CSChunguang Suo

Chunguang Suo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chunguang Suo has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Non-contact voltage measurement of residential cables based on internal parameter conversion and centering probe assistance

    by Rujin Huang, Wenbin Zhang, Chunguang Suo

    Existing non-contact voltage measurement technology cannot be applied to residential cables containing neutral wire and earth wire in addition to live wire. A non-contact voltage measurement method of residential cables is introduced in this article. First, an equivalent circuit model of the residential cable measurement based on capacitive coupling is established. In order to solve the problem of uncertain coupling capacitance, which leading to the inability to accurately obtain the voltage amplitude, a calibration method based on internal parameter conversion and centering probe assistance is proposed. This method calibrates the cable voltage through different transfer relationships and sensor outputs, and no known reference excitation is required during calibration. Subsequently, the impact of internal parameters on measurement accuracy are analyzed and selection principles are provided. Through finite element simulation, the influence of metal spring for centering on voltage measurement is analyzed, and the measurement error of non-ideal cables (with eccentricity or ovality) is quantified. A prototype probe and internal parameter conversion circuit have been developed, and parasitic capacitance compensation have been completed. The measurement accuracy of 50 Hz voltage in a certain range (100–300 V) was tested in the laboratory, the maximum relative error of amplitude is −0.89%, and the relative error of phase is 0.68%. Four specifications of residential cables testing were completed, with a maximum relative error of −1.35%. Long- term testing was conducted on the actual field (output voltage of the distribution box), the test results showed that the output was linear, and the relative error were kept around 0.65% after primary calibration.


  • Open Access

    Research on Non-Invasive Floating Ground Voltage Measurement and Calibration Method

    by Chunguang Suo, Mingxing He, Guoqiong Zhou, Xinghua Shi, Xiangyu Tan, Wenbin Zhang

    Voltage measurement is an important part of power system operation, and non-intrusive voltage sensors have the advantages of low insulation difficulty, simple structure, easy loading and unloading, and high construction safety, which have become a new direction for voltage measurement. Based on the principle of electric field coupling, this paper constructs a non-intrusive floating ground three-capacitance voltage measurement model, which can complete the accurate measurement of voltage without connecting with the line to be measured and the earth in the measurement process. In non-intrusive voltage measurement, the change of the object to be measured or the measurement environment will cause the change of the coupling capacitance, which leads to the uncertainty of the transmission relationship of the sensor and the large error of measurement results. In order to solve this problem, a new method of sensor calibration is proposed in this paper. By sampling capacitance in parallel between two electrodes of the sensor, changing the capacitance value, and establishing an input output equation, the coupling capacitance value and the voltage value to be measured under different operating conditions are solved. In addition, the sampling capacitance is often several orders of magnitude larger than the sensor’s own capacitance, making the sensor’s voltage division ratio significantly higher and more conducive to the measurement of high voltages. The experimental results show that the measurement error is less than 2%, which verifies the feasibility of the method and the accuracy of the voltage measurement.


  • Open Access

    Research on Near-Field Propagation Characteristics of Partial Discharge Electromagnetic Wave Signal in Switchgear

    by Chunguang Suo, Jingjing Zhao, Lifeng Wang, Zhipeng Xu, Ruikang Luo, Mingxing He, Wenbin Zhang

    In the authors’ previous research, a new method for partial discharge detection in the switchgear based on near-field detection was proposed. The content of this paper is the continuation of the authors’ previous research. In order to realize the reasonable layout of the near-field magnetic field probe for partial discharge detection in the switchgear, this paper simulates and analyzes the influence of the internal structure of the switchgear on the near-field propagation characteristics of the electromagnetic wave signal generated by partial discharge, and determines the installation position of the near-field probe in the switchgear. Firstly, the propagation characteristics of electromagnetic wave signals in the different media of the switchgear are analyzed, and the switchgear model is established. Then, based on the finite difference time domain method, the influence of different devices in the switchgear on the near-field propagation of the partial discharge electromagnetic wave signal is simulated. The simulation results show that the current transformer, insulator, busbar and cabinet all obviously attenuate the amplitude of the near-field electromagnetic wave signals generated by partial discharge, and the insulator causes obvious signal distortion. Finally, it is determined that the near-field probe can be installed on the inner wall or the right wall near the bottom plate of the switchgear.


  • Open Access

    Self-Calibration Sensor for Contactless Voltage Measurement Based on Dynamic Capacitance

    by Chunguang Suo, Rujin Huang, Guoqiong Zhou, Wenbin Zhang, Yanyun Wang, Mingxing He

    Noncontact voltage measurement has the advantages of simple handling, high construction safety, and not being affected by line insulation. However, in practical measurement of noncontact voltage, sensor gain is affected by wire diameter, wire insulation material, and relative position deviation. At the same time, it is also subject to interference from interphase or peripheral coupling electric fields. This paper proposes a noncontact voltage measurement self-calibration method based on dynamic capacitance, which realizes self-calibration of sensor gain through unknown line voltage to be measured. Firstly, the basic principle of the self-calibration method for noncontact voltage measurement based on dynamic capacitance is introduced. Subsequently, the sensor model and parameters were optimized through error analysis and simulation research. Based on this, a sensor prototype and remote dynamic capacitance control unit that can shield against interference are developed. Finally, the accuracy test, anti-interference ability test, and line adaptability test of the sensor prototype were conducted. The accuracy test showed that the maximum relative error of voltage amplitude was 0.89%, and the phase relative error was 1.57%. The anti-interference ability test showed that the error offset was 0.25% when there were interference sources. The line adaptability test shows that the maximum relative error in testing different types of lines is 1.01%.


  • Open Access

    Non-Contact Measurement Method of Phase Current Based on Magnetic Field Decoupling Calculation for Three-Phase Four-Core Cable

    by Chunguang Suo, Kang Cheng, Lifeng Wang, Wenbin Zhang, Xi Liu, Junyu Zhu

    As one of the important parameters characterizing the cable’s operation status, an accurate measurement of the current is particularly important for the cable’s reliable operation and status monitoring. Aiming at the problem that the sum of the current phasors of multiphase cables is 0 when running in a steady state, and that the traditional mutual inductance current measurement method cannot be used for the phase current measurement of such cables, or that the insulation layer needs to be damaged, this paper proposes a non-contact measurement method of three-phase cable current, based on the magnetic field decoupling calculation. When combined with the actual parameters of the three-phase cable, the analytical calculation model of the magnetic field distribution of the three-phase cable is established. The relationship between the output ratio of the sensor and the deflection angle is obtained through theoretical derivation, the magnetic field coupling coefficient matrix is determined, and the transfer relationship between the output of the magnetic sensor and the current of each phase is clarified; an array magnetic field sensor is designed, which can sense the information of the adjacent magnetic field independently and is used for the reconstruction of three-phase currents. The effectiveness of the proposed method was tested on the built three-phase four-core cable current measurement test platform. The experimental results show that under the three-phase current balance, the measurement error of phase A, phase B and phase C is less than 2.8%, and the waveform and phase angle of the three-phase current can be well restored, which verifies the three-phase current measurement method proposed in this paper.


  • Open Access

    Partial Discharge Detection Technology for Switchgear Based on Near-Field Detection

    by Chunguang Suo, Jingjing Zhao, Xuehua Wu, Zhipeng Xu, Wenbin Zhang, Mingxing He

    In view of the fact that the partial discharge (PD) signal energy is mainly concentrated below hundreds of megahertz, the ultra-high frequency part of the energy is weak, and the interior space of the switchgear is narrow, this paper proposes a new method for PD detection of the switchgear based on near-field detection. Firstly, based on the principle of PD, the field characteristics of the signal in the switchgear are analyzed. After that, the probe is designed with an electric small loop structure. Based on its equivalent circuit, its measurement principle and amplitude frequency characteristics are analyzed. The influence of probe size and material on amplitude frequency characteristics is obtained by using simulation software High Frequency Structure Simulator (HFSS), and the probe parameters suitable for PD detection in the switchgear are determined. Finally, the performance of the probe is measured by network analyzer, and the PD signal is tested on the simulated PD test platform. The results show that the probe works in the frequency band of 10–200 MHz and can receive PD signals containing more energy information. In the operating frequency band, the reflection coefficient of the probe port is very large, and its interference to the signal near field is particularly small. The probe also has good frequency response characteristics, and the fluctuation in the frequency band is less than 5 dB, which can obtain more accurate PD signal characteristics in subsequent processing. In addition, the probe is passive, with dimensions of 166 mm in length, 104 mm in width, and 2 mm in thickness, which is suitable for placing in the switchgear with small internal space. The results of PD receiving test show that the probe can reflect the occurrence of PD remarkably and accurately.


  • Open Access

    Self-Calibration Method of Noncontact AC Voltage Measurement

    by Wenbin Zhang, Ran Wei, Aerduoni Jiu, Kang Cheng, Yonglong Yang, Chunguang Suo

    Realizing stable and reliable monitoring of a distribution network voltage environment can obtain real-time power parameter information and ensure the normal and safe operation of transmission lines, which is of great research significance and engineering value. Based on the distributed capacitance relationship between sensor and transmission line, an equivalent circuit capacitance voltage dividing model is proposed, and the relevant factors affecting the stability of the voltage dividing ratio are analyzed. The self-calibration principle of noncontact AC voltage measurement is proposed based on the system identification theory. The noncontact sensing structure is designed, a sensor probe prototype is fabricated, and a back-end conditioning circuit is designed to realize the overall measurement system. Finally, the validity of the measurement model is verified by simulation and experiment, and a measurement platform is built which proves the feasibility of the self-calibration method for noncontact voltage measurement. The experimental results show that the error is less than ±2%. This method can correctly restore the measured voltage waveform, has good linearity, and can realize wireless data transmission, which provides a new idea for the voltage measurement method of a distribution network.


  • Open Access

    Research on Low-Voltage AC Series Arc-Fault Detection Method Based on Electromagnetic Radiation Characteristics

    by Yi Ke, Wenbin Zhang, Chunguang Suo, Yanyun Wang, Yanan Ren

    Arc fault is an important cause of electrical fire. At present, the arc-fault detection method based on current and voltage is vulnerable to the influence of a nonlinear load and switching operation in the line, resulting in misjudgment and omission. Therefore, an arc-fault detection method based on the characteristics of electromagnetic radiation is proposed. A low-voltage AC series arc-fault simulation platform is built, and a simple annular antenna is designed to receive an electromagnetic radiation signal. It is proved by experiments that electromagnetic radiation signals have similar characteristic frequencies (13.6–14.2 MHz) under different currents, loads, arc positions and arc occurrence times. At the same time, the electromagnetic radiation signal of a low-voltage AC series arc and normal switching operations are compared. The pulse oscillation time of the radiation signals of the operating arc (2 μs) is far shorter than that of the faulty arc (4 μs), and the characteristic frequency of the radiation signal generated by the switching operation (9.35 MHz) is significantly lower than that of the series arc radiation signal (14 MHz). Compared with the existing methods, this method does not need to consider the influence of current, nonlinear load and other factors in the line, and can accurately distinguish the operating arc and faulty arc.


  • Open Access

    Research on UAV Three-Phase Transmission Line Tracking and Localization Method Based on Electric Field Sensor Array

    by Chunguang Suo, Jiawen Zhao, Wenbin Zhang, Peng Li, Rujin Huang, Junyu Zhu, Xiangyu Tan

    The tracking and positioning of transmission lines is a key element for UAVs (Unmanned Aerial Vehicles) to achieve autonomous inspection of transmission lines. Current methods are vulnerable to weather and environmental factors, have high costs, and have difficulties in data processing. Therefore, this paper proposes a transmission line tracking and localization method based on the electric field sensor array, which calculates the current UAV’s heading angle deflection angle, the distance between the transmission line and the UAV, and the elevation angle, providing a new idea to solve the problem of UAV inspection of transmission lines. At the same time, the electric field distribution of different arrangements of three-phase transmission lines was analyzed using COMSOL to determine the flight area of the UAV. By comparing the electric field distribution of the UAV flight area and single-phase transmission lines, it was verified that the current method is also applicable in the three-phase transmission line scenario, and it was further verified that the sensor array used can sense the change of the UAV position in the flight area, indicating that the electric field sensor array can realize the transmission line tracking and localization of transmission lines. The experimental results showed that, in the three-phase transmission line scenario, when the sensor array moves along the transmission straight wire, the maximum absolute error of the heading angle deflection angle calculated according to this method was 8.2°, the maximum absolute error of the distance between the array and the transmission line was 19.3 cm, and the maximum absolute error of the elevation angle was 11.37°; the error was within a reasonable range and can be used for the UAV to realize autonomous inspection.


  • Open Access

    Research on On-Line Detection Method of Transformer Winding Deformation Based on VFTO

    by Yanyun Wang, Guoqiong Zhou, Chunping Zeng, Wenbin Zhang, Yanan Ren, Yi Ke, Hequn Chu, Chunguang Suo

    At present, the detection of transformer winding deformation faults is carried out in an offline state, which requires the transformer to cooperate with the implementation of planned power outages, or it takes place after the sudden failure of the transformer when it is out of operation. It is difficult to obtain the status information of the windings online in time. Since the transformer will suffer very fast transient overvoltage (VFTO) impact during operation, combined with the principle of the frequency response method, an online detection method of transformer winding deformation based on VFTO is proposed. In order to study the frequency response characteristics of transformer winding under the impact of VFTO, the generation process of VFTO is simulated by simulation software, and the equivalent circuit model of transformer winding before and after deformation is established. The VFTO signal is injected into the transformer circuit model as an excitation source, and the changes of resonant frequencies of frequency response curve under different deformation types and different deformation degrees of winding are analyzed. The simulation results show that the frequency response curves of different winding deformation types are different. Different deformation degrees are simulated by increasing the radial capacitance by 4%, 13%, and 23%, series inductance by 2%, 4%, and 6%, and longitudinal capacitance by 3%, 6%, and 9%, and the change of resonance frequencies can comprehensively reflect the deformation information of winding. At the same time, the tests of different deformation types and deformation degrees of the simulated winding are carried out. The results show that with the deepening of the change degree of the simulated fault inductance value, the frequency response curve shifts to the low-frequency direction, confirming the feasibility of the online detection method of transformer winding deformation based on VFTO.