre- and post-fenestration multislice CT data were used to generate VIE images of the visceral artery ostia and the side branch fenestrated stents. CT VIE images were compared with conventional 2-dimensional (2D) axial CT and multiplanar reformatted (MPR) images for the ability to visualize the intraluminal appearance of stents, as well as to measure the length of stents that protruded into the aortic lumen. Results: Various fenestrations were deployed in 27 aortic branches. Scalloped and large fenestrations were implanted in 6 side branch ostia, respectively, and small fenestrations in 15 renal artery ostia. Fewer than half of the stents (37%) were found to be circular on VIE images, while the remaining stents were flared to varying extents at the inferior portion. The majority (96%) of stents protruded into the lumen up to 7.0 mm. Although the configuration of the side branch ostia changed to a variable extent, no significant difference was apparent between the diameters of branch ostia before and after fenestration (p>0.05). Conclusion: Our preliminary study shows that VIE proved superior to conventional 2D or MPR images in visualizing the final configuration of the fenestrated vessels and was comparable to the other techniques in measuring stent protrusion into the aortic lumen. VIE could be a valuable technique to identify any suspected abnormalities associated with fenestrated endovascular grafts by demonstrating the final intraluminal configuration of the stents in the fenestrated vessels.
- 1 February 2008
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 15 (1) , 42-51
CT Virtual Intravascular Endoscopy in the Visualization of Fenestrated Stent-Grafts
Purpose: To report the diagnostic value of computed tomographic (CT) virtual intravascular endoscopy (VIE) in the assessment of patients with abdominal aortic aneurysm (AAA) treated with fenestrated endovascular grafts. Methods: Eight patients (7 men; mean age 76 years, range 70–82) with AAAs unsuitable for open surgery or conventional endovascular repair had fenestrated endovascular grafts implanted. Both pre- and post-fenestration multislice CT data were used to generate VIE images of the visceral artery ostia and the side branch fenestrated stents. CT VIE images were compared with conventional 2-dimensional (2D) axial CT and multiplanar reformatted (MPR) images for the ability to visualize the intraluminal appearance of stents, as well as to measure the length of stents that protruded into the aortic lumen. Results: Various fenestrations were deployed in 27 aortic branches. Scalloped and large fenestrations were implanted in 6 side branch ostia, respectively, and small fenestrations in 15 renal artery ostia. Fewer than half of the stents (37%) were found to be circular on VIE images, while the remaining stents were flared to varying extents at the inferior portion. The majority (96%) of stents protruded into the lumen up to 7.0 mm. Although the configuration of the side branch ostia changed to a variable extent, no significant difference was apparent between the diameters of branch ostia before and after fenestration (p>0.05). Conclusion: Our preliminary study shows that VIE proved superior to conventional 2D or MPR images in visualizing the final configuration of the fenestrated vessels and was comparable to the other techniques in measuring stent protrusion into the aortic lumen. VIE could be a valuable technique to identify any suspected abnormalities associated with fenestrated endovascular grafts by demonstrating the final intraluminal configuration of the stents in the fenestrated vessels.
- 1 April 2007
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 14 (2) , 257-259
Digital Embolization Due to Partially Uncovered Left Subclavian Artery Post TEVAR: Management with Amplatzer Vascular Plug Occlusion
Purpose: To describe the use of the Amplatzer vascular plug to treat a partially uncovered left subclavian artery (LSA) causing digital embolism following thoracic endovascular aneurysm repair. Case Report: A 70-year-old man presented with digital ischemia of the left index and middle fingers due to embolism from a partially covered LSA orifice during thoracic endovascular aneurysm repair for a type I thoracic aortic aneurysm. The orifice was successfully occluded using the vascular plug, supplemented by a left carotid-subclavian bypass to treat ongoing arm and hand claudication. The patient has had no further embolic episodes. Conclusion: A partially uncovered LSA during thoracic endovascular aneurysm repair poses a risk of thromboembolism, with resultant upper limb claudication or tissue loss. If recognized at the time of the procedure, this should be treated by proximal extension; otherwise, proximal LSA occlusion using an Amplatzer occluder may be a safe and effective option in preventing further embolic episodes.
- 1 April 2007
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 14 (2) , 257-259
Digital Embolization Due to Partially Uncovered Left Subclavian Artery Post TEVAR: Management with Amplatzer Vascular Plug Occlusion
Purpose: To describe the use of the Amplatzer vascular plug to treat a partially uncovered left subclavian artery (LSA) causing digital embolism following thoracic endovascular aneurysm repair. Case Report: A 70-year-old man presented with digital ischemia of the left index and middle fingers due to embolism from a partially covered LSA orifice during thoracic endovascular aneurysm repair for a type I thoracic aortic aneurysm. The orifice was successfully occluded using the vascular plug, supplemented by a left carotid-subclavian bypass to treat ongoing arm and hand claudication. The patient has had no further embolic episodes. Conclusion: A partially uncovered LSA during thoracic endovascular aneurysm repair poses a risk of thromboembolism, with resultant upper limb claudication or tissue loss. If recognized at the time of the procedure, this should be treated by proximal extension; otherwise, proximal LSA occlusion using an Amplatzer occluder may be a safe and effective option in preventing further embolic episodes.
- 1 June 2006
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 13 (3) , 320-329
Outcomes of Fenestrated Endografts in the Treatment of Abdominal Aortic Aneurysm in Western Australia (1997–2004)
Purpose: To describe a 7-year experience with abdominal aortic aneurysm (AAA) repair using fenestrated Zenith endovascular endografts. Methods: Six endovascular surgeons from 7 medical centers in Perth, Western Australia, contributed data to this retrospective study of 58 AAA patients (51 men; mean age 75.5±8.5 years, range 60–94) treated with fenestrated endografts. Fenestrations were applied to 116 target vessels; more than half of patients had ≥2 target vessels. The results were based on satisfactory deployment of the stent-graft and fenestrations (technical success), technical success and no complications (procedural success), and aneurysm exclusion with no endoleak, rupture, unresolved complications, or dialysis (treatment success). Results: Technical success was 82.8% for patients (90.5% for target vessels), procedural success was 74.1%, and treatment success was 94.8%. There were no cases of conversion or rupture. The 30-day mortality rate was 3.4% (n=2). Over a mean follow-up of 1.4±1.2 years, 10 (17.2%) patients experienced loss of a target vessel (9.5% of target vessels). Factors associated with target vessel loss were no stent, >60° neck angulation, multiple renal vessels, and vessel diameter ≤4 mm. Four (6.9%) patients developed renal impairment, but none required dialysis. Fourteen (24.1%) patients had a secondary intervention. Unresolved endoleaks persisted in 1 (1.7%) patient. Conclusion: Fenestrated endografts extend the treatment options for infrarenal AAAs with necks unsuitable for standard endovascular repair. This early data show a trend toward higher mortality of selected patients with fenestrated endografts than for standard stent-graft repair, but the mortality rate is comparable to open repair. Target vessel occlusion predominantly results from pre-existing disease or the lack of a stent. The lessons learned from this experience contributed toward guidelines for users of fenestrated endografts.
- 1 June 2006
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 13 (3) , 320-329
Outcomes of Fenestrated Endografts in the Treatment of Abdominal Aortic Aneurysm in Western Australia (1997–2004)
Purpose: To describe a 7-year experience with abdominal aortic aneurysm (AAA) repair using fenestrated Zenith endovascular endografts. Methods: Six endovascular surgeons from 7 medical centers in Perth, Western Australia, contributed data to this retrospective study of 58 AAA patients (51 men; mean age 75.5±8.5 years, range 60–94) treated with fenestrated endografts. Fenestrations were applied to 116 target vessels; more than half of patients had ≥2 target vessels. The results were based on satisfactory deployment of the stent-graft and fenestrations (technical success), technical success and no complications (procedural success), and aneurysm exclusion with no endoleak, rupture, unresolved complications, or dialysis (treatment success). Results: Technical success was 82.8% for patients (90.5% for target vessels), procedural success was 74.1%, and treatment success was 94.8%. There were no cases of conversion or rupture. The 30-day mortality rate was 3.4% (n=2). Over a mean follow-up of 1.4±1.2 years, 10 (17.2%) patients experienced loss of a target vessel (9.5% of target vessels). Factors associated with target vessel loss were no stent, >60° neck angulation, multiple renal vessels, and vessel diameter ≤4 mm. Four (6.9%) patients developed renal impairment, but none required dialysis. Fourteen (24.1%) patients had a secondary intervention. Unresolved endoleaks persisted in 1 (1.7%) patient. Conclusion: Fenestrated endografts extend the treatment options for infrarenal AAAs with necks unsuitable for standard endovascular repair. This early data show a trend toward higher mortality of selected patients with fenestrated endografts than for standard stent-graft repair, but the mortality rate is comparable to open repair. Target vessel occlusion predominantly results from pre-existing disease or the lack of a stent. The lessons learned from this experience contributed toward guidelines for users of fenestrated endografts.
- 9 December 2005
- Published by Wiley in Anz Journal of Surgery
- Vol. 75 (12) , 1120-1122
Cystic adventitial disease: a case report and literature review
Cystic adventitial disease (CAD) is a rare non‐atherosclerotic cause of peripheral vascular disease (PVD). We describe a 54‐year‐old man who presented with calf claudication and catheter angiography showed the typical scallop appearances of CAD. Surgery involved resection of the diseased segment with a femoral popliteal venous bypass graft. A literature review revealed the different theories for pathogenesis, the investigation of choice being catheter angiography and the treatment excision with bypass grafting.
- 9 December 2005
- Published by Wiley in Anz Journal of Surgery
- Vol. 75 (12) , 1120-1122
Cystic adventitial disease: a case report and literature review
Cystic adventitial disease (CAD) is a rare non‐atherosclerotic cause of peripheral vascular disease (PVD). We describe a 54‐year‐old man who presented with calf claudication and catheter angiography showed the typical scallop appearances of CAD. Surgery involved resection of the diseased segment with a femoral popliteal venous bypass graft. A literature review revealed the different theories for pathogenesis, the investigation of choice being catheter angiography and the treatment excision with bypass grafting.
- 1 December 2002
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 25 (6) , 524-526
Placement of a Retrievable Günther Tulip Filter in the Superior Vena Cava for Upper Extremity Deep Venous Thrombosis
A retrievable Günther Tulip caval filter (William Cook, Europe) was successfully placed and retrieved in the superior vena cava for upper extremity deep venous thrombosis in a 56-year-old woman. Bilateral subclavian and internal jugular venous thromboses thought secondary to placement of multiple central venous catheters were present. There have been reports of the use of permanent Greenfield filters and a single case report of a temporary filter in the superior vena cava. As far as we are aware this is the first reported placement and successful retrieval of a filter in these circumstances.
- 1 December 2002
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 25 (6) , 524-526
Placement of a Retrievable Günther Tulip Filter in the Superior Vena Cava for Upper Extremity Deep Venous Thrombosis
A retrievable Günther Tulip caval filter (William Cook, Europe) was successfully placed and retrieved in the superior vena cava for upper extremity deep venous thrombosis in a 56-year-old woman. Bilateral subclavian and internal jugular venous thromboses thought secondary to placement of multiple central venous catheters were present. There have been reports of the use of permanent Greenfield filters and a single case report of a temporary filter in the superior vena cava. As far as we are aware this is the first reported placement and successful retrieval of a filter in these circumstances.
- 1 May 2001
- Published by Elsevier in Clinical Radiology
- Vol. 56 (5) , 389-392
Herniography: A Prospective, Randomized Study Between Midline and Left Iliac Fossa Puncture Techniques
- 1 May 2001
- Published by Elsevier in Clinical Radiology
- Vol. 56 (5) , 389-392
Herniography: A Prospective, Randomized Study Between Midline and Left Iliac Fossa Puncture Techniques