DWDavid Liang Tai Wong

David Liang Tai Wong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


David Liang Tai Wong has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Low Complexity Binarized 2D-CNN Classifier for Wearable Edge AI Devices

    by David Liang Tai Wong, Yongfu Li, Deepu John, Weng Khuen Ho, Chun-Huat Heng

    Wearable Artificial Intelligence-of-Things (AIoT) devices exhibit the need to be resource and energy-efficient. In this paper, we introduced a quantized multilayer perceptron (qMLP) for converting ECG signals to binary image, which can be combined with binary convolutional neural network (bCNN) for classification. We deploy our model into a low-power and low-resource field programmable gate array (FPGA) fabric. The model requires 5.8× lesser multiply and accumulate (MAC) operations than known wearable CNN models. Our model also achieves a classification accuracy of 98.5%, sensitivity of 85.4%, specificity of 99.5%, precision of 93.3%, and F1- score of 89.2%, along with dynamic power dissipation of 34.9 μW.


  • An Energy Efficient ECG Ventricular Ectopic Beat Classifier Using Binarized CNN for Edge AI Devices

    by David Liang Tai Wong, Yongfu Li, Deepu John, Weng Khuen Ho, Chun-Huat Heng

    Wearable Artificial Intelligence-of-Things (AIoT) requires edge devices to be resource and energy-efficient. In this paper, we design and implement an efficient binary convolutional neural network (bCNN) algorithm utilizing function-merging and block-reuse techniques to classify between Ventricular and non-Ventricular Ectopic Beat images. We deploy our model into a low-resource low-power field programmable gate array (FPGA) fabric. Our model achieves a classification accuracy of 97.3%, sensitivity of 91.3%, specificity of 98.1%, precision of 86.7%, and F1-score of 88.9%, along with dynamic power dissipation of only 10.5-W.


  • An Integrated Wearable Wireless Vital Signs Biosensor for Continuous Inpatient Monitoring

    by David Liang Tai Wong, Jufeng Yu, Yongfu Li, Chacko John Deepu, Duy Hoa Ngo, Chongyu Zhou, Shashi Raj Singh, A. S. L. Koh, R. T. Y. Hong, Bharadwaj Veeravalli, et al.

    A compact, light-weight and low-power wireless vital signs monitoring system based on Wireless Body Area Network (WBAN) protocol has been developed. The system, VySys, includes two compact wearable wireless biosensor devices for continuous vital signs capturing and transmission, a gateway to relay the message collected from the biosensors to cloud, and finally a client apps to access and display the stored data in the cloud. Both biosensor devices can last for 24 hours and weigh less than 22 g and 44 g, respectively. They consist of proprietary in-house bio-sensing integrated circuit (IC) and commercial off-the-shelf Bluetooth Low Energy (BLE) module. VySys has been deployed in clinical trials with 14 subjects. From the studies, the accuracy and advantage of VySys are evaluated and the five vital signs captured (heart rate (HR), respiration rate (RR), temperature (TMP), oxygen saturation (SpO2) and systolic blood pressure (SBP)) are benchmarked against a commercial medical-grade device. The results show strong statistical correlation (r > 0.68). In terms of clinical significance, all its mean difference are within limits of accepted clinical discrepancies. In terms of efficacy by comparing against the best known reported results, (1) VsSys is more precise by 28.2%, 36.2%, 70.0%, 37.6% and 34.4% for HR, RR, TMP, SpO2 and SBP, respectively and (2) has a narrower 95% limit of agreement (LoA) by 24.5%, 23.9%, 50.6%, 37.4% and 34.4% for HR, RR, TMP, SpO2 and SBP, respectively.