Juan Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Juan Huang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Ben Cyphers
College of Optometry, The Ohio State University, Columbus, OH, USA
1 shared publication- Bingnan Li
School of Life Sciences, Tianjin Polytechnic University, Tianjin, China
1 shared publication - Huiquan Wang
School of Life Sciences, Tiangong University, Tianjin, China
1 shared publication - Jeffrey J. Walline
The Ohio State University College of Optometry Columbus Ohio USA
1 shared publication - Jinhai Wang
School of Life Sciences, TianGong University 1 , Tianjin 300387, China
1 shared publication - Ruijuan Chen
School of Life Sciences, TianGong University 1 , Tianjin 300387, China
1 shared publication
Latest Publications
- Open Access
- 20 February 2022
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 106 (3) , 311-321
Symptoms and ocular findings associated with administration of 0.01% atropine in young adults
This paper provides eye care practitioners with important information about the potential side effects of 0.01% atropine.Eye care practitioners routinely administer 0.01% atropine eye drops nightly...
- 20 February 2022
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 106 (3) , 311-321
Open AccessSymptoms and ocular findings associated with administration of 0.01% atropine in young adults
This paper provides eye care practitioners with important information about the potential side effects of 0.01% atropine.Eye care practitioners routinely administer 0.01% atropine eye drops nightly...
- Open Access
- 19 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 185597-185606
A Novel Algorithm for High-Resolution Magnetic Induction Tomography Based on Stacked Auto-Encoder for Biological Tissue Imaging
Magnetic induction tomography (MIT) is a non-invasive and non-contact imaging method that uses an excitation coil to generate time-varying magnetic fields in space and reconstruct the internal conductivity distribution based on the phase difference. In this study, a new MIT reconstruction algorithm was proposed for non-contact measurement and monitoring of the location of the anomaly in the biomedical object of interest. To reconstruct the distribution of electrical characteristics inside the biological tissue, this technique uses a stacked auto-encoder (SAE) neural network composed of a multi-layer automatic encoder. The location and reconstruction accuracy of the anomaly based on SAE and back-projection were compared, and a hemorrhagic stroke was simulated to verify the practicability of the proposed algorithm. The results showed that the relative error of reconstruction based on the SAE network algorithm reached 0.29%, which improved anomaly reconstruction accuracy and reduced the prediction time to 0.02 s. At the same time, the network was used for the reconstruction of hemorrhagic stroke in different locations, amounts, and shapes. Accordingly, the SAE neural network reconstruction algorithm proposed in this study, which can autonomously learn the non-linear relationship between input and output, can solve the defects of the traditional reconstruction algorithm, such as serious artifacts and complex calculations.
- 19 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 185597-185606
Open AccessA Novel Algorithm for High-Resolution Magnetic Induction Tomography Based on Stacked Auto-Encoder for Biological Tissue Imaging
Magnetic induction tomography (MIT) is a non-invasive and non-contact imaging method that uses an excitation coil to generate time-varying magnetic fields in space and reconstruct the internal conductivity distribution based on the phase difference. In this study, a new MIT reconstruction algorithm was proposed for non-contact measurement and monitoring of the location of the anomaly in the biomedical object of interest. To reconstruct the distribution of electrical characteristics inside the biological tissue, this technique uses a stacked auto-encoder (SAE) neural network composed of a multi-layer automatic encoder. The location and reconstruction accuracy of the anomaly based on SAE and back-projection were compared, and a hemorrhagic stroke was simulated to verify the practicability of the proposed algorithm. The results showed that the relative error of reconstruction based on the SAE network algorithm reached 0.29%, which improved anomaly reconstruction accuracy and reduced the prediction time to 0.02 s. At the same time, the network was used for the reconstruction of hemorrhagic stroke in different locations, amounts, and shapes. Accordingly, the SAE neural network reconstruction algorithm proposed in this study, which can autonomously learn the non-linear relationship between input and output, can solve the defects of the traditional reconstruction algorithm, such as serious artifacts and complex calculations.