Juliana Tsz Yan Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Juliana Tsz Yan Lee has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Victor Yu Leong Leung
Department of Orthopaedics & Traumatology, The University of Hong Kong, Hong Kong SAR, China
4 shared publications - Kenneth Man Chee Cheung
Department of Orthopaedics and Traumatology, The University of Hong Kong Shenzhen Hospital, Shenzhen, China
3 shared publications Björn Meij
Department of Clinical Sciences of Companion Animals, Faculty of Veterinary Medicine, Utrecht University, Utrecht, The Netherlands
1 shared publicationCora H. Bow
Department of Orthopaedics and Traumatology, The University of Hong Kong, Pokfulam, Hong Kong, SAR, China
1 shared publicationDanhui Cheng
Department of Chemical and Biomolecular Engineering, Fok Ying Tung Graduate School, and Bioengineering Graduate Program, The Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong
1 shared publication- Dino Samartzis
Department of Orthopedic Surgery, Rush University Medical Center, Chicago, USA
1 shared publication
Latest Publications
- Open Access
- 21 June 2015
- Published by Journal of Biological Methods in Journal of Biological Methods
- Vol. 2 (2) , e20
Extraction of RNA from tough tissues with high proteoglycan content by cryosection, second phase separation and high salt precipitation
Reverse-transcription quantitative PCR (RT-qPCR) is a powerful technique for quantification of gene expression. Extraction of RNA directly from human and large animal intervertebral disc (IVD) tissue is technically challenging due to its tough nature, low cell-to-matrix ratio and high proteoglycan content. IVD is consisted of nucleus pulposus (NP) and annulus fibrosis (AF). We compared the yield and quality of RNA extracted from cultured cells using TRIzol and combined TRIzol-column method (TRIspin) with and without bovine NP tissue added for high proteoglycan content simulation. Higher yields were obtained using the TRIzol method compared to the TRIspin method and the quality of RNA extracted using both methods was comparable. Cryosectioning was by far the most effective homogenization method for the tough bovine NP tissue. The typical modification to TRIzol extraction by the use of high salt solution in a previously reported study for tissue with high proteoglycan was insufficient for bovine NP tissue, where undesirable precipitates were formed during the RNA precipitation step. This necessitates other modifications to the protocol. In our study, the combination of additional phase separation and high salt precipitation was shown to be effective to avoid the formation of the undesirable precipitates. The modified TRIzol method was compared with the TRIspin method and shown to give higher RNA yield which resulted in smaller Ct values in RT-qPCR. In addition, we showed that the cryosectioning method was applicable to bovine muscle, mouse IVD and rat NP tissues. This method of RNA preparation also allows simultaneous preparation of tissue for histological study and quantitative gene expression analysis.
- 21 June 2015
- Published by Journal of Biological Methods in Journal of Biological Methods
- Vol. 2 (2) , e20
Open AccessExtraction of RNA from tough tissues with high proteoglycan content by cryosection, second phase separation and high salt precipitation
Reverse-transcription quantitative PCR (RT-qPCR) is a powerful technique for quantification of gene expression. Extraction of RNA directly from human and large animal intervertebral disc (IVD) tissue is technically challenging due to its tough nature, low cell-to-matrix ratio and high proteoglycan content. IVD is consisted of nucleus pulposus (NP) and annulus fibrosis (AF). We compared the yield and quality of RNA extracted from cultured cells using TRIzol and combined TRIzol-column method (TRIspin) with and without bovine NP tissue added for high proteoglycan content simulation. Higher yields were obtained using the TRIzol method compared to the TRIspin method and the quality of RNA extracted using both methods was comparable. Cryosectioning was by far the most effective homogenization method for the tough bovine NP tissue. The typical modification to TRIzol extraction by the use of high salt solution in a previously reported study for tissue with high proteoglycan was insufficient for bovine NP tissue, where undesirable precipitates were formed during the RNA precipitation step. This necessitates other modifications to the protocol. In our study, the combination of additional phase separation and high salt precipitation was shown to be effective to avoid the formation of the undesirable precipitates. The modified TRIzol method was compared with the TRIspin method and shown to give higher RNA yield which resulted in smaller Ct values in RT-qPCR. In addition, we showed that the cryosectioning method was applicable to bovine muscle, mouse IVD and rat NP tissues. This method of RNA preparation also allows simultaneous preparation of tissue for histological study and quantitative gene expression analysis.
- Open Access
- 2 June 2015
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 33 (12) , 1743-1755
Systematic study of cell isolation from bovine nucleus pulposus: Improving cell yield and experiment reliability
Differences in matrix compositions in human nucleus pulposus (NP) clinical samples demand different cell isolation protocols for optimal results but there is no clear guide about this to date. Sub‐optimal protocols may result in low cell yield, limited reliability of results or even failure of experiments. Cell yield, viability and attachment of cells isolated from bovine NP tissue with different protocols were estimated by cell counting, Trypan blue staining and cell culturing respectively. RNA was extracted from isolated cells and quantified by Nanodrop spectrometry and RT‐qPCR. Higher collagenase concentration, longer digestion duration and pronase pre‐treatment increased the cell yield. Cell viability remained high (ACAN, COL2A1, CDH2, KRT18, and KRT19 expression compared to muscle cells for different cell isolation conditions tested. Digestion by collagenase alone without the use of pronase could isolate cells from human degenerated NP tissue but clusters of cells were observed. We suggest the use of the disappearance of tissue as an indirect measure of cells released. This study provides a guide for researchers to decide the parameters involved in NP cell isolation for optimal outcome. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:1743–1755, 2015.
- 2 June 2015
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 33 (12) , 1743-1755
Open AccessSystematic study of cell isolation from bovine nucleus pulposus: Improving cell yield and experiment reliability
Differences in matrix compositions in human nucleus pulposus (NP) clinical samples demand different cell isolation protocols for optimal results but there is no clear guide about this to date. Sub‐optimal protocols may result in low cell yield, limited reliability of results or even failure of experiments. Cell yield, viability and attachment of cells isolated from bovine NP tissue with different protocols were estimated by cell counting, Trypan blue staining and cell culturing respectively. RNA was extracted from isolated cells and quantified by Nanodrop spectrometry and RT‐qPCR. Higher collagenase concentration, longer digestion duration and pronase pre‐treatment increased the cell yield. Cell viability remained high (ACAN, COL2A1, CDH2, KRT18, and KRT19 expression compared to muscle cells for different cell isolation conditions tested. Digestion by collagenase alone without the use of pronase could isolate cells from human degenerated NP tissue but clusters of cells were observed. We suggest the use of the disappearance of tissue as an indirect measure of cells released. This study provides a guide for researchers to decide the parameters involved in NP cell isolation for optimal outcome. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:1743–1755, 2015.
- 1 November 2014
- Published by Elsevier in Analytical Biochemistry
- Vol. 465, 179-186
Correction for concentration overestimation of nucleic acids with phenol
- 1 November 2014
- Published by Elsevier in Analytical Biochemistry
- Vol. 465, 179-186
Correction for concentration overestimation of nucleic acids with phenol
- 1 November 2014
- Published by SAGE Publications in Stem Cells and Development
- Vol. 23 (21) , 2553-2567
A Systematic Review of the Safety and Efficacy of Mesenchymal Stem Cells for Disc Degeneration: Insights and Future Directions for Regenerative Therapeutics
Intervertebral disc degeneration is associated with low-back pain. Mesenchymal stem cells (MSCs) have been used to "regenerate" the disc. The aim of this study was to perform a systematic review of comparative controlled studies that have assessed the safety and efficacy of using MSCs for disc regeneration. Literature databases were extensively searched. Trial design, subject-type, MSC sources, injection method, disc assessment, outcome intervals, and complication events were assessed. Validity of each study was performed. Twenty-four animal studies were included with 20.8% of the studies reporting randomization of groups. Trials in humans fulfilling inclusion criteria were not noted. The studies represented 862 discs that were injected with MSCs and 1,603 discs as controls. All three types of MSCs (ie, bone marrow, synovial, and adipose tissues) showed successful inhibition of disc degeneration. Bone-marrow-derived MSCs demonstrated superior quality of repair compared with other non-MSC treatments. A 2.7% overall complication rate was noted, whereby complications were noted only in rabbits. Overall, evidence suggested that MSCs increased disc space height in the majority of animal models. This is the first systematic review to assess the safety and efficacy of MSCs for the treatment of disc degeneration. Short-term MSC transplantation is safe and effective; however, additional, larger, and higher-quality studies are needed to assess the long-term safety and efficacy. Inconsistencies in methodological design and outcome parameters prevent any robust conclusions. Human-based clinical trials are needed. Recommendations are further made to improve efficacy, reduce potential complications, and standardize techniques for future studies.
- 1 November 2014
- Published by SAGE Publications in Stem Cells and Development
- Vol. 23 (21) , 2553-2567
A Systematic Review of the Safety and Efficacy of Mesenchymal Stem Cells for Disc Degeneration: Insights and Future Directions for Regenerative Therapeutics
Intervertebral disc degeneration is associated with low-back pain. Mesenchymal stem cells (MSCs) have been used to "regenerate" the disc. The aim of this study was to perform a systematic review of comparative controlled studies that have assessed the safety and efficacy of using MSCs for disc regeneration. Literature databases were extensively searched. Trial design, subject-type, MSC sources, injection method, disc assessment, outcome intervals, and complication events were assessed. Validity of each study was performed. Twenty-four animal studies were included with 20.8% of the studies reporting randomization of groups. Trials in humans fulfilling inclusion criteria were not noted. The studies represented 862 discs that were injected with MSCs and 1,603 discs as controls. All three types of MSCs (ie, bone marrow, synovial, and adipose tissues) showed successful inhibition of disc degeneration. Bone-marrow-derived MSCs demonstrated superior quality of repair compared with other non-MSC treatments. A 2.7% overall complication rate was noted, whereby complications were noted only in rabbits. Overall, evidence suggested that MSCs increased disc space height in the majority of animal models. This is the first systematic review to assess the safety and efficacy of MSCs for the treatment of disc degeneration. Short-term MSC transplantation is safe and effective; however, additional, larger, and higher-quality studies are needed to assess the long-term safety and efficacy. Inconsistencies in methodological design and outcome parameters prevent any robust conclusions. Human-based clinical trials are needed. Recommendations are further made to improve efficacy, reduce potential complications, and standardize techniques for future studies.
- Open Access
- 8 November 2011
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 2 (4) , 308-337
Is Macroporosity Absolutely Required for Preliminary in Vitro Bone Biomaterial Study? A Comparison Between Porous Materials and Flat Materials
Porous materials are highly preferred for bone tissue engineering due to space for blood vessel ingrowth, but this may introduce extra experimental variations because of the difficulty in precise control of porosity. In order to decide whether it is absolutely necessary to use porous materials in in vitro comparative osteogenesis study of materials with different chemistries, we carried out osteoinductivity study using C3H/10T1/2 cells, pluripotent mesenchymal stem cells (MSCs), on seven material types: hydroxyapatite (HA), α-tricalcium phosphate (α-TCP) and b-tricalcium phosphate (β-TCP) in both porous and dense forms and tissue culture plastic. For all materials under test, dense materials give higher alkaline phosphatase gene (Alp) expression compared with porous materials. In addition, the cell density effects on the 10T1/2 cells were assessed through alkaline phosphatase protein (ALP) enzymatic assay. The ALP expression was higher for higher initial cell plating density and this explains the greater osteoinductivity of dense materials compared with porous materials for in vitro study as porous materials would have higher surface area. On the other hand, the same trend of Alp mRNA level (HA > β-TCP > α-TCP) was observed for both porous and dense materials, validating the use of dense flat materials for comparative study of materials with different chemistries for more reliable comparison when well-defined porous materials are not available. The avoidance of porosity variation would probably facilitate more reproducible results. This study does not suggest porosity is not required for experiments related to bone regeneration application, but emphasizes that there is often a tradeoff between higher clinical relevance, and less variation in a less complex set up, which facilitates a statistically significant conclusion. Technically, we also show that the base of normalization for ALP activity may influence the conclusion and there may be ALP activity from serum, necessitating the inclusion of “no cell” control in ALP activity assay with materials. These explain the opposite conclusions drawn by different groups on the effect of porosity.
- 8 November 2011
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 2 (4) , 308-337
Open AccessIs Macroporosity Absolutely Required for Preliminary in Vitro Bone Biomaterial Study? A Comparison Between Porous Materials and Flat Materials
Porous materials are highly preferred for bone tissue engineering due to space for blood vessel ingrowth, but this may introduce extra experimental variations because of the difficulty in precise control of porosity. In order to decide whether it is absolutely necessary to use porous materials in in vitro comparative osteogenesis study of materials with different chemistries, we carried out osteoinductivity study using C3H/10T1/2 cells, pluripotent mesenchymal stem cells (MSCs), on seven material types: hydroxyapatite (HA), α-tricalcium phosphate (α-TCP) and b-tricalcium phosphate (β-TCP) in both porous and dense forms and tissue culture plastic. For all materials under test, dense materials give higher alkaline phosphatase gene (Alp) expression compared with porous materials. In addition, the cell density effects on the 10T1/2 cells were assessed through alkaline phosphatase protein (ALP) enzymatic assay. The ALP expression was higher for higher initial cell plating density and this explains the greater osteoinductivity of dense materials compared with porous materials for in vitro study as porous materials would have higher surface area. On the other hand, the same trend of Alp mRNA level (HA > β-TCP > α-TCP) was observed for both porous and dense materials, validating the use of dense flat materials for comparative study of materials with different chemistries for more reliable comparison when well-defined porous materials are not available. The avoidance of porosity variation would probably facilitate more reproducible results. This study does not suggest porosity is not required for experiments related to bone regeneration application, but emphasizes that there is often a tradeoff between higher clinical relevance, and less variation in a less complex set up, which facilitates a statistically significant conclusion. Technically, we also show that the base of normalization for ALP activity may influence the conclusion and there may be ALP activity from serum, necessitating the inclusion of “no cell” control in ALP activity assay with materials. These explain the opposite conclusions drawn by different groups on the effect of porosity.
SEM sample preparation for cells on 3D scaffolds by freeze‐drying and HMDS
Common dehydration methods of cells on biomaterials for scanning electron microscopy (SEM) include air drying, hexamethyldisilazane (HMDS) or tetramethysilane (TMS) treatment and critical point drying (CPD). On the other side, freeze‐drying has been widely employed in dehydrating biological samples and also in preparing porous biomaterial scaffolds but not in preparing cells on three‐dimensional (3D) biomaterials for SEM examination. In this study, we compare cells on porous hydroxyapatite (HA) prepared by air drying, HMDS and freeze‐drying. The effects of fixation and using phosphate buffered saline (PBS) in the fixation were also assessed on three porous calcium phosphate (CaP) materials, namely, HA, α‐tricalcium phosphate (α‐TCP) and β‐tricalcium phosphate (β‐TCP) samples. There is no significant difference in samples prepared by HMDS treatment and freeze‐drying viewed at low magnification. Besides, it is better not to use phosphate buffer in the fixation step for CaP materials to avoid undesirable spontaneous precipitation of CaPs. On the other hand, fewer exchanges of liquids are required for freeze‐drying and hence chemical fixation may not be absolutely required for samples prepared by freeze‐drying. Other technical details of the preparation were also investigated and discussed. This study suggests both HMDS and freeze‐drying can be employed to dehydrate cells on 3D scaffolds for SEM examination. SCANNING 34: 12–25, 2012.
SEM sample preparation for cells on 3D scaffolds by freeze‐drying and HMDS
Common dehydration methods of cells on biomaterials for scanning electron microscopy (SEM) include air drying, hexamethyldisilazane (HMDS) or tetramethysilane (TMS) treatment and critical point drying (CPD). On the other side, freeze‐drying has been widely employed in dehydrating biological samples and also in preparing porous biomaterial scaffolds but not in preparing cells on three‐dimensional (3D) biomaterials for SEM examination. In this study, we compare cells on porous hydroxyapatite (HA) prepared by air drying, HMDS and freeze‐drying. The effects of fixation and using phosphate buffered saline (PBS) in the fixation were also assessed on three porous calcium phosphate (CaP) materials, namely, HA, α‐tricalcium phosphate (α‐TCP) and β‐tricalcium phosphate (β‐TCP) samples. There is no significant difference in samples prepared by HMDS treatment and freeze‐drying viewed at low magnification. Besides, it is better not to use phosphate buffer in the fixation step for CaP materials to avoid undesirable spontaneous precipitation of CaPs. On the other hand, fewer exchanges of liquids are required for freeze‐drying and hence chemical fixation may not be absolutely required for samples prepared by freeze‐drying. Other technical details of the preparation were also investigated and discussed. This study suggests both HMDS and freeze‐drying can be employed to dehydrate cells on 3D scaffolds for SEM examination. SCANNING 34: 12–25, 2012.
- 1 June 2011
- Published by Elsevier in Acta Biomaterialia
- Vol. 7 (6) , 2615-2622
Cell culture medium as an alternative to conventional simulated body fluid
- 1 June 2011
- Published by Elsevier in Acta Biomaterialia
- Vol. 7 (6) , 2615-2622
Cell culture medium as an alternative to conventional simulated body fluid
- 10 November 2010
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 82 (23) , 9601-9605
New Immunoassay Platform Utilizing Yeast Surface Display and Direct Cell Counting
In this study, we report a new immunoassay platform using yeast cell surface display. This method holds promise for very low limit of detection (LOD) and is suitable for 2-Plex antibody recognition. Instead of adopting a conventional enzyme linked immunosorbent assay (ELISA) protocol by detecting the enzymatic activities or other physicochemical properties of the labeled analytes, this approach determines the quantity of an antibody analyte by directly counting the amount of “modified” yeast cells bound with antibody on the cell surface. c-myc and hemagglutinin (HA) tags were employed as an epitope model to demonstrate our approach. This yeast surface display based cell counting immunoassay (abbreviated as YSD-CCI) for anti-c-myc has a detection limit of 0.2 ng/mL, which is about 80 times higher than that of a conventional yeast ELISA under a similar condition. Moreover, the YSD-CCI’s capability for 2-Plex antibody detection was demonstrated by simultaneous detection of anti-c-myc and anti-HA using engineered yeast cells expressing intracellular enhanced green fluorescent protein (EGFP) and mCherry, respectively. This proof-of-concept study paves the way for a new ultrasensitive multiplexed immunoassay method for diagnostic applications.
- 10 November 2010
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 82 (23) , 9601-9605
New Immunoassay Platform Utilizing Yeast Surface Display and Direct Cell Counting
In this study, we report a new immunoassay platform using yeast cell surface display. This method holds promise for very low limit of detection (LOD) and is suitable for 2-Plex antibody recognition. Instead of adopting a conventional enzyme linked immunosorbent assay (ELISA) protocol by detecting the enzymatic activities or other physicochemical properties of the labeled analytes, this approach determines the quantity of an antibody analyte by directly counting the amount of “modified” yeast cells bound with antibody on the cell surface. c-myc and hemagglutinin (HA) tags were employed as an epitope model to demonstrate our approach. This yeast surface display based cell counting immunoassay (abbreviated as YSD-CCI) for anti-c-myc has a detection limit of 0.2 ng/mL, which is about 80 times higher than that of a conventional yeast ELISA under a similar condition. Moreover, the YSD-CCI’s capability for 2-Plex antibody detection was demonstrated by simultaneous detection of anti-c-myc and anti-HA using engineered yeast cells expressing intracellular enhanced green fluorescent protein (EGFP) and mCherry, respectively. This proof-of-concept study paves the way for a new ultrasensitive multiplexed immunoassay method for diagnostic applications.