VAVishal Anand

Vishal Anand

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Vishal Anand has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • High Step-Up Switched-Capacitor ANPC Inverter for Weight-Optimized High-Frequency AC Power Systems in More-Electric Aircraft

    by Vishal Anand, Jagabar Sathik Mohamed Ali, Varsha Singh

    This paper presents a hybrid 13-level active neutral point clamped switched-capacitor multilevel inverter (13L-ANPC-SCMLI) topology with inherent voltage-boosting capability, tailored for high-frequency AC (HFAC) power distribution in more-electric aircraft. The proposed topology offers 100% dc-link voltage utilization, supports midpoint clamping for possible three-phase extension, and achieves up to 33% lower maximum semiconductor voltage stress and 66% lower passive component voltage stress relative to the output voltage. Detailed comparisons with recent 13-level switched-capacitor inverter topologies highlight its advantages in voltage gain, device stress, and suitability for aerospace HFAC systems. Analytical design procedures for the switched-capacitor network and soft-charging inductors are provided. A 500 W prototype is implemented and evaluated for fundamental frequencies from 400 Hz to 1 kHz under dynamic loading, modulation index variation, and input voltage step changes. The prototype demonstrates peak efficiency of 97.08% in both simulation and experiment, along with stable operation across the tested conditions. These results confirm the proposed converter's potential for lightweight, high-efficiency, and high-frequency AC power conversion in aircraft electrification.


  • ANPC Switched-Capacitor 19L Inverter Using SHE PWM for 1-ϕ HFAC PDS Applications

    by Vishal Anand, Jagabar Sathik, Cristian Garcia, Frede Blaabjerg, José Rodríguez

    This article proposes two nineteen-level active neutral point clamped self-balanced switched capacitor multilevel inverter (19L-ANPC-SCMLI) topologies for high-frequency AC power distribution systems (HFAC PDS). Since the proposed topologies have boosting ability, each topology employs four switched capacitor (SC) cells to boost the input voltage. In addition to this, two DC-link capacitors, bidirectional switches, and diodes are used. The Selective Harmonic Elimination (SHE) modulation technique controls the functioning of the inverter. Further, it has a low device count, reduced voltage stress on power components, and self-balanced SCs do not require additional control algorithms and sensors to balance the capacitor voltages. Additionally, the higher number of voltage levels leads to lower harmonic distortion. A fair comparison of voltage gain, voltage stress, device count, and the number of capacitors against the number of levels is compared for the proposed topology and state-of-the-art 19L topologies. Later, the experiment results demonstrate the excellent performance of the proposed 19L-ANPC-SCMLI. Also, high efficiency is achieved, the maximum value is up to 94.42% at 500W for the laboratory setup.


  • A five‐level single‐phase transformerless inverter with lesser component count for PV applications

    by Sukhdev Singh Neti, Varsha Singh, Vishal Anand

    Summary: A transformerless inverter with reactive power capability has gained popularity in grid‐tied photovoltaic applications. This brief report introduces a five‐level transformerless inverter structure based on a switched capacitor (SC), which requires seven switches as semiconductor elements, one capacitor, a small inductor element to limit the high inrush current, and an input DC source in the power circuit. Notably, fewer power components result in lower losses in the inverter system. In order to fulfill the reactive power capability and self‐balanced SCs, a level‐shifted pulse width modulation (LSPWM) scheme is adopted. A simple closed‐loop controller is used for the voltage‐balancing approach to maintain the voltage and grid‐connected operation of the presented five‐level inverter. SC functional operation, modulation method, and voltage self‐balancing are thoroughly explored. In‐depth comparisons are made between the proposed and five‐level state‐of‐the‐art MLIs for PV systems. Finally, the performance of the inverter is verified experimentally in the laboratory environment for a single‐phase 1 kW system. The voltage and current stress are analyzed. The experiment is carried out for the change in modulation index, input, and loading condition. The experimental results suggest the inverter's adequate performance with an efficiency of the inverter is 97.3%.


  • Design of non‐isolated DC‐DC converter using renewable energy source for two‐stage centralized grid connected inverters

    by Mudadla Dhananjaya, Vishal Anand, Varsha Singh, Swapnajit Pattnaik, Devendra Potnuru

    Summary: Recent research has focused on high‐power two‐stage photovoltaic (PV) systems, particularly with the introduction of wideband gap silicon carbide (SiC) devices. A massive inductor or interleaved boost converter is utilized in a standard two‐stage system, requiring a significantly larger number of components and subsequently impacting power density. As a result, the purpose of this research is to provide a topology for a high‐power non‐isolated switched capacitor network‐integrated boost converter (SCNIBC). This architecture employs two of every switch/diode/inductor and capacitor. The suggested architecture has a triple voltage boost at 50% duty ratio, excellent efficiency, and very low inrush current. A suitable analysis is performed to determine the voltage gain, component selection, and power loss analysis. Reliability analysis is studied as per the IEC 61709‐2017 standards. A fair comparison with existing state‐of‐the‐art high‐power PV system topologies is offered. Eventually, the steady‐state experimental findings for a 2.5 kW load are confirmed. The results are also validated for a step adjustment in input voltage from 80 V to 96 V. Lastly, the grid connected operation of converter is studied with a H‐bridge inverter under unity, lagging and leading power factors.


  • Common Ground Buck Type Five-Level Transformerless Inverter With Less Stress

    by Sukhdev Singh Neti, Varsha Singh, Vishal Anand

    The presented brief introduces a new switched capacitor-based transformer-less inverter (SC TLI). This SC TLI configuration is based on a reduced switch count employing only six switches, one of which is a bidirectional switch. It uses only one power source and two SCs to obtain a five-level output voltage. A level shift pulse width modulation (LS-PWM) based simple logic circuit controls SC TLI. It also handles capacitor charging and discharging during operation for each fundamental cycle. The SCs are self-balanced and do not require any specific controller. Further, detailed comparative studies are performed with existing arts of literature to determine the merits of the SC TLI. A prototype SC TLI model is made in the laboratory. The experimental results from the laboratory prototype validate the feasibility of the SC TLI. The voltage, current stress, and junction temperature across the power component are analyzed for the SC TLI design. Finally, this SC TLI performance characteristic is presented for different loading conditions.


  • Seventeen Level Switched Capacitor Inverters With the Capability of High Voltage Gain and Low Inrush Current

    by Vishal Anand, Varsha Singh, Xiaoqiang Guo, Mohammad Ali Jagabar Sathik, Yam Prasad Siwakoti, Saad Mekhilef, Frede Blaabjerg

    The topology of a 17-level (17 L) hybrid switched-capacitor multilevel inverter (SCMLI) with high voltage gain is presented in this work. A single source, four capacitors, six half-bridge switches (five with anti-parallel diodes and one half-bridge without anti-parallel diodes), and five diodes is used in the proposed SCMLI. The total standing voltage (TSV), cost function (CF), and maximum blocking voltage (MBV) across the switches and capacitors are all reduced by this inverter. The MBV is half the output voltage, lowering component costs and reducing the overall size of the inverter to achieve high power density. In addition, a soft-charging approach has been implemented to reduce the current stress on the components. The proposed SCMLI advantages over current state-of-the-art 17 L inverters are fully examined in terms of TSV, CF, and MBV. To determine the viability of the proposed 17 L inverter, several experimental tests on a 1 kW laboratory prototype are conducted.


  • Open Access

    A Generalized Switched-Capacitor Multilevel Inverter Topology with Voltage Boosting Ability and Reduced Inrush Current

    by Vishal Anand, Varsha Singh, M. Jagabar Sathik, Dhafer Almakhles

    This article presents a novel quadruple boost inverter (QBI) with an integrated boost stage that comprises an inductor, a capacitor, a switch, and an input source. The inductor on the input side limits the inrush current and also the capacitor charging current ripples. The QBI topology comprises a dc source, an input inductor, nine switches, three diodes, and capacitors. This produces a nine-level waveform, which reduces the need for additional filters such as inductors and capacitors. The proposed QBI is elementary, compact, and needs fewer components than existing nine levels inverter. Compared to the typical triangular carrier-based sinusoidal pulse width modulation, the newly developed parabolic level-shifted carrier has a much greater RMS value. Another advantage of the proposed topology is extension for generating higher voltage levels without increment in the blocking voltage across the switches. This makes the topology ideal for medium voltage high power applications. The output voltage has been determined in terms of selection, sizing, and expression. The proposed QBI is compared to existing similar nine-level inverters in order to assess its efficacy. The experiment is performed on a laboratory prototype to state the practical feasibility of QBI topology for the inductive load, variation in input, load, and modulation index.


  • Dual Boost Five-Level Switched-Capacitor Inverter With Common Ground

    by Vishal Anand, Varsha Singh, Jagabar Sathik Mohamed Ali

    This brief presents a five-level common ground type (5L-CGT) inverter topology with double voltage boosting. This topology uses only eight switches, two capacitors that can be charged equal to the input source. The advantageous feature of this topology is the CGT configuration between the input source and output load, which ensures minimal common-mode voltage and leakage current. A detailed analysis is done to select and size capacitors, along with quasi-soft charging to minimize the charging current ripples across the capacitors. The performance of the proposed 5L-CGT inverter is tested for inductive load, varying the modulation index/load/input voltage under experimental test conditions. A detailed comparison is done with the existing state-of-art that shows the merits of the proposed topology in terms of equal voltage stress across the capacitor with voltage boost. The power loss analysis for the inverter is carried out using PLECS with efficiency to be 97.20%, and the experimental efficiency is found to be 96.54% for the 900W inverter prototype.