Daniel K. McCluskey
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Daniel K. McCluskey has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Ian D. Johnston
Department of Engineering and Technology, School of Physics, Engineering & Computer Science, University of Hertfordshire, Hatfield AL10 9EU, UK
4 shared publications - Mark C Tracey
University of Hertfordshire
4 shared publications - Benjamin John Murray
Institute for Climate and Atmospheric Science, School of Earth and Environment, University of Leeds, Leeds LS2 9JT, UK
2 shared publications - Loïc Coudron
School of Engineering and Computer Science, University of Hertfordshire;
2 shared publications M. B. McDonnell
School of Engineering and Technology
2 shared publicationsA. E. Holdo̸
University of Hertfordshire, Hatfield, UK
1 shared publication
Latest Publications
- Open Access
- 1 January 2025
- Published by AIP Publishing in Biomicrofluidics
- Vol. 19 (1) , 011502
Microfluidics for the biological analysis of atmospheric ice-nucleating particles: Perspectives and challenges
Atmospheric ice-nucleating particles (INPs) make up a vanishingly small proportion of atmospheric aerosol but are key to triggering the freezing of supercooled liquid water droplets, altering the lifetime and radiative properties of clouds and having a substantial impact on weather and climate. However, INPs are notoriously difficult to model due to a lack of information on their global sources, sinks, concentrations, and activity, necessitating the development of new instrumentation for quantifying and characterizing INPs in a rapid and automated manner. Microfluidic technology has been increasingly adopted by ice nucleation research groups in recent years as a means of performing droplet freezing analysis of INPs, enabling the measurement of hundreds or thousands of droplets per experiment at temperatures down to the homogeneous freezing of water. The potential for microfluidics extends far beyond this, with an entire toolbox of bioanalytical separation and detection techniques developed over 30 years for medical applications. Such methods could easily be adapted to biological and biogenic INP analysis to revolutionize the field, for example, in the identification and quantification of ice-nucleating bacteria and fungi. Combined with miniaturized sampling techniques, we can envisage the development and deployment of microfluidic sample-to-answer platforms for automated, user-friendly sampling and analysis of biological INPs in the field that would enable a greater understanding of their global and seasonal activity. Here, we review the various components that such a platform would incorporate to highlight the feasibility, and the challenges, of such an endeavor, from sampling and droplet freezing assays to separations and bioanalysis.
- 1 January 2025
- Published by AIP Publishing in Biomicrofluidics
- Vol. 19 (1) , 011502
Open AccessMicrofluidics for the biological analysis of atmospheric ice-nucleating particles: Perspectives and challenges
Atmospheric ice-nucleating particles (INPs) make up a vanishingly small proportion of atmospheric aerosol but are key to triggering the freezing of supercooled liquid water droplets, altering the lifetime and radiative properties of clouds and having a substantial impact on weather and climate. However, INPs are notoriously difficult to model due to a lack of information on their global sources, sinks, concentrations, and activity, necessitating the development of new instrumentation for quantifying and characterizing INPs in a rapid and automated manner. Microfluidic technology has been increasingly adopted by ice nucleation research groups in recent years as a means of performing droplet freezing analysis of INPs, enabling the measurement of hundreds or thousands of droplets per experiment at temperatures down to the homogeneous freezing of water. The potential for microfluidics extends far beyond this, with an entire toolbox of bioanalytical separation and detection techniques developed over 30 years for medical applications. Such methods could easily be adapted to biological and biogenic INP analysis to revolutionize the field, for example, in the identification and quantification of ice-nucleating bacteria and fungi. Combined with miniaturized sampling techniques, we can envisage the development and deployment of microfluidic sample-to-answer platforms for automated, user-friendly sampling and analysis of biological INPs in the field that would enable a greater understanding of their global and seasonal activity. Here, we review the various components that such a platform would incorporate to highlight the feasibility, and the challenges, of such an endeavor, from sampling and droplet freezing assays to separations and bioanalysis.
- Open Access
- 5 July 2023
- Published by Copernicus GmbH in Aerosol Research
- Vol. 1 (1) , 13-16
Editorial: Aerosol Research – a new diamond open-access journal covering the breadth of aerosol science and technology
- 5 July 2023
- Published by Copernicus GmbH in Aerosol Research
- Vol. 1 (1) , 13-16
Open AccessEditorial: Aerosol Research – a new diamond open-access journal covering the breadth of aerosol science and technology
- Open Access
- 25 October 2017
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 7 (78) , 49633-49648
Protein droplet actuation on superhydrophobic surfaces: a new approach toward anti-biofouling electrowetting systems
Among Lab-on-a-chip techniques, digital microfluidics (DMF), allowing the precise actuation of discrete droplets, is a highly promising, flexible, biochemical assay platform for biomedical and bio-detection applications. However the durability of DMF systems remains a challenge due to biofouling of the droplet-actuating surface when high concentrations of biomolecules are employed. To address this issue, the use of superhydrophobic materials as the actuating surface in DMF devices is examined. The change in contact angle by electrowetting of deionised water and ovalbumin protein samples is characterised on different surfaces (hydrophobic and superhydrophobic). Ovalbumin droplets at 1 mg ml−1 concentration display better electrowetting reversibility on Neverwet®, a commercial superhydrophobic material, than on Cytop®, a typical DMF hydrophobic material. Biofouling rate, characterised by roll-off angle measurement of ovalbumin loaded droplets and further confirmed by measurements of the mean fluorescence intensity of labelled fibrinogen, appears greatly reduced on Neverwet®. Transportation of protein laden droplets (fibrinogen at concentration 0.1 mg ml−1 and ovalbumin at concentration 1 mg ml−1 and 10 mg ml−1) is successfully demonstrated using electrowetting actuation on both single-plate and parallel-plate configurations with performance comparable to that of DI water actuation. In addition, although droplet splitting requires further attention, merging and efficient mixing are demonstrated.
- 25 October 2017
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 7 (78) , 49633-49648
Open AccessProtein droplet actuation on superhydrophobic surfaces: a new approach toward anti-biofouling electrowetting systems
Among Lab-on-a-chip techniques, digital microfluidics (DMF), allowing the precise actuation of discrete droplets, is a highly promising, flexible, biochemical assay platform for biomedical and bio-detection applications. However the durability of DMF systems remains a challenge due to biofouling of the droplet-actuating surface when high concentrations of biomolecules are employed. To address this issue, the use of superhydrophobic materials as the actuating surface in DMF devices is examined. The change in contact angle by electrowetting of deionised water and ovalbumin protein samples is characterised on different surfaces (hydrophobic and superhydrophobic). Ovalbumin droplets at 1 mg ml−1 concentration display better electrowetting reversibility on Neverwet®, a commercial superhydrophobic material, than on Cytop®, a typical DMF hydrophobic material. Biofouling rate, characterised by roll-off angle measurement of ovalbumin loaded droplets and further confirmed by measurements of the mean fluorescence intensity of labelled fibrinogen, appears greatly reduced on Neverwet®. Transportation of protein laden droplets (fibrinogen at concentration 0.1 mg ml−1 and ovalbumin at concentration 1 mg ml−1 and 10 mg ml−1) is successfully demonstrated using electrowetting actuation on both single-plate and parallel-plate configurations with performance comparable to that of DI water actuation. In addition, although droplet splitting requires further attention, merging and efficient mixing are demonstrated.
- Open Access
- 1 May 2016
- Published by Elsevier in Journal of Aerosol Science
- Vol. 95, 43-53
A prototype personal aerosol sampler based on electrostatic precipitation and electrowetting-on-dielectric actuation of droplets
- 1 May 2016
- Published by Elsevier in Journal of Aerosol Science
- Vol. 95, 43-53
Open AccessA prototype personal aerosol sampler based on electrostatic precipitation and electrowetting-on-dielectric actuation of droplets
- Open Access
- 22 June 2015
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 90 (10) , 1927-1936
Electromagnetic stirring in a microbioreactor with non‐conventional chamber morphology and implementation of multiplexed mixing
BACKGROUND: Microbioreactors have emerged as novel tools for early bioprocess development. Mixing lies at the heart of bioreactor operation (at all scales). The successful implementation of micro‐stirring methods is thus central to the further advancement of microbioreactor technology. The aim of this study was to develop a micro‐stirring method that aids robust microbioreactor operation and facilitates cost‐effective parallelization.RESULTS: A microbioreactor was developed with a novel micro‐stirring method involving the movement of a magnetic bead by sequenced activation of a ring of electromagnets. The micro‐stirring method offers flexibility in chamber designs, and mixing is demonstrated in cylindrical, diamond and triangular shaped reactor chambers. Mixing was analyzed for different electromagnet on/off sequences; mixing times of 4.5 s, 2.9 s, and 2.5 s were achieved for cylindrical, diamond and triangular shaped chambers, respectively. Ease of micro‐bubble free priming, a typical challenge of cylindrical shaped microbioreactor chambers, was obtained with a diamond‐shaped chamber. Consistent mixing behavior was observed between the constituent reactors in a duplex system.CONCLUSION: A novel stirring method using electromagnetic actuation offering rapid mixing and easy integration with microbioreactors was characterized. The design flexibility gained enables fabrication of chambers suitable for microfluidic operation, and a duplex demonstrator highlights potential for cost‐effective parallelization. Combined with a previously published cassette‐like fabrication of microbioreactors, these advances will facilitate the development of robust and parallelized microbioreactors. © 2015 The Authors. Journal of Chemical Technology & Biotechnology published by John Wiley & Sons Ltd on behalf of Society of Chemical Industry.
- 22 June 2015
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 90 (10) , 1927-1936
Open AccessElectromagnetic stirring in a microbioreactor with non‐conventional chamber morphology and implementation of multiplexed mixing
BACKGROUND: Microbioreactors have emerged as novel tools for early bioprocess development. Mixing lies at the heart of bioreactor operation (at all scales). The successful implementation of micro‐stirring methods is thus central to the further advancement of microbioreactor technology. The aim of this study was to develop a micro‐stirring method that aids robust microbioreactor operation and facilitates cost‐effective parallelization.RESULTS: A microbioreactor was developed with a novel micro‐stirring method involving the movement of a magnetic bead by sequenced activation of a ring of electromagnets. The micro‐stirring method offers flexibility in chamber designs, and mixing is demonstrated in cylindrical, diamond and triangular shaped reactor chambers. Mixing was analyzed for different electromagnet on/off sequences; mixing times of 4.5 s, 2.9 s, and 2.5 s were achieved for cylindrical, diamond and triangular shaped chambers, respectively. Ease of micro‐bubble free priming, a typical challenge of cylindrical shaped microbioreactor chambers, was obtained with a diamond‐shaped chamber. Consistent mixing behavior was observed between the constituent reactors in a duplex system.CONCLUSION: A novel stirring method using electromagnetic actuation offering rapid mixing and easy integration with microbioreactors was characterized. The design flexibility gained enables fabrication of chambers suitable for microfluidic operation, and a duplex demonstrator highlights potential for cost‐effective parallelization. Combined with a previously published cassette‐like fabrication of microbioreactors, these advances will facilitate the development of robust and parallelized microbioreactors. © 2015 The Authors. Journal of Chemical Technology & Biotechnology published by John Wiley & Sons Ltd on behalf of Society of Chemical Industry.
- Top Cited PapersOpen Access
- 28 February 2014
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 24 (3)
Mechanical characterization of bulk Sylgard 184 for microfluidics and microengineering
- 28 February 2014
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 24 (3)
Top Cited PapersOpen AccessMechanical characterization of bulk Sylgard 184 for microfluidics and microengineering
- Open Access
- 23 January 2014
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 17 (3) , 509-518
Dean flow focusing and separation of small microspheres within a narrow size range
- 23 January 2014
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 17 (3) , 509-518
Open AccessDean flow focusing and separation of small microspheres within a narrow size range
- 1 January 2005
- Published by ASME International
- p. 317-325
An Overview of Ballast Water Treatment Methods
One of the greatest threats to the world’s oceans is the transfer and potential introduction of harmful organisms in environments to which they are not indigenous. Ballast water deposited by marine vessels has been identified as a key factor responsible for this transfer and introduction. The significance of transferral of species has led to diverse research and development into ballast water treatment methods. However, despite the number of ballast water management techniques in development, at present the exchange of ballast water in open oceans is the only management technique widely used. This paper provides an overview of Ballast Water Treatment techniques currently at a research or development stage. An assessment of the potential effectiveness of each method, its corrosion implications and economic cost are all presented together with preliminary recommendations and an outline of future work.
- 1 January 2005
- Published by ASME International
- p. 317-325
An Overview of Ballast Water Treatment Methods
One of the greatest threats to the world’s oceans is the transfer and potential introduction of harmful organisms in environments to which they are not indigenous. Ballast water deposited by marine vessels has been identified as a key factor responsible for this transfer and introduction. The significance of transferral of species has led to diverse research and development into ballast water treatment methods. However, despite the number of ballast water management techniques in development, at present the exchange of ballast water in open oceans is the only management technique widely used. This paper provides an overview of Ballast Water Treatment techniques currently at a research or development stage. An assessment of the potential effectiveness of each method, its corrosion implications and economic cost are all presented together with preliminary recommendations and an outline of future work.